首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Products of the radical dispersion copolymerization of methacryloyl‐terminated poly(ethylene oxide) (PEO) macromonomer and styrene were separated and characterized by size exclusion chromatography (SEC), full adsorption‐desorption (FAD)/SEC coupling and eluent gradient liquid adsorption chromatography (LAC). In dimethylformamide, which is a good solvent for PEO side chains but a poor solvent for polystyrene (PS), amphiphilic PS‐graft‐PEO copolymers formed aggregates, which were very stable at room temperature even upon substantial dilution. The aggregates disappeared at high temperature or in tetrahydrofuran (THF), which is a good solvent for both homopolymers and for PS‐graft‐PEO. FAD/SEC procedure allowed separation of homo‐PS from graft‐copolymer and determination of both its amount and molar mass. Effective molar mass of graft‐copolymer was estimated directly from the SEC calibration curve determined with PS standards. Presence of larger amount of the homo‐PS in the final graft‐copolymer products was also confirmed with LAC measurements. The results indicate that there are at least two or maybe three polymerization loci; namely the continuous phase, the particle surface layer and the particle core. The graft copolymers are produced mainly in the continuous phase while PS or copolymer rich in styrene units is formed mostly in the core of monomer‐swollen particles. © 2000 John Wiley & Sons, Inc. J Polym Sci A: Polym Chem 38: 2284–2291, 2000  相似文献   

2.
High-performance liquid chromatography (HPLC) has been used to complement size-exclusion (gel permeation) chromatography (SEC) for the characterization of functional polymers. Whereas SEC is unable to detect compositional changes, HPLC in an appropriate interacting medium can provide detailed information on compositional changes occurring during chemical modification of a polymer. The method has been demonstrated using a normal-phase column consisting of porous monodisperse 10 μm poly(2,3-dihydroxypropyl methacrylate-co-ethylene dimethacrylate) beads that have a homogeneous coverage of aliphatic hydroxyl groups for the analysis of brominated poly(isobutylene-co-4-methylstyrene). Differences of well below 1 mol % of bromomethylstyrene units are easily detected and quantified. © 1997 John Wiley & Sons, Inc. J Polym Sci A: Polym Chem 35: 1173–1180, 1997  相似文献   

3.
Ultrashort monolithic columns (disks) were thoroughly studied as efficient stationary phases for precipitation–dissolution chromatography of synthetic polymers. Gradient elution mode was applied in all chromatographic runs. The mixtures of different flexible chain homopolymers, such as polystyrenes, poly(methyl methacrylates), and poly(tert‐butylmethacrylates) were separated according to their molecular weights on both commercial poly(styrene‐co‐divinylbenzene) disks (12 id × 3 mm and 5 × 5 mm) and lab‐made monolithic columns (4.6 id × 50 mm) filled with supports of different hydrophobicity. The experimental conditions were optimized to reach fast and highly efficient separation. It was observed that, similar to the separation of monoliths of other classes of (macro)molecules (proteins, DNA, oligonucleotides), the length of column did not affect the peak resolution. A comparison of the retention properties of the poly(styrene‐co‐divinylbenzene) disk‐shaped monoliths with those based on poly(lauryl methacrylate‐co‐ethylene dimethacrylate), poly(butyl methacrylate‐co‐ethylene dimethacrylate), and poly(glycidyl methacrylate‐co‐ethylene dimethacrylate) supports demonstrated the obvious effect of surface chemistry on the resolution factor. Additionally, the results of the discussed chromatographic mode on the fast determination of the molecular weights of homopolymers used in this study were compared to those established by SEC on columns packed with sorbent beads of a similar nature to the monoliths.  相似文献   

4.
Polyhydroxyalkanoates are biodegradable polyesters produced by bacteria that can have a wide distribution in molecular weight, composition of monomers, and functionalities. This large distribution often leads to unpredictable physical properties making commercial applications challenging. To improve polymer homogeneity and obtain samples with a clear set of physical characteristics, poly-3-hydroxyvalerate-co-3-hydroxybutyrate copolymers were fractionated using gradient polymer elution chromatography (GPEC) as opposed to extensively used bulk fractionation. Separation was achieved using a reversed-phase column with chloroform and ethanol as the solvent and non-solvent, respectively. A separation was also conducted on a normal-phase column to compare elution patterns between columns of varied polarity. The fractions were analyzed using Size Exclusion Chromatography (SEC) and NMR to determine the percentage of 3-hydroxyvalerate in the copolymer as well as its molecular weight. It was found that as the percentage of "good" solvent was increased in the mobile phase, the polymers eluted with decreasing percentage of 3-hydroxyvalerate and increasing molecular weight which indicates the importance of precipitation/redissolution in the separation. The elution pattern of the polymer remained unchanged when using both a normal- and reversed-phase column which also illustrates the dominance of precipitation/redissolution in GPEC of polyhydroxyalkanoates. As such, GPEC is shown to be an excellent choice to provide polyhydroxyalkanoate samples with a narrower distribution in composition than the original bulk copolymer sample.  相似文献   

5.
A novel porous polymeric monolithic column based on poly(high internal phase emulsion) methacrylate monolith was prepared and applied to fast separation of proteins. The block copolymer chemistry of high internal phase emulsions was used in the experiment. These unique properties, together with high porosity, good mechanical property, chemical modification of the surface make themselves superior in monolithic medium applications. Morphology of the monolithic material was studied by scanning electron microscopy. The stability of the emulsion and the load of hydroxyl groups–the active group of the monolithic column were investigated. Additionally, the capabilities of separation of this column in conjunction with high performance liquid chromatography (HPLC) were investigated. Immunoglobulin was separated from human plasma and chicken egg yolk with high resolution on the hydrophobic interaction chromatographic column in a short time. The effects of pH and concentration of mobile phase (buffer) on the elution of immunoglobulin were investigated. Moreover, fast separation of a two mode protein mixture (α‐amylase and lysozyme) on the monolith was achieved within 1.5 min at a velocity of 1445 cm·h?1. As a result, good separation was achieved, and stable low back pressure drop was ensured at high throughput elution with an even longer column.  相似文献   

6.
Three monomers, octakis (3‐mercaptopropyl) octasilsesquioxane, 1,2,4‐trivinylcyclohexane and isophytol were employed to synthesize a novel monolithic stationary phase via photo‐initiated thiol‐ene click polymerization for reversed‐phase liquid chromatography. Several factors such as porogenic system, reaction time and the molar ratio of functional groups were investigated in detail. The resulting poly(POSS‐co‐TVCH‐co‐isophytol) monolithic column exhibited suitable permeability for fast separation and outstanding thermal stability. Five alkylbenzenes were employed to evaluate the ability of chromatographic separation of the resulting monolithic columns at different flow rates, and showed the highest column efficiencies of 90,200–93,100 N/m (corresponding to 10.4–10.6 μm of plate height) at a velocity of 0.41 mm/s. The baseline separations of five anilines and eight phenols further proved the applicability of poly(POSS‐co‐TVCH‐co‐isophytol) monolithic column in the separation of small molecules.  相似文献   

7.
Temperature rising elution fractionation hyphenated to size exclusion chromatography (TREF × SEC) is a routine technique to determine the chemical heterogeneity of semicrystalline olefin copolymers. A serious limitation is its applicability to non crystallizing samples. Comprehensive high temperature two-dimensional liquid chromatography (HT 2D-LC) gives an alternative to characterize the chemical heterogeneity of copolymers irrespective of their crystallizability. We have hyphenated interactive HPLC, which separates polyolefins according to their chemical composition, with high-temperature size exclusion chromatography (SEC), which distinguishes polyolefins with regard to their molar mass at 160 °C. The first separation step was based on a selective adsorption of macromolecules on a Hypercarb® column packed with porous graphite particles and subsequent desorption by a gradient 1-decanol → 1,2,4-trichlorobenzene at 160 °C. The SEC column was calibrated with polypropylene (PP) and polyethylene (PE) standards and it turned out that the injection solvent from the first dimension influenced the elution of PP in the SEC column, while the retention of PE was virtually constant. HT 2D-LC was then used to separate a broad variety of polyolefin blends containing PE, PP with different microstructure, ethylene–propylene (EP) and ethylene–propylene–diene (EP(D)M) rubber and ethylene/1-hexene copolymers. For the first time it has been shown that the elution of iPP in the gradient HPLC is molar mass dependent. The results from the HT 2D-LC separation were compared to those from TREF × SEC-experiments. The particular advantage of HT 2D-LC over TREF × SEC is the fact that HT 2D-LC is also applicable to non crystallizing polyolefin samples. The new technique therefore resolves the problem to analyze the chemical heterogeneity of non crystallizing olefin copolymers like EP and EP(D)M copolymers.  相似文献   

8.
A new approach to the preparation of enantioselective porous polymer monolithic columns with incorporated chiral metal–organic framework for nano‐liquid chromatography has been developed. While no enantioseparation was achieved with monolithic poly(4‐vinylpyridine‐co‐ethylene dimethacrylate) column, excellent separations of both enantiomers of (±)‐methyl phenyl sulfoxide were achieved with its counterpart prepared after admixing metal–organic framework [Zn2(benzene dicarboxylate)(l‐lactic acid)(dmf)], which is synthesized from zinc nitrate, l ‐lactic acid, and benzene dicarboxylic acid in the polymerization mixture. These novel monolithic columns combined selectivity of the chiral framework with the excellent hydrodynamic properties of polymer monoliths, may provide a great impact on future studies in the field of chiral analysis by liquid chromatography.  相似文献   

9.
With the explosive growth of the bioscience and biopharmaceuticals, the demand for high efficient analysis and separation of proteins is urgent. High‐performance liquid chromatography is an appropriate technology for this purpose, and the stationary phase is the kernel to the separation efficiency. In this study, flow‐through poly(styrene‐co‐divinylbenzene) microspheres characteristic of the binary pores, i.e. flow‐through pores and mesopores, were synthesized; this special porous structure would benefit the convective mass transfer while guarantee the high specific surface area. Owing to the hydrophobic nature, poly(styrene‐co‐divinylbenzene) microspheres were suitable as the reversed‐phase stationary phase for separation of proteins. For the high permeability of the poly(styrene‐co‐divinylbenzene) microspheres packed column, fast separation of the studied six proteins in ~2 min was achieved. The recoveries of studied proteins were acceptable in the range of 79.0–99.4%. The proposed column had good pH stability of 1–13 and repeatability. Moreover, the column was applied for egg white fast separation, further demonstrating its applicability for complex bio‐sample separation. The flow‐through poly(styrene‐co‐divinylbenzene) microspheres were promising for fast separation of large molecules.  相似文献   

10.
The introduction of a functional group into a poly(butyl acrylate) polymer prepared by copper‐mediated atom transfer radical polymerization and the characterization of the prepared polymer by gradient polymer elution chromatography are reported. The bromo end group of the initial polymer can be transformed into a different functional group with several functionalization reactions, including nucleophilic substitution and atom transfer radical addition (ATRA), in combination with comonomers, addition–fragmentation transfer agents, or stable radicals. Several new functionalization agents are reported, including ATRA using 1‐(3‐hydroxymethyl‐phenyl)‐pyrrole‐2,5‐dione and trimethyl{1‐[4‐(2‐trimethylsiloxyethoxy)]phenylethenyloxy}silane and nucleophilic substitution using 2‐mercapto ethanol. The rate constant of the functionalization reaction and the final functionality are determined with gradient polymer elution chromatography, a technique by which qualitative and quantitative information about the conversion can be obtained. Polymers with a functionality greater than 95% are reported. © 2002 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 40: 2350–2359, 2002  相似文献   

11.
Synthesis of novel amphiphilic biodegradable block copolymers based on ethylene carbonate is reported in this study. Polyethylene glycol monomethyl ether (MeO‐PEO) and polyethylene glycol (PEG) of varying molar masses are used as macro‐initiator for ring‐opening polymerization of ethylene carbonate in the presence of sodium stannate trihydrate as a heterogeneous transesterification catalyst. Earlier elution of block copolymer from macro‐initiator in size exclusion chromatography (SEC) indicated the successful synthesis of the block copolymers. Ratios of both types of blocks are varied systematically. Liquid chromatography at critical conditions is used for the analysis of the non‐critical individual blocks, and if there are any critical segments that are not attached to the non‐critical block. To the best of our knowledge, this is the first report on the synthesis of ethylene carbonate‐based amphiphilic block copolymers. Chromatographic critical conditions of the ethylene carbonate polymer are also reported for the first time. © 2017 Wiley Periodicals, Inc. J. Polym. Sci., Part A: Polym. Chem. 2017 , 55, 1887–1893  相似文献   

12.
The aggregation of poly(1,3‐cyclohexadiene) (PCHD), obtained by anionic polymerization with alkyllithium/amine systems, was examined using size exclusion chromatography (SEC) and size exclusion chromatography coupled with a multiangle laser light scattering photometer (SEC‐MALS). The PCHD polymer chain has a structure consisting of a main chain formed by 1,2‐addition (the 1,2‐CHD unit) and 1,4‐addition (the 1,4‐CHD unit). Mild stirring with relatively low temperature in the polymerization reaction forms an aggregation of PCHD. The molecular weight and molar ratio of 1,2‐CHD/1,4‐CHD units in the polymer chain strongly influence the aggregation of PCHD. In a high molecular weight PCHD, containing ~50% 1,2‐CHD units, an aggregation of the polymer was observed in tetrahydrofuran (THF) solution at room temperature. This aggregation of PCHD was soluble in 1,2,4‐trichlorobenzene (TCBz) and could be separated into each polymer molecule. In contrast, a polymer chain with a high content of 1,4‐CHD units having a relatively low cis‐stereospecificity was easily soluble in THF and TCBz without aggregating. A long polymer chain structure with a high content of 1,2‐CHD units is considered to be the reason for the generation of strong intermolecular forces contributing to the aggregation of PCHD with the solvophobic interactions. The degree of aggregation could be controlled by the conditions of the PCHD polymer solution. © 2006 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys 44: 1442–1452, 2006  相似文献   

13.
The grafting reaction of methyl methacrylate onto polybutadiene (PB) was investigated with different chromatographic techniques, including high‐performance liquid chromatography (HPLC) and online coupled two‐dimensional liquid chromatography. As a result of the grafting reaction, a complex mixture of nongrafted PB, the graft copolymer PB‐g‐PMMA [where PMMA is poly(methyl methacrylate)], and the PMMA homopolymer was formed. The complete separation of all the products of the grafting reaction was achieved with gradient HPLC. By the combination of gradient HPLC and size exclusion chromatography in a fully automated two‐dimensional chromatography setup, the complex distributions of the chemical composition and molar mass were fingerprinted simultaneously. © 2003 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 41: 3143–3148, 2003  相似文献   

14.
Two‐dimensional liquid chromatography largely increases the number of separated compounds in a single run, theoretically up to the product of the peaks separated in each dimension on the columns with different selectivities. On‐line coupling of a reversed‐phase column with an aqueous normal‐phase (hydrophilic interaction liquid chromatography) column yields orthogonal systems with high peak capacities. Fast on‐line two‐dimensional liquid chromatography needs a capillary or micro‐bore column providing low‐volume effluent fractions transferred to a short efficient second‐dimension column for separation at a high mobile phase flow rate. We prepared polymethacrylate zwitterionic monolithic micro‐columns in fused silica capillaries with structurally different dimethacrylate cross‐linkers. The columns provide dual retention mechanism (hydrophilic interaction and reversed‐phase). Setting the mobile phase composition allows adjusting the separation selectivity for various polar substance classes. Coupling on‐line an organic polymer monolithic capillary column in the first dimension with a short silica‐based monolithic column in the second dimension provides two‐dimensional liquid chromatography systems with high peak capacities. The silica monolithic C18 columns provide higher separation efficiency than the particle‐packed columns at the flow rates as high as 5 mL/min used in the second dimension. Decreasing the diameter of the silica monolithic columns allows using a higher flow rate at the maximum operation pressure and lower fraction volumes transferred from the first, hydrophilic interaction dimension, into the second, reversed‐phase mode, avoiding the mobile phase compatibility issues, improving the resolution, increasing the peak capacity, and the peak production rate.  相似文献   

15.
In this article we described our new approach to the polymer monolith with its morphology tailored for HPLC application to small solutes such as drug candidates. We prepared polymer monoliths based on glycerin 1,3‐dimethacrylate, GDMA with a bicontinuous structure by in situ photoinitiated free radical polymerization (UV irradiation at 365 nm). Our photopolymerization was carried out with a monodispese ultra high molecular weight polystyrene solution in chlorobenzene uniquely formulated as a porogen. The poly‐GDMA monoliths in bulk, rod and capillary thus prepared showed a bicontinuous network‐like structure featured by their fine skeletal thickness nearly in sub μm size. This monolithic structure was considered as a time‐evolved morphology frozen by UV‐irradiation via viscoelastic phase separation induced by the said porogenic polystyrene solution. According to our μHPLC measurement with acetophenone as a model solute, the UV prepared poly‐GDMA capillary demonstrated a much shaper elution profile affording higher column efficiency and permeability as compared with the thermally prepared capillary of the same bore size. Our investigation showed experimentally that poly‐GDMA monoliths with a well‐defined bicontinuous structure could be prepared reproducibly by photoinitiated radical polymerization via viscoelastic phase separation using the said unique porogen. © 2008 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 46: 4651–4673, 2008  相似文献   

16.
Polymerizations of higher α‐olefins, 1‐pentene, 1‐hexene, 1‐octene, and 1‐decene were carried out at 30 °C in toluene by using highly isospecific rac‐Me2Si(1‐C5H2‐2‐CH3‐4‐t Bu)2Zr(NMe2)2 (rac‐1) compound in the presence of Al(iBu)3/[CPh3][B(C6F5)4] as a cocatalyst formulation. Both the bulkiness of monomer and the lateral size of polymer influenced the activity of polymerization. The larger lateral of polymer chain opens the π‐ligand of active site wide and favors the insertion of monomer, while the large size of monomer inserts itself into polymer chain more difficultly due to the steric hindrance. Highly isotactic poly(α‐olefin)s of high molecular weight (MW) were produced. The MW decreased from polypropylene to poly(1‐hexene), and then increased from poly(1‐hexene) to poly(1‐decene). The isotacticity (as [mm] triad) of the polymer decreased with the increased lateral size in the order: poly(1‐pentene) > poly(1‐hexene) > poly(1‐octene) > poly(1‐decene). The similar dependence of the lateral size on the melting point of polymer was recorded by differential scanning calorimetry (DSC). 1H NMR analysis showed that vinylidene group resulting from β‐H elimination and saturated methyl groups resulting from chain transfer to cocatalyst are the main end groups of polymer chain. The vinylidene and internal double bonds are also identified by Raman spectroscopy. © 2000 John Wiley & Sons, Inc. J Polym Sci A: Polym Chem 38: 1687–1697, 2000  相似文献   

17.
Liquid chromatography at the critical condition (LCCC) is a high performance liquid chromatography (HPLC) technique that lies between size exclusion chromatography and adsorption-based interaction chromatography, where the elution of polymers becomes independent of polymer molecular weight. At LCCC, the balance between the entropic exclusion and the enthalpic adsorption interactions between polymers and stationary phases results in the simultaneous HPLC elution of polymers regardless of molecular weight. Using C18-bonded silica chromatographic columns with 5 μm particle size and different average pore size (diameter = 300 Å, 120 Å, 100 Å, and 50 Å), we report (1) the thermodynamic significance of LCCC conditions and (2) the influence of column pore size on the determination of critical conditions for linear polymer chains. Specifically, we used mixtures of monodisperse polystyrene samples ranging in molecular weight from 162 to 371,100 g/mol and controlled the temperature of the HPLC columns at a fixed composition of a mobile phase consisting of 57(v/v)% methylene chloride and 43(v/v)% acetonitrile. It was found that, at the fixed mobile phase composition, the temperature of LCCC (TLCCC) is higher for C18-bonded chromatographic columns with larger average pore size. © 2009 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys 47: 2533–2540, 2009  相似文献   

18.
The preparation of uniform polymers and their use in fundamental polymer chemistry are reviewed. A typical method of preparation is a combination of living polymerization and supercritical fluid chromatography separation. Synthetic uniform polymers allow us to solve ambiguous problems in polymer chemistry due to molecular weight distribution and are of significant importance for studies on structure–property relationships. A close inspection of an isotactic uniform chloral oligomer with a symmetrical chemical structure reveals that oligomers are the first examples of stable atropisomers of aldehyde oligomers and that their chiroptical properties are due only to their helical geometries. A molecular-level understanding of the mechanism and stoichiometry of the association process of polymer molecules is possible only with uniform polymers, and stereocomplex formation between isotactic and syndiotactic poly(methyl methacrylate)s in acetone has vigorously been studied by size exclusion chromatography (SEC) and NMR. End-functionalized uniform polymers have enabled us to prepare uniform polymer architectures, such as block, graft, comb, and star polymers. A uniform stereoblock poly(methyl methacrylate) with an isotactic (methyl methacrylate)46-syndiotactic (methyl methacrylate)46 structure shows a single SEC peak in chloroform but three peaks in acetone, which are ascribable to intermolecularly and intramolecularly associated complexes and nonassociated molecules. A three-arm star polymer with one isotactic chain and two syndiotactic chains shows a peculiar SEC behavior in acetone due to a braid type of intramolecular stereocomplex formation. © 2003 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 42: 416–431, 2004  相似文献   

19.
In this work, monolithic silica columns with the C4, C8, and C18 chemistry and having various macropore diameters and two different mesopore diameters are studied to access the differences in the column efficiency under isocratic elution conditions and the resolution of selected peptide pairs under reversed-phase gradient elution conditions for the separation of peptides and proteins. The columns with the pore structural characteristics that provided the most efficient separations are then employed to optimize the conditions of a gradient separation of a model mixture of peptides and proteins based on surface chemistry, gradient time, volumetric flow rate, and acetonitrile concentration. Both the mesopore and macropore diameters of the monolithic column are decisive for the column efficiency. As the diameter of the through-pores decreases, the column efficiency increases. The large set of mesopores studied with a nominal diameter of approximately 25 nm provided the most efficient column performance. The efficiency of the monolithic silica columns increase with decreasing n-alkyl chain length in the sequence of C18相似文献   

20.
The crystallization of isotactic poly(4‐methylpentene‐1) in its stable tetragonal crystal modification based on the 72 helix conformation was achieved on three different low molecular weight organic substrates and on polytetrafluoroethylene. The contact face was always the (100) face, although the details of the epitaxial relationships generated one, two, or even three chain axis orientations in the polymer epitaxial overgrowth. © 2000 John Wiley & Sons, Inc. J Polym Sci B: Polym Phys 38: 3088–3097, 2000  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号