首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 796 毫秒
1.
This paper describes a rapid gas chromatographic/mass spectrometric (GC/MS) screening method for the detection of drugs of abuse and/or their metabolites in urine. Synthetic stimulants, opiates, cocaine metabolites, cannabinoids--and specifically the acid metabolite of tetrahydrocannabinol (THC-COOH)--can be simultaneously extracted by a single liquid/liquid separation step, at alkaline pH, and assayed as trimethylsilyl derivatives by GC/MS in SIM (selected ion monitoring) mode. All the analytes show a good linearity (R2 > 0.99 for most of the considered substances) in the range 25-1000 ng/mL, with a good reproducibility of both the retention times (CV% <0.7) and the relative abundances of the characteristic diagnostic ions (CV% <13). The limit of detection (LOD) of the method is 25 ng/mL of target compound in human urine for most of the substances investigated, 3 ng/mL for THC-COOH, and 10 ng/mL for norbuprenorphine. Validation of the method allows its application to different fields of forensic analytical toxicology, including antidoping analysis.  相似文献   

2.
A new and reliable two‐step liquid chromatography/tandem mass spectrometry (LC/MS/MS) method in combination with gas chromatography/mass spectrometry (GC/MS) for the screening and confirmation of adrafinil and its major metabolites, modafinil and modafinil acid, in human urine has been developed and validated. The method involved reversed‐phase C18 solid‐phase extraction (SPE) cartridge extraction and MS analysis by means of LC/MS/MS and GC/MS. The study illustrated that the ESI capillary temperature played a key role in the formation of the protonated molecule. The limits of detection (LODs) of the developed method for the three compounds were lower than the minimum required performance limit (MRPL) of the World Anti‐Doping Agency (WADA). The human urine samples obtained after the oral administration of modafinil and from the Beijing 2008 Olympic Games were analyzed by using the described method, which has also been successfully applied to routine analyses and the WADA Proficiency Test. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
A gas chromatographic/mass spectrometric (GC/MS) study aimed at identifying the metabolites of sibutramine (1-(4-chlorophenyl)-N,N-dimethyl-alpha-(2-methylpropyl)cyclobutanemethanamine) in urine is described. Urinary excretion of sibutramine metabolites following the oral administration of a single dose of sibutramine was followed by GC/MS analysis. After identification of the chromatographic signals corresponding to the six main urinary metabolites, the fragmentation pattern was studied in electron ionization (EI) mode after derivatization to the corresponding methyl and trimethylsilyl derivatives. Urine samples were pretreated according to a reference procedure (liquid/liquid separation, enzymatic hydrolysis, pre-concentration under a stream of nitrogen and derivatization, either under thermal incubation and by microwave irradiation). All sibutramine metabolites were excreted as glucuroconjugates, and retain the chiral carbon present in the sibutramine skeleton. The metabolites identified included mono-desmethylsibutramine (nor-sibutramine), bi-desmethylsibutramine (nor-nor-sibutramine), and the corresponding hydroxylated compounds, the hydroxylation taking place either on the cyclobutane or on the isopropyl chain. The excretion profiles of the different metabolites were also evaluated. From an analytical point of view, the method can be applied to different fields of forensic analytical toxicology, including anti-doping analysis. Although the lack of certified reference materials does not allow a precise determination of the limits of detection (LODs) of all the sibutramine metabolites, an estimation taking into account the response factor of similar compounds ensures that all metabolites are still clearly detectable in a range of concentrations between 10 and 50 ng/mL, thus satisfying the minimum required performance limits (MRPLs) of the World Anti-Doping Agency (WADA).  相似文献   

4.
Ephedrines are sympathomimetic amines which have central nervous system stimulating properties and, for this reason, some of them are forbidden in sport by the World Antidoping Agency (WADA). They are screened and quantitated in urine by several published techniques and confirmed by gas chromatography/mass spectrometry (GC/MS). In this paper, a simple and easy confirmation procedure for norpseudoephedrine, norephedrine, ephedrine and pseudoephedrine in human urine by GC/electron ionization (EI)‐MS is described. After the addition of diphenylamine as internal standard, a liquid‐liquid extraction procedure under alkaline conditions with tert‐butyl methyl ether was applied to the samples. The analytes were derivatized with acetone and pyridine to form the correspondent oxazolidine derivatives (acetonide). The EI mass spectra of all the studied substances have many diagnostic ions with relative abundance in accordance with WADA requirements and show great structural information content. The fragmentation of theses derivatives is discussed. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

5.
A fast liquid chromatographic/mass spectrometric (LC/MS/MS) screening method for the detection, in urine, of synthetic glucocorticoids, stimulants (formoterol, modafinil and mesocarb), anti-oestrogens (finasteride, exemestane, anastrozole, letrozole and formestane) and synthetic anabolic steroids (stanozolol, gestrinone and tetrahydrogestrinone) is described. All these drugs (and/or their urinary metabolites) can be simultaneously extracted by a single liquid/liquid extraction step, at alkaline pH, after enzymatic hydrolysis with beta-glucuronidase, and assayed in 7 min by LC/MS/MS using electrospray ionization in positive ion mode and multiple reaction monitoring as the acquisition mode. All compounds show good reproducibility of both the retention times (CV% <2%) and the relative abundances (CV% <10%). The limits of detection for the anti-oestrogens, glucocorticoids and steroids are in the range of 1-30 ng/mL, and for the stimulants are in the range of 100-200 ng/mL, thus satisfying the minimum required performance limits of the World Anti-Doping Agency.  相似文献   

6.
A GC/FID/MS method was developed for the identification and quantification of d-allethrin (DA) and its major impurities in commercial samples. Optimisation of the experimental conditions was carried out considering such important requirements as resolution, reproducibility, detection limits of 0.1% (m/m) for the impurities, and short analysis time. Under the optimised final conditions the method was validated for specificity, precision (CV% = 0.133 at 2.10 mg/mL and CV% = 0.035 at 3.00 mg/mL), linearity (0-3.00 microg injected), limits of detection (0.09 ng injected) and quantitation (0.28 ng injected), and robustness. The DA related impurities were identified by using a GC/MS method with ion trap mass detection and also by comparison with synthesised standards. The most abundant impurities were crysolactone, allethrolone, chrysanthemic acid, and chloro-derivatives of DA.  相似文献   

7.
Ephedrines have central nervous system stimulating properties and, for this reason, some of them are forbidden in sport by the World Antidoping Agency (WADA). They are screened and quantitated in urine by several published techniques and confirmed by gas chromatography/mass spectrometry (GC/MS). In this paper, a simple confirmation procedure for norpseudoephedrine, norephedrine, ephedrine and pseudoephedrine in human urine by GC/electron ionization (EI)-MS is described. After the addition of levallorphane as internal standard, a liquid-liquid extraction procedure under alkaline conditions with tert-butyl methyl ether was applied to the samples. The analytes were derivatized with acetic acid anhydride and N-methyl-N-trimethylsilyltrifluoroacetamide to form N-acetyl-O-trimethylsilyl derivatives. The EI mass spectra of all the studied substances have many diagnostic ions with relative abundance in accordance with WADA requirements and show great structural information content. A curious migration of the trimethylsilyl group is proposed.  相似文献   

8.
A method for the toxicological screening of the new designer drug methylenedioxypyrovalerone (MDPV) is described; with an emphasis on its application for anti‐doping analysis. The metabolism of MDPV was evaluated in vitro using human liver microsomes and S9 cellular fractions for CYP450 phase I and uridine 5′‐diphosphoglucuronosyltransferase (UGT) and sulfotransferase (SULT) phase II metabolism studies. The resulting metabolites were subsequently liquid/liquid extracted and analyzed using gas chromatography/mass spectrometry (GC/MS) as trimethylsilyl (TMS) derivatives. The structures of the metabolites were further confirmed by accurate mass measurement using a liquid chromatography/quadrupole time‐of‐flight (LC/QTOF) mass spectrometer. The studies demonstrated that the main metabolites of MDPV are catechol and methyl catechol pyrovalerone, which are in turn sulfated and glucuronated. The method for the determination of MDPV in urine has been fully validated by assessing the limits of detection and quantification, linearity, repeatability, and accuracy. This validation demonstrates the suitability for screening of this stimulant substance for anti‐doping and forensic toxicology purposes. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
The potentials of different chromatography–mass spectrometry methods for the determination of alkyl methylphosphonic acids (AMPAs)—the chemical markers of nerve agents in urine—are compared. The gas chromatography–mass spectrometry (GC–MS) characteristics of various volatile AMPA derivatives are studied. The preference of perfluorobenzyl derivatives over methyl, trimethylsilyl and tert-butyldimethylsilyl esters for the GC–MS determination of AMPAs in urine is demonstrated. An optimal technique for the determination of AMPAs in urine is HPLC combined with high-resolution MS2 mass spectrometry with the isotope–labeled forms of target compounds as internal standards. The detection limits of AMPAs in the proposed analytical procedures vary from 0.1 to 1.0 ng/mL.  相似文献   

10.
A sensitive and selective method for the simultaneous determination of a spectrum of trichothecenes in residuals of biogas production has been developed. It comprises sample clean-up by liquid/liquid partition for digested manure and solid phase extraction for digested solid phase. Quantification of A- and B-type trichothecenes as their trifluoroacetyl derivatives is performed by gas chromatography mass spectrometry (GC/MS), that of B-type trichothecenes alternatively by high-performance liquid chromatography (HPLC). Fluorescence detection (FLD) after post-column derivatisation using methylacetoacetate and ammonium acetate after alkaline decomposition of toxins was applied. Detection limits in digestates were between 1 and 30 microg/l and 20 and 50 microg/l for GC/MS and HPLC/FLD, respectively. Recovery rates were between 52 and 129% for GC/MS detection with the exception of T-2 tetraol with 22%, and between 56 and 123% for HPLC/FLD.  相似文献   

11.
A new and simple APPI interface employing commercially available hardware is used to combine GC to MS. The feasibility of the method is demonstrated in the analysis of urine samples for neurosteroids as their trimethylsilyl (TMS) derivatives. The effect of different dopants (chlorobenzene, toluene, anisole) on the ionization of the TMS derivatives was investigated. With chlorobenzene, the TMS derivatives produced intense molecular ions with minimal fragmentation, and chlorobenzene was selected as best dopant. Protonated molecules in addition to intense molecular ions were produced with toluene and anisole. The performance of the method was verified in the analysis of human urine samples. Chromatographic performance was good with peak half-widths of 3.6–4.3 s, linearity (r2 > 0.990) was acceptable, limits of detection (LODs) were in the range of 0.01–10 ng mL−1, and repeatability was good with relative standard deviations (rsd%) below 22%. The results show that the method is well suited for the determination of neurosteroids in biological samples.  相似文献   

12.
A new screening procedure for 18 narcotics in urine for anti-doping purposes has been developed using liquid chromatography/triple quadrupole mass spectrometry (LC/MS). Electrospray ionization (ESI) was used as interface. Infusion experiments were performed for all substances to investigate their mass spectrometric behaviour in terms of selecting product specific ions. These product ions were then used to develop a tandem mass spectrometric method using selected reaction monitoring (SRM). For the LC/MS analysis, chromatography was performed on an octadecylsilane column. The total run time of the chromatographic method was 5.5 min. For the sample preparation prior to LC/MS analysis, the urine samples were liquid-liquid extracted at pH 9.5 after overnight enzymatic hydrolysis. Two extraction solvents were evaluated: dichloromethane/methanol 9/1 (v/v), which is currently used for the extraction of narcotics, and diethyl ether, used for the extraction of steroids. With diethyl ether the detection limits for all compounds ranged between 0.5 and 20 ng/mL and with the mixture containing dichloromethane the detection limits ranged between 0.5 and 10 ng/mL. Taking into account the minimum required performance limits of the World Anti-Doping Agency of 200 ng/mL for narcotics, diethyl ether can also be considered as extraction solvent for narcotics. Finally, the described method was applied to the analysis of urine samples previously found to contain narcotics by our routine gas chromatography/mass spectrometry (GC/MS) method.  相似文献   

13.
Testosterone (T) is the primary male sex hormone. In addition to the development of secondary sex characteristics, testosterone has anabolic effects including increases in muscle size and strength and increases in lean body mass, making it an attractive candidate to enhance athletic performance. In the case of exogenous administration of testosterone, the ratio of testosterone to its isomer, epitestosterone (E), is elevated. WADA has set a standard for T/E ratios of 4.0 as indicative of possible exogenous testosterone administration. Typically, a sample that screens for a T/E ratio above that threshold is then subjected to quantitative confirmation by GC/MS. This methodology, however, can limited due to sensitivity issues as well as a limited number of qualifying ions that can be used for unambiguous identification. We have developed a confirmation method which uses liquid/liquid extraction, followed by room temperature Girard P derivatization, and analysis using LC/MS-ToF. We observe a number of advantages over conventional GC/MS analysis. Analysis time is decreased. Sensitivity is increased, resulting in limits of detection of 2 and 0.5 ng/ml for testosterone and epitestosterone, respectively. The number of diagnostic qualifier ions is also increased allowing more confident identification of the analytes. Finally, while this method has been developed on a QToF instrument, it should be easily transferable to any tandem LC/MS/MS system.  相似文献   

14.
The authors' laboratory at one time employed four liquid chromatography/mass spectrometric (LC/MS) methods for the detection of a large variety of drugs in equine urine. Drug classes covered by these methods included anti-diabetics, anti-ulcers, cyclooxygenase-2 (COX-2) inhibitors, sedatives, corticosteroids, anabolic steroids, sulfur diuretics, xanthines, etc. With the objective to reduce labour and instrumental workload, a new ultra performance liquid chromatography/tandem mass spectrometric (UPLC/MS/MS) method has been developed, which encompasses all target analytes detected by the original four LC/MS methods. The new method has better detection limits than the superseded methods. In addition, it covers new target analytes that could not be adequately detected by the four LC/MS methods. The new method involves solid-phase extraction (SPE) of two aliquots of equine urine using two Abs Elut Nexus cartridges. One aliquot of the urine sample is treated with β-glucuronidase before subjecting to SPE. A second aliquot of the same urine sample is processed directly using another SPE cartridge, so that drugs that are prone to decomposition during enzyme hydrolysis can be preserved. The combined eluate is analysed by UPLC/MS/MS using alternating positive and negative electrospray ionisation in the selected-reaction-monitoring mode. Exceptional chromatographic separation is achieved using an UPLC system equipped with a UPLC(?) BEH C18 column (10 cm L×2.1 mm ID with 1.7 μm particles). With this newly developed UPLC/MS/MS method, the simultaneous detection of 140 drugs at ppb to sub-ppb levels in equine urine can be achieved in less than 13 min inclusive of post-run equilibration. Matrix interference for the selected transitions at the expected retention times is minimised by the excellent UPLC chromatographic separation. The method has been validated for recovery and precision, and is being used regularly in the authors' laboratory as an important component of the array of screening methods for doping control analyses of equine urine samples.  相似文献   

15.
This paper describes a liquid chromatographic/tandem mass spectrometric (LC/MS–MS) method specifically designed for the screening of synthetic glucocorticosteroids in human urine. The method is designed to recognize a common mass spectral fragment formed from the particular portion of the molecular structure that is common to all synthetic glucocorticosteroids and that is fundamental to their pharmacological activity. As such, the method is also suitable for detecting unknown substances, provided they contain the portion of the molecular structure selected as the analytical target. The effectiveness of this approach was evaluated on seventeen synthetic glucocorticosteroids. Urine samples, including blank urines spiked with one or more synthetic glucocorticosteroids, were treated according to a standard procedure (enzymatic hydrolysis, liquid/liquid extraction and evaporation to dryness) and analyzed using LC/MS-MS with electrospray ionization (ESI). MS–MS acquisition was carried out in a precursor ion scan, and the results were compared with those obtained by a previously developed reference technique based on acquisition in the multiple reaction monitoring (MRM) mode. All of the glucocorticosteroids considered in this study are clearly detectable in urine, with a limit of detection in the concentration range 5–20 ng/mL, depending on the glucocorticosteroid structure. The proposed method is therefore suitable for the detection of glucocorticosteroids in urine samples taken for “in competition” sport anti-doping control tests, matching the requirements of the World Anti-Doping Agency (WADA) for accredited anti-doping laboratories. Figure Structures of the synthetic glucocorticoids considered in this study  相似文献   

16.
The urinary metabolism of the irreversible aromatase inhibitor androsta‐1,4,6‐triene‐3,17‐dione was investigated. It is mainly excreted unchanged and as its 17β‐hydroxy analogue. For confirmation, 17β‐hydroxyandrosta‐1,4,6‐trien‐3‐one was synthesized and characterized by nuclear magnetic resonance (NMR) in addition to the parent compound. In addition, several reduced metabolites were detected in the post‐administration urines, namely 17β‐hydroxyandrosta‐1,4‐dien‐3‐one (boldenone), 17β‐hydroxy‐5β‐androst‐1‐en‐3‐one (boldenone metabolite), 17β‐hydroxyandrosta‐4,6‐dien‐3‐one, and androsta‐4,6‐diene‐3,17‐dione. The identification was performed by comparison of the metabolites with reference material utilizing gas chromatography/mass spectrometry (GC/MS) of the underivatized compounds and GC/MS and GC/tandem mass spectrometry (MS/MS) of their trimethylsilyl (TMS) derivatives. Alterations in the steroid profile were also observed, most obviously in the androsterone/testosterone ratio. Even if not explicitly listed, androsta‐1,4,6‐triene‐3,17‐dione is classified as a prohibited substance in sports by the World Anti‐Doping Agency (WADA) due to its aromatase‐inhibiting properties. In 2006 three samples from human routine sports doping control tested positive for metabolites of androsta‐1,4,6‐triene‐3,17‐dione. The samples were initially found suspicious for the boldenone metabolite 17β‐hydroxy‐5β‐androst‐1‐en‐3‐one. Since metabolites of androst‐4‐ene‐3,6,17‐trione were also present in the urine samples, it is presumed that these findings were due to the administration of a product like ‘Novedex Xtreme’, which could be easily obtained from the sport supplement market. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

17.
This paper presents a general screening method, based on liquid chromatography/mass spectrometry (LC/MS), for the simultaneous detection in human urine of 72 xenobiotics (21 diuretics, 16 synthetic glucocorticoids, 17 beta-adrenergic drugs, 10 stimulants, 5 anti-oestrogens and 3 anabolic steroids), excreted free or as glucuro-conjugates in urine. Although the method has been specifically designed and evaluated in view of its potential application to anti-doping analyses, it can also be effective in other areas of analytical toxicology. Sample preparation was based on two liquid/liquid separation steps (performed at alkaline and at acid pH, respectively) of hydrolyzed human urine, and then an assay by LC/MS-MS in positive and negative ionization mode using an electrospray ionization source (ESI) and multiple reaction monitoring (MRM) as the acquisition mode. The overall time needed for an LC run was less than 15 minutes. All compounds showed good reproducibility in terms of both the retention times (CV%<1) and the relative abundances of the diagnostic transitions (CV%<10). The limits of detection (LOD) were in the range of 1–50 ng/mL for glucocorticoids, anti-oestrogens and steroids, and 50–500 ng/mL for diuretics, beta-adrenergic drugs and stimulants, thus satisfying the minimum required performance limits (MRPL) set by the World Anti-Doping Agency (WADA) for the accredited anti-doping laboratories.  相似文献   

18.
Fluoxymesterone, an anabolic steroid with the 17alpha-methyl,17beta-hydroxy group, has been developed as an oral formulation for therapeutic purposes. However, it is also used illegally in racehorses to enhance racing performance. In this study, we detected 9alpha-fluoro-17,17-dimethyl-18-norandrostane-4,13-dien-11beta-ol-3-one by gas chromatography/mass spectrometry (GC/MS), which has not been reported as a fluoxymesterone metabolite so far in horse. It was synthesized for use as a reference standard, and characterized on the basis of (1)H NMR and (13)C NMR spectra, as well as GC/MS EI mass spectra of TMS derivatives. It was excreted as the main metabolite in horse urine, and its reference standard could be synthesized easily. Therefore, this metabolite could be a useful target for a doping test of fluoxymesterone in racehorses.  相似文献   

19.
Trimethylsilylation of anabolic agents and their metabolites is frequently achieved by using the derivatization mixture N-methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA)/NH(4)I/2-mercaptoethanol. Nevertheless, artifacts were formed when this mixture was employed in the monitoring of exemestane and its main metabolite 17β-hydroxyexemestane prior to GC-MS analysis. These artifacts were identified as the N-methyltrifluoroacetamide (MTFA) and trimethylsiloxyethylmercapto products of the respective trimethylsilyl (TMS) derivatives. Furthermore, artifact formation was evaluated taking the structure (1,4-diene-3-keto-6-exomethylene) of the compounds into account. Although these artifacts are relevant for investigations regarding the derivatization process and may be of interest in many fields, they are detrimental to cope with the requirements of the World Anti-Doping Agency (WADA) in terms of the limits of detection (LODs) required. To overcome this issue, a method using an alternative derivatization was proposed: formation of methyloxime-TMS derivatives through double derivatization using O-methylhydroxylamine/pyridine and MSTFA/TMS imidazole after enzymatic hydrolysis and liquid-liquid extraction. Samples from an excretion study after administration of exemestane to healthy volunteers were analyzed by the proposed method and detection of both exemestane and its main metabolite was possible. This method showed excellent results for both analytes meeting the LODs required for antiestrogenic agents (50 ng/mL) established by WADA. The method was validated for the main metabolite, it was robust and cost-effective for qualitative and quantitative purposes, with LOD and LOQ of 10 ng/mL and 25 ng/mL, respectively.  相似文献   

20.
Anabolic androgenic steroids (AAS) are metabolized extensively in the human body, resulting mainly in the formation of glucuronide conjugates. Current detection methods for AAS are based on gas chromatographic/mass spectrometric (GC/MS) analysis of the hydrolyzed steroid aglycones. These analyses require laborious sample preparation steps and are therefore time consuming. Our interest was to develop a rapid and straightforward method for intact steroid glucuronides in biological samples, using liquid-phase microextraction (LPME) sample clean-up and concentration method combined with liquid chromatographic/tandem mass spectrometric (LC/MS/MS) analysis. The applicability of LPME was optimized for 13 steroid glucuronides, and compared with conventional liquid-liquid extraction (LLE) and solid-phase extraction (SPE) procedures. An LC/MS/MS method was developed for the quantitative detection of AAS glucuronides, using a deuterium-labeled steroid glucuronide as the internal standard. LPME, owing to its high specificity, was shown to be better suited than conventional LLE and SPE for the clean-up of urinary AAS glucuronides. The LPME/LC/MS/MS method was fast and reliable, offering acceptable reproducibility and linearity with detection limits in the range 2-20 ng ml(-1) for most of the selected AAS glucuronides. The method was successfully applied to in vitro metabolic studies, and also tested with an authentic forensic urine sample. For a urine matrix the method still has some unsolved problems with specificity, which should be overcome before the method can be reliably used for doping analysis, but still offering additional and complementary data for current GC/MS analyses.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号