共查询到20条相似文献,搜索用时 15 毫秒
1.
流动注射化学发光法测定盐酸美司坦 总被引:1,自引:0,他引:1
在碱性介质中,当把鲁米诺和KMnO4的混合溶液注入到盐酸美司坦溶液中时,会产生很强的化学发光现象。由此结合流动注射技术,建立了测定盐酸美司坦的流动注射化学发光新方法。该法的线性范围为2.0×10^-7-8.0×10^-6g/mL,检出限(3σ)为9×10^-8g/mL,对2.0×10^-6g/mL盐酸美司坦样品连续进行11次平行测定,其RSD为0.74%。已用于盐酸美司坦片剂中盐酸美司坦的测定。 相似文献
2.
在酸性介质中,木犀草素在KMnO4-HCHO体系中产生化学发光,据此建立了一种简便、快速测定木犀草素的化学发光新方法。化学发光强度与木犀草素的浓度在5.0×10-8~1.5×10-5g/mL范围内呈现出良好的线性关系。其检测限(3σ)为3.0×10-8g/mL,对8.0×10-7g/mL的木犀草素溶液进行11次平行测定,相对标准偏差为2.8%。方法可应用于实际样品和合成样品中木犀草素的测定。并探讨了反应的机理。 相似文献
3.
流动注射化学发光抑制法测定维生素E 总被引:4,自引:0,他引:4
实验发现,H2SO4-KMnO4-甲醛在丙酮存在下发光信号大大增强,据此建立了H2SO4-KMnO4-甲醛-丙酮新体系。同时发现维生素E(VE)对H2SO4-KMnO4-甲醛-丙酮化学发光体系有强烈的抑制作用,建立了维生素E的流动注射化学发光抑制法的新体系。化学发光信号的降低值与VE的浓度在1.0×10-5~1.0×10-3mol/L的范围内呈良好的线性关系,方法的检出限为3.0×10-6mol/L。对1.0×10-4mol/L的VE进行11次平行测定,其相对标准偏差为1.5%。该法已用于VE片剂中VE的测定。 相似文献
4.
5.
A new method is proposed for the determination of phenylephrine hydrochloride by flow injection analysis with direct chemiluminescence detection. The method is based on the oxidation of the drug by potassium permanganate in sulfuric acid medium at 80 degrees C. The calibration graph is linear over the range 0.03-8 ppm phenylephrine hydrochloride, with a relative standard deviation (n = 51, 0.5 ppm) of 1.1% and sample throughput of 134/h. The influence of 38 different foreign compounds was tested, and the method was applied to the determination of phenylephrine hydrochloride in 8 different pharmaceutical formulations. 相似文献
6.
7.
8.
H2SO4酸性条件下,甲醛对KMnO4-盐酸萘甲唑林(盐酸氧甲唑林)化学发光体系有较强的增敏作用,且强度与药物浓度呈良好的线性关系.据此,建立了采用KMnO4-甲醛体系测定制剂中盐酸萘甲唑林(盐酸氧甲唑林)的流动注射-化学发光分析法.在优化的实验条件下,盐酸萘甲唑林在1.0×10-8~7.0×10-6g/mL范围内呈良好的线性关系,检出限为8.69×10-9g/mL;盐酸氧甲唑林在5.0×10-8~1.0×10-5范围内呈线性关系,检出限为3.47×10-8g/mL.对浓度为1.0×10-6g/mL的盐酸萘甲唑林和盐酸氧甲唑林分别进行的11次平行测定,RSD分别为4.0%和4.1%. 相似文献
9.
10.
11.
在酸性条件下,KMnO4与甲醛能够产生微弱的化学发光,而富马酸依美斯汀的存在能够大大增强该化学发光强度;结合流动注射技术,建立了测定富马酸依美斯汀的流动注射-化学发光新方法。该方法的线性范围分别为3.0×10-8~2.0×10-7g/mL,2.0×10-7~1.0×10-6g/mL和1.0×10-6~8.0×10-6g/mL。检出限为1.0×10-8g/mL,对2.0×10-6g/mL富马酸依美斯汀滴眼液平行测定11次,其相对标准偏差为1.3%。该方法已成功应用于滴眼液中富马酸依美斯汀的含量测定。 相似文献
12.
Tetracycline hydrochloride (4 × 10?5?1 × 10?3M) in a 40-μl aqueous sample is determined in a flow system by measurement of the chemiluminescence emitted on reaction with bromine (9.3 × 10?3 M) at pH 10.4 (carbonate buffer). The limit of detection is 1.6 nmol per 40-μl injection. 相似文献
13.
流动注射化学发光法测定青霉素G钾 总被引:1,自引:0,他引:1
在甲醛的存在下,酸性KMnO4与青霉素G钾能够产生很强的化学发光,从而建立了KMnO4-甲醛-青霉素G钾化学发光体系来测定青霉素G钾.青霉素G钾的测定线性范围为2.0×10-7~1.0×10-5 g/mL,方法的检出限为1.4×10-7 g/mL,对4.0×10-7 g/mL的青霉素G钾进行11次平行测定,相对标准偏差为1.0%,用此法测定青霉素G钾取得了较好的结果. 相似文献
14.
A fast and simple method for the determination of procaine hydrochloride by ion-pairing flow injection analysis has been developed. It is based on the formation of an ion-pair with sodium dodecyl phenylsulphonate and piezoelectric detection. The calibration curve was linear between 0.02 and 2.00 mg/mL, with a detection limit of 0.01 mg/mL, a relative standard deviation of 0.3% (10 replicates) and a sampling frequency of 120/h. The proposed method has been satisfactorily applied to the determination of procaine hydrochloride in pharmaceutical preparations. 相似文献
15.
Z. Mo J. Luo Xiaohui Long Ziling Xia 《Fresenius' Journal of Analytical Chemistry》1997,358(4):556-558
A fast and simple method for the determination of procaine hydrochloride by ion-pairing flow injection analysis has been
developed. It is based on the formation of an ion-pair with sodium dodecyl phenylsulphonate and piezoelectric detection. The
calibration curve was linear between 0.02 and 2.00 mg/mL, with a detection limit of 0.01 mg/mL, a relative standard deviation
of 0.3% (10 replicates) and a sampling frequency of 120/h. The proposed method has been satisfactorily applied to the determination
of procaine hydrochloride in pharmaceutical preparations.
Received: 19 August 1996 / Revised: 6 November 1996 / Accepted: 12 December 1996 相似文献
16.
17.
流动注射-化学发光法测定亚甲蓝 总被引:1,自引:0,他引:1
鲁米诺在碱性条件下,可以被高锰酸钾氧化产生化学发光,亚甲蓝能显著增强该化学发光。基于这点,结合流动注射技术建立了测定亚甲蓝的化学发光新方法。在优化的实验条件下,测定亚甲蓝的线性范围为1.0×10-7~5.0×10-5mol/L,检出限为3.9×10-8mol/L,对1.0×10-5mol/L亚甲蓝进行9次平行测定,其相对标准偏差为1.0%。方法已用于注射液中亚甲蓝的测定。 相似文献
18.
Amir Waseem Mohammad Yaqoob Masood Ahmed Siddiqui 《International journal of environmental analytical chemistry》2013,93(12):825-832
A flow-injection procedure is described for the determination of carbaryl based on its inhibition effect on luminol-cobalt(II) chemiluminescence reaction in alkaline medium in the presence of hydrogen peroxide. The calibration data over the range 5.0?×?10?7 to 20?×?10?6?M give a correlation coefficient (r 2) of 0.9972 with relative standard deviations (RSD; n?=?4) in the range of 1.0–2.1% with a limit of detection (3?×?blank noise) of 2.37?×?10?7?M for carbaryl. The sample throughput was 120?h?1. The effects of some carbamates, anions, and cations were studied on luminol CL system for carbaryl determination. The proposed method has been applied to determine carbaryl in natural waters. 相似文献
19.
流动注射化学发光法测定DL-酪氨酸 总被引:6,自引:1,他引:6
在甲醛存在下 ,高锰酸钾与DL 酪氨酸能够发生化学发光反应 ,产生很强的化学发光。据此采用流动注射技术 ,建立了一种测定DL 酪氨酸的化学发光分析法。方法的检出限为 2 .9× 1 0 - 8g/mL ,相对标准偏差为 1 .5 % ( 1 .0× 1 0 - 6g/mLDL 酪氨酸 ,n =1 1 ) ,线性范围为 1 .0× 1 0 - 7g/mL~ 5 .0× 1 0 - 6g/mL。 相似文献