首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Highly polar, non-gas-chromatographable compounds have few unambiguous analysis protocols for environmental applications. A recent environmental investigation, concerning the identification of a non-gas-chromatographable yellow component in chemical waste water and in effluents from a biological wastewater treatment plant required the use of a number of analytical approaches. Electrospray mass spectrometry, tandem mass spectrometry, high-performance liquid chromatography, nuclear magnetic resonance, and molecular spectroscopy of commercial and synthesized chlorodinitrophenol isomers were required in order to identify the specific isomer causing the color. The present report summarizes the electrospray ionization and tandem mass spectrometric studies that were used. The mass spectrometric study shows that two different isomers of chlorodinitrophenol exhibit very different collision-induced dissociation (CID) spectra. Differences in the tandem mass spectra can be attributed to the different structures of the anions formed from these two different isomers. Instrumentation that uses electrospray ionization and produces CID mass spectra and optical absorption spectra in a single analysis may be required in order to produce highly specific information on non-gas-chromatographable compounds found in the environment.  相似文献   

2.
A simple and inexpensive liquid chromatography/mass spectrometry (LC/MS) method was developed for the quantitation of acrylamide in various food products. The method involved spiking the isotope-substituted internal standard (1-C13 acrylamide) onto 6.00 g of the food product, adding 40 mL distilled/deionized water, and heating at 65 degrees C for 30 min. Afterwards, 10 mL ethylene dichloride was added and the mixture was homogenized for 30 s and centrifuged at 2700 x g for 30 min, and then 8 g supernatant was extracted with 10, 5, and 5 mL portions of ethyl acetate. The extracts were combined, dried with sodium sulfate, and concentrated to 100-200 microL. Acrylamide was determined by analysis of the final extract on a single quadrupole, bench-top mass spectrometer with electrospray ionization, using a 2 mm id C18 column and monitoring m/z = 72 (acrylamide) and m/z = 73 (internal standard). For difficult food matrixes, such as coffee and cocoa, a solid-phase extraction cleanup step was incorporated to improve both chromatography and column lifetime. The method had a limit of quantitation of 10 ppb, and coefficients of determination (r2) for calibration curves were typically better than 0.998. Acceptable spike recovery results were achieved in 11 different food matrixes. Precision in potato chip analyses was 5-8% (relative standard deviation). This method provides an LC/MS alternative to the current LC/MS/MS methods and derivatization gas chromatography/mass spectrometry methods, and is applicable to difficult food products such as coffee, cocoa, and high-salt foods.  相似文献   

3.
A liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based method for the detection of pesticides in tap and treated wastewater was developed and validated according to the ISO/IEC 17025:1999. Key features of this method include direct injection of 100 μL of sample, an 11 min separation by means of a rapid resolution liquid chromatography system with a 4.6 mm × 50 mm, 1.8 μm particle size reverse phase column and detection by electrospray ionization (ESI) MS-MS. The limits of detection were below 15 ng L−1 and correlation coefficients for the calibration curves in the range of 30-2000 ng L−1 were higher than 0.99. Precision was always below 20% and accuracy was confirmed by external evaluation. The main advantages of this method are direct injection of sample without preparative procedures and low limits of detection that fulfill the requirements established by the current European regulations governing pesticide detection.  相似文献   

4.
Glutathione (GSH) is a tripeptide composed of glutamate, cysteine, and glycine. It is present in practically all cells and has several important roles, such as preventing the oxidation of the sulfhydryl groups of proteins within a cell. Evidence for GSH deficiency or depletion has been found in a variety of diseases and toxicity-related studies, including diabetes and induction of oxidative stress to form reactive oxygen species which cause DNA, lipid, and protein oxidations. A simple, selective, and sensitive analytical method for measuring low levels of GSH in biological fluids would therefore be desirable to conduct GSH deficiency or depletion-related mechanistic toxicity studies. Here a method for both low- and high-level quantitation of GSH from cultured cells and rat liver tissues via liquid chromatography/positive electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) has been developed. The lower limit of quantitation (LOQ) of the method was 5 ng/mL. The method is linear over a wide dynamic concentration range of 5.0 to 5000.0 ng/mL, with a correlation coefficient R2 > 0.99. The intra-day assay precision relative standard deviation (RSD) values for all quality control (QC) samples were < or =16.31%, with accuracy values ranging from 94.13 to 97.80%. The inter-day assay precision RSD values for all QC samples were < or =15.94%, with accuracy values ranging from 94.51 to 100.29%. With this method, low levels of GSH from diethyl maleate (DEM)-treated mouse lymphoma cells, and GSH in rat liver tissues, were quantified.  相似文献   

5.
A true direct solid sampling electrothermal atomic absorption spectrometry method with Zeeman-effect background correction (Analytik Jena ZEEnit 60 AAS) was developed for the determination of As, Cd, Hg, Pb, Sb and Zn in powdered titanium dioxide of pharmaceutical, food and cosmetics grade. The interaction of the titanium matrix and graphite surface of the sample carrier boat in a transversely heated graphite tube atomizer was investigated. Conversion of titanium dioxide to interfering TiO2–TiC-liquid phase, running out the sampling boat, was observed at temperatures above 2000 °C. The temperature program was optimized accordingly for these volatile analytes in atomization and cleaning steps in order to prevent this interference and to prolong significantly the analytical lifetime of the boat to more than one thousand runs. For all elements, calibration by aqueous standard addition method, by wet-chemically analyzed samples with different content of analytes and/or by dosing one sample in different amounts, were proved as adequate quantification procedures. Linear dynamic calibration working ranges can be considerably expanded up to two orders of magnitude within one measurement run by applying three-field dynamic mode of the Zeeman background correction system. The results obtained by true direct solid sampling technique are compared with those of other independent, mostly wet-chemical methods. Very low limits of detection (3σ criterion) of true solid sampling technique of 21, 0.27, 24, 3.9, 6.3 and 0.9 ng g− 1 were achieved for As, Cd, Hg, Pb, Sb and Zn, respectively.  相似文献   

6.
The trace impurities Cr, Cu, Fe, K, Mn, Sb and Zn were determined in powdered aluminum nitride by direct solid sampling graphite furnace atomic absorption spectrometry using a ZEEnit 60 atomic absorption spectrometer. This spectrometer features inverse Zeeman-effect background correction and a variable magnetic field enabling measurements in two sensitivity modes over a concentration range of three orders of magnitude. The measurement sensitivity can be adjusted to the analyte concentration in the sample. The use of chemical modifiers was not necessary. Calibration was carried out by means of calibration curves obtained with aqueous standard solutions. Accuracy was checked mainly by comparison of the results with those obtained by instrumental and radiochemical neutron activation analysis whereby, excluding the results for potassium, no significant differences were found by carrying out the t-test at the significance level 0.05. The limits of detection were between 0.05 ng g−1 (Zn) and 80 ng g−1 (Fe) and the relative standard deviations below 11 %. With the proposed method, up to ten measurement cycles can be carried out in one hour.  相似文献   

7.
A specially designed thermal vaporiser was used with a process mass spectrometer designed for gas analysis to monitor the esterification of butan-1-ol and acetic anhydride. The reaction was conducted at two scales: in a 150 mL flask and a 1 L jacketed batch reactor, with liquid delivery flow rates to the vaporiser of 0.1 and 1.0 mL min−1, respectively. Mass spectrometry measurements were made at selected ion masses, and classical least squares multivariate linear regression was used to produce concentration profiles for the reactants, products and catalyst. The extent of reaction was obtained from the butyl acetate profile and found to be 83% and 76% at 40 °C and 20 °C, respectively, at the 1 L scale. Reactions in the 1 L reactor were also monitored by in-line mid-infrared (MIR) spectrometry; off-line gas chromatography (GC) was used as a reference technique when building partial least squares (PLS) multivariate calibration models for prediction of butyl acetate concentrations from the MIR spectra. In validation experiments, good agreement was achieved between the concentration of butyl acetate obtained from in-line MIR spectra and off-line GC. In the initial few minutes of the reaction the profiles for butyl acetate derived from on-line direct liquid sampling mass spectrometry (DLSMS) differed from those of in-line MIR spectrometry owing to the 2 min transfer time between the reactor and mass spectrometer. As the reaction proceeded, however, the difference between the concentration profiles became less noticeable. DLSMS had advantages over in-line MIR spectrometry as it was easier to generate concentration profiles for all the components in the reaction. Also, it was possible to detect the presence of a simulated impurity of ethanol (at levels of 2.6 and 9.1% mol/mol) in butan-1-ol, and the resulting production of ethyl acetate, by DLSMS, but not by in-line MIR spectrometry.  相似文献   

8.
Mass spectrometric methods for the trace analysis of inorganic materials with their ability to provide a very sensitive multielemental analysis have been established for the determination of trace and ultratrace elements in high-purity materials (metals, semiconductors and insulators), in different technical samples (e.g. alloys, pure chemicals, ceramics, thin films, ion-implanted semiconductors), in environmental samples (waters, soils, biological and medical materials) and geological samples. Whereas such techniques as spark source mass spectrometry (SSMS), laser ionization mass spectrometry (LIMS), laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), glow discharge mass spectrometry (GDMS), secondary ion mass spectrometry (SIMS) and inductively coupled plasma mass spectrometry (ICP-MS) have multielemental capability, other methods such as thermal ionization mass spectrometry (TIMS), accelerator mass spectrometry (AMS) and resonance ionization mass spectrometry (RIMS) have been used for sensitive mono- or oligoelemental ultratrace analysis (and precise determination of isotopic ratios) in solid samples. The limits of detection for chemical elements using these mass spectrometric techniques are in the low ng g−1 concentration range. The quantification of the analytical results of mass spectrometric methods is sometimes difficult due to a lack of matrix-fitted multielement standard reference materials (SRMs) for many solid samples. Therefore, owing to the simple quantification procedure of the aqueous solution, inductively coupled plasma mass spectrometry (ICP-MS) is being increasingly used for the characterization of solid samples after sample dissolution. ICP-MS is often combined with special sample introduction equipment (e.g. flow injection, hydride generation, high performance liquid chromatography (HPLC) or electrothermal vaporization) or an off-line matrix separation and enrichment of trace impurities (especially for characterization of high-purity materials and environmental samples) is used in order to improve the detection limits of trace elements. Furthermore, the determination of chemical elements in the trace and ultratrace concentration range is often difficult and can be disturbed through mass interferences of analyte ions by molecular ions at the same nominal mass. By applying double-focusing sector field mass spectrometry at the required mass resolution—by the mass spectrometric separation of molecular ions from the analyte ions—it is often possible to overcome these interference problems. Commercial instrumental equipment, the capability (detection limits, accuracy, precision) and the analytical application fields of mass spectrometric methods for the determination of trace and ultratrace elements and for surface analysis are discussed.  相似文献   

9.
1,12‐Bis[5‐(2‐hydroxyethyl)‐4‐methyl‐1,3‐thiazol‐3‐ium]dodecane dibromide (SAR97276, T3) is a new antimalarial drug, which is currently being evaluated in clinical trials for severe malaria. Drug accumulation inside the parasite and a dual mechanism of action are a major strength of this compound, as it could help delay the development of resistance. The purpose of this article was to develop a rapid resolution LC‐MS method for quantifying SAR97276 in mouse tissues. The LC system consisted of Zorbax Eclipse XDB C8 (1.8 μm, 50×4.6 mm, 60°C) column. Elution with a gradient mobile phase consisting of ACN–trimethylamine‐formate buffer (pH 3) at a flow rate of 1 mL/min yielded sharp, utmost‐resolved peaks within 2 min. Tissue samples were powdered under liquid nitrogen. After protein precipitation with citric acid, SPE using WCX cartridges was used for sample preparation. There was no influence of the matrix on the detection of either SAR97276 or the IS. Assay precision was <13% and accuracy was 90–107%. The lower LOQs were 3.3 μg/kg in brain and 33 μg/kg in liver and heart. This newly developed method was used to study the tissue distribution of SAR97276 in mouse as part of the ongoing development of SAR97276.  相似文献   

10.
11.
A new method based on ultrasonic slurry sampling atomic absorption spectrometry (AAS) was established for the determination of trace mercury in geological samples by use of recently developed mercury cold vapor generation using formic acid under ultraviolet (UV) irradiation. The generated mercury cold vapor was rapidly separated from the matrix and swept into a T-tube for the measurement of atomic absorbance. Under the optimal experimental conditions, up to 1000-fold of Cu(II), Co(II), Ni(II), Cr(VI), Mn(II), Fe(III), and Zn(II) caused no significant interference with the determination of 50 μg L−1 Hg. The limit of detection at sub-ppb level was obtained for mercury. The method was applied to the determination of mercury in geological samples with satisfactory results. Correspondence: Xiandeng Hou, College of Chemistry, Sichuan University, Chengdu, Sichuan 610064, China  相似文献   

12.
高效液相色谱-串联质谱法检测红葡萄酒中功效成分   总被引:1,自引:0,他引:1  
冯峰  程甲  粟有志  张峰  赵丹 《色谱》2017,35(2):178-184
建立了高效液相色谱-串联质谱法快速测定葡萄酒中白藜芦醇、黄酮类、多酚类功效成分的分析方法。葡萄酒样品直接稀释后进样,用C18柱进行分离,以乙腈-0.1%(体积分数)甲酸水溶液为流动相进行梯度洗脱,通过多反应监测(MRM)模式进行检测。13种功效成分在各自线性范围内呈良好的线性关系,相关系数均大于0.99。除表没食子儿茶素、没食子儿茶素、儿茶素没食子酸酯、花旗松素的检出限为1.0、1.0、3.0、3.0μg/L外,其他9种化合物的检出限均小于1.0μg/L。回收率为80.9%~112.3%,相对标准偏差小于10%。该方法快速、准确、灵敏度高,适用于葡萄酒中功效成分的快速分析。对实际样品的检测表明,所测葡萄酒样品中均含有儿茶素、表儿茶素、表没食子儿茶素、没食子儿茶素、表儿茶素没食子酸酯/儿茶素没食子酸酯、白藜芦醇、大豆黄素等功效成分,不同品种葡萄酒中这些功效成分含量差异显著。  相似文献   

13.
Fisher IP  Fischer P 《Talanta》1974,21(8):867-875
The major group types in petroleum streams may be analysed by high-resolution mass spectrometry. The method described here relies on a calibration matrix derived from the high-resolution spectra both of pure compounds and of cuts separated from petroleum. The analytical results have been assessed statistically for precision.  相似文献   

14.
A tripeptide, Asn-D-Trp-Phe-NH(2) (NdWFa) that contains a D-amino acid residue (i.e. D-tryptophan) was previously identified in Aplysia's central nervous system (CNS) and found to be cadioexcitatory. However, the occurrence of its diastereomers including NWFa, theoretically the precursor of NdWFa, remains largely unknown. In this work, a nanoscale liquid chromatographic/tandem mass spectrometric (nano-LC-MS/MS) method was developed for a sensitive determination of the diastereomers of NWFa. Resolution of the diastereomers including NWFa, NdWFa, NWdFa, and dNWFa was achieved on capillary columns packed with C(18) silica particles with an MS detection-friendly mobile phase consisting of water, acetonitrile, and formic acid. Columns of different internal diameters (IDs) ranging from 75 to 250 microm were evaluated to achieve the best sensitivity. With the use of a 75 microm ID column integrated with a nanoelectrospray emitter, the method had limits of detection (LOD) of 0.21 nM (or 0.49 pg on column, 5 microl injected) NdWFa in tissue homogenate (S/N = 3). The five major ganglia in Aplysia californica's CNS (i.e. buccal, cerebral, abdominal, plural, and pedal) were analyzed. NdWFa was detected only in abdominal ganglion at the ng/g tissue level. Further, its diastereomer, NWFa, was also detected for the first time and also only in abdominal ganglion at a significantly lower level. The levels of both NWFa and NdWFa varied from animal to animal in the range from 0 to 81 ng/g tissue. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

15.
A methodology has been developed and validated for quantifying 8-hydroxydeoxyguanosine (8-OHdG) in both commercial DNA and DNA isolated from livers of male Sprague-Dawley rats by liquid chromatography/positive atmospheric pressure photoionization tandem mass spectrometry. The analytical method conditions, including conditions for stabilizing 8-OHdG during complex nuclease P1 enzymatic digestion, were also evaluated. The limit of detection for 8-OHdG was 1.0 ng/mL (17.6 fmol on-column), and the linearity of the calibration curve was greater than 0.998 from 1.0 to 500 ng/mL. The intraday assay precision relative standard deviation (RSD) value for quality control (QC) samples was < or =5.59% with accuracies ranging from 91.84 to 117.61%. The interday assay precision (RSD) value was < or =1.76% with accuracies ranging from 91.84 to 116.67%. This method, combined with the LC/UV analysis of deoxyguanosine (dG), was used for determination of the levels of 8-OHdG/10(6) dG in DNA nuclease P1 enzymatic hydrolysates from both commercial DNA and rat liver DNA.  相似文献   

16.
Fluoroquinolone antibiotics are labeled for very limited veterinary use for treatment of some animals and pets, but they are not authorized for food animals in Canada, including egg-producing birds. Because they are approved for other animals, however, fluoroquinolones may appear in eggs through off-labeling or accidental use. This method is capable of quantitating and confirming the presence of 4 fluoroquinolones, ciprofloxacin, danofloxacin, enrofloxacin, and sarafloxacin, over the concentration range 1 to 60 microg/kg (ppb) using 2 internal standards, norfloxacin or lomefloxacin. The compounds are extracted with acidic acetonitrile, isolated using Oasis HLB solid-phase extraction, and quantitated by liquid chromatography/tandem mass spectrometry at 2 transitions. The limits of detection (microg/kg) were evaluated from between-day experiments as: ciprofloxacin, 0.22; danofloxacin (m/z 314), 0.32; enrofloxacin, 0.22; and sarafloxacin, 0.31. The values for the decision limit, CCalpha were 0.33, 0.36, 0.30, and 0.45 microg/kg, respectively.  相似文献   

17.
The direct sampling feature of liquid sample desorption electrospray ionization (DESI) allows the ionization of liquid samples without adding acids/organic solvents (i.e., without sample pretreatment). As a result, it provides a new approach for probing protein conformation in solution. In this study, it has been observed that native protein ions are generated from proteins in water by DESI. Interestingly, the intensities of the resulting protein ions appear to be higher than those generated by ESI of the proteins in water or in ammonium acetate. For protein solutions that already contain acids/organic solvents, DESI can be used to investigate the influences of these denaturants on protein conformations and the obtained results are in good agreement with spectroscopic data. In addition, online monitoring of protein conformational changes by DESI is feasible; for instance, heat-induced unfolding of ubiquitin can be traced with DESI in water without influences of organic solvents/acids. This DESI method provides a new alternative tool for the study of protein conformation in solution.  相似文献   

18.
A specific and sensitive method based on tandem mass spectrometry with on-line high-performance liquid chromatography using atmospheric pressure chemical ionisation (LC–APCI-MS–MS) for the quantitation of anabolic hormone residues (17β-19-nortestosterone, 17β-testosterone and progesterone) and their major metabolites (17-19-nortestosterone and 17-testosterone) in bovine serum and urine is reported. [2H2]17β-Testosterone was used as internal standard. The analytes were extracted from urine (following enzymatic hydrolysis) and serum samples by liquid–liquid extraction and purified by C18 solid-phase extraction. Ionisation was performed in a heated nebulizer interface operating in the positive ion mode, where only the protonated molecule, [M+H]+, was generated for each analyte. This served as precursor ion for collision-induced dissociation and two diagnostic product ions for each analyte were identified for the unambiguous hormone confirmation by selected reaction monitoring LC–MS–MS. The overall inter-day precision (relative standard deviation) ranged from 6.37 to 2.10% and from 6.25 to 2.01%, for the bovine serum and urine samples, respectively, while the inter-day accuracy (relative error) ranged from −5.90 to −3.18% and from −6.40 to −2.97%, for the bovine serum and urine samples, respectively. The limit of quantitation of the method was 0.1 ng/ml for all the hormones in bovine serum and urine. On account of its high sensitivity and specificity the method has been successfully used to confirm illegal hormone administration for regulatory purposes.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号