共查询到17条相似文献,搜索用时 93 毫秒
1.
2.
Nafion修饰电极阴极溶出伏安法测定痕量钛 总被引:5,自引:0,他引:5
本文采用Nafion修饰玻碳电极阴极溶出伏安法测定痕量钛。研究了Nafion膜的有关特性和测定的佳化条件。当富集时间为1min时,Ti(Ⅳ)浓度与峰电流在1.0~50ng/ml范围内呈线性关系。本法应用于铝合金和白泥标样中钛的测定,结果满意。 相似文献
3.
银微盘电极上碘离子的示差脉冲溶出伏安法 总被引:6,自引:0,他引:6
基于I能与Ag生成难溶出化合物特性,在银微盘电极上研究了I的示差脉冲溶出伏安法(DPSV)。该法不需镀汞,不要搅拌,可在较稀稀的支持电解质溶液中实施。于0.08mol/LHAc-NaC及0.01mol/LEDTA介质中,能检出1.00×10^-8mol/L的I,I的浓度为5.00×10^-6--1.20×10^-8mol/L范围与峰电流有良好的线性关系。该法用于自来水中I的测定,相对偏差为4.3% 相似文献
4.
5.
Nafion—玻碳修饰电极阴极溶出伏安法测定痕量铋的研究 总被引:1,自引:0,他引:1
研究并提出在HNO_3-NaCl-硫脲(Tu)体系中,Nafion/玻碳(Gc)修饰电极阴极溶出伏安法测定痕量鉍的方法。表明Tu具络合协同作用,使Nation阳离子交换能力提高。本法检出限为5×10~(-9)mol/L Bi~(3+)(td:5min),电极表面易于再生,文中研究了电极过程机理,计算得[Bi(Tu)_6]~(3+)在Nafion膜中的分配系数(K_D),扩散系数(D)和选择性系数(K_H~[Bi(Tu)_6~+]~(3+))分别为7.57×10~5,5.9×10~(-11)cm~2/s及3.39。 相似文献
6.
阴极溶出伏安法测定异烟肼的研究 总被引:1,自引:0,他引:1
报道了吸附阴极溶出伏安法测定异烟肼。探讨了电极反应机理。在0.01mgol/L硼砂底液中,峰电位为-1.40V。峰电流与异烟肼浓度在4.0*10^-7-1.5*10^-5mol/L范围内呈良好的线性关系,相关系为0.9913。该方法用于异烟肼片剂的测定,获得满意结果。 相似文献
7.
本文用热处理法成功地制备了性能稳定的Eastman-Kodak AQ/GC修饰电极,对Fe~(3+)/Fe~(2+)及其络合阳离子在该电极上的行为进行了研究。表明AQ膜对Fe~(3+)和Fe~(2+)具有相近的交换能力,可用于Fe~(3+)或Fe~(2+)及其总量的阴极溶出伏安法测定。线性范围分别为2.0×10~(-7)~2.2×10~(-5)mol/L(Fe~(3+))和5.0×10~(-7)~2.0×10~(-5)mol/L(Fe~(2+)),检出限为1.0×10~(-7)mol/L(Fe~(3+))。文中对电极反应和再生进行了探讨。 相似文献
8.
9.
10.
11.
12.
《Analytical letters》2012,45(15):2743-2753
Abstract The electrochemical behavior of 6-MP was studied by cyclic voltammetry at a hanging copper amalgam dropping electrode (HCADE). It was found that 6-MP could form a complex with the Cu(II) stripped from the HCADE, showing a new peak at ?0.19V in the medium of 0.1mol/L LiClO4-0.5mol/L HClO4 solution. The mechanism of the reaction was proposed. This new peak was sensitive and could be used for the determination of trace 6-MP by differential pulse adsorption cathodic stripping voltammetry (DPAdCSV). The linear range was from 3.6×10?10 to 5.3×10?6 mol/L, and the detection limit was about 1.2×10?10 mol/L (S/N=3). The method was also successfully applied to the determination of 6-MP in pharmaceutical tablets. 相似文献
13.
《Analytical letters》2012,45(12):887-892
Abstract The experimental conditions for the accumulation of cerium as insoluble Ce3(PO4)4 on a platinum indicator electrode were studied. The determination of cerium down to 0.01% in oxides of other lanthanides is described. 相似文献
14.
《Electroanalysis》2017,29(3):686-695
In this work, we report on the determination of trace manganese (Mn) using cathodic stripping voltammetry (CSV) using a microfabricated sensor with a Pt thin‐film working electrode. While an essential trace metal for human health, prolonged exposure to Mn tends to gradually impair our neurological system. The potential sources of Mn exposure make it necessary to monitor the concentration in various sample matrices. Previous work by us and others suggested CSV as an effective method for measuring trace Mn. The analytical performance metrics were characterized and optimized, leading to a calculated limit of detection (LOD) of 16.3 nM (0.9 ppb) in pH 5.5, 0.2 M acetate buffer. Further, we successfully validated Mn determination in surface water with ∼90% accuracy and >97% precision as compared with inductively coupled plasma mass spectrometry (ICP‐MS) “gold standard” measurement. Ultimately, with stable, accurate and precise electrochemical performance, this Pt sensor permits rapid monitoring of Mn in environmental samples, and could potentially be used for point‐of‐use measurements if coupled with portable instrumentation. 相似文献
15.
银微盘电极上头孢氨苄降解产物的伏安行为及其应用 总被引:9,自引:3,他引:9
基于头孢氨苄降解产物中含有巯基,能与Ag^+生成难溶化合物的特性,在银微盘电极上研究了CEX降解产物的伏安行为,探讨了电极反应的机理。运用示差脉冲溶出伏安法,在0.1mol/L HAc-NaAc介质中,CEX降解产物的还原峰电流与CEX浓度于8.0×10^-8-7.0×10^-6mol/L范围内呈良好线性关系;检测限为1.0×10^08mol/L;测定了头孢氨苄胶囊中CEX含量为92.0%,与药典 相似文献
16.
《Analytical letters》2012,45(10):659-670
Abstract The oxidation of Fe(II) in the presence of phosphate results in a film of a sparingly soluble Fe(III) phosphate salt on a glassy carbon electrode. The reaction is used as the preconcentration step in a cathodic stripping method for phosphate. The recommended procedure yields working curves which are linear over single orders-of-magnitude down to 0.1 ppm, With a 40-minute preconcentration time, 40 ppb phosphate can be detected. The method is free of interference by chloride and sulfate. 相似文献
17.
《Analytical letters》2012,45(19):2141-2157
Abstract A technique is presented for the determination of trace concentrations of copper (II) in natural water samples by cathodic stripping voltammetry of a film of copper-catechol complex ions adsorbed on the hanging mercury drop electrode. The peak height of the copper-catechol reduction peak is linearly dependent upon the copper (II) concentration between 10?10 and 10?7 M. The detection limit of the technique is below 10?10 M copper (II) for a collection time of 3 minutes, but the sensitivity can be further increased four-fold by collecting for 15 minutes. The sensitivity is reduced by high concentrations of competing trace metals and of surfactants, which necessitate the use of standard additions to the sample. 相似文献