首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A selective, precise, and accurate method was developed for the determination of cimetidine (C), famotidine (F), and ranitidine hydrochloride (R x HCl) in the presence of their sulfoxide derivatives. The method involves quantitative densitometric evaluation of mixtures of the drugs and their derivatives after separation by high-performance thin-layer chromatography on silica gel plates (10 x 20 cm) with ethyl acetate-isopropanol-20% ammonia (9 + 5 + 4, v/v) as the mobile phase for both C and F and ethyl acetate-methanol-20% ammonia (10 + 2 + 2, v/v) as the mobile phase for R x HCl; Rf values for C, F, and R x HCl and their corresponding derivatives were 0.85 and 0.59, 0.73 and 0.41, and 0.56 and 0.33, respectively. Developing time was approximately 20 min. For densitometric evaluation, peak areas were recorded at 218, 265, and 313 nm for C, F, and R x HCl, respectively. The relationship between concentration and the corresponding peak area was plotted for the ranges of 5-50 microg/spot for C and 2-20 microg/spot for F and R x HCl. Mean recoveries were 100.39 +/- 1.33, 99.77 +/- 1.30, and 100.09 +/- 0.69% for C, F, and R x HCl, respectively. The proposed method was used successfully for stability testing of the pure drugs in the presence of up to 90% of their degradates, in bulk powder and dosage forms. The results obtained were analyzed statistically and compared with those obtained by the official methods.  相似文献   

2.
This paper describes validated high-performance liquid chromatographic (LC) and high-performance thin-layer chromatographic (TLC) methods for the simultaneous estimation of olanzapine and fluoxetine in pure powder and tablet formulations. The LC separation was achieved on a Lichrospher 100 RP-180, C18 column (250 mm, 4.0 mm id, 5 microm) using 0.05 M potassium dihydrogen phosphate buffer (pH 5.6 adjusted with o-phosphoric acid)-acetonitrile (50 + 50, v/v) as the mobile phase at a flow rate of 1 mL/min and ambient temperature. The TLC separation was achieved on aluminum sheets coated with silica gel 60F254 using methanol-toluene (40 + 20, v/v) as the mobile phase. Quantitation was achieved by measuring ultraviolet absorption at 233 nm over the concentration range of 10-70 and 40-280 microg/mL with mean recovery of 99.54 +/- 0.89 and 99.73 +/- 0.58% for olanzapine and fluoxetine, respectively, by the LC method. Quantitation was achieved by measuring ultraviolet absorption at 233 nm over the concentration range of 100-800 and 400-3200 ng/spot with mean recovery of 101.53 +/- 0.06 and 101.45 +/- 0.35% for olanzapine and fluoxetine, respectively, by the TLC method with densitometry. These methods are simple, precise, and sensitive, and they are applicable for simultaneous determination of olanzapine and fluoxetine in tablet formulations.  相似文献   

3.
Reversed-phase liquid chromatography (LC) and LC/tandem mass spectrometry (LC/MS/MS) methods were developed and validated for the determination of etoricoxib in pharmaceutical dosage forms. The LC method was performed by reversed-phase chromatography on a Synergi fusion C18 column (150 x 4.6 mm id) maintained at ambient temperature. The mobile phase consisted of 0.01 M phosphoric acid, pH 3.0-acetonitrile (62 + 38, v/v) at a flow rate of 1.0 mL/min, and photodiode array detection at 234 nm was used. The chromatographic separation was obtained within 7.0 min, and calibration curves were linear in the concentration range of 0.02-150 microg/mL. The LC/MS/MS method was performed on a Luna C18 column (50 x 3.0 mm id). The mobile phase consisted of acetonitrile-water (95 + 5)-0.1% acetic acid (90 + 10, v/v). Detection was performed by positive electrospray ionization in the multiple reaction monitoring mode, monitoring the transitions 359.3 > 280.0 and 332.0 > 95.0 for etoricoxib and piroxicam (internal standard), respectively. The chromatographic separation was obtained within 2.0 min, and calibration curves were linear in the concentration range of 1-5000 ng/mL. Validation parameters, such as specificity, linearity, precision, accuracy, and robustness, were evaluated, which gave results within the acceptable range for both methods. Moreover, the proposed methods were successfully applied for routine quality control analysis of pharmaceutical products and showed significant correlation (r = 0.9999) of the results.  相似文献   

4.
Three stability indicating assay methods are developed for the determination of norfloxacin (Nor) in the presence of its decarboxylated degradation product and in mixture with tinidazole (Tnd). The proposed methods are reversed phase ion pair liquid chromatography (LC), thin layer densitometry (TLC) and second derivative ratio spectra zero crossing spectrophotometry ((2)DD). Chromatographic separation was achieved on mu-Bondapack C18 column 5 microm (300 mm x 3.9 mm, I.D.) and precoated silica gel TLC stationary phases for LC and TLC methods, respectively. Mobile phases consisting of phosphate buffer pH 3.2 : methanol (3 : 1, v/v) containing 0.005 M pentane sulfonic acid sodium salt and isopropanol : butanol : concentrated ammonia : water (25 : 50 : 5 : 25, v/v/v/v) were used for resolution of Nor and Tnd by both techniques, respectively. Detection was carried at 280 nm. In the ratio spectra method, detection of Nor was carried at 282 nm. Linearity, accuracy and precision were found to be acceptable over concentration ranges of 20-225 microg/ml, 0.8-4 microg/spot and 1-7 microg/ml for Nor by LC, TLC and (2)DD methods and over concentration ranges of 37.5-375 microg/ml and 4.8-20 microg/spot for Tnd by LC and TLC methods respectively. The suggested methods were successfully applied for the determination of both drugs in bulk powder, laboratory prepared mixtures and in commercial samples. Statistical comparison between the results obtained by the proposed and the reference methods was carried out using Student t-test, F ratio and one way ANOVA.  相似文献   

5.
Three stability-indicating assay methods were developed for the determination of tropisetron in a pharmaceutical dosage form in the presence of its degradation products. The proposed techniques are HPLC, TLC, and first-derivative spectrophotometry (1D). Acid degradation was carried out, and the degradation products were separated by TLC and identified by IR, NMR, and MS techniques. The HPLC method was based on determination of tropisetron in the presence of its acid-induced degradation product on an RP Nucleosil C18 column using methanol-water-acetonitrile-trimethylamine (65 + 20 + 15 + 0.2, v/v/v/v) mobile phase and UV detection at 285 nm. The TLC method was based on the separation of tropisetron and its acid-induced degradation products, followed by densitometric measurement of the intact spot at 285 nm. The separation was carried out on silica gel 60 F254 aluminum sheets using methanol-glacial acetic acid (22 + 3, v/v) mobile phase. The 1D method was based on the measurement of first-derivative amplitudes of tropisetron in H2O at the zero-crossing point of its acid-induced degradation product at 271.9 nm. Linearity, accuracy, and precision were found to be acceptable over concentration ranges of 40-240 microg/mL, 1-10 microg/spot, and 6-36 micro/mL for the HPLC, TLC, and 1D methods, respectively. The suggested methods were successfully applied for the determination of the drug in bulk powder, laboratory-prepared mixtures, and a commercial sample.  相似文献   

6.
Three reliable, rapid and selective methods have been developed and validated for the determination of lamotrigine in the presence of its impurity, 2,3-dichlorobenzoic acid. The first method is spectrophotometric method using p-chloranilic acid forming a colored product with lambda(max) 519+/-2 nm. All variables affecting the reaction have been investigated and the conditions were optimized. Beer's law was obeyed over a concentration range of 10-200 microg ml(-1) with mean accuracy 100.13+/-0.44%. The molar ratio of the formed ion-association complex is found to be 1 : 1 as deduced by Job's method. The conditional stability constant (K(f)), standard free energy (DeltaG), molar absorptivity(epsilon), and sensitivity index were evaluated. The second method is based on TLC separation of the cited drug (Rf=0.75+/-0.01) from its impurity (Rf=0.23+/-0.01) followed by densitometric measurement of the intact drug spots at 275 nm. The separation was carried on silica gel plates using ethyl acetate : methanol : ammonia 35% (17 : 2 : 1 v/v/v) as a mobile phase. The linearity range was 0.5-10 microg/spot with mean accuracy 99.99+/-1.33%. The third method is accurate and sensitive stability-indicating HPLC method based on separation of lamotrigine from its impurity on a reversed phase C(18) column, using a mobile phase of acetonitrile : methanol : 0.01 M potassium orthophosphate (pH 6.7+/-0.1) (30 : 20 : 50 v/v/v) at ambient temperature 25+/-5 degrees C and UV detection at 275 nm in an overall analysis time of about 6 min., based on peak area. The injection repeatability, intraday and interday repeatability were calculated. The procedure provided a linear response over the concentration range 1-12 microg ml(-1) with mean accuracy of 99.50+/-1.30%. The proposed methods were successfully applied for the determination of lamotrigine in bulk powder, in dosage form and in presence of its impurity. The results obtained were analyzed by ANOVA to assess that no significant difference between each of the three methods and the reported one. The validation was performed according to USP guidelines.  相似文献   

7.
A new RP-LC method and two new spectrophotometric methods, principal component regression (PCR) and first derivative spectrophotometry, are proposed for simultaneous determination of diflucortolone valerate (DIF) and isoconazole nitrate (ISO) in cream formulations. An isocratic system consisting of an ACE C18 column and a mobile phase composed of methanol-water (95 + 5, v/v) was used for the optimal chromatographic separation. In PCR, the concentration data matrix was prepared by using synthetic mixtures containing these drugs in methanol-water (3 + 1, v/v). The absorbance data matrix corresponding to the concentration data matrix was obtained by measuring the absorbances at 29 wavelengths in the range of 242-298 nm for DIF and ISO in the zero-order spectra of their combinations. In first derivative spectrophotometry, dA/dlambda values were measured at 247.8 nm for DIF and at 240.2 nm for ISO in first derivative spectra of the solution of DIF and ISO in methanol-water (3 + 1, v/v). The linear ranges were 4.00-48.0 microg/mL for DIF and 50.0-400 microg/mL for ISO in the LC method, and 2.40-40.0 microg/mL for DIF and 60.0-260 microg/mL for ISO in the PCR and first derivative spectrophotometric methods. These methods were validated by analyzing synthetic mixtures. These three methods were successfully applied to two pharmaceutical cream preparations.  相似文献   

8.
A new, specific, and sensitive RP-HPLC method was developed for the simultaneous determination of eprosartan (EPR) and hydrochlorothiazide (HCT). Good chromatographic separation was achieved using a 250 x 4.6 mm id, 5 microm particle size Symmetry C18 column. The mobile phase acetonitrile-0.1 M phosphate buffer (35+65, v/v), pH 4.5, was pumped at a flow rate of 1 mL/min, with UV detection at 275 nm. The method showed good linearity in the ranges of 0.5-50 and 0.1-10 microg/mL, with LOD of 0.06 and 0.02 microg/mL and LOQ of 0.20 and 0.08 microg/mL for EPR and HCT, respectively. The proposed method was successfully applied for the analysis of the studied drugs in their synthetic mixture and co-formulated tablets. The method was further extended to the in vitro and in vivo determination of the two drugs in spiked and real human plasma. Interference likely to be encountered from the co-administered drugs was studied.  相似文献   

9.
This paper describes validated high-performance column liquid chromatographic (HPLC) and high-performance thin-layer chromatographic (HPTLC) methods for simultaneous estimation of acetylsalicylic acid (ASA) and clopidogrel bisulfate (CLP) in pure powder and formulations. The HPLC separation was achieved on a Nucleosil C8 column (150 mm length x 4.6 mm id, 5 microm particle size) using acetonitrile-phosphate buffer, pH 3.0 (55 + 45, v/v) mobile phase at a flow rate of 1.0 mL/min at ambient temperature. The HPTLC separation was achieved on an aluminum-backed layer of silica gel 60F254 using ethyl acetate-methanol-toluene-glacial acetic acid (5.0 + 1.0 + 4.0 + 0.1, v/v/v/v) mobile phase. Quantitation was achieved with UV detection at 235 nm over the concentration range 4-24 microg/mL for both drugs, with mean recoveries of 99.98 +/- 0.28 and 100.16 +/- 0.66% for ASA and CLP, respectively, using the HPLC method. Quantitation was achieved with UV detection at 235 nm over the concentration range of 400-1400 ng/spot for both drugs, with mean recoveries of 99.93 +/- 0.55 and 100.21 +/- 0.83% for ASA and CLP, respectively, using the HPTLC method. These methods are simple, precise, and sensitive, and they are applicable for the simultaneous determination of ASA and CLP in pure powder and formulations.  相似文献   

10.
Three methods are presented for the simultaneous determination of diloxanide furoate (DLX) and metronidazole (MTR), used for their antiprotozoal and antiamoebic effect, in the presence of DLX alkaline degradates and in pharmaceutical formulations, without previous separation. The first method is chemometric-assisted spectrophotometry, in which principal component regression and partial least squares were applied. These two approaches were successfully applied to quantify each drug in the mixture using the information included in, the absorption spectra in the range of 225-320 nm. The second method is TLC-densitometry, in which the binary mixture and degradates were separated on silica gel plates using a chloroform-acetone-glacial acetic acid (9.5 + 0.5 + 0.07, v/v/v) mobile phase and the bands were scanned at 254 nm. The last method is HPLC, in which DLX, MTR, and degradates were separated using the mobile phase acetonitrile-0.05 M dibasic potassium phosphate (25 + 75, v/v), adjusted to pH 4 with orthophosphoric acid, at a flow rate of 1 mL/min, on a C18 analytical column. Detection was at 254 nm. The proposed methods were successfully applied for the analysis of DLX and MTR in pharmaceutical formulations, and the results were statistically compared with a reported spectrophotometric method.  相似文献   

11.
Two sensitive and selective methods were developed for the determination of some oxicams, namely, lornoxicam (LOX), tenoxicam (TEX), and meloxicam (MEX), in the presence of their alkaline degradation products. The first method is based on the thin-layer chromatographic separation of the 3 drugs from their alkaline degradation products, followed by densitometric measurement of the intact drug spots for LOX, TEX, and MEX at 380, 370, and 364 nm, respectively. The developing systems used for separation are ethyl acetate-methanol-26% ammonia (17 + 3 + 0.35, v/v/v) for LOX and TEX and chloroform-n-hexane-96.0% acetic acid (18 + 1 + 1, v/v/v) for MEX. The linear ranges were 0.25-6.0 microg/spot for LOX and TEX and 0.5-10 microg/spot for MEX, with mean recoveries of 99.80 +/- 1.32, 100.57 +/- 1.34, and 100.71 +/- 1.57%, respectively. The second method is based on the liquid chromatographic separation of the 3 drugs from their alkaline degradation products on a reversed-phase C18 column, using mobile phases of methanol-acetonitrile-acetate buffer, pH 4.6 (4.5 + 0.5 + 5.0, v/v/v) for LOX and MEX and methanol-acetonitrile-acetate buffer, pH 4.6 (1.9 + 0.1 + 3.0, v/v/v) for TEX at ambient temperature. Quantification is achieved by UV detection at 280 nm, based on peak area. The linear ranges were 0.5-20 microg/mL for LOX and TEX and 1.25-50 microg/mL for MEX, with mean recoveries of 99.81 +/- 1.01, 98.90 +/- 1.61, and 100.86 +/- 1.55%, respectively. The methods were validated according to guidelines of the International Conference on Harmonization. The developed methods were successfully applied to the determination of LOX, TEX, and MEX in bulk powder, laboratory-prepared mixtures containing different percentages of degradation products, and pharmaceutical dosage forms.  相似文献   

12.
Column high-performance liquid chromatographic (LC) and UV spectrophotometric methods for the quantitative determination of citalopram, a potent and selective serotonin reuptake inhibitor, in tablets were developed. The parameters linearity, precision, accuracy, specificity, robustness, limit of detection, and limit of quantitation were studied according to International Conference on Harmonization guidelines. Chromatography was carried out by the reversed-phase technique on an ACE C18 column with a mobile phase composed of 0.30% triethylamine solution-acetonitrile (55 + 45, v/v) adjusted to pH 6.6 with 10% ortho-phosphoric acid at a flow rate of 1.0 mL/min and 25 degrees C. The UV spectrophotometric method was performed at 239 nm. The linearity of the LC method was in the range of 10.00-70.00 microg/mL, and 2.50-17.50 microg/mL for the UV spectrophotometric method. The interday and intraday assay precision was < 1.5% (relative standard deviation) for the LC and UV spectrophotometric methods. The recoveries were in the range 100.70-101.35% for the LC method and 98.48-98.65% for the UV spectrophotometric method. Statistical analysis by Student's t-test showed no significant difference between the results obtained by the 2 methods. The proposed methods are highly sensitive, precise, and accurate and can be used for the reliable quantitation of citalopram in tablets.  相似文献   

13.
Simple, rapid, and selective RP-HPLC methods with UV detection were developed for simultaneous determination of chlordiazepoxide hydrochloride and mebeverine hydrochloride (Mixture I) and carvedilol and hydrochlorothiazide (Mixture II). The chromatographic separation in both mixtures was achieved by using an RP-C8 (octylsilyl) analytical column. For Mixture I, a mobile phase composed of acetonitrile-0.05 M disodium hydrogen phosphate-triethylamine (50 + 50 + 0.2, v/v/v), pH 2.5, was used; the detector wavelength was 247 nm. For Mixture II, the mobile phase consisted of acetonitrile-0.05 M disodium hydrogen phosphate (50 + 50, v/v), pH 4.0, and the detector was set at 220 nm. Quantification of the analytes was based on measuring their peak areas. Both mixtures were resolved in less than 6 min. The reliability and analytical performance of the proposed HPLC procedures were statistically validated with respect to linearity, range, precision, accuracy, selectivity, robustness, LOD, and LOQ. The linear dynamic ranges were 2.5-150 and 2.5-500 microg/mL for chlordiazepoxide HCI and mebeverine HCI, respectively, and 0.25-200 and 0.25-150 microg/mL for carvedilol and hydrochlorothiazide, respectively. The validated HPLC methods were successfully applied to the analysis of their commercial tablet dosage forms, for which no interfering peaks were encountered from common pharmaceutical adjuvants.  相似文献   

14.
Two simple and accurate methods for analysis of nebivolol hydrochloride (NEB) and hydrochlorothiazide (HCTZ) in their combined dosage forms were developed using first-order derivative spectrophotometry and reversed-phase liquid chromatography (LC). NEB and HCTZ in their combined dosage forms (tablets) were quantified using first-derivative responses at 294.6 and 334.6 nm in the spectra of their solutions in methanol. The calibration curves were linear in the concentration range of 8-40 microg/mL for NEB and 10-60 microg/mL for HCTZ. LC analysis was performed on a Phenomenex Gemini C18 column (250 x 4.6 mm id, 5 microm particle size) in the isocratic mode with 0.05 M potassium dihydrogen phosphate-acetonitrile-methanol (30 + 20 + 50, v/v/v; pH 4) mobile phase at a flow rate of 1 mL/min. Detection was made at 220 nm. Both of the drugs and the internal standard (ezetimibe) were well resolved with retention times of 5.1 min for NEB, 2.9 min for HCTZ, and 8.2 min for ezetimibe. The calibration curves were linear in the concentration range of 1-14 microg/mL for NEB and 0.3-28 microg/mL for HCTZ. Both methods were validated and found to be accurate, precise, and specific, and results were compared statistically. Developed methods were successfully applied for the estimation of NEB and HCTZ in their combined dosage forms.  相似文献   

15.
Losartan (LST) is the first orally active nonpeptide angiotensin-II receptor antagonist with an improved safety and tolerability profile. It is prescribed alone or in combination with hydrochlorothiazide (HCTZ) for the treatment of moderate-to-severe hypertension. This paper describes the development of 2 methods that use different techniques, first-derivative spectroscopy and high-performance thin-layer chromatography (HPTLC), to determine LST and HCTZ in the presence of each other. LST and HCTZ in combined preparations were quantitated by using the first-derivative responses at 271.6 nm for LST and 335.0 nm for HCTZ in spectra of their solutions in water. The linearity ranges are 30-70 microg/mL for LST and 7.5-17.5 microg/mL for HCTZ with correlation coefficients of 0.9998 and 0.9997, respectively. In the HPTLC method, a mobile phase of chloroform-methanol-acetone-formic acid (7.5 + 1.5 + 0.5 + 0.03, v/v) and a prewashed Silica Gel G60 F254 TLC plate as the stationary phase were used to resolve LST and HCTZ in a mixture. Two well-separated and sharp peaks for LST and HCTZ were obtained at Rf values of 0.61+/-0.02 and 0.41+/-0.02, respectively. LST and HCTZ were quantitated at 254.0 nm. The linearity ranges obtained for the HPTLC method are 400-1200 and 100-300 ng/spot with corresponding correlation coefficients of 0.9944 and 0.9979, for LST and HCTZ, respectively. Both methods were validated, and the results were compared statistically. They were found to be accurate, specific, and reproducible. The methods were successfully applied to the estimation of LST and HCTZ in combined tablet formulations.  相似文献   

16.
An accurate, simple, reproducible, and sensitive HPLC method was developed and validated for the simultaneous determination of atorvastatin calcium, ezetimibe, and fenofibrate in a tablet formulation. The analyses were performed on an RP C18 column, 150 x 4.60 mm id, 5 pm particle size. The mobile phase methanol-acetonitrile-water (76 + 13 + 11, v/v/v), was pumped at a constant flow rate of 1 mL/min. UV detection was performed at 253 nm. Retention times of atorvastatin calcium, ezetimibe, and fenofibrate were found to be 2.25, 3.68, and 6.41 min, respectively. The method was validated in terms of linearity, precision, accuracy, LOD, LOQ, and robustness. The response was linear in the range 2-10 microg/mL (r2 = 0.998) for atorvastatin calcium, 2-10 microg/mL (r2 = 0.998) for ezetimibe, and 40-120 microg/mL (r2 = 0.998) for fenofibrate. The developed method can be used for routine quality analysis of the drugs in the tablet formulation.  相似文献   

17.
A simple and highly sensitive LC/MS method was developed for the simultaneous determination of six ionophores--lasalocid, monensin, laidlomycin, maduramycin, salinomycin, and narasin--in feed. The procedure involved extraction of 1 g of feed with 4 mL of methanol-water (9 + 1, v/v) by shaking on a platform shaker for 45 min. After centrifugation, the extracts were diluted with methanol-water (75 + 25, v/v) and analyzed without any cleanup. The analysis was performed on a Betasil C18 column (150 x 4.6 mm id, 5 pm particle size) connected to an LC/MS system operated in the atmospheric pressure chemical ionization (APCI) mode. We believe this to be the first method that uses the APCI mode for the analysis of ionophores. The mobile phase consisted of 50 mM ammonium acetate as solvent A and acetonitrile-methanol (7 + 3, v/v) as solvent B in a gradient run. Excellent recoveries of 81-120% were found for all compounds at fortification levels of 1-200 microg/g, with RSD < or =15% (except 17% for maduramycin at 2 and 5 microg/g, and 16% for salinomycin at 1 microg/g). At 0.5 microg/g, recoveries of 87-119% were obtained, with RSD < or =20%. However, recovery of lasalocid was 133% and salinomycin 79% in sow and horse feed, respectively. Average RSD values of lasalocid and salinomycin were 22 and 21%, respectively. Finally, proficiency test samples analyzed with the method demonstrated favorable agreement with the certified values.  相似文献   

18.
A new, simple column reversed-phase high-performance liquid chromatographic (HPLC) method for simultaneous determination of rabeprazole sodium (RAB) and domperidone (DOM) in a combined tablet dosage form has been developed and validated. Determination was performed using a Jasco HPLC system with a HiQ SiL octadecylsilane (C18) column (250 x 4.6 mm id), acetonitrile-0.1 M ammonium acetate (50 + 50, v/v) mobile phase, and paracetamol as an internal standard. The detection was performed using a UV detector set at 280 nm. The method was validated with respect to linearity, accuracy, precision, and robustness. Beer's law was obeyed in the concentration range of 1.0-10.0 and 0.5-5.0 microg/mL for RAB and DOM, respectively. The method has been successfully applied for the analysis of drugs in a pharmaceutical formulation.  相似文献   

19.
Degradation products of egg phosphatidylcholine (EPC) and cholesterol were analyzed with different normal- and reversed-phase thin-layer chromatography (TLC) systems. The best separation, in terms of the highest number of degradation products from both analytes, was obtained with a reversed-phase system, using butanol-methanol-water-96-98% (v/v) acetic acid (40 + 40 + 20 + 4, v/v/v/v) as the mobile phase after overnight saturation at 25 degrees C. A special development technique was used. After a first development, the plate was dried and a second development was performed in the same direction. This method enabled us to separate lysophosphatidylcholine, several free fatty acids and hydroperoxides, and several undefined degradation products of EPC and cholesterol. All products were visualized after the plate was dipped in a 1% (v/v) solution of 4-methoxybenzaldehyde in 98% sulfuric acid-96-98% (v/v) acetic acid-ethanol-water (2 + 10 + 60 + 30), presenting a blue color or a white spot against a colored background. After activation at 110 degrees C, a stable color for both analytes was reached after 12 min. Precision of <5% was obtained at 2 levels of analysis. Good linearity was obtained in the range of 5-30 microg for EPC (r = 0.991) and 5-40 microg for cholesterol (r = 0.991). These results show that TLC can be an inexpensive and easy alternative for the analysis of EPC and cholesterol.  相似文献   

20.
A liquid chromatography (LC) method and an ultraviolet (UV) spectrophotometric method were developed and validated for quantitative determination of amlodipine in tablets and compounded capsules. The isocratic LC analyses were performed on an RP18 column using a mobile phase composed of 0.1% (v/v) ortho-phosphoric acid (pH 3.0) -acetonitrile (60 + 40, v/v) at a flow rate of 1.0 mL/min. The UV spectrophotometric method was performed at 238 nm. The analytical methods were validated according to International Conference on Harmonization Guidelines. The calibration graphs were linear [correlation coefficient (r) > 0.999] in the studied concentration range of 10-30 microg/mL for LC and 10-35 microg/mL for UV spectrophotometry. The relative standard deviation values for intraday and interday precision studies were less than 2%, and the accuracy was greater than 98% for both methods. The specificity of the LC method was proved using forced degradation. Statistical analyses showed no significant difference between the results obtained by the 2 methods. The proposed methods are precise and accurate and can be applied directly and easily to the oral pharmaceutical preparations of amlodipine.  相似文献   