首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Two new Ag(I) chemically modified carbon paste electrodes were prepared with comparative potentiometric study of 1,3,6,10,13-pentaaza-2,14-(2,6-pyridyl)-cyclotetradecane-4,12-dione (PPCT) and 1,3,6,9,11,12-pentaaza-2,13-(2,6-pyridyle)-bicycle[2,2,9]pentadecane-4,11-dione (PPBP) as ionophore. These sensors have been modified with sol–gel–Au nanoparticles to obtain a wide concentration range for potentiometric determination of Ag(I) in aqueous solutions. The sensors exhibit significantly enhanced selectivity toward Ag(I) ions over a wide concentration range of 4.0 × 10?9–2.2 × 10?2 and 2.2 × 10?7–2.0 × 10?2 mol L?1 with a lower detection limit of 2.5 × 10?9 and 2.0 × 10?7 mol L?1 for PPCT and PPBP modified electrodes respectively. The electrodes are highly selective to Ag(I) ions over a large number of mono, bi, and tri-valent cations. These electrodes were successfully used as indicator electrode for potentiometric determination of silver in sulphadiazine (burning cream) and radiological film.  相似文献   

2.
《Analytical letters》2012,45(7):1144-1157
Abstract

The fabrication and analytical applications of two types of potentiometric sensors for the determination of ketoconazole (KET) are described. The sensors are based on the use of KET-molybdophosphoric acid (MPA) ion pair as electroactive material. The fabricated sensors include both polymer membrane and carbon paste electrodes. Both sensors showed a linear, stable and near Nernstian slope of 57.8 mV/decade and 55.2 mV/decade for PVC membrane and carbon paste sensors respectively over a relatively wide range of KET concentration (1 × 10?2 ? 5 × 10?5and 1 × 10?2 ? 1 × 10?6). The sensors showed a fast response time of < 30 sec and < 45 sec. A useful pH range of 3–6 was obtained for both types of sensors. A detection limit of 2.96 × 10?5M was obtained for PVC membrane sensor and 6.91 × 10?6 M was obtained for carbon paste sensor. The proposed sensors proved to have a good selectivity for KET with respect to a large number of ions. The proposed sensors were successfully applied for the determination of KET in pharmaceutical formulations. The results obtained are in good agreement with the values obtained by the standard method.  相似文献   

3.
A simple, rapid and a highly selective method for direct electrochemical determination of acebutolol hydrochloride (AC) was developed. The developed method was based on the construction of three types of sensors conventional polymer (I), carbon paste (II) and modified carbon nanotubes (MCNTs) carbon paste (III). The fabricated sensors depend mainly on the incorporation of acebutolol hydrochloride with phosphotungstic acid (PTA) forming ion exchange acebutolol‐phosphotungstate (AC‐PT). The performance characteristics of the proposed sensors were studied. The sensors exhibited Nernstian responses (55.6 ± 0.5, 57.14 ± 0.2 and 58.6 ± 0.4 mV mol L?1) at 25 °C over drug concentration ranges (1.0 × 10?6‐1.0 × 10?2, 1.0 × 10?7‐1.0 × 10?2 and 5.0 × 10?8‐1.0 × 10?2 mol L?1 with lower detection limits of (5.0 × 10?7, 5.0 × 10?8 and 2.5 × 10?8 mol L?1 for sensors (I), (II) and (III), respectively. The influence of common and possible interfering species, pharmaceutical additives and some related pharmacological action drugs was investigated using separate solution method and no interference was found. The stability indicating using forced degradation of acebutolol hydrochloride was studied. The standard addition method was used for determination of the investigated drug in its pharmaceutical dosage forms and biological fluids. The results were validated and statistically analysed and compared with those from previously reported methods.  相似文献   

4.
Potentiometric sensors are proposed on the basis of alkyl sulfates and cationic copper(II) complexes with organic reagents selective to anionic surfactants. Physical and chemical properties of the ionophores (composition, thermal stability, solubility) are determined in aqueous solutions and in the membrane phase. The studied compounds are poorly soluble (K s = n × 10–22n × 10–20) and thermally stable at 80?90°C. The main electroanalytical properties of sensors are estimated, i.e., analytical range in solutions of sodium alkyl sulfates 2 × 10–7–1 × 10–2 M; 46 <α < 66 mV/рc; LOD = 1 × 10–7 M; response time 8–9 s in a solution of sodium dodecyl sulfate with the concentration not lower than 1 × 10–4 M; potential drift 2–3 mV/day; and lifetime 12 months. The multisensor determination of homologues sodium alkyl sulfates in model mixtures and natural waters is performed using the proposed sensors.  相似文献   

5.
Since to the best of our knowledge, there is no potentiometric sensors based on carbon paste electrodes were proposed for the potentiometric determination of molybdenum(VI) ion. In this study, 2,2′-(propane-1,3-diylbis(oxy))dibenzoic acid (PBODBA) was synthesized and used as modifier in the fabrication of carbon paste electrode (CPE) for the quantification of molybdenum(VI). The developed electrodes I and II showed hexavalent Nernstian response of 9.80±0.05 and 9.90±0.08 mV decade−1 over the concentration ranges of 1.0×10−7–1.0×10−3 and 1.0×10−8–1.0×10−3 mol L−1, respectively. The electrodes showed good selectivity for Mo(VI). The modified electrodes were applied for the determination of Mo(VI) concentration in masscuaje agricultural fertilizer and spiked juice extractions containing several metals.  相似文献   

6.
Three simple, rapid, and sensitive ion-selective electrodes for indirect determination of free formaldehyde in urea glue and wastewater have been developed. The methods are based on the formation of the membrane sensors 2,4-dinitrophenylhydrazine-phosphtungestic acid (DNPH-PTA), 2,4-dinitrophenylhydrazine-phosphomolybdic acid (DNPH-PMA), and 2,4-dinitrophenylhydrazine-tetraphenylborate (DNPH-TPB) as neutral carriers. The sensors are stable and show fast potential responses of 30?s, and near-Nernstian cationic slopes of 56.2?±?0.5, 54.3?±?0.5, and 53.8?±?0.4?mV per decade of activity between pH 0.5 and 3.5 over a wide range of 2,4-dinitrophenylhydrazine concentrations (1?×?10?5 to 1?×?10?2?M). These sensors were used for indirect determination of formaldehyde over concentration range (1?×?10?4 to 1?×?10?1?M). The selectivity coefficients of the developed sensors indicate excellent selectivity for 2,4 DNPH over a large number of organic and inorganic species. The mediator o-nitrophenyloctyl ether has a significant affect on the lifetime of the fabricated sensors. The analytical applications of the proposed sensors showed good results for indirect determination of formaldehyde in formaldehyde solutions, wastewater solutions, and free formaldehyde in urea-formaldehyde liquid and powder glues. The results were compared favourably with that obtained by ASTM, colorimetric, and British Standard methods.  相似文献   

7.
《Electroanalysis》2017,29(2):566-577
Two novel carbon paste electrodes based on gentamicin‐reineckate (GNS‐RN)/multiwall carbon nanotubes (MWCNTs)/sodium tetraphenyl borate (NaTPB) or potassium tetraphenylborate (KTPB) for potentiometric determination of gentamicin sulfate were constructed. Our endeavors of lowering the detection limit for gentamicin ion‐selective electrodes were described. The paper focused on gentamicin carbon paste electrodes based on GNS‐RN as electroactive material, o ‐nitrophenyloctyl ether (o ‐NPOE) as plasticizer and incorporation of MWCNTs and lipophilic anionic additives (NaTPB and KTPB) which lower the detection limit of the electrodes showing best results for determination of gentamicin ion. The characteristics of the electrodes, GNS‐RN+NaTPB+MWCNTs (sensor 1) and GNS‐RN+KTPB+ MWCNTs (sensor 2), were measured, showing favorable features as they provided measurements of the potential with near‐Nernstian slopes of 29.6±0.3 and 29.1±0.3 mV/decade over the concentration range of 1.0×10−6–1.0×10−2 mol L−1 and pH ranges 3.0–8.2 and 3.0–8.0 in short response times (6.5 sec). Importantly, the electrodes had low detection limits of 3.0×10−7and 3.4×10−7 mol L−1 for the two sensors, respectively. The sensors showed high selectivity for gentamicin ion with respect to a large number of interfering species. The electrodes were successfully applied for the potentiometric determination of GNS ions in pure state, pharmaceutical preparations and human urine with high accuracy and precision. The results of this study were compared with some previously published data using other analytical methods.  相似文献   

8.
A cobalt oxide nanoparticles (Co3O4NPs) and multi walled carbon nanotubes (MWCNTs) modified carbon paste electrodes were used to study the electrochemical behavior of linagliptin and empagliflozin in Britton Robinson buffer solution of pH 8.0 using cyclic and square wave voltammetry. The above mentioned modified electrodes showed highly sensitive sensing and gave an excellent anodic response for both drugs. The peak current varied linearly over the concentration ranges: 3.98×10?5–1.53×10?3 mol L?1 (18.82–723.00 μg/mL) and 7.94×10?6–1.07×10?4 mol L?1 (3.65–48.25 μg/mL) with determination coefficients of 0.9999 and 0.9998 for linagliptin and empagliflozin, respectively. The recoveries and relative standard deviations were found in the following ranges: 98.80 %–102.00 % and 0.23 %–1.90 % for linagliptin and 98.30 %–101.80 % and 0.11 %–1.86 % for empagliflozin. The detection and quantification limits were 1.13×10?5 and 3.76×10?5 mol L?1 (5.34and17.77 μg/mL) for linagliptin, 1.71×10?6and 5.68×10?6 mol L?1 (0.77 and 2.56 μg/mL) for empagliflozin. The proposed sensors have been successfully applied for the determination of the drugs in bulk, pharmaceutical formulations and biological fluids.  相似文献   

9.
Two sensitive and selective potentiometric sensors based on zinc-iron layered double hydroxides/multiwalled carbon nanotubes (Zn−Fe LDH/MWCNTs) (sensor I) and graphene/multiwalled carbon nanotubes (Gr/MWCNTs) (sensor II) nanocomposites were developed for benzydamine hydrochloride (Benz) determination. The investigated sensors displayed excellent Nernstian slopes 58.5±0.7 and 59.5±0.5 mV decade−1, detection limits 8.3×10−7 and 1.9×10−7 mol L−1, long lifetimes, adequate selectivity, high chemical, and thermal stability within pH range of 2.4–8.5 for sensors І and ІІ, respectively. The surface morphology of sensors was analyzed using a Transmission Electron Microscope (TEM). The analytical method was efficiently implemented for Benz determination in biological fluids and surface water samples.  相似文献   

10.
Modified screen printed (SPE) and carbon paste electrodes (CPE) with phenanthroline–tetraphenyl borate ionophore [Phen:TPB] were fabricated for the determination of copper(II). The modified electrodes have linear responses over a wide concentration range (1 × 10?6–1 × 10?2 mol·L?1) of copper(II) ion at 25 °C with divalent cationic slopes of 29.85 ± 0.58 and 29.45 ± 0.81 mV·decade?1 and exhibit a detection limit of 1 × 10?6 mol·L?1 for SPE and CPE. The selectivity coefficient was measured using the match potential method in acetate buffer of pH = 4.2. The modified SPE and CPE sensors show high selectivity and sensitivity for determination of copper(II) and also show stable and reproducible response over a period of five and three months for SPE and CPE sensors, respectively. This method can be used for determination of copper(II) in water, soil, plant and fish tissue samples and the results obtained agreed with those obtained with atomic absorption spectrometer (AAS).  相似文献   

11.
Amr L. Saber 《Electroanalysis》2010,22(24):2997-3002
Simple, selective and accurate sensors were developed for the determination of melatonin and oxomemazine in biological samples (urine) and in pharmaceutical preparations. Potentiometric measurements were based on bismus tetraiodate‐drug ion‐pair as novel electroactive materials incorporating a plasticized PVC membrane with o‐nitrophenyl octyl ether or dioctyl phthalate. Each sensor was conditioned for at least two days in 0.1 M drug solution before use. It exhibited fast and stable Nernstian response for melatonin and oxomemazine over the concentration range of 1.0×10?6–1.0×10?2 M and 1.0×10?5–1.0×10?2 M, pH range of 3.0–6.5 and 3.5–6.0 for melatonin and oxomemazine sensors, respectively. Results with an average recovery not more than 101 % and a mean standard deviation less than 1.0 % of the nominal were obtained for the four sensors. The sensors showed reasonable selectivity towards investigated drugs in presence of many cations.  相似文献   

12.

Background

The construction and electrochemical response characteristics of Poly (vinyl chloride) membrane sensors for moxifloxacin HCl (MOX) are described. The sensing membranes incorporate ion association complexes of moxifloxacin cation and sodium tetraphenyl borate (NaTPB) (sensor 1), phosphomolybdic acid (PMA) (sensor 2) or phosphotungstic acid (PTA) (sensor 3) as electroactive materials.

Results

The sensors display a fast, stable and near-Nernstian response over a relative wide moxifloxacin concentration range (1 × 10-2 - 4.0 × 10-6, 1 × 10-2 - 5.0 × 10-6, 1 × 10-2 - 5.0 × 10-6 M), with detection limits of 3 × 10-6, 4 × 10-6 and 4.0 × 10-6 M for sensor 1, 2 and 3, respectively over a pH range of 6.0 - 9.0. The sensors show good discrimination of moxifloxacin from several inorganic and organic compounds. The direct determination of 400 μg/ml of moxifloxacin show an average recovery of 98.5, 99.1 and 98.6% and a mean relative standard deviation of 1.8, 1.6 and 1.8% for sensors 1, 2 and 3 respectively.

Conclusions

The proposed sensors have been applied for direct determination of moxifloxacin in some pharmaceutical preparations. The results obtained by determination of moxifloxacin in tablets using the proposed sensors are comparable favorably with those obtained using the US Pharmacopeia method. The sensors have been used as indicator electrodes for potentiometric titration of moxifloxacin.
  相似文献   

13.
《Electroanalysis》2005,17(24):2246-2253
Coated‐wire (CW) and tubular (Tu) type membrane sensors for creatinine are developed. These consist of creatinine tungstophosphate(CTP), creatinine molybdophosphate (CMP) and creatinine picrolonate (CPC) ion‐pair complexes as electroactive materials dispersed in plasticized poly(vinyl chloride) matrix membranes. Electrochemical evaluation of these sensors under static (batch) mode of operation reveals near‐Nernstian response with slopes of 62.9, 58.1, and 55.2 mV decade?1 over the concentration range 1×10?2–5.0×10?6, 1×10?2–7.5×10?5, and 1×10?2?3.1×10?5 mol L?1. The lower detection limits are 0.39, 3.49, and 2.20 μg mL?1 creatinine with CTP, CMP and CPC membrane based sensors plasticized with o‐NPOE, respectively. Tubular and coated wire CTP membrane sensors are incorporated in flow‐through cells and used as detectors for flow injection analysis (FIA) of creatinine. The intrinsic characteristics of the detectors under hydrodynamic mode of operation in a low dispersion manifold are determined and compared with data obtained under static mode of operation. With 10?2 mol L?1 phosphate buffer of pH 4.5 as a carrier solution, the tubular and coated wire CTP detectors exhibit rapid response of 58.9 and 50.7 mV decade?1 over the concentration range 1×10?2–1×10?5 mol L?1 and detection limits of 0.39 μg mL?1 and 0.85 μg mL?1, respectively. Validation of the assay methods with the proposed sensors by measuring the lower detection limit, range, accuracy, precision, repeatability and between‐day‐variability reveals good performance characteristics confirming applicability for continuous determination of creatinine. The sensors are used for determining creatinine in human blood serum at an input rate of 40 samples per hour. No interferences are caused by creatine, most common anions, cations and organic species normally present in biological fluids. The results favorably compare with data obtained using the standard spectrophotometric method.  相似文献   

14.
The use of hyperbranched polyesterpolyols of different generations favors firmer fixation of carbon nanotubes and silver nanoparticles as components of composite materials on the electrode surface (0.028 mg cm–2), which improves the operation characteristics of monoamine oxidase biosensors. The size of silver nanoparticles (18–52 nm) depends on the conditions for preparing hyperbranched polyesterpolyols, and their use as electrode modifiers influences the analytical possibilities of amperometric biosensors. Silver nanoparticles (18 nm, data of atomic force microscopy) in polyesterpolyols of third generation (pH 10.0) as components of the developed biosensors extend the interval of determinable concentrations to 1 × 10–4–1 × 10–8 M and decrease the lower limit of determination to 3 × 10–9 M, compared to the unmodified sensors, owing to enhancement of the analytical signal. The developed biosensors were tested in monitoring of drugs (antidepressants) in Coaxil and Auroriks drug forms with the relative standard deviation on the level of 0.052.  相似文献   

15.
A method for the analysis of the thiocholine concentration, as well as the activity of the butyrylcholinesterase (BChE) enzyme and its inhibitors, using thiol-sensitive planar sensors has been proposed. Thiocholine sensitivity of the sensors was achieved by a mediator layer of manganese dioxide formed on a working carbon electrode. The detection limits for BChE and its inhibitor diazinon were 1 × 10?10 M and 1 × 10?9 M, respectively. The approach that was developed simplifies the analysis of inhibitors. It could be used for water quality and environmental monitoring.  相似文献   

16.
Miniaturized potentiometric membrane sensors for quinine incorporated with molecular imprinted polymer (MIP) were synthesized and implemented. Planar PVC based polymeric membrane sensors containing quinine‐methacrylic and/or acrylic acid‐ethylene glycol methacrylate were dispensed into anisotropically etched wells on polyimide wafers. The determination of quinine was carried out in acidic solution at pH 6, where positively charged species predominated prevalently. The suggested miniaturized planner sensors exhibited marked selectivity, sensitivity, long‐term stability and reproducibility. At their optimum conditions, the sensors displayed wide concentration ranges of 4.0×10?6–1.0×10?2mol L?1 and 1.0×10?5–1.0×10?2 mol L?1 with slopes of about 61.3–55.7 mV decade?1; respectively. Sensors exhibit detection limits of 1.2×10?6 and 8.2×10?6 mol L?1 upon the use of methacrylic and acrylic acid monomers in the imprinted polymer, respectively. Validation of the assay method according to the quality assurance standards (range, within‐day repeatability, between‐day variability, standard deviation, accuracy, and good performance characteristics) which could assure good reliable novel sensors for quinine estimation was justified. Application of the proposed flow‐through assay method for routine determination of quinine in soft drinks was assayed and the results compared favorably with data obtained by the standard fluorimetric method.  相似文献   

17.
The voltammetric behavior of 3‐nitrofluoranthene and 3‐aminofluoranthene was investigated in mixed methanol‐water solutions by differential pulse voltammetry (DPV) at boron doped diamond thin‐film electrode (BDDE). Optimum conditions have been found for determination of 3‐nitrofluoranthene in the concentration range of 2×10?8–1×10?6 mol L?1, and for determination 3‐aminofluorathnene in the concentration range of 2×10?7–1×10?5 mol L?1, respectively. Limits of determination were 3×10?8 mol L?1 (3‐nitrofluoranthene) and 2×10?7 mol L?1 (3‐aminofluoranthene).  相似文献   

18.
《Electroanalysis》2004,16(12):1002-1008
Preliminary theoretical studies revealed the selective complexation of bis (2‐mercaptoanil) diacetyl (BMDA) with La3+ over several alkali, alkaline earth and heavy metal ions. Thus, novel PVC‐based membrane (PBM) and coated graphite membrane (CGM) sensors for La(III) based on BMDA were prepared. The electrodes display Nernstian behavior over wide concentration ranges (i.e., 1.0×10?5–1.0×10?1 M for PBM and 1.0×10?6–1.0×10?1 M for CGM). The potential response of sensors was pH independent in the range of 4.0–8.0. The sensors possess satisfactory reproducibility, fast response time (<15 s), and specially excellent discriminating ability for La3+ ions with respect to most of the cations. The membrane sensor was used as an indicator electrode in potentiometric titration of lanthanum ions with EDTA. The coated graphite membrane electrode was applied in determination of fluoride ions in mouth wash preparations.  相似文献   

19.
Molecularly imprinted polymers (MIP) were used as potentiometric sensors for the selective recognition and determination of chlormequat (CMQ). They were produced after radical polymerization of 4‐vinyl pyridine (4‐VP) or methacrylic acid (MAA) monomers in the presence of a cross‐linker. CMQ was used as template. Similar non‐imprinted (NI) polymers (NIP) were produced by removing the template from reaction media. The effect of kind and amount of MIP or NIP sensors on the potentiometric behavior was investigated. Main analytical features were evaluated in steady and flow modes of operation. The sensor MIP/4‐VP exhibited the best performance, presenting fast near‐Nernstian response for CMQ over the concentration range 6.2×10−6–1.0×10−2 mol L−1 with detection limits of 4.1×10−6 mol L−1. The sensor was independent from the pH of test solutions in the range 5–10. Potentiometric selectivity coefficients of the proposed sensors were evaluated over several inorganic and organic cations. Results pointed out a good selectivity to CMQ. The sensor was applied to the potentiometric determination of CMQ in commercial phytopharmaceuticals and spiked water samples. Recoveries ranged 96 to 108.5%.  相似文献   

20.
《Electroanalysis》2004,16(10):860-865
The electrocatalytic oxidation of sulfite has been studied on the cobalt pentacyanonitrosylferrate modified glassy carbon electrode (CoPCNF). The CoPCNF films on the glassy carbon electrodes show an excellent electrocatalytic activity toward the oxidation of sulfite in 0.5 M KNO3. The kinetics of the catalytic reaction was investigated by using cyclic voltammetry, rotating disk electrode (RDE) voltammetry and chronoamperometry. The average value of the rate constant, K, for the catalytic reaction and the diffusion coefficient, D, were evaluated by different approaches for sulfite and found to be 2.9×102 M?1s?1 and 4.6×10?6 cm2s?1, respectively. At a fixed potential under hydrodynamic conditions (stirred solutions), the oxidation current is proportional to the sulfite concentration and the calibration plot was linear over the concentration range 5×10?6–1×10?4 M. The detection limit of the method is 3×10?6 M., low enough for the trace sulfite determination.  相似文献   