首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Pneumatically-assisted electrospray tandem mass spectrometry (ES MS/MS) was proposed as a technique for the identification of dimethylarsinoyl-riboside derivatives (arsenosugars) in seaweed (Laminaria). Conditions for the acquisition of MS and MS/MS spectra were optimized. A size-exclusion HPLC (SE HPLC) step was developed for the purification of algal extracts prior to ES MS. The arsenosugar fraction was found to elute prior to the majority of other arsenic compounds. The identity of the compounds expected to be arsenosugar compounds was confirmed by the collision induced dissociation (CID) of the relevant protonated molecule ions. An independent confirmation of the identity of analytes was obtained by two-dimensional (size-exclusion–anion exchange) HPLC–ICP MS with signal identification by spiking with the appropriate arsenosugar standards.  相似文献   

2.
The aim of this work was to develop a method for the characterization and determination of diuretics in human urine samples by liquid chromatography (LC) coupled to pneumatically assisted electrospray ionization (ES) mass spectrometry (MS). The diuretics studied were substances forbidden by the IOC such as trichlormethiazide, furosemide, canrenoic acid, benzthiazide, bendroflumethiazide, bumetanide, etacrynic acid and spironolactone. For this purpose, the operational parameters of electrospray, such as counter electrode voltage, capillary voltage, sample cone voltage and source temperature, were optimized in order to obtain the best signal stability and the highest sensitivity for the greatest number of diuretic agents. The optimized separation method was successfully coupled with the MS system to analyze the above-mentioned diuretics extracted from spiked urine samples by a liquid extraction and clean-up procedure at basic pH, using ethyl acetate as solvent and the salting-out effect (NaCl). The mass spectra obtained provide adequate information for identification purposes. Positive urine samples obtained from athletes were also analyzed. The presence of these substances in human urine was confirmed by this method, making LC/ES-MS an analytical tool to be considered in the area of antidoping control.  相似文献   

3.
Conclusions As demonstrated for the cortisol estimation in serum and urine, the principle of sample pretreatment applied in the present technique provides the almost complete concentration, the effective prepurification and the focussed transfer to liquid-chromatographic quantitation. It probably may present the technological basis for on-line estimation of all compounds that can be measured by liquid-chromatography.
Multidimensionale Flüssigkeits-Chromatographie zur Bestimmung von niedrigkonzentrierten Substanzen in biologischen Flüssigkeiten
  相似文献   

4.
A method has been developed and is described for the quantitative determination of a nonpeptide antithrombotic in dog plasma. The assay employs reversed phase microbore high-performance liquid chromatography in conjunction with tandem mass spectrometry utilizing pneumatically assisted electrospray ionization. The analyte and internal standard are isolated from the plasma matrix by solid-phase extraction. The mass spectrometer is operated in the positive ion multiple reaction monitoring mode and is set to detect the presence of a precursor-product ion pair for both the analyte and internal standard to generate product ion chromatograms for both species. The analyte is quantified by using weighted least-squares regression of the peak height ratio of drug:internal standard. The method provides linear response for plasma concentrations ranging from 5 ng/mL (25 pg on-column) to 2500 ng/mL. Statistical evaluation and examples of authentic sample assays are also presented.  相似文献   

5.
Triptorelin, a synthetic peptide hormone used in the treatment of prostate cancer by means of reduction in the action of male hormone testosterone, is studied here. The synthetic procedure commonly results in unwanted side products that require extensive purification and characterization of the synthesis mixture. The chromatographic separation of triptorelin from the crude mixture was developed by applying the linear solvation energy relationship (LSER) methodology previously developed, to optimize the composition of the mobile phase in order to avoid lengthy empirical optimization procedures. Electrospray ionization mass spectrometry coupled to liquid chromatography (LC/ES-MS) was used to obtain reliable information on the inevitable side products. The knowledge of the identity of these impurities allows fast optimization of the synthetic procedure and also the therapeutic use of triptorelin peptide hormone.  相似文献   

6.
An enantioselective gas chromatographic quantitation assay was developed for the enantiomers of dl-threo-methylphenidate in plasma and urine. dl-threo-Methylphenidate and the internal standard were acylated with N-heptafluorobutyryl-1-prolylchloride under Schotten-Baumann conditions prior to gas chromatographic separation on achiral mixed stationary phases. The derivatives were detected by means of a nitrogen-phosphorus detector. Linear and reproducible calibration curves were obtained over the concentration ranges 0.43-43.25 and 2.16-216.25 ng/ml enantiomer in plasma or urine, respectively. This enantioselective gas chromatographic quantitation assay was applied in a single oral dose disposition study of dl-threo-methylphenidate in a healthy adult volunteer. Stereoselective differences were observed in the plasma concentration-time profiles and cumulative urinary excretion profiles following oral doses of 20 and 40 mg of dl-threo-methylphenidate hydrochloride. Only d-threo-methylphenidate was detectable in plasma after 4 h.  相似文献   

7.
A dual electrospray ionization (ESI) source employed with hexapole accumulation and gated trapping provides a novel method of using an internal standard to achieve high mass accuracies in Fourier transform ion cyclotron resonance mass spectrometry. Two ESI emitters are sequentially positioned in front of the heated metal capillary inlet by a solenoid fitted to an XYZ micromanipulator; one emitter contains the analyte(s) of interest and the other an internal standard. A 5 V transistor-transistor logic pulse from the data station controls the solenoid by means of a solid-state relay so that matching of spectral peak intensities (i.e., analyte and internal standard intensities) can be accomplished by adjusting the hexapole accumulation time for each species. Polythymidine, d(pT)18, was used as the internal standard for all studies reported here. The absolute average error for an internally calibrated 15-mer oligonucleotide (theoretical monoisotopic mass = 4548.769 Da) was -1.1 ppm (external calibration: 41 ppm) with a standard deviation of +/-3.0 ppm (external calibration: +/-24 ppm) for a total of 25 spectra obtained at various hexapole accumulation time ratios. Linear least squares regression analysis was carried out and revealed a linear dependence of the magnitudes of the peak height ratios (analyte/internal standard) vs. hexapole accumulation time ratios (analyte/internal standard) which is described by the following equation: y = 0.45 x - 0.02. The fitted line had a %RSD of the slope of 28% with an R2 of 0.93. The applicability of this methodology was extended to a polymerase chain reaction product with a theoretical average molecular mass of 50,849.20 Da. With the internal standard, d(pT)18, an absolute average error of -8.9 ppm (external calibration: 44 ppm) based on five measurements was achieved with a standard deviation of 11 ppm (external calibration: +/-36 ppm), thus illustrating this method's use for characterizing large biomolecules such as those encountered in genomics and proteomics related research.  相似文献   

8.
A method is presented for the determination of bromine in biological fluids that demonstrates the possibility of adapting neutron activation analysis to large-scale, routine programs. By means of a simple and inexpensive semi-automated system radioactive bromine is separated from one hundred samples per day. A new procedure for determining bromine through measurement of the 36-keV γ-ray of80m Br has been developed and incorporated into this method. The advantages achieved with this multipurpose separation system and low-energy γ-spectrometry are demonstrated through analyses of urine, serum, plasma and saliva.  相似文献   

9.
10.
Summary In this paper we investigate the potential of alkyl-bonded silica monolithic columns for the isolation and identification of drug-related components in biological fluids. Up to 6 columns have been connected in series to produce a chromatographic system with up to 40,000 plates. This high-resolution chromatography system has been coupled to both MS and NMR to enable efficient detection and characterisation of drug-related components in biological fluids. The use of six coupled columns has been shown to give enhanced resolution over a high quality silica particulate column packed with 3 μm material which exhibits the same back pressure. The effect of volume and mass load on the performance of monolithic columns for semi-preparative chromatography of biological fluids has also been investigated. In these studies it was possible to inject up to 100 mL of neat urine with no loss of chromatographic performance. Furthermore, upon re-testing, the columns showed similar chromatographic performance. Again several columns were serially connected, producing enhanced resolution in the semi-preparative mode.  相似文献   

11.
Recent years have seen increasing usage of large particle size stationary phases and ultra-high flow rate liquid chromatography/mass spectrometry (LC/MS) for rapid determination of pharmaceuticals in plasma without prior sample preparation. This lack of sample preparation prior to analysis, together with the extremely high throughput of the chromatography, makes the technique extremely attractive to the bioanalyst. Further, the introduction of multiple sprayer interfaces to mass spectrometers provides the potential for even higher throughput. In this paper, we present parallel ultra-high flow rate liquid chromatography using four columns in parallel and a four-way multiple sprayer interface to the mass spectrometer. We have applied this on both the narrow-bore and capillary scale. This technique enables the quantification of drugs from four plasma samples simultaneously, at nanogram per millilitre concentrations, from small aliquots of plasma without sample preparation and with throughputs of up to 120 samples per hour.  相似文献   

12.
13.
19F-n.m.r. spectrometry is used as a direct method to assay simultaneously in body fluids (urine, plasma) all the fluorinated metabolites of a new antineoplastic drug fluoropyrimidine, 5′-deoxy-5-fluorouridine. The resonances of these metabolites are spread over a large spectral width (about 100 ppm). The calibration graphs for 5′-deoxy-5-fluorouridine and its major metabolite, α-fluoro-β-alanine, are linear over the range 10?5–10?1 M; the accuracy is 3–5% for urine samples and 5–7% for plasma samples. The method is applied to the determination of all the metabolites in urine from a patient.  相似文献   

14.
In this work, high-flow online reversed-phase extraction was coupled with normal phase on silica columns with aqueous-organic mobile phase liquid chromatography/tandem mass spectrometry (LC/MS/MS) to quantify drug candidates in biological fluids. The orthogonal separation effect obtained from this configuration considerably reduced matrix effects and increased sensitivity for highly polar compounds as detected by selected reaction monitoring. This approach also significantly improved the robustness and limit of detection of the assays. An evaluation of this system was performed using a mixture of albuterol and bamethan in rat plasma. Assay validation demonstrated acceptable accuracy (< 8% difference) and precision (< 6% CV) for these model compounds. The system has been used for the quantitation of polar ionic compounds in biological fluids in support of drug discovery programs. This assay was used to analyze samples for a BMS proprietary compound (A) in a rat pharmacokinetic study and is shown as an example to demonstrate the precision, accuracy, and sufficient sensitivity of this system.  相似文献   

15.
The aim of this article is to present a new procedure based on dual solid-phase microextraction (dSPME) for the simultaneous extraction of 16 pharmaceutical compounds with acidic and basic characteristics in urban wastewaters. Water samples are divided into two aliquots of 2 mL each extracted by two CW-TPR fibers at different pH values (pH 3 and 11) and with a NaCl concentration of 300 g L−1 at 75 °C for 30 min. The analytes in both fibers are desorbed one after the other in the desorption chamber in static mode with mobile phase for 10 min. The extracts are injected into an LC system coupled to an ion trap mass spectrometer, leading to the accurate quantification of 16 pharmaceutical compounds in wastewaters, in MS2 mode. All the target compounds found in wastewaters provide good signals corresponding to the protonated precursor ion [M+H]+. The parameters influencing adsorption and desorption of the analytes on fiber were optimized. The assessment of the analytical method was performed by studying the linearity (LOQ to 10 ng mL−1) and the intra- and interday accuracy (89.2–109.7%) and precision (RSD <13.6%). The quantification limits obtained ranged between 0.005 and 0.05 μg L−1. The application of the method to real samples proves its effectiveness in identifying and detecting naproxen, valsartan, bezafibrate, torasemide, diclofenac, carbamazepine, citalopram, lorazepan, fluoxetine, imipramine and amitriptyline in influent and effluent wastewater treatment plant samples.  相似文献   

16.
We developed a liquid chromatography/electrospray ionization tandem mass spectrometry method for the simultaneous quantitative determination of C18 sphingosine (Sph), C18 dihydrosphingosine (dhSph), C18 phytosphingosine (pSph), C18 sphingosine-1-phosphate (S1P), C18 dihydrosphingosine-1-phosphate (dhS1P), and C18 phytosphingosine-1-phosphate (pS1P). Samples were prepared by simple methanol deproteinization and analyzed in selected reaction monitoring modes. No peak tailing was observed on the chromatograms using a Capcell Pak ACR column (1.5 mm i.d. × 250 mm, 3 μm, Shiseido). The calibration curves of the sphingoids showed good linearity (r > 0.996) over the range of 0.050-5.00 pmol per injection. The accuracy and precision of this method were demonstrated using four representative biological samples (serum, brain, liver, and spleen) from mice that contained known amounts of the sphingoids. Samples of mice tissue such as plasma, brain, eye, testis, liver, kidney, lung, spleen, lymph node, and thymus were examined for their Sph, dhSph, pSph, S1P, dhS1P, and pS1P composition. The results confirmed the usefulness of this method for the physiological and pathological analysis of the composition of important sphingoids.  相似文献   

17.
The atmospheric pressure ionization (API) source for a commercial mass spectrometer was modified to operate as a dual source in both the electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) techniques by simultaneously utilizing the electrospray probe and the corona discharge needle. A switching box was designed to operate in either manual or programmable modes to permit rapid switching between ionization techniques without changing sources, probes, or breaking vacuum. The source can be operated using the following ionization techniques: ESI only, APCI only, ESI/APCI simultaneously, and ESI/APCI alternatingly. The optimum operating conditions for these ionization techniques were similar to the manufacturer’s original specifications except that the APCI flow rate was lower (~50 µL/min versus 1000 µL/min) and externally heated nebulizing gas was found to be desirable. A four-component mixture, introduced by flow injection, was used to demonstrate the versatility of the dual ESI/APCI source.  相似文献   

18.
In this paper, for the first time, surfactant‐assisted electromembrane extraction coupled with capillary electrophoresis with UV detector was introduced for the extraction of acidic drugs from biological fluids. In this technique, in the presence of the nonionic surfactant in the donor phase, tendency of analyte ions into the supported liquid membrane (SLM) was increased. Naproxen and diclofenac were selected as model acidic drugs. In order to obtain the best extraction efficiency, several factors influencing the extraction efficiency were investigated. Optimal extractions were accomplished with 1‐octanol as the SLM, 15 Volt dc potential as the driving force, pH 12 in acceptor solution, and 0.2 mmol/L Triton X‐100 with pH 7.4 in donor solution. Equilibrium extraction conditions were obtained after 15 min of operation where the whole assembly agitated at 1000 rpm. Under the optimized conditions, preconcentration factors in the range of 176–184 and recoveries in the range of 88–92% were obtained. The applied method offers acceptable linearity with correlation coefficients higher than 0.9992. Limits of detection of 1.51 ng/mL and 2.42 ng/mL were obtained for naproxen and diclofenac, respectively. Finally, the developed method was successfully applied for the determination of naproxen and diclofenac in different matrices including plasma and urine samples.  相似文献   

19.
The design and performance of an electrospray ion source for a high resolution magnetic sector mass spectrometer that utilizes a heated capillary has been presented. Low pressure, high sensitivity, stable electrospray, low flow rates, and low electronic noise were important factors in achieving high resolution electrospray mass spectrometry. A unit mass resolution has been achieved for biomolecules with MW > 12,000, and an accuracy of 1.4 ppm has been achieved for the average molecular weight of bovine insulin.  相似文献   

20.
The present work investigates various method development aspects for the quantitative analysis of pharmaceutical compounds in human plasma using matrix-assisted laser desorption/ionization and multiple reaction monitoring (MALDI-MRM). Talinolol was selected as a model analyte. Liquid-liquid extraction (LLE) and protein precipitation were evaluated regarding sensitivity and throughput for the MALDI-MRM technique and its applicability without and with chromatographic separation. Compared to classical electrospray liquid chromatography/mass spectrometry (LC/ESI-MS) method development, with MALDI-MRM the tuning of the analyte in single MS mode is more challenging due to interfering matrix background ions. An approach is proposed using background subtraction. With LLE and using a 200 microL human plasma aliquot acceptable precision and accuracy could be obtained in the range of 1 to 1000 ng/mL without any LC separation. Approximately 3 s were required for one analysis. A full calibration curve and its quality control samples (20 samples) can be analyzed within 1 min. Combining LC with the MALDI analysis allowed improving the linearity down to 50 pg/mL, while reducing the throughput potential only by two-fold. Matrix effects are still a significant issue with MALDI but can be monitored in a similar way to that used for LC/ESI-MS analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号