首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
Molecularly imprinted polymers (MIPs) are synthetic polymers designed to selectively extract target analytes from complex matrices (including biological matrices). The literature shows that MIPs have a degree of cross-selectivity from analytes within the same class of compounds. A commercially available MIP for tobacco-specific nitrosamines (TSNAs) is designed to be class selective for four TSNA compounds. This study sought to characterize the extent of cross-selectivity of the TSNA MIPs with other tobacco alkaloids. Cross-selectivity and recovery of the SupelMIP™ TSNA SPE cartridges was assessed with N-nitrosonornicotine (NNN), nicotine, cotinine and morphine. Their recoveries were compared with the recoveries of a nonimprinted polymer SPE cartridge, and two traditional SPE cartridges: a Waters mixed-mode cation exchange cartridge and a Waters hydrophilic–lipophilic balance cartridge. NNN and cotinine had the highest recoveries with the MIP cartridge, over 80%, and cotinine samples in urine had >80% recoveries. Nicotine had highly variable recoveries, possibly owing to differing chemical properties from the TSNAs. All three analytes had significantly different recoveries with the MIP cartridges compared with the traditional SPE cartridges. Morphine displayed nonspecific interactions with the MIP cartridges. Utilization of the TSNAs’ cross-selectivity allows for simultaneous extraction and identification of multiple tobacco biomarkers using one extraction technique.  相似文献   

2.
In order to establish the hierarchical structure in multiple levels on mesoporous silica, this article reports a new strategy to prepare the monolith with the pore configuration in nanometer scale, micro-morphology in micrometer level and macroscopic shape in millimeter or larger grade. These hierarchical monoliths are synthesized in a weak acidic condition by using triblock copolymer P123, hydroxyl carboxylic acid and tetramethyl orthosilicate (TMOS), and the textural properties of the mesostructure can be facilely adjusted by simply controlling the synthesis condition without any additive. During the synthesis, the primary particles can be selectively synthesized as monodispersed sphere, noodle, prism, straight rods with different size or irregular bars, and their connection plus arrangement in 3D directions can be also regulated. Therefore, various textural properties of mesopore are able to be altered including pore size (5.5-10.6 nm), total pore volume (0.48-1.2 cm(3) g(-1)), micropore surface area (47-334 m(2) g(-1)), and pore shape (from 2D or 3D straight channel to plugged channel). Moreover, these monoliths exhibit a considerable mechanical strength; they are also applied in eliminating particulate matters and tobacco special nitrosamines (TSNA) in tobacco smoke, exhibiting various morphology-assisted functions.  相似文献   

3.
A specific and sensitive method was developed and validated to quantitatively analyze four tobacco-specific nitrosamines (TSNAs) in the particulate phase of mainstream cigarette smoke. Cigarette smoke particulate matter was collected according to ISO 4387. The particulate matter was extracted with acetic ether, cleaned up with a Supelclean ENVI-Carb silod-phase extraction (SPE) cartridge, concentrated under the protection of nitrogen and analyzed by gas chromatography (GC)/ion trap mass spectrometry (MS) with a very-low-flow-loss column (VF-17 MS) in MS(n) mode using N-nitrosopentyl-3-picolylamine (NNPA) as an internal standard. TSNAs were identified by chromatographic retention time, matching the spectra of the standards and the samples and the consistency of the ratio of the abundance of the ions detected in the standards and the samples. Limits of detection of each TSNA varied from 0.01 to 0.06 ng/cig. A linear calibration range for this method is large enough to measure TSNA levels in cigarette smoke. The recovery of each TSNA was from 91.5 to 102.7%. The method achieved excellent reproducibility (RSD: 1.8-4.8% for intra-assay, 3.4-7.1% for inter-assay). It also shows no evidence of artifact formation. This method is very suitable for the routine detection of TSNAs in mainstream cigarette smoke.  相似文献   

4.
A organically modified molecularly imprinted silica (MIS), selective for methylxanthines, was prepared using a simple sol-gel procedure. Caffeine was used as template; 3-aminopropyltrimethoxysilane (APTMS) as functional monomer and tetraethyl orthosilicate (TEOS) as reticulating agent. The material was packed on solid-phase extraction (SPE) cartridges and evaluated with aqueous test samples, natural water and human urine; a quantitative method for methylxanthines in water, using SPE cartridges packed with the MIS coupled with HPLC-UV was developed. The MIS was highly specific for methylxanthines, with an imprinting factor of (20.5+/-1.9). The analytical method resulted in detection limits of 85 microgL(-1) for theobromine, 44 microgL(-1) for theophylline and 53 microgL(-1) for caffeine.  相似文献   

5.
建立了卷烟丝中烟草特有亚硝胺类化合物(TSNAs)的SPE-LC/MS/MS分析方法,可一次性对卷烟烟丝中4种TSNAs进行定量分析.该方法弥补了传统的烟丝中TSNAs分析方法样品处理步骤多,检出限高,适应范围窄等缺点.4种TSNA的回收率的范围在95.7%~99.2%之间;相对标准偏差均小于8%;方法检出限均低于1.0 ng/g.可应用于国内外各类型卷烟的分析.  相似文献   

6.
Tobacco‐specific nitrosamines are one of the most important groups of carcinogens in tobacco products. Using adsorbents as filter additives is an effective way to reduce tobacco‐specific nitrosamines in cigarette smoke. Molecularly imprinted polymers (MIPs) using nicotinamide as template were grafted on the silica gel surface to obtain MIP@SiO2 and employed as filter additives to absorb tobacco‐specific nitrosamines in mainstream cigarette smoke. Four milligrams of MIP@SiO2 per cigarette was added to the interface between filter and tobacco rod to prepare a binary filter system. The mainstream smoke was collected on an industry‐standard Cambridge filter pad and extracted with ammonium acetate aqueous solution before analysis. Compared to the cigarette smoke of the control group, the levels of tobacco‐specific nitrosamines with silica gel and with MIP@SiO2 were both reduced, and the adsorption rates of N‐nitrosonornicotine, N‐nitrosoanabasine, N‐nitrosoanatabine, and 4‐(methylnitrosamino)‐1‐(3‐pyridine)‐1‐butanone with silica gel and with MIP@SiO2 were 20.76, 15.32, 18.79, and 18.01%, and 41.33, 34.04, 37.86, and 35.53%, respectively. Furthermore the content of total particle materials in cigarette smoke with silica gel was decreased evidently but showed no observable change with MIP@SiO2. It indicated MIP@SiO2 could selectively reduce tobacco‐specific nitrosamines in the mainstream cigarette smoke with no change to the cigarette flavor.  相似文献   

7.
Tobacco-specific nitrosamines (TSNAs) are some of the most potent carcinogens in tobacco and cigarette smoke. Accurate quantification of these chemicals is needed to help assess public health risks. We developed and validated a specific and sensitive method to measure four TSNAs adsorbed to model surfaces and secondhand smoke (SHS) particles using gas chromatography–ion-trap tandem mass spectrometry. In an 18-m3 room-sized chamber, a smoking machine generated realistic concentrations of SHS that were actively sampled on Teflon-coated fiber glass (TCFG) filters, and passively sampled on cellulose substrates. A simple solid–liquid extraction protocol using methanol as solvent was successfully applied to both substrates with recoveries ranging from 85 to 115%. For each TSNA, tandem MS parameters were optimized and the major fragmentation pathways were elucidated. The method showed excellent performance, with a linear dynamic range from 2 to 1000 ng mL−1, low detection limits (S/N > 3) of 30–300 pg mL−1 and precision with experimental errors below 10% for all compounds. Moreover, no interfering peaks were observed, indicating a high selectivity of MS/MS without the need for a sample clean-up step. This method provides a suitable analytical tool to detect and quantify traces of TSNA in indoor environments polluted with SHS.  相似文献   

8.
A fully automated procedure is proposed for the Fourier transform infrared (FTIR) determination of nicotine in tobacco. The method is based on the on-line extraction of nicotine with CHCl3. Samples, weighed inside empty extraction cartridges, were humidified with NH3 and the cartridges were installed in a flow manifold in which they were extracted with 2 ml CHCl3 for 2 min, then 400 microliters of the extract were introduced into a micro-flow cell using a carrier of CHCl3 and the IR spectrum was registered continuously. The absorbance, in the wavenumber range 1334-1300 cm-1, was measured, obtaining a peak as a function of time. The area of this peak was interpolated on a calibration line established from standard solutions of nicotine in chloroform treated in the same way as samples. The method provided a limit of detection of 0.1 mg ml-1 nicotine, an RSD lower than 2% and a sampling frequency of the whole procedure of 6 h-1. Results obtained for natural samples of cut tobacco and cigar compared well with those obtained by a batch FTIR procedure, involving an off-line extraction with a total time of 16 min. However, for yellow tobacco cigarette, an on-line extraction time of 10 min was required to obtain a good recovery of nicotine.  相似文献   

9.
A liquid chromatography tandem mass spectrometry (LC/MS/MS) method was developed and validated for the determination of five total tobacco‐specific N‐nitrosamines (TSNA), including free and conjugated forms in urine. The limits of detection for 4‐(methylnitrosamino)‐1‐(3‐pyridyl)‐1‐butanol, N′‐nitrosonornicotine, 4‐(methylnitrosamino)‐1‐(3‐pyridyl)‐1‐butanone, N′‐nitrosoanatabine and N′‐nitrosoanabasine were 0.6, 0.6, 10.0, 0.4 and 0.4 pg/mL, respectively, with a linear calibration range of up to 20,000 pg/mL. Intra‐ and inter‐day precision for TSNA measurements ranged from 0.82 to 3.67% and from 2.04 to 7.73% respectively. For total TSNAs, the β‐glucuronidase amount was optimized for hydrolysis time and yield. Different liquid chromatography columns and mobile phases with different pH conditions were evaluated. The validated method was then applied to 50 smoker and 30 nonsmoker urine samples. Our results suggest that this sensitive and relatively simple analytical method is suitable for application to epidemiological investigations of health risks associated with the exposure to tobacco smoke or secondhand smoke in both smokers and nonsmokers. Published 2013. This article is a U.S. Government work and is in the public domain in the USA.  相似文献   

10.
Quantitation of nicotine in tobacco products by capillary electrophoresis   总被引:3,自引:0,他引:3  
A simple and rapid capillary electrophoresis (CE) method was developed for the quantitation of nicotine in commercial tobacco products. The method involves a 6 min run at 30 kV, using a 50 mM phosphate buffer (pH 2.5), paraquat as internal standard, and UV detection at 260 nm. Nicotine was extracted from tobacco products in <15 min. Recoveries from spiked extracts were >95%, and the extraction efficiencies of water, 1 M HCI, 1 M acetic acid, 5 mM phosphate buffer (pH 2.5), and 1% triethanol amine were similar. Nicotine concentrations in 67 samples of cigarettes, cigars, and bidis varied between 0.37 and 2.96% (w/w). An established gas chromatography/mass spectrometry method using toluene extraction consistently yielded lower nicotine values than the CE method. Experimental evidence suggests that this is due to insufficient extraction of nicotine by toluene.  相似文献   

11.
A new procedure using C18 and silica cartridges for the extraction and subsequent separation of vitamin D and its major metabolites from plasma has been developed and compared to a conventional extraction procedure with respect to lipophilic material extracted as evaluated by high-performance liquid chromatographic profiles. The C18 cartridges were efficient in extracting all compounds tested while subsequent chromatography of the extract on silica cartridges was effective in resolving vitamin D and its metabolites based on increasing polarity. High-performance liquid chromatographic profiles of each silica cartridge fraction clearly demonstrated that the newly conceived solid phase extraction was superior to conventional extraction methods with respect to cleanliness of sample fractions. This difference in lipophilic load between the new and conventional extraction systems was most apparent in the vitamin D and 25-hydroxyvitamin D containing fractions. The new extraction system can be used when total extraction and subsequent analysis of vitamin D and its major metabolites is desired.  相似文献   

12.
Various solid-phase extraction (SPE) procedures for clean-up, two perfluoroacylation reagents (pentafluoropropionic anhydride (PFPA) and heptafluorobutyric anhydride (HFBA)) and two chromatographic columns (HP-1701 and HP-5) have been assessed comparatively to achieve the determination of type B trichothecenes (deoxynivalenol (DON), nivalenol (NIV), 3- and 15-acetyldeoxynivalenol (3- and 15-ADON)) in wheat grain by gas chromatography (GC)-electron-capture detection (ECD). Spiked wheat samples were extracted with acetonitrile-water (84:16, v/v). Tested SPE procedures were MycoSep 225 column, Florisil and different cartridges prepared in the laboratory with mixtures of various sorbents like alumina, Celite 545, C18, silica and charcoal. We propose MycoSep 225 column, and cartridges made with alumina-charcoal-silica and alumina-charcoal-C18 silica mixtures as clean-up procedures on the basis of recovery values (89.6, 87.3 and 86.1% for deoxynivalenol, respectively, at 1.0 mg/kg spiking level). The two last procedures are less expensive. Pentafluoropropionic anhydride was more stable against moisture and less expensive, while recoveries were similar to those obtained with heptafluorobutyric anhydride. HP-1701 column can separate 3- and 15-acetyldeoxynivalenol derivatives while HP-5 cannot, although this last column provided lower bleed and better sensitivity.  相似文献   

13.
A method is described for the determination of non-volatile N-nitrosamines in baby bottle rubber nipples and pacifiers. It consists of extraction of the sample with dichloromethane in the presence of ascorbyl palmitate (an inhibitor of artifactual formation of nitrosamines), clean-up on silica or basic alumina, and final analysis by high-performance liquid chromatography-thermal energy analysis, a technique which is highly specific for N-nitroso compounds. The method worked well for the determination of four rubber-related non-volatile nitrosamines, namely, N-nitrosomethylphenylamine, N-nitrosoethylphenylamine, N-nitrosodicyclohexylamine, and N-nitrosodibenzylamine (recoveries from spiked samples greater than 80%; detection limit, ca. 5 micrograms/kg for each). Eighteen out of twenty four samples analyzed were found to contain varying levels (mean, 41 micrograms/kg; range, 8-146 micrograms/kg) of N-nitrosodibenzylamine. The identity of the compound was confirmed by gas chromatography-thermal energy analysis as well as by gas chromatography-mass spectrometry analyses.  相似文献   

14.
A comparison of SPE cartridges produced in authors laboratory containing silica modified by addition of three functional moieties with standard C-18 and SDVB cartridges was made in terms of their applicability for the isolation of flavor compounds. Compounds found in wine and grapes were used for model mixture, which was spiked into a grape juice. Functionalized phases for SPE were prepared modifying silica gel with alkoxysilanes with different functional groups: (3-(phenylamino)-propyltrimethoxysilane, octyltriethoxysilane and octadecyl-silane. The functionalization was carried out by the dry method, which resulted 5, 10 and 20 weight parts of initial support. Functionalized phases were characterized using FT-IR, elemental analysis and NMR.Performance for new phases compared to “standard” ones (C-18 and SDVB (styrene–divinylbenzene) varied, depending on the group or type of analyzed compound. They were more efficient in extraction of methyl anthranilate and vanilins. For extraction of terpenes, C-6 alcohols, isoprenoids, benzene derivatives and phenols their efficiency was comparable to that of C-18.Functionalized laboratory-made mixed phases are suitable for extraction of flavor compounds from grape juice. They are suitable for extraction of compounds belonging to different chemical classes with the efficiency comparable to C-18 and SDVB phases. The production of such functionalized phases can be easily performed in the laboratory, at a very low cost, comparing to C-18 or SDVB cartridges. This makes the proposed functionalized phases an interesting alternative, in sample preparation for analysis and particularly in preparative/flash chromatography.  相似文献   

15.
Formaldehyde, acetaldehyde, ozone and nitrogen dioxide in ambient air are simultaneously collected on silica gel cartridges coated with 1-methyl-1-(2,4-dinitrophenyl)hydrazine (MDNPH), where the two aldehydes are derivatized to their respective hydrazones, while the two oxidants are converted into N-methyl-2,4-dinitroaniline (MDNA). The three products are then separated and quantified by HPLC with UV detection at 360 nm. The stoichiometric factors of the MDNPH reactions with O3 and NO2 in laboratory tests correspond to 2.0 +/- 0.1 moles of MDNA per mole of O(x) (O3 + NO2). The limits of detection (LOD) are 0.7 ppbv HCHO, 0.8 ppbv CH3CHO and 1.6 ppbv O(x) for 30 L (1 h) air sampled. The sampling performance is insensitive to relative humidities encountered in real atmospheres. When compared with Sep-Pak DNPH silica cartridges as well as with ozone photometric and nitrogen dioxide chemiluminescent analyzers, the proposed chromatographic method demonstrates a very good accuracy (12% for HCHO, 14% for CH3CHO and 7% for O(x), on the average) under field sampling conditions at concentrations lower than 3 and 1 ppbv, for HCHO and CH3CHO, respectively and ranging from 28 to 62 ppbv for O(x).  相似文献   

16.
A rapid method for the selective determination of four kinds of tobacco‐specific nitrosamines, N‐nitrosonornicotine, N‐nitrosoanatabine, N‐nitrosoanabasine and 4‐(methylnitrosamino)‐1‐(3‐pyridyl)‐1‐butanone, in mainstream cigarette smoke was developed by GC coupled to positive chemical ionization triple‐quadrupole MS. After mainstream cigarette smoke was collected on a cambridge filter pad, the particulate matter was extracted with 0.1 M HCL aqueous solution, cleaned by positive cation‐exchange solid extraction, and finally injected into GC–MS/MS using isotopically labeled analogues as internal standards. Excellent linearity was obtained over the concentration range of 0.5–200.0 ng mL?1 for all tobacco‐specific nitrosamines with values for correlation coefficient between 0.9996–0.9999. Limits of detection of each tobacco specific nitrosamine varied from 0.023–0.028 ng cig?1, and lower limits of quantification varied from 0.077–0.093 ng cig?1. The recovery of each tobacco specific nitrosamine was from 90.0–109.0%. The relative standard deviations of the intra‐day and inter‐day precisions were 3.1–5.8 and 3.9–6.6, respectively. This method was applied to reference and domestic cigarettes. The result showed that the method was consistent with traditional methods and can be used as an effective approach for the routine analysis of tobacco‐specific nitrosamines.  相似文献   

17.
G H Tan 《The Analyst》1992,117(7):1129-1132
Solid-phase extraction (SPE) of organochlorine pesticide residues from environmental water samples was evaluated using octadecyl (C18)-bonded porous silica. The efficiency of SPE of these pesticide residues from reagent water samples at 1-5 micrograms dm-3 levels was compared with those obtained by solvent extraction with hexane and Freon TF (trichlorotrifluoroethane). Average recoveries exceeding 80% for these organochlorine pesticides were obtained via the SPE method using small cartridges containing 100 mg of 40 microns C18-bonded porous silica. The average recovery by solvent extraction with hexane and Freon TF exceeded 90% in both instances. It was concluded that the recoveries and precision for the SPE of organochlorine pesticides were poorer than those for the solvent extraction method. Organochlorine pesticide residue levels in environmental water samples from two major rivers flowing through predominantly rice-growing areas were monitored by gas chromatography using the solvent extraction method with hexane. Exceptionally high levels of organochlorine pesticide residues such as BHC, DDT, heptachlor, endosulfan and dieldrin were found in these water samples.  相似文献   

18.
Active and passive smoking are serious public health concerns Assessment of tobacco smoke exposure using effective biomarkers is needed. In this study, we developed a simultaneous determination method of five tobacco-specific nitrosamines (TSNAs) in hair by online in-tube solid-phase microextraction (SPME) coupled to liquid chromatography-tandem mass spectrometry (LC–MS/MS). TSNAs were extracted and concentrated on Supel-Q PLOT capillary by in-tube SPME and separated and detected within 5 min by LC–MS/MS using Capcell Pak C18 MGIII column and positive ion mode multiple reaction monitoring systems. These operations were fully automated by an online program. The calibration curves of TSNAs showed good linearity in the range of 0.5–1000 pg mL–1 using their stable isotope-labeled internal standards. Moreover, the limits of detection (S/N = 3) of TSNAs were in the range of 0.02–1.14 pg mL–1, and intra-day and inter-day precisions were below 7.3% and 9.2% (n = 5), respectively. The developed method is highly sensitive and specific and can easily measure TSNA levels using 5 mg hair samples. This method was used to assess long-term exposure levels to tobacco smoke in smokers and non-smokers.  相似文献   

19.
Solid-phase extraction methods using pre-packed silica cartridges and various elution solvents have been developed and evaluated as chromatographic means to enrich biological lipid extracts for platelet-activating factor (PAF). The optimized procedure advanced selectively removed the major tissue/blood neutral lipids and non-choline-containing phospholipids from complex lipid mixtures and yielded thereby a choline phospholipid fraction markedly enriched in bioactive PAF. Some tested solid-phase extraction procedures, while capable of resolving choline phospholipids from other polar and non-polar species, were detrimental to PAF's bioactivity and evidenced considerable loss or degradation of this analyte. It is concluded that, with solvents of appropriate composition, strength and polarity, solid-phase extraction on silica cartridges has several unique advantages over conventional thin-layer and column chromatographic methods presently in use for PAF enrichment from biological sources.  相似文献   

20.
Determination of phospholipids in dairy products by SPE/HPLC/ELSD   总被引:10,自引:0,他引:10  
The aim of this work was to evaluate the performance of different methods for both milk lipid extraction and phospholipids separation. As far as the lipid extraction procedure is concerned, the Folch method showed a higher phospholipid recovery with respect to the Rose-Gottlieb method. Different SPE cartridges and solvent phases were tested to carry out the separation of phospholipids from fat. The yield of extraction was evaluated by isolating phospholipids from both milk fat and synthetic fat; Standard Addition Method was applied as well. The isolation of the phospholipids by SPE silica column and subsequent analysis by HPLC/ELSD was shown to be an accurate and reproducible analytical method for the determination of phosphatidylethanolamine, phosphatidylinositol, phosphatidylserine, phosphatidylcholine and sphingomyelin in milk fat extracted by Folch method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏