共查询到20条相似文献,搜索用时 15 毫秒
1.
A method based on micellar electrokinetic capillary chromatography (MECC) has been developed for the determination of shikimate in water and crude plant extracts. The analytes are separated in a cholate-taurine buffer by MECC at pH 7.3 and measured by direct UV detection at 206 nm. Shikimate showed linearity up to 12.5 mM, with a squared correlation coefficient (r(2)) of 0.9997. The method has concentration limit of detection (cLOD) and concentration limit of quantification (cLOQ) at 24.4 and 67.8 microM, respectively, corresponding to detection in the femtomol range. The number of theoretical plates (N) was estimated to 245,000 for the optimized system using a capillary with an effective length of 560 mm. The method was tested on plant samples by measuring the shikimate content in leaves of rapeseed plants grown in hydroponic solutions containing the herbicide glyphosate, a well-known inhibitor of the shikimate pathway. In crude extracts of these plants, shikimate was found to accumulate in the leaves, confirming earlier reports of shikimate as a potential biomarker for glyphosate treatment. The method now developed was also able to detect shikimate-3-phosphate, but this compound was not accumulated in glyphosate inhibited plants as found for shikimate. 相似文献
2.
J. D. Fontana M. Passos M. H. R. dos Santos C. K. Fontana B. H. Oliveira L. Schause R. Pontarolo M. A. Barbirato M. A. Ruggiero F. M. Lanças 《Chromatographia》2000,52(3-4):147-151
Summary There is no proportional correlation between increasing organic solvent polarity from hexane to methanol and the extractability
of propolis solids by the solvents or the bactericidal action of the propolis extracts obtained. Hexane (17.7%) and chloroform
(62.1%) were the poorest and the best extractants, respectively, for propolis solids. The antibiotic activity of the extracts
againstStaphylococcus strains decreased in the order hexane≥ethanol>methanol. Different capillary GC profiles were obtained for persilyl derivatives
of propolis extracted with hexane and methanol and for propolis collected in different Brazilian provinces, suggesting the
influence of flora variability on propolis composition. Wavelength-selected DAD detection revealed MEKC to be an innovative
and sensitive method for monitoring the occurrence in propolis of the flavonoids and phenolcarboxylic acids thought to be
responsible for the antimicrobial activity of propolis. 相似文献
3.
On-capillary sample concentration using sample stacking for the improvement of detection limits for various pesticides separated by micellar electrokinetic capillary chromatography was examined. The dependence of the stacking on different parameters was investigated. An approximately 30-fold preconcentration was achieved by applying sample stacking. Employing a two-step enrichment process (solid-phase extraction combined with sample stacking), detection limits were improved and the sample volume for SPE was reduced. In addition, the total time for the analysis was considerably reduced. Detection limits were between 0.01 and 0.1 ng/ml under these enrichment conditions. 相似文献
4.
Nine coumarins were successfully separated simultaneously using micellar electrokinetic capillary chromatography with 4-hydroxybenzoic acid as an internal standard. A carrier composed of buffer solution (20 mM sodium dodecyl sulfate-15 mM sodium borate-15 mM sodium dihydrogenphosphate)-acetonitrile (24:1) was found to be the most suitable electrolyte for this separation. The analysis time (22 min) was shorter than that using high-performance liquid chromatography (47 min). Contents of coumarins in the crude drug of Angelicae Tuhou Radix could be easily determined by the proposed method. 相似文献
5.
6.
A simple and rapid ( approximately 4 min) method for the measurement of iohexol in serum for assessing the glomerular filtration rate is described. It is based on direct serum injection on the capillary by MEKC. The method is linear between 8 and 260 mg/L, with an RSD of peak height of 2.9%. Several simple steps have contributed to an improved daily precision, such as choosing a high pH buffer, increasing the SDS concentration, frequent standardization, and eliminating any sample pretreatment. 相似文献
7.
Summary Computer-assisted procedures for the one-parameter optimization of the surfactant concentration and the concentration of urea or D-glucose as modifiers in micellar electrokinetic capillary chromatography have been developed. These procedures permit a rapid optimization of one parameter on the basis of only two experiments. Predicted values are compared to empirically obtained optimum values. The influence of the modifier concentration on the critical micelle concentration of sodium dodecyl sulfate was experimentally determined in buffers commonly employed in micellar electrokinetic chromatography. The alteration of retention factors of solutes caused by the influence of urea addition on the critical micelle concentration of sodium dodecyl sulfate was calculated under the assumption of constant distribution coefficients and compared to experimentally obtained values. It was demonstrated that the addition of urea or of D-glucose does not alter the phase ratio substantially. 相似文献
8.
Summary The separation of seven analogous anabolic steroids was studied by micellar electrokinetic capillary chromatography (MECC).
The retention order was found to be dependent on polarity. All of these steroids were well separated by the addition of organic
modifiers to the separation buffer. Of the organic modifiers tested, 1-propanol gave the best separation, better than methanol
or acetonitrile. 相似文献
9.
Analysis of water-soluble vitamins by micellar electrokinetic capillary chromatography 总被引:1,自引:0,他引:1
Seven water-soluble vitamins were determined simultaneously by micellar electrokinetic capillary chromatography with UV detection. All these compounds were separated from each other within ca. 22 min by using a carrier containing sodium dodecyl sulphate as the surfactant. On-column detection at 254 nm with ethyl p-aminobenzoate as the internal standard allowed sensitive, accurate and reproducible determination of these compounds. Five principal constituents of a vitamin injection were determined with relative standard deviations of less than 2.1%. 相似文献
10.
Charlotte Bjergegaard Henriette Simonsen Hilmer Srensen 《Journal of chromatography. A》1994,680(2):561-569
Micellar electrokinetic capillary chromatography (MECC) based on sodium cholate (NaCh) and sodium dodecyl sulphate (SDS) was developed for the determination of aromatic amino acids and heterocyclic legume constituents. The influence of temperature, voltage, micellar system, pH, zwitterion and modifier concentrations in the buffer on migration times, peak areas, resolution and number of theoretical plates was investigated. This MECC method makes possible the sensitive determination of the individual compounds with detection limits in the picomole range. Up to 300 000 theoretical plates per metre of capillary were obtained together with satisfactory linearity and repeatability of the NaCh method. The applicability of MECC to samples prepared from plant material, following a fast and simple technique of isolation, purification and group separation, is illustrated by selected examples. 相似文献
11.
The micellar electrokinetic capillary chromatography (MECC) method is reported for the separation of heparin, and for the possibility of direct determination of free heparin in plasma. The conditions for MECC were: pH 8.5, 25 mM sodium dodecyl sulfate (SDS), 25 mM borate buffer, with a 30 cmx50 mum ID fused-silica capillary. The sample was detected with a UV-detector at 270 nm with heparin as external standard. The recovery rate was 95.6-98.7%. This method was linear in the range 80-7000 U l(-1). The within-run and between-run relative standard deviations were lower than 3.1 and 4.5%, respectively. It is suggested that this MECC method may be used to determine blood samples containing high levels of heparin. 相似文献
12.
Summary A method for the separation of a number of herbicides consisting of chlorophenoxy acids by micellar electrokinetic capillary chromatography (MECC) was developed. Sodium dodecyl sulphate (SDS), Brij 35, cetyltrimethylammonium bromide (CTAB) and methanol were introduced into the buffers to investigate their effects on the separation of the herbicides. SDS combined with Brij 35 as the micellar agent was found to provide the best overall separation of these components. 相似文献
13.
M. A. Rodríguez-Delgado J. P. Pérez M. J. Sánchez F. J. García Montelongo 《Chromatographia》2000,52(5-6):289-294
Summary A group of flavonoids of special interest to wine quality were separated by micellar electrokinetic chromatography (MEKC) with diode array detection. Their separation was optimized as a function of the buffer concentration and pH, the concentration of sodium dodecyl sulfate (SDS) and the applied voltage. Selectivity and resolution of the solutes were increased by adding organic solvents to the separation buffer, the best results being obtained at lower concentrations. An optimized buffer with 5% methanol provided optimum separation with regard to efficiency, resolution and migration time. The optimized method was applied to the determination of these compounds in wine samples. 相似文献
14.
D F Swaile D E Burton A T Balchunas M J Sepaniak 《Journal of chromatographic science》1988,26(8):406-409
The potential utility in pharmaceutical analysis of a capillary electrokinetic separation technique that employs a micellar "pseudo-stationary phase" is discussed and illustrated. Chromatograms of separations of vitamin metabolites and derivatized amino acids are presented to illustrate the high efficiency of the technique and the ability to simultaneously separate the charged and neutral components of pharmaceutical samples. The analytical characteristics of the technique and the importance of optimizing experimental parameters, such as surfactant concentration and capillary column diameter, are discussed and demonstrated with the aid of chromatograms. 相似文献
15.
Arnica montana preparations have been used in Europe for centuries to treat skin disorders. Among the biologically active ingredients in the flower heads of the plant are sequiterpenes, flavonoids and phenolic acids. For the simultaneous determination of compounds belonging to the latter two groups a micellar electrokinetic capillary chromatography (MEKC) method was developed and validated. By using an electrolyte solution containing 50 mM borax, 25 mM sodium dodecyl sulfate and 30% of acetonitrile the separation of seven flavonoids and four caffeic acid derivatives was feasible in less than 20 min. The optimized system was validated for repeatability (σrel ≤ 4.4%), precision (inter-day σrel ≤ 8.13%, intra-day σrel ≤ 4.32%), accuracy (recovery rates from 96.8 to 102.4%), sensitivity (limit of detection (LOD) ≤ 4.5 μg mL−1) and linearity (R2 ≥ 0.9996), and then successfully applied to assay several plant samples. In all of them the most dominant flavonoid was found to be quercetin 3-O-glucuronic acid, whereas 3,5-dicaffeoylquinic acid was the major phenolic acid; the total content of flavonoids and phenolic acids varied in the samples from 0.60 to 1.70%, and 1.03 to 2.24%, respectively. 相似文献
16.
Anna-Francesca Lecoq Chiara Leuratti Erminio Marafante Sebastiano Di Biase 《Journal of separation science》1991,14(10):667-671
The use of micellar electrokinetic capillary chromatography (MECC) for the analysis of the major nucleobases, nucleosides, and nucleotides, and their chemically modified derivatives, has been developed and refined. The dimensions of the separating capillaries, the composition of the buffering systems, and the conditions used for electrophoresis were investigated in order to obtain the best performance. Particular emphasis was placed on the identification of the physiological constituents of nucleic acids and their chemically modified analogs: in vitro studies on calf thymus DNA exposed to genotoxic agents have demonstrated that adducted bases and nucleolides can be identified by MECC. 相似文献
17.
18.
A new analytical procedure using a two-step sample preconcentration (solid-phase extraction (SPE) and field-amplified sample stacking) prior to separation by micellar electrokinetic capillary chromatography was developed for the determination of 14 pesticides such as aldicarb, carbofuran, isoproturon, chlorotoluron, metolachlor, mecoprop, dichlorprop, MCPA, 2,4-D, methoxychlor, TDE, DDT, dieldrin, and DDE in drinking water. Good recoveries of pesticides were obtained using SPE with sample pH adjusted to 2-3. Field-amplified sample stacking was found to give enrichment factors up to 30-fold preconcentration of various pesticides under reversed polarity at -2 kV for 50 s. The optimized background electrolyte (BGE) consisted of 50 mM sodium dodecyl sulfate (SDS), 10 mM borate buffer, 15 mM beta-cyclodextrin (beta-CD), and 22% acetonitrile at pH 9.6, running was under 25 kV and detection at 202 nm. Good linearity was obtained for all pesticides with detection limits down to 0.04-0.46 ng/mL and a working range of 0.1-40 ng/mL. The repeatabilities of migration time and peak area were satisfactory with relative standard deviations (RSDs) between 0.66 and 13.6% and 4.1 and 28%, respectively. All pesticides except dieldrin were found to be detected at concentrations at least tenfold lower than the World Health Organization (WHO) guideline values. The analytical procedure developed offers an economic method for fast screening of multiple pesticide residues in drinking water for health protection. It had been applied to determine carbofuran and MCPA in agricultural run-off water samples, giving satisfactory repeatabilities of 10 and 12%, respectively, with n=5 for the determination of pesticides in contaminated water samples. 相似文献
19.
A fast and simple micellar electrokinetic capillary chromatographic method was developed for the analysis of piribedil in pharmaceutical formulations. The effects of buffer concentration, buffer pH, sodium dodecyl sulphate (SDS) concentration, organic modifier, applied voltage and injection time were investigated. Optimum results were obtained with a 50 mM borate buffer at pH 8.0 containing 50 mM SDS by using a fused silica capillary (50 m internal diameter, 72 cm effective length). The sample was injected hydrodynamically for 4 s at 50 mbar pressure and the applied voltage was +30 kV. The detection wavelength was set at 205 nm. Diflunisal was used as an internal standard. The analysis was performed at 25 °C and the total run time was 14 min. The method was suitably validated with respect to linearity range, limit of detection and quantification, precision, accuracy, specificity and robustness. The linear calibration range was 5–100 g mL–1 and the limit of detection was determined as 1 g mL–1. The method developed was successfully applied to the determination of piribedil in pharmaceutical formulations. The results were compared with a spectrophotometric method reported in the literature and no significant difference was found statistically. 相似文献