首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We are making a numerical comparison of various preprocessing strategies for dealing with data from voltammetric electronic tongues in order to reduce the high dimensionality of the response matrices. Different modelling tools are presented and briefly described. We then compare combinations of four preprocessing strategies (principal component analysis, fast Fourier transform, discrete wavelet transform, voltammogram-windowed slicing integral) with four modelling alternatives (principal component regression, partial least squares regression, multi-way partial least squares regression, artificial neural networks) by employing data from a voltammetric bioelectronic tongue, an array formed by enzyme-modified biosensors and applied to the discrimination and quantification of phenolic compounds.
Figure
We are making a numerical comparison of various preprocessing strategies for dealing with data from voltammetric electronic tongues in order to reduce the high dimensionality of the response matrices  相似文献   

2.
We report on a carbon ionic liquid electrode modified with a composite made from Nafion, graphene oxide and ionic liquid, and its application to the sensitive determination of rutin. The modified electrode was characterized by cyclic voltammetry and electrochemical impedance spectroscopy. It shows excellent cyclic voltammetric and differential pulse voltammetric performance due to the presence of nanoscale graphene oxide and the ionic liquid, and their interaction. A pair of well-defined redox peaks of rutin appears at pH 3.0, and the reduction peak current is linearly related to its concentration in the range from 0.08 μM to 0.1 mM with a detection limit of 0.016 μM (at 3σ). The modified electrode displays excellent selectivity and good stability, and was successfully applied to the determination of rutin in tablets with good recovery.
Figure
A Nafion, graphene oxide and ionic liquid 1-ethyl-3-methylimidazolium tetrafluoroborate composite was modified on carbon ionic liquid electrode (CILE) for the sensitive detection of rutin.  相似文献   

3.
We report on the voltammetric determination of the flavonoid Baicalein by using a carbon paste electrode that was doped with multi-walled carbon nanotubes. The resulting sensor exhibits excellent redox activity towards Baicalein due to the large surface area and good conductivity of the electrode. Cyclic voltammetry at various scan rates was used to investigate the redox properties of Baicalein. At the optimum conditions, the sensor displays a linear current response to Baicalein in the 0.02–10 μM concentration range, with a limit of detection of 4.2 n M. The method was successfully applied to the determination of Baicalein in spiked human blood serum samples and in a Chinese oral liquid.
Figure
We construct a new voltammetric sensor, based on multi-walled carbon nanotubes (MWCNT) doped Carbon paste electrode(CPE), The proposed electrode can improve the oxidation of Baicalein intensively, which can applied to the quantitative determination of Baicalein with wide linear response and low detection limit.  相似文献   

4.
We describe a new method for differential-pulse anodic stripping voltammetric determination of thallium(I) using a carbon paste electrode modified with dicyclohexyl-18-crown-6. The effect of supporting electrolyte (type and pH), accumulation and reduction potential, and of time and amount of modifier were investigated by differential pulse anodic stripping voltammetry. A method was then worked out for the determination of thallium at low levels. Under optimized conditions, the response to Tl(I) is linear in the range from 3.0 to 250 ng mL?1. The detection limit is 0.86 ng mL?1. The sensor displays good repeatability (with a relative standard deviation of ±2.70 % for n?=?7) and was applied to the determination of Tl(I) in water, hair samples, and certified reference materials.
Figure
Crown ethers allow only some ions to entry and complex formation that their sizes equal to ether cavity.  相似文献   

5.
A carbon paste electrode (CPE) was modified with multi-wall carbon nanotubes and successfully applied to the determination of silver ion by differential pulse anodic stripping voltammetry. Compared to a conventional CPE, a remarkably improved peak current response and sensitivity is observed. The analytical procedure consisted of an open circuit accumulation step for 2?min in ?0.4?V, this followed by an anodic potential scan between +0.2 and?+?0.6?V to obtain the voltammetric peak. The oxidation peak current is proportional to the concentration of silver ion in the range from 1.0?×?10?8 to 1.0?×?10?5?mol?L?1, with a detection limit of 1.8?×?10?9?mol?L?1 after an accumulation time of 120?s. The relative standard deviation for 7 successive determinations of Ag(I) at 0.1???M concentration is 1.99%. The procedure was validated by determining Ag(I) in natural waters.
Figure
Differential pulse voltammogram (DPV) of Ag+ solution at MCPE  相似文献   

6.
Voltammetry of microparticles is applied to characterise and to identify solid analytes of interest in the field of cultural heritage. Nafion® is used for the immobilisation of solid microparticles onto the surface of a glassy carbon electrode by exploiting the deposition onto the electrode surface of a micro-volume of a suspension of the microsample in polymeric solution. Cyclic voltammetry and square wave voltammetry are applied to characterise and to identify the microparticles immobilised in the Nafion® coating. The analyte studied in this work is Prussian Blue as a typical inorganic pigment, with a relatively simple electrochemical behaviour. The proposed method is applied to a sample of Venetian marmorino plaster. The performance of Nafion® for this analysis is compared with that of the polymer Paraloid B72.
Figure
From sampling the pigment in the work of art to recording the voltammetric signal with Nafion coated electrodes  相似文献   

7.
We report on a novel sensor for the electrochemical determination of thiourea (TU). It is based on an active carbon paste electrode modified with copper oxide nanoparticles. The modified electrode and the electrochemical properties of thiourea on its surface were investigated using cyclic voltammetry and differential pulse voltammetry. Under optimized conditions, the detection limit is 20 μg?L?1 of TU. The method was applied to the determination of thiourea in fruit juice, orange peel and industrial waste water.
Figure
Cyclic voltammograms of ACPE (A), CuO/ACPE (B) and CuO/CPE (C) in pH 8 phosphate buffered saline.  相似文献   

8.
We report on a voltammetric sensor for bisphenol A (BPA) that is based on an acetylene-black paste electrode modified with a chitosan film molecularly imprinted for BPA. The sensor responds linearly to BPA in the 80 nM to 10 μM concentration range, and the detection limit is 60 nM (at an S/N of 3). The use of a molecular imprint provides an efficient way for eliminating interferences from potentially interfering substances. The high sensitivity, selectivity and stability of the sensor demonstrate its practical application for the determination of BPA in plastic samples.
Figure
An acetylene black paste electrode modified with molecularly imprinted chitosan film was used as a novel voltammetric sensor for bisphenol A determination. The experimental results demonstrated that the combination of acetylene black with molecularly imprinted technique offered an attractive route to enhance the sensitivity and selectivity of the sensor.  相似文献   

9.
We report on the determination of choline and acetylcholine via biocentrivoltammetry. This method combines centrifugation and voltammetry and is based on a carbon paste electrode modified with acetylcholinesterase and choline oxidase. The electrode was placed at the bottom of a biocentrivoltammetric cell. Acetylcholine and choline are accumulated on the enzyme electrode via centrifugative forces, upon which a direct voltammetric scan is applied. Reaction time, pH values, quantities of enzyme and centrifugation parameters were optimized. A linear response is obtained in the 0.07 to 10?μM concentration range of acetylcholine, and a limit of detection as low as 0.5?μM. The linear range is between 0.1 and 500?μM for choline. The method was applied to the determination of acetylcholine and choline in spiked serum samples.
Figure
This work constitutes the first application of biocentri-voltammetry for ACh detection. Biocentri-voltammetry is the method where centrifuge and voltammetry is combined in a specially designed working cell. As a result, sensitive and effective biosensor was obtained.  相似文献   

10.
An immunosensor for determination of salbutamol was developed. It based on glass carbon electrode (GCE) modified with a conductive multilayer film comprised of multi-wall carbon nanotubes, polythionine and gold nanoparticles. Salbutamol antibody was immobilized on the surface of the modified GCE which then was blocked with bovine serum albumin (BSA). The stepwise self-assembly process of the immunosensor was studied by cyclic voltammetry. The detection scheme is based on competitive binding of salbutamol to the sensor surface whose differential pulse voltammetric signal decreases after competitive binding of the salbutamol-BSA conjugate and free salbutamol to the salbutamol antibody. The sensor responds to salbutamol in 5 to 150 nM concentration range, with a detection limit of 1 nM. This method was applied to the precise and sensitive determination of salbutamol in spiked feed samples.
Figure
In this work, we constructed a salbutamol immunosensor which was based on salbutamol-Ab adsorbed on the AuNPs/PTH/MWCNTs/GCE. Just as the procedures shown in Graph 1, competitive immunoreaction was the experimental principle. The percentage of current response of the immunosensor was proportional to salbutamol concentrations in the range of 5–150 nM.  相似文献   

11.
We report on the modification of a glassy carbon electrode with a composite consisting of silver nanoparticles (AgNPs), polydopamine, and graphene to give an electrochemical sensor for catechol. The composite was characterized by transmission electron microscopy, and the electrochemical behavior of catechol at the modified electrode was studied by cyclic voltammetry. The electrochemical response is greatly enhanced and thought to result from a combination of beneficial effects including the good conductivity and large surface area of the AgNPs, the high conductivity of graphene, the synergistic effects of the composite, and the increased quantity of catechol that is adsorbed on the surface of the electrode. Differential pulse voltammetric responses are proportional to the concentration of catechol between 0.5 and 240?μM levels of catechol, and the detection limit is 0.1?μM (S/N?=?3). The performance of the sensor was evaluated with catechol-spiked water samples, and recoveries range from 96.5 % to 103.1 %. The results indicated that the composite presented here is a promising substrate for use in electrochemical sensing.
Graphical abstract
We report on the modification of a glassy carbon electrode with a composite consisting of silver nanoparticles, polydopamine, and graphene to obtain an electrochemical sensor for catechol.  相似文献   

12.
We describe a silver(I)-selective carbon paste electrode modified with multi-walled carbon nanotubes and a silver-chelating Schiff base, and its electrochemical response to Ag(I). Effects of reduction potential and time, accumulation time, pH of the solution and the stripping medium were studied by differential pulse anodic stripping voltammetry and optimized. The findings resulted in a method for the determination of silver over a linear response range (from 0.5 to 235 ng?mL?1) and with a detection limit as low as 0.08 ng?mL?1. The sensor displays good repeatability (with the RSD of ±?2.75 % for 7 replicates) and was applied to the determination of Ag(I) in water samples and X-ray photographic films.
Figure
Open circuit accumulation of Ag(I) onto a surface of EHPO-MCPE and determination by Differential pulse anodic stripping voltammetry  相似文献   

13.
We have prepared a new voltammetric sensor for guanine and adenine. It is based on a glassy carbon electrode modified with a Langmuir-Blodgett film made from tetraoxocalix[2]arene[2]triazine. The direct electro-oxidation of adenine and guanine was investigated and the results indicat that in contrast to a bare glassy carbon electrode both guanine and adenine cause an increase in the oxidation peak currents along with a negative shift of the oxidation potentials. The electrode enables the simultaneous determination of guanine and adenine using square wave voltammetry. Analysis of acid denatured calf thymus DNA was carried out and the value of (G + C)/(A + T) was correctly found to be 0.75.
Figure
Both guanine and adenine showed the increase of the oxidation peak currents on LBTOCT-GCE in contrast to that on the bare glassy carbon electrode (GCE).  相似文献   

14.
We report on a sensor for epinephrine (EP) that is based on an ITO electrode modified with multi-walled carbon nanotubes pre-coated with a polymerized ionic liquid (PIL-MWNTs). A chitosan film was then electrodeposited on the ITO electrode in the presence of EP (the template) and the PIL-MWNTs. This film acts as an excellent recognition matrix due to its excellent film-forming ability and the many functional groups that favor hydrogen bond formation with the target (EP). The PIL-MWNTs, in turn, can improve the sensing performance due to their good electrical conductivity, high dispersity, and large surface area. The imprinted films were characterized by scanning electron microscopy, X-ray diffraction, Fourier transform IR spectroscopy, and thermogravimetric analysis. The electrochemistry of the imprinted electrode was investigated by cyclic voltammetry, electrochemical impedance spectroscopy, differential pulse voltammetry and chronoamperometry. The response to EP is linear in the 0.2 μM to 0.67 mM concentration range, and the detection limit is as low as 60 nM (at an S/N of 3). The electrode is reusable and offers good reproducibility and stability.
Figure
An epinephrine imprinted electrode was facile achieved by electrodepositing chitosan on ITO surface in the presence of epinephrine and polymerized ionic liquid-functionalized carbon nanotubes, followed by removal of the epinephrine template molecule. Specific recognition of EP molecule and its determination were realized at this imprinted sensor.  相似文献   

15.
We report on the modification of a graphene paste electrode with gold nanoparticles (AuNPs) and a Nafion-L-cysteine composite film, and how this electrode can serve as a platform for the construction of a novel electrochemical immunosensor for the detection of hepatitis B surface antigen (HBsAg). To obtain the immunosensor, an antibody against HBsAg was immobilized on the surface of the electrode, and this process was followed by cyclic voltammetry and electrochemical impedance spectroscopy. The peak currents of a hexacyanoferrate redox system decreased on formation of the antibody-antigen complex on the surface of the electrode. Then increased electrochemical response is thought to result from a combination of beneficial effects including the biocompatibility and large surface area of the AuNPs, the high conductivity of the graphene paste electrode, the synergistic effects of composite film, and the increased quantity of HBsAb adsorbed on the electrode surface. The differential pulse voltammetric responses of the hexacyanoferrate redox pair are proportional to the concentration of HBsAg in the range from 0.5–800?ng?mL?1, and the detection limit is 0.1?ng?mL?1 (at an S/N of 3). The immunosensor is sensitive and stable.
Figure
We report on the modification of a graphene paste electrode with gold nanoparticles and a Nafion-L-cysteine composite film, and how this electrode can serve as a platform for the construction of a novel electrochemical immunosensor for the detection of hepatitis B surface antigen. The immunosensor is sensitive and stable.  相似文献   

16.
Single-walled bismuth nanotubes (sw-BiNTs) were self-assembled with octa(3-aminopropyl) silsesquioxane as a framework and to govern morphology. Deposited on a glassy carbon electrode (GCE), the sw-BiNTs were used for the simultaneous analysis of Pb(II) and Cd(II) by square wave stripping voltammetry. The sw-BiNTs were prepared by (a) coordination interaction between the amino groups of the silsesquioxane and the Bi(III) ions, and by (b) reduction with sodium borohydride. Transmission electron microscopy images revealed single-walled tubular structures with diameters of ~4–6 nm, and with lengths of several hundreds nanometers. GCEs modified with such sw-BiNTs perform much better than bare GCEs in stripping analysis of Pb(II) and Cd(II). The effects of adsorption quantity of sw-BiNTs, solution pH, pulse amplitude, and pulse width were optimized. The modified electrode was then used for the analysis of Pb(II) and Cd(II) in a linear response range from 0.4 to 6 μM with a sensitivity of 4.692 μA μM?1 and 3.835 μA μM?1, and detection limits of 1 nM and 5 nM, respectively. The method was successfully applied to the analysis of Pb(II) and Cd(II) in toy leachates, and the results were in good agreement with those obtained with atomic absorption spectrometry. Sensitivity and detection limits were compared with other voltammetric methods, and the sw-BiNTs are deemed to be an attractive alternative for practical applications. Other features of the electrode include low costs, a well reproducible nanostructure, and ease of scale-up of the fabrication process.
Figure
Single-walled bismuth nanotubes (BiNTs) were self-assemblied with octa(3-aminopropyl) silsesquioxane as framework and morphology control agent for the simultaneous detection of trace Pb(II) and Cd(II) by square wave stripping voltammetry. The proposal preparation avoids time-consuming pre-treatment and experienced operation. The sensitivity and detection limit of the method was comparable to reported voltammetric methods, and BiNTs might be an alternative candidate for practical applications of electrochemical detection.  相似文献   

17.
Deoxyribonucleic acid (DNA) was electrochemically deposited on a carbon ionic liquid electrode to give a biosensor with excellent redox activity towards paraquat as shown by cyclic voltammetry and differential pulse voltammetry. Experimental conditions were optimized with respect to sensing paraquat by varying the electrochemical parameters, solution pH, and accumulation time of DNA. Under the optimized conditions, a linear relation exists between the reduction peak current and the concentration of paraquat in the range from 5?×?10?8 mol L?1 to 7?×?10?5 mol L?1, with a detection limit of 3.6?×?10?9 mol L?1. The utility of the method is illustrated by successful analysis of paraquat in spiked real water samples.
Figure
The DNA was electrodeposited onto the CILE under +1.5?V for 1200?s. The electrochemical behaviors of paraquat on the modified electrode had been studied by cyclic voltammetry and differential pulse voltammetry. Five ml phosphate buffer (pH 7.0) solution was added into an electrochemical cell (10?ml) and then paraquat was successfully added into the cell. The differential pulse voltammograms were recorded when swept from ?0.8?V to ?0.3?V. The peak currents at about ?0.63?V for paraquat were measured.  相似文献   

18.
A glassy carbon electrode (GCE) was modified with silicon carbide nanoparticles and used to investigate the electrochemistry of the drug nimesulide via voltammetry and chronoamperometry. The structure of the modified electrode was studied by field emission scanning electron microscopy. Nimesulide undergoes electroreduction at pH 2 at a potential that is shifted from ?526 mV (at the bare GCE) to ?387 mV at the modified electrode. Simultaneously, sensitivity is increased by a factor of 5.8. The charge transfer coefficient, diffusion coefficient, standard heterogeneous rate constant and catalytic reaction rate constant were determined. A plot potential vs. pH revealed a voltammetric pKa value of about 6.5–7.0. The differential pulse voltammetric calibration plot for nimesulide is linear in 0.09–8.7 μM concentration range, and the detection limit and sensitivity are 30 nM and 512 nA.μM?1, respectively. The modified electrode was applied to the determination of nimesulide in acidic solution and human blood serum samples without further pretreatment. The recoveries, as determined by the standard addition method, range from 95.7 to 98.7%, with an RSD of around 1.6%.
Figure
(A) CVs of SiC-NPs/GC modified electrode at scan rate 0.1 V.s-1 in pH 2.0 PBS solutions in the absence (c) and the presence of 8.0 μM nimesulide (d). (a) and (b) as (c) and (d), respectively at bare GC electrode. (B) DPVs at voltage step 0.008 V, sweep rate 0.02 V.s?1 and pulse amplitude 0.05 V in pH 2.0 PBS solutions in the absence (c) and the presence of 8.0 μM nimesulide (d). (a) and (b) as (c) and (d) respectively at bare GC electrode.  相似文献   

19.
We report on an anodic stripping voltammetric method for the determination of tin using a glassy carbon electrode modified with bismuth and poly(bromophenol blue). After an accumulation time of 60?s at ?1.20?V (vs. SCE), the response of the electrode to tin in 1.0?M HCl is linear in the concentration ranges from 20 nM to 1.0?μM, and from 1.0?μM to 20?μM, with a detection limit of 7.0 nM (at an SNR of 3) and with relative standard deviations in the order of 3.0–3.8%. The method was validated by comparing the results with those obtained by AAS and successfully applied to the determination of tin in canned food.
Figure
Differential pulse stripping voltammetric responses of Sn2+ at Bi/Poly(BPB)/GCE in 1.0 M HCl . Sn2+ concentration (μM): 0.020, 0.10, 0.30, 0.50, 0.70, 1.0, 3.0, 5.0, 7.0, 10.0 and 20.0. Inset: Differential pulse stripping voltammograms of circle portion at low Sn2+ concentration are zoomed in.  相似文献   

20.
We describe the fabrication of a sensitive label-free electrochemical biosensor for the determination of sequence-specific target DNA. It is based on a glassy carbon electrode (GCE) modified with graphene, gold nanoparticles (Au-NPs), and polythionine (pThion). Thionine was firstly electropolymerized on the surface of the GCE that was modified with graphene by cyclic voltammetry. The Au-NPs were subsequently deposited on the surface of the pThion/graphene composite film by adsorption. Scanning electron microscopy and electrochemical methods were used to investigate the assembly process. Differential pulse voltammetry was employed to monitor the hybridization of DNA by measuring the changes in the peak current of pThion. Under optimal conditions, the decline of the peak current is linearly related to the logarithm of the concentration of the target DNA in the range from 0.1 pM to 10 nM, with a detection limit of 35 fM (at an S/N of 3). The biosensor exhibits good selectivity, acceptable stability and reproducibility.
Figure
A label-free DNA biosensor based on Au-NPs/pThion/graphene modified electrode has been fabricated. Differential pulse voltammetry (DPV) was employed to monitor DNA hybridization event by measurement of the peak current changes of pThion.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号