首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A DNA biosensor is presented that is based on gold interdigitated nanoelectrodes of 100 nm width and 250 nm pitch. A single-strand oligonucleotide acts as the capture probe. Because of its nanometer dimensions, the device shows improved sensitivity when compared to similar systems. This encouraged us to perform a direct and unlabelled detection. After incubation with the DNA target, the impedance spectrum was recorded between 1 kHz and 10 MHz to obtain the net capacitance change. The use of a biotinylated DNA signalling probe permitted the integration of an amplification stage in a sandwich format that employs streptavidin-modified gold nanoparticles. The strategy was preliminarily tested by detecting the breast cancer related BRCA1 gene, where the noncomplementary, wild and mutated forms were easily differentiated at a concentration level of 3 μM (corresponding to a 30 pmol quantity).  相似文献   

2.
Cadmium and nickel ions have been preconcentrated on Geobacillus thermoleovorans subsp. stromboliensis, immobilized on Amberlite XAD-4, and were determined by flame atomic absorption spectrometry (FAAS). Parameters such as pH, amount of adsorbent, eluent type and volume, flow rate of solution and the matrix interference effect on retention have been studied, and extraction conditions were optimized. Elution of Cd(II) and Ni(II) from minicolumns was carried out with 1.0 M hydrochloric acid or nitric acid with recoveries from 97 to 100%. The sorption capacity is 0.0373 and 0.0557 mmol g?1 for Cd(II) and Ni(II), respectively. The detection limits were 0.24 μg L?1 for cadmium and 0.3 μg L?1 for nickel. The relative standard deviations of the procedure were below 10%. The procedure was validated by analyzing certified reference materials and applied to the determination of Cd(II) and Ni(II) in natural water and food samples.  相似文献   

3.
Amberlite XAD-4 resin has been functionalized with succinic acid by coupling it with dibromosuccinic acid after acetylation. The resulting resin has been characterized by FT-IR, elemental analysis and TGA and has been used for preconcentrative separation of uranium(VI) from host of other inorganic species prior to its determination by spectrophotometry. The optimum pH value for quantitative sorption of uranium(VI) in both batch and column modes is 4.5-8.0 and desorption can be achieved by using 5.0 ml of 1.0 mol l−1 HCl. The sorption capacity of functionalized resin is 12.3 mg g−1. Calibration graphs were rectilinear over the uranium(VI) concentrations in the range 5-200 μg l−1. Five replicate determinations of 50 μg of uranium(VI) present in 1000 ml of solution gave a mean absorbance of 0.10 with a relative standard deviation of 2.56%. The detection limit corresponding to three times the standard deviation of the blank was found to be 2 μg l−1. Various cationic and anionic species at 200-fold amounts do not interfere during the preconcentration of 5.0 μg of uranium(VI) present in 1000 ml (batch) or 100 ml (column) of sample solution. Further, adsorption kinetic and isotherm studies were also carried out by a batch method to understand the nature of sorption of uranium(VI) with the succinic acid functionalized resin. The accuracy of the developed solid phase extractive preconcentration method in conjunction with Arsenazo III procedure was tested by analyzing marine sediment (MESS-3) and soil (IAEA soil-7) reference material. Further, the above procedure has been successfully employed for the analysis of soil and sediment samples.  相似文献   

4.
Summary Solvent extraction of uranium-sodium diethyldithiocarbamate with ethylmethyl ketone and separation from titanium, zirconium, thorium, lanthanum and cerium has been described. It has been found that 11.75 to 47.00 mg of uranium can be extracted from a binary mixture containing 4.78 to 19.04 mg of titanium, 9.12 to 36.48 mg of zirconium, 116.0 to 460.0 mg of thorium, 6.95 to 27.8 mg of lanthanum or 7.06 to 28.24 mg of cerium at pH 3.0. The pH range between which the separations may be carried out successfully is 2.0 to 3.5. The following cations interfere in the separations: CuII, FeIII, CoII, BiIII, NiII, CrVI, TeIV, SeIV, AgI, HgII, AsIII, SnIV, PbIV, CdII, MoVI, MnII, VV, ZnII, InIII, TlI, WVI, OsVIII and NbV.
Zusammenfassung Uran kann durch Extraktion als Diäthyldithiocarbamidat mit Methyläthylketon von Ti, Zr, Th, La oder Ce getrennt werden. Der günstigste pH-Bereich liegt zwischen 2,0 und 3,5. Die Trennungen wurden mit folgenden Mengen durchgeführt: U (11,75–47,00 mg); Ti (4,78 bis 19,04 mg), Zr (9,12–36,48 mg) Th (116,0–460,0 mg), La (6,95–27,8 mg), Ce (7,06–28,24 mg). Folgende Ionen verursachen Störungen: CuII, FeIII, CoII, BiIII, NiII, CrVI, TeIV, SeIV, AgI, HgII, AsIII, SnIV, PbIV, CdII, MoVI, MnII, VVI, ZnII, InIII, TlI, WVI, OsVIII sowie NbV.
  相似文献   

5.
A novel method for the selective electromembrane extraction (EME) of U6+ prior to fluorometric determination has been proposed. The effect of extraction conditions including supported liquid membrane (SLM) composition, extraction time and extraction voltage were investigated. An SLM composition of 1% di-2-ethyl hexyl phosphonic acid in nitrophenyl octyl ether (NPOE) showed good selectivity, recovery and enrichment factor. The best performance was achieved at an extraction potential of 80 volts and an extraction time of 14 minutes Under the optimized conditions, a linear range from 1 to 1000 ng mL−1 and LOD of 0.1 ng mL−1 were obtained for the determination of U6+. The EME method showed good performance in sample cleanup and the reduction of the interfering effects of Mn2+, Zn2+, Cd2+, Ni2+, Fe3+, Co2+, Cu2+, Cl and PO43− ions during fluorometric determination of uranium in real water samples. The recoveries above 54% and enrichment factors above 64.7 were obtained by the proposed method for real sample analysis.  相似文献   

6.
U(VI) sorption from nitric media using Cyanex272 impregnated on Amberlite XAD-2 resin has been studied using batch method. The influence of different experimental parameter such as aqueous acidity, effect of time, influence of eluting agents on U(VI) uptake was evaluated. The maximum sorption capacity of 0.168?mmol?g?1 of U(VI) evaluated based upon these studies. Sorption of U(VI) follows both the Langmuir and Freundlich adsorption isotherms.  相似文献   

7.
Narin I  Tuzen M  Soylak M 《Talanta》2004,63(2):411-418
A chelating resin, pyrocatechol violet (PV) immobilised on an Amberlite XAD-1180 support, was prepared and its use for the atomic absorption spectrometric determination of aluminium was investigated. The XAD-1180-PV resin was characterised by infrared spectrometry and thermal gravimetric analysis. The optimum pH value for quantitative sorption is 8-9, and desorption can be achieved by using 5.0-10.0 ml of 2 M HCl. The effects of diverse ions on the sorption and recovery of aluminium have been studied. The capacity of sorbent was 6.45±0.59 mg g−1 Al XAD-1180-PV. Recoveries for aluminium from water samples were in the range 95-105%. The accuracy of procedure was confirmed by aluminium determination in certified reference materials. The method developed was applied with varying results to the analysis of natural water, haemodialysis fluids and microwave digested red wine samples from Tokat City.  相似文献   

8.
Merdivan M  Düz MZ  Hamamci C 《Talanta》2001,55(3):639-645
The sorption of U(VI) by N, N-dibutyl, N'-benzoylthiourea (DBBT) impregnated resin has been studied. DBBT impregnated resin was prepared by direct adsorption of chelating ligand onto macroporous support, Amberlite XAD-16. The adsorption of DBBT on the macroporous support is shown by FTIR spectroscopy to be the result of only weak chelating ligand-support interactions. Parameters such as the pH effect on the sorption of uranium, the sorption capacity of the impregnated resin, the stripping of uranium and the effect of coexisting ions were investigated by batch experiments. The results demonstrated that uranium(VI) ions, at pH 4.5-7 could be sorbed completely using 0.1 g Amberlite XAD-16 resin loaded with DBBT. The sorption capacity of the impregnated resin is 0.90 mmol uranium(VI) g(-1). Quantitative recovery of U(VI) is achieved by stripping with 0.1 M HNO(3). The method was applied to the determination of uranium in synthetic samples. The precision of the method was 2.4 RSD% in a concentration of 1.20 mug ml(-1) for ten replicate analysis.  相似文献   

9.
The use of chemically modified XAD-4-salen chelating resin had been studied for the separative concentration of metal ions from an aqueous solution. XAD-4-salen was synthesized by diazonium coupling reaction of salen[N,N′-bis(salicylidene)ethylenediamine] and Amberlite XAD-4 resin. The distribution coefficient at various pH values and adsorption capacities were obtained with respect to Cu(II), Pb(II) and Bi(III). Trace elements were pre-concentrated on the synthesized XAD-4-salen by batch method for atomic absorption spectrometric determination. Some conditions, such as the pH of aqueous solution, amount of XAD-4-salen, kinds and concentration of acids were optimized for the analytical application of XAD-4-salen. For the pre-concentration of metal ions, the pH of the aqueous solution was adjusted to approximately 5.5, and then it was stirred 30 min after the addition of 50 mg of pulverized XAD-4-salen. The adsorbed metal ions were desorbed by 10 mL of 1.0 M HNO3. The desorption efficiency of Bi(III) was enhanced by the addition of 30 mg/L of Pd(II). The addition of Pd(II) as a matrix modifier could improve the reproducibility and sensitivity in the Atomic Absorption Spectroscopy (AAS) determination of volatile lead and bismuth. In the present study, this procedure has been applied for the determination of Cu(II), Pb(II) and Bi(III) in real samples of five kinds of river water, using a standard calibration curve method. Recoveries of 85–120% were obtained in the spiked samples in which given amount of analytes were added.  相似文献   

10.
A simple and sensitive method for the determination of ultra trace amounts of U(VI) and Th(IV) ions by spectrophotometric method after solid-phase extraction on a new extractant-impregnated resin (EIR) has been reported. The new EIR was synthesised by impregnating a weakly polar polymeric adsorbent, Amberlite XAD-7, with titan yellow (TY) as extractant. The analytical method is based on the simultaneous adsorption of analyte ions in a mini-column packed with TY/XAD-7 and performing sequential elution with 0.5% (w/v) Na2CO3 for uranium and 2.0 M HCl for thorium. The influences of the analytical parameters including pH, salting out agent and sample volume were investigated. The interference effects of foreign ions on the retention of the analyte ions were also explored. The limits of detection for U(VI) and Th(IV) were as low as 50 and 25 ng L?1, respectively. Relative standard deviations (n = 7) for U(VI) and Th(IV) were 3.1% and 2.9%, respectively. The method was successfully applied to the determination of ultra trace amounts of U(VI) and Th(IV) in different real matrices including industrial wastewater samples and environmental waters. The proposed method was validated using three certified reference materials and the results were in good agreement with the certified values.  相似文献   

11.
Baytak S  Türker AR 《Talanta》2005,65(4):938-945
A microorganism Agrobacterium tumefacients as an immobilized cell on a solid support was presented as a new biosorbent for the enrichment of Fe(III), Co(II), Mn(II) and Cr(III) prior to flame atomic absorption spectrometric analysis. Amberlite XAD-4 was used as a support material for column preconcentration. Various parameters such as pH, amount of adsorbent, eluent type and volume, flow rate of sample solution, volume of sample solution and matrix interference effect on the retention of the metal ions have been studied. The optimum pH for the sorption of above mentioned metal ions were about 6, 8, 8 and 6, respectively. The loading capacity of adsorbent for Co(II) and Mn(II) were found to be 29 and 22 μmol g−1, respectively. The recoveries of Fe(III), Co(II), Mn(II) and Cr(III), under the optimum conditions were found to be 99 ± 3, 99 ± 2, 98 ± 3 and 98 ± 3%, respectively, at the 95% confidence level. The limit of detection was 3.6, 3.0, 2.8 and 3.6 ng ml−1 for Fe(III), Co(II), Mn(II) and Cr (III), respectively, by applying a preconcentration factor of 25. The proposed enrichment method was applied for metal ion determination from water samples, alloy samples, infant foods and certified samples such as whey powder (IAEA-155) and aluminum alloy (NBS SRM 85b). The analytes were determined with a relative error lower than 10% in all samples.  相似文献   

12.
Dev K  Pathak R  Rao GN 《Talanta》1999,48(3):579-584
The complexing properties (capacity, pH effect, breakthrough curve) of a chelating resin, containing bicine ligands, were investigated for La(III), Nd(III), Tb(III), Th(IV) and U(VI). Trace amounts of these metal ions were quantitatively retained on the resin and recovered by eluting with 1 M hydrochloric acid. The capacity of the resin for La(III), Nd(III), Tb(III), Th(IV) and U(VI) was found to be 0.35, 0.40, 0.42, 0.25 and 0.38 mmol g(-1), respectively. Separation of U(VI) and Th(IV) from Ni(II), Zn(II), Co(II) and Cu(II) in a synthetic solution was carried out.  相似文献   

13.
A preconcentration procedure, using a short column loaded with Amberlite XAD-7, is proposed for the spectrophotometric determination of traces of tungsten. The procedure is based on the retention of tungsten on the resin after its reduction to a W(V)-thiocyanate complex with tin(II) chloride solution. Interference effects have been shown to be neglible for foreign ions including Ca2+, Mg2+, Na+, SO4 2–, F, NO3 , Cu2+, Fe3+ and Mo6+. The procedure has been applied to hot spring water with satisfactory results (Recovery > 95%; relative standard deviation < 5%; relative error < 3%).  相似文献   

14.
Uranium(VI) reacts withN-phenylcinnamohydroxamic acid to form an orange-yellow complex in the pH range 5.5–8.5. The orange-yellow complex, having the composition of 12 (metal:ligand), is quantitatively extractable into ethyl acetate. The spectrum of the complex exhibits a maximum absorption at 400 nm with a molar absorptivity of 6500 M–1·cm–1. The coloured system obeys Beer's law in the concentration range 2–40g·ml–1 of uranium(VI). The photometric sensitivity of the colour reaction is 0.037 g·cm–2 of uranium(VI). Most of the common ions do not interfere and the method has been found to be simple, precise, and free from the rigid control of experimental conditions. The method has been applied to the determination of uranium in synthetic matrices and potable water.  相似文献   

15.
16.
Summary Microgram quantities of uranium(VI) can be determined at 655 nm after separation by chloroform extraction of its Arsenazo III complex with Zephiramine. The extracted uranium can be back-extracted with an aqueous solution of ammonium carbonate. Uranium can be separated from aluminium, iron(II), and some other elements. Probably the same species, i. e., the ion association compound between the uranium (VI)-Arsenazo III complex and Zephiramine are involved during the extraction and the froth flotation.
Zusammenfassung Mikrogrammengen Uran(VI) lassen sich nach Chloroformextraktion seines Arsenazo-III-Komplexes mit Zephiramin bei 655 nm messen. Das extrahierte Uran kann man mit wäßriger Ammoniumcarbonatlösung rück-extrahieren. Von Aluminium, Eisen(II) und einigen anderen Elementen kann es so getrennt werden. Wahrscheinlich handelt es sich bei der Extraktion und der Schaumflotation um die gleiche Ionenassoziatverbindung des Uran (VI)-Arsenazo-III-Komplexes mit Zephiramin.


Presented at the 24th Annual Meeting of the Japan Society for Analytical Chemistry, Sapporo, October, 1975.  相似文献   

17.
Pyridine-2-carboxaldehyde 2-hydroxybenzoylhydrazone (PAHB) is proposed as an extractant for the separation and spectrophotometric determination of uranium(VI). The optimum extraction conditions have been evaluated by studying various parameters such as pH, diluents, equilibration time and reagent concentration. PAHB forms yellow colored complex with uranium(VI) in the pH range of 3.5-4.6 which can be extracted by isobutyl methyl ketone. The extracted complex exhibits an absorption maximum at 375 nm. Beer's law was obeyed in the concentration range 1.0-5.6 ppm of uranium(VI). The nature of the extracted species (1:2) was determined by log D-log c plot. The proposed method permits selective separation of uranium(VI) from its binary mixtures. The method is also applied for the estimation of uranium in multicomponent mixtures and monazite sand.  相似文献   

18.
Shigetomi Y  Kojima T  Kamba H 《Talanta》1980,27(12):1079-1080
Uranium(VI) is separated by extraction from nitric acid medium into a molten mixture of tri-n-octylphosphine oxide and benzophenone at about 50°. The organic phase solidifies on cooling and is separated and dissolved in ethanol. The uranium(VI) in this solution is then determined spectrophotometrically with 1-(2-pyridylazo)-2-naphthol.  相似文献   

19.
A method for detecting and quantifying uranium(VI) levels on building materials that include concrete, Plexiglas, glass and steel surfaces is presented. Uranium(VI) was extracted from building material surfaces using a pH 2.2 buffer rinse and, subsequently complexed by an organic chelating agent, arsenazo III. The application of a uranium-chelating molecule, arsenazo III, allows for concentration enhancement using C18 solid phase extraction and colorimetric detection of the uranium complex using ultraviolet-visible spectroscopy at 654 nm. The method has a detection limit (based on 3σ) of 40 ng/L (5 ng/cm2) and an overall extraction efficiency greater than 80% for each surface type (concrete, Plexiglas, glass, steel). Methods to prevent interference by metal ions commonly found on building materials are discussed.  相似文献   

20.
A very sensitive, selective and simple flow injection time-based method was developed for on-line preconcentration and determination of thorium(IV) at micro g L–1 levels in environmental samples. The system operation was based on thorium(IV) ion retention at pH 4.0 in the minicolumn at a flow rate of 15.2 mL min–1. The trapped complex was then eluted with 3.6 mol L–1 HCl at a flow rate of 4.9 mL min–1. The amount of thorium(IV) in the eluate was measured spectrophotometrically at 651 nm using arsenazo-III solution (0.05 % in 3.6 mol L–1 HCl stabilized with 1 % triton X-100, 4.9 mL min–1) as colorimetric reagent. All chemical, and flow injection variables were optimized for the quantitative preconcentration of metal and a study of interference level of various ions was also carried out. The system offered low backpressure and improved sensitivity and selectivity. At a preconcentration time of 60 s and a sample frequency of 40 h–1, the enhancement factor was 97, the detection limit was 0.25 μg L–1, and the precision expressed as relative standard deviation was 1.08 % (at 50 μg L–1), whereas for 300 s of the preconcentration time and a sample frequency of 10 h–1, the enhancement factor of 357, the detection limit (3σ) of 0.069 μg L–1 and the precision of 1.32 % (at 10 μg L–1) was reported. The accuracy of the developed method was sufficient and evaluated by the analysis of certified reference material IAEA-SL-1 (Lake Sediment) and spiked water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号