首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We describe a simple, environmentally friendly and selective technique for the determination of ochratoxin A (OTA) in urine. It involves (a) the use of a molecularly imprinted polymer as a sorbent in micro-solid-phase extraction in which the sorbent is contained in a propylene membrane envelope, and (b) separation and detection by capillary electrophoresis (CE). Under optimized conditions, response is linear in the range between 50 and 300 ng mL?1 (with a correlation coefficient of 0.9989), relative standard deviations range from 4 to 8 %, the detection limit for OTA in urine is 11.2 ng mL?1 (with a quantification limits of 32.5 ng mL?1) which is lower than those of previously reported methods for solid-phase extraction combined with CE. The recoveries of OTA from urine spiked at levels of 50, 150 and 300 ng mL?1 ranged from 93 to 97 %.
Figure
?  相似文献   

2.
We report on the determination of bisphenol A and 2-naphthol in water samples using ionic liquid cold-induced aggregation dispersive liquid-liquid microextraction combined with HPLC. Parameters governing the extraction efficiency (disperser solvent, volume of extraction and disperser solvent, pH, temperature, extraction time) were optimized and resulted in enrichment factors of 112 for bisphenol A and of 186 for 2-naphthol. The calibration curve was linear with correlation coefficients of 0.9995 and 0.9998, respectively, in the concentration range from 1.5 to 200?ng?mL?1. The relative standard deviations are 2.3% and 4.1% (for n?=?5), the limits of detection are 0.58 and 0.86?ng?mL?1, and relative recoveries in tap, lake and river water samples range between 100.1 and 108.1%, 99.4 and 106.2%, and 97.1 and 103.8%, respectively.
Figure
IL-CIA-DLLME has a high enrichment factor (112, 186), acceptable relative recovery (97.1%?C108.1%), good repeatability (2.3%, 4.1%) and a wide linear range(1.5?C200?ng?mL?1 ) for the determination of bisphenol A and 2-naphthol.  相似文献   

3.
We report on a method for selective extraction and backextraction for the ultra-sensitive determination of Pd(II). Magnetite nanoparticles modified with sodium dodecyl sulfate were used to extract Pd(II) as its green 1-(2-pyridylazo)-2-naphtholate complex prior to zero- and first-derivative spectrophotometric determination at 659 and 681?nm, respectively. A sample volume of 70?mL was backextracted with 0.50?mL of n-butanol in a 3-phasic system. The effects of reaction time and the other variables were optimized. The enrichment factor is 134 and the calibration plots are linear in the range from 2 to 90?ng?mL-1 of Pd(II). The detection limit is 0.3?ng?mL-1 and the relative standard deviations and recoveries at levels of 10 and 72?ng?mL-1 of Pd(II) are in the range from 1.1?C4.9%, and from 98.5?C102.6%, respectively. Most ions do not significantly interfere. The method was successfully applied to the determination of Pd(II) in water and urine samples, alloys, and palladium catalysts.
Figure
The new SPE method was developed for the preconcentration-spectrophotometric determination of palladium using dodecyl sulfate coated magnetite nanoparticles as adsorbrnt and then backextraction by a low volume of n-butanol in a novel 3-phasic backextraction. The established SPE method proved to be efficient for palladium determination and provided satisfactory recoveries and precisions.  相似文献   

4.
We describe a nanometer sized composite material made from titanium dioxide and silica that was chemically modified with 4-aminophenylarsonic acid and used for selective solid-phase extraction, separation and preconcentration of of aluminum(III) prior to its determination by ICP-OES. Under optimized conditions, the static adsorption capacity is 56.58?mg?g?1, the enrichment factor is 150, the relative standard deviation is 1.6% (for n?=?11), and the detection limit (3?s) is 60?pg?mL?1. The method was validated by analyzing the reference materials GBW 09101 (hair) and GBW 10024 (scallop) and successfully applied to the determination of trace Al(III) in spiked water samples and human urine, with recoveries ranging from 96% to 101%.
Figure
4-aminophenylarsonic acid modified nanometer TiO2/SiO2 composite material has been developed to separate and concentrate trace Al(III) from aqueous samples. Parameters that affect the sorption and elution efficiency were studied in column mode, and the new adsorbent presents high selectivity and adsorption capacity for the solid phase extraction of trace Al(III).  相似文献   

5.
We report on the use of hollow fiber liquid-liquid-liquid microextraction (HF-LLLME) followed by corona discharge ion mobility spectrometry for the determination of dextromethorphan and pseudoephedrine in urine and plasma samples. The effects of pH of the donor phase, stirring rate, ionic strength and extraction time on HF-LLLME were optimized. Under the optimized conditions, the linear range of the calibration curves for dextromethorphan in plasma and urine, respectively, are from 1.5 to 150 and from 1 to 100 ng mL?1. The ranges for pseudoephedrine, in turn, are from 30 to 300 and from 20 to 200 ng mL?1. Correlation coefficients are better than 0.9903. The limits of detection are 0.6 and 0.3 ng mL?1 for dextromethorphan, and 8.6 and 4.2 ng mL?1 for pseudoephedrine in plasma and urine samples, respectively. The relative standard deviations range from 6 to 8%.
Figure
Hollow fiber liquid–liquid–liquid microextraction (HF-LLLME) followed by corona discharge ion mobility spectrometry (CD-IMS) was used for the determination of dextromethorphan and pseudoephedrine in urine and plasma samples.  相似文献   

6.
A competitive microplate fluoroimmunoassay was developed for the determination of human serum albumin in urine. It is based on the use of biotinylated CdTe quantum dots (QDs) whose synthesis is optimised in terms of storage stability, purification, and signal-to-noise ratio. The bioconjugated QDs were characterised by gel chromatography and gel electrophoresis. Storage stability and quantum yield were investigated. The excitation/emission wavelengths are 360/620?nm. The immunoassay of human serum albumin in urine has a working range from 1.7 to 10?μg.mL?1, and the limit of detection is 1.0?μg.mL?1.
Figure
Preparation of biotinylated quantum dots is described. Their structure consists of biotinylated denatured bovine serum albumin attached to the quantum dot surface. Fluoroimmunoassay for human serum albumin was developed utilizing thus prepared bioconjugate.  相似文献   

7.
We report on a simple, sensitive and reliable method for the cloud point extraction of antimony (Sb) and its subsequent spectrophotometric detection. It is based on the color reaction of Sb (III) with iodide in acidic medium and subsequent micelle-mediated extraction of tetraiodoantimonate using a non-ionic surfactant in the absence of any chelating agent. The effects of reaction and extraction parameters were optimized. The calibration plot is linear in the range of 0.80–95?ng?mL?1 of antimony in the sample solution, with a regression coefficient (r) of 0.9994 (for n?=?9). The detection limit (at SNR?=?3) is 0.23?ng?mL?1, and the relative standard deviations at 10 and 70?ng?mL?1 of antimony are 3.32 and 1.85?% (at n?=?8), respectively. The method compared favorably to other methods and was applied to determine antimony in seawater, anti-leishmania drug (glucantime), and human serum.
Figure
This method is based on the extraction of yellow iodoantimonous acid (HSbI4) into surfactant-rich phase of Triton X-114 when trivalent antimony in sulfuric acid solution is treated with an excess of potassium iodide solution.  相似文献   

8.
We report on a new method for preconcentration of silver ion at trace level in environmental samples, and its subsequent determination by flame atomic absorption spectrometry (FAAS). The room temperature ionic liquid (RTIL) 1-butyl-3-methylimidazolium hexafuorophosphate and the chelator 5-(4-dimethylaminobenzylidene)-rhodanine were used for extraction. Ag(I) was back-extracted from the organic phase into thiosulfate solution and then determined via FAAS. The effects of pH, concentration of chelating agent, extraction time and temperature, amounts of ionic liquid, ionic strength and potentially interfering ions were studied. Under optimized conditions, the enhancement factor is 30 was achieved. The detection limit (3???) is 0.28?ng?mL?1, and the relative standard deviation is 4.1% for 7 replicate determinations at 5?ng?mL?1 of Ag(I). The method was validated by analysis of certified reference materials and applied to the determination of Ag(I) in environmental samples with satisfactory results.
Graphical abstract
Silver ions at trace level in environmental samples were chelated by 5-(4-dimethylaminobenzylidene)-rhodanine and preconcentrated by room temperature ionic liquid. After back-extraction, silver was determined by flame atomic absorption spectrometry sensitively.  相似文献   

9.
Dispersive liquid-liquid microextraction as a rapid, simple and efficient method coupled with high performance liquid chromatography-UV-Vis detection was used for sample preparation and subsequent determination of carbazole, tri nitro carbazole (TrNC) and tetra nitro carbazole in water samples. The influence of several important variables on the extraction efficiency has been evaluated. The methods works best with chloroform as an extractant and acetonitrile as the dispersive solvent. Under optimum conditions, the calibration curve is linear in the range from 0.007 to 1.75?μg?mL?1 for TNC, 0.006 to 1.52?μg?mL?1 for TrNC, and 0.008–2.10?μg?mL?1 for carbazole. The limits of detection (LODs; at a signal-to-noise ratio of 3), range from 1.7 to 1.1?ng?mL?1, for TNC, TrNC and carbazole. Also, the relative standard deviations (RSD, n?=?6) for the extraction of TNC (at 174?ng?mL?1), TrNC (at 151?ng?mL?1) and carbazole (at 84?ng?mL?1) vary between 4.1 and 5.2%. The enrichment factors range from 179 to 186. The method was successfully applied to the determination of TNC, TrNC and carbazole in environmental samples.
Figure
Dispersive liquid-liquid microextraction is presented for the determination of carbazole based explosives (tri nitro carbazole (TrTNC) and tetra nitro carbazole (TNC)) using high performance liquid chromatography and UV–vis detection.  相似文献   

10.
Glassy carbon electrodes (GCE) and carbon paste electrodes (CPE) were modified with imidazole functionalized polyaniline with the aim to develop a sensor for lead (II) in both acidic and basic aqueous solution. The electrodes were characterized by cyclic voltammetry and differential pulse adsorptive stripping voltammetry. The limit of detections obtained with glassy carbon electrode and carbon paste electrode are 20?ng?mL-1 and 2?ng?mL-1 of lead ion, respectively. An interference study was carried out with Cd(II), As(III), Hg(II) and Co(II) ions. Cd(II) ions interfere significantly (peak overlap) and As(III) has a depressing effect on the lead signal. The influence of pH was investigated indicating that bare and modified GCE and CPE show optimum response at pH?4.0 ± 0.05.
Figure
Imidazole functionalized polyaniline modified glassy carbon and carbon paste electrodes were used for lead ion detection by using CV and DPASV techniques. The lower detection limit observed with GCE and CPE are 20?ng mL-1 and 2?ng mL-1.  相似文献   

11.
We have developed a technique for the solid-phase extraction of gold using various kinds of pyridine-functionalized nanoporous silica prior to its determination in various samples using FAAS. The effects of solution pH, sample and eluent flow rate, sample volume and of potentially interfering ions are compared. The limits of detections vary from 28 to 53?pg?mL?1. The accuracy and precision are between 99.8% and 98.3?% and 0.7 to 1.6?% (RSD), respectively. The method was successfully applied to several standard reference materials.
Figure
A technique has been developed for the solid-phase extraction of gold using various kinds of pyridine-functionalized nanoporous silica prior to its determination in various samples using FAAS.  相似文献   

12.
The anti-schizophrenic drug risperidone (RSP) exerts an inhibitory effect on the chemiluminescence (CL) of the luminol-lysozyme system. This finding forms the basis for a sensitive flow injection method for its determination at picogram levels. RSP binds to Trp62 in the lysozyme, and this leads to a conformational change upon which the CL of the system is quenched. The decrease in CL is proportional to the logarithm of the concentration of RSP, and the calibration graph is linear in the range from 0.1 pg?mL?1 to 1.0 ng?mL?1, with relative standard deviations of <5.0%, and a detection limit of 0.05 pg?mL?1 (3σ). At a flow rate of 2.0 mL?min?1, the whole process including sampling and washing is completed within 20 s. The method was successfully applied to monitoring RSP in human urine after incorporation of 2 mg of RSP, with a total excretion of 16.6% within 8.5 h.
Figure
The reaction of lysozyme with risperidone using luminol as luminescence reagent by the luminol-lysozyme FI-CL system and its application.  相似文献   

13.
We have surface-functionalized magnetic particles (MPs) with polydimethylsiloxane and multi-walled carbon nanotubes in a two-step reaction. The MPs were applied to solid-phase extraction of the fluoroquinolones ofloxacin, norfloxacin, ciprofloxacin, enrofloxacin prior to their determination by capillary liquid chromatography. The effects of sample pH, adsorption time, type of eluent, desorption time and desorption temperature were investigated. Under the optimum conditions, the extraction efficiencies are in the range from 81.5?% to 94.1?%, with relative standard deviations (RSDs) of <7.6?%. The detection limits vary from 0.24 to 0.48?ng?mL?1. The method was applied to the analysis of spiked mineral water and honey. The recoveries for the fluoroquinolones in the real samples range from 84.0?% to 112?%, with RSDs ranging from 2.9?% to 7.8?%.
Figure
?  相似文献   

14.
We have prepared a highly selective and efficient sorbent for the simultaneous separation and preconcentration of lead and cadmium ions from milk and water samples. An ionic liquid was deposited on the surface of magnetic nanoparticles (IL-MNPs) and used for solid phase extraction of these ions. The IL-MNPs carrying the target metals were then separated from the sample solution by applying an external magnetic field. Lead and cadmium were almost quantitatively retained by the IL-MNPs, and then eluted with nitric acid. The effect of different variables on solid phase extraction was investigated. The calibration curve is linear in the range from 0.3 to 20?ng mL?1 of Cd(II), and from 5 to 330?ng mL?1 of Pb(II) in the initial solution. Under optimum conditions, the detection limits are 1.61 and 0.122?μg?L-1 for Pb(II) and Cd(II) respectively. Relative standard deviations (n?=?10) were 2.87?% and 1.45?% for 0.05?μg?mL-1 and 0.2?μg?mL-1 of Cd (II) and Pb (II) respectively. The preconcentration factor is 200 for both of ions.
Figure
A novel, highly selective and efficient sorbent, was prepared and applied for separation and preconcentration of lead and cadmium from real samples. Lead and cadmium could be quantitatively retained by ionic liquid-modified magnetite nanoparticles and then easily separated from the aqueous solution by applying an external magnetic field; so, no filtration or centrifugation was necessary.  相似文献   

15.
We have developed a cloud point extraction procedure based on room temperature ionic liquid for the preconcentration and determination of mercury in water samples. Mercury ion was quantitatively extracted with tetraethyleneglycol-bis(3- methylimidazolium) diiodide in the form of its complex with 5,10,15,20-tetra-(4-phenoxyphenyl)porphyrin. The complex was back extracted from the room temperature ionic liquid phase into an aqueous media prior to its analysis by spectrofluorimetry. An overall preconcentration factor of 45 was accomplished upon preconcentration of a 20?mL sample. The limit of detection obtained under the optimal conditions is 0.08?μg mL?1, and the relative standard deviation for 10 replicate assays (at 0.5?g mL?1 of Hg) was 2.4%. The method was successfully applied to the determination of mercury in tap, river and mineral water samples.
Figure
In this work, a novel and sensitive analytical methodology for mercury preconcentration and determination in different water samples using ionic liquid was developed. The use of room temperature ionic liquid‘s biphasic systems as an alternative to conventional solvents offers several advantages including safety and high capacity to extract Hg(II) and other elements with high recoveries. ?onic liquid in combination with porphyrin complexing reagent was successfully applied in this study for the extraction and preconcentration of Hg(II). Likewise, a fast and quantitative back extraction of the analyte from room temperature ionic liquid phase into aqueous phase was possible, allowing its further determination by spectrofluorimetry. The preconcentration method allowed mercury determination in tap, river and mineral water samples at trace levels with high accuracy and reproducibility.  相似文献   

16.
An immunosensor was prepared for the determination of carcinoembryonic antigen (CEA). It is based on the use of multiwalled carbon nanotubes (MWCNTs) along with horseradish peroxidase-labeled antibody. The enzyme was assembled onto MWCNTs templates using the layer-by-layer technique and then conjugated to carcinoembryonic secondary antibodies (Ab2) as the enzyme label. The resulting assembly results in a largely amplified sensitivity. The response is linear in the range of 0.05 to 45?ng?mL-1, with a detection limit of 16.0?pg?mL-1. The immunosensor possesses good stability and good reproducibility.
Figure
A new immunosensor with double-layer enzyme-modified carbon nanotubes as label for sandwich-type tumor markers was proposed in this study  相似文献   

17.
We report on a simple, rapid, and efficient method for the extraction of volatile organic compounds (VOCs; including methanol, tetrahydrofuran, 2-hexanone and benzene) from air and solid samples. The system is based on the use of a laboratory-made syringe as the extractor. The needle of the syringe is placed in a chamber cooled by liquid nitrogen. The tip of the needle is placed in the headspace of a vial containing the sample. The headspace components then are circulated with a pump to pass the needle, and this results in freeze-trapping of the VOCs on the inner surface of the needle. The circulation of the headspace components is continued for 15 min, and the syringe is then removed and placed in a GC injector. The effects of volume of the sample vial, headspace flow rate, temperature and time of extraction and desorption were optimized. The overall time for sampling and analysis is <30 min. The method displays an extraction efficiency of >80%) and a good sample transfer efficiency into the GC column due to the absence of a sorbent inside the needle. No carry-over was observed after 30?s desorption at 260?°C. An external standard method was used for quantitative analysis. The relative standard deviation values are below 10% and the limits of detection range from 1.3 to 4.6?ng?g?1.
Fiugre
The scheme of sorbentless cryogenic needle trap device  相似文献   

18.
We have evaluated an in-situ ionic liquid-dispersive liquid-liquid microextraction procedure for the determination of six endocrine disrupting phenols in seawaters and industrial effluents using HPLC. The optimized method requires 38???L of the water-soluble ionic liquid 1-butyl-3-methylimidazolium chloride, and 5?mL of seawater or industrial effluent. After appropriate work-up, a drop (~10???L) of an ionic liquid is formed that contains the analytes of interest. It is diluted with acetonitrile and injected into the HPLC system. This procedure is accomplished without heating or cooling the solutions. The method is characterized by (a) average relative recoveries of 90.2%, (b) enrichment factors ranging from 140 to 989, and (c) precisions (expressed as relative standard deviations) of less than 11% when using a spiking level of 10?ng?mL?1. The limits of detection range from 0.8?ng?mL?1 for 4-cumylphenol to 4.8?ng?mL?1 for bisphenol-A.
Figure
Scheme of the in situ IL-DLIME procedure to determine endocrine disrupting phenols in environmental waters.  相似文献   

19.
We have developed a highly sensitive microextraction method for the preconcentration of some phthalate esters such as diethyl phthalate, di-n-propylphthalate, di-n-butyl-phthalate, dicyclohexyl-phthalate, and diethyl-hexyl phthalate prior to their determination by HPLC. It is based on a magnetic graphene nanocomposite as an effective adsorbent. The effects of the amount of the extractant composite employed, extraction time, pH values, salt concentration and desorption conditions were investigated. Under the optimum conditions, the enrichment factors range from 1574 to 2880. Response is linear in the concentration range from 0.1 to 50?ng?mL?1. The limits of detection (at S/N?=?3) were between 0.01 and 0.04?ng?mL?1. The method was successfully applied to the determination of five phthalate esters in water and beverage samples.
A novel microextraction method was developed by using magnetic graphene nanocomposite as an effective adsorbent for the preconcentration of some trace phthalate esters in water and beverage samples followed by high performance liquid chromatography with ultraviolet detection. The enrichment factors of the method for the compouds were achieved ranging from 1574 to 2880.  相似文献   

20.
We have extracted ten phthalate esters (C1 to C8) using six different micro-scale methods for extraction, and then separated them by capillary liquid chromatography coupled to UV detection. The methods included liquid-liquid extraction, ultrasonic-assisted extraction, microwave-assisted extraction, dispersive liquid-liquidmicroextraction, dispersive liquid-liquid microextraction solidification of floating organic droplets, and cloud point extraction. The linear range of the analytes is from 0.5 to 50 μg mL?1, and the detection limits range from 0.02 to ~0.17 μg mL?1. The precision and accuracy of all intra- and inter-day analyses are <5.5%. We find that dispersive liquid-liquid microextraction solidification of floating organic droplet (DLLME-SFO) is the best method for quantification of most phthalate esters in water samples and cosmetics because of its low limit of detection and high extraction efficiencies.
Figure
Phthalate esters were extracted by six micro-scale extraction methods and then determinated by capillary liquid chromatography coupled with ultraviolet detector (CapLC-UV).  相似文献   