The performance of two recently developed heteronuclear decoupling schemes designed to quench rotary resonance, phase-inverted supercycled sequence for attenuation of rotary resonance (PISSARRO) and high-phase two-pulse phase modulation (high-phase TPPM), are probed at high spinning frequencies. High-phase TPPM may be useful at the n=1 rotary resonance condition while PISSARRO permits efficient decoupling over a broad commonly used range of rf amplitudes, even at very high spinning frequencies. New insights into the response of spin systems to both decoupling schemes have been gained. High-phase TPPM is sensitive to the offsets of remote protons, their chemical shift anisotropies, and the relative orientations of the heteronuclear dipolar and proton chemical shift tensors. Since PISSARRO is virtually immune against such effects, the method is especially suited for very high magnetic fields.  相似文献   

2.
Aiming to improve heteronuclear spin decoupling efficiency in NMR spectroscopy of solids and liquid crystals, we have modified the original Small Phase Incremental ALteration (SPINAL) sequence by incorporating a frequency sweep into it. For the resulting sequence, termed SWf-SPINAL, the decoupling performance of a large number of sweep variants was explored by both numerical simulations and NMR experiments. It is found that introducing a frequency sweep generally increases both the ‘on-resonance’ decoupling performance and the robustness towards parameter offsets compared to the original SPINAL sequence. This validates the concept of extending the range of efficient decoupling by introducing frequency sweeps, which was recently suggested in the context of the frequency-swept SWf-TPPM method. The sequence found to be best performing among the SWf-SPINAL variants consists of fully swept 16 pulse pairs and is designated (32)-SPINAL-32. Its good decoupling performance for rigid spin systems is confirmed by numerical simulations and also experimentally, by evaluating the CH2 resonance of a powder sample of l-tyrosine under MAS. For moderate MAS frequencies, the new sequence matches the decoupling achieved with SWf-TPPM, and outperforms all other tested sequences, including TPPM and SPINAL-64. (32)-SPINAL-32 also shows excellent decoupling characteristics for liquid crystalline systems, as exemplified by experiments on the 5CB liquid crystal.  相似文献   

3.
The design of variants of the swept-frequency two-pulse phase modulation sequence for heteronuclear dipolar decoupling in solid-state NMR is reported, their performance evaluated, and compared with other established sequences like TPPM and SPINAL. Simulations performed to probe the role of the homonuclear (1)H-(1)H bath show that the robustness of the decoupling schemes improves with the size of the bath. In addition, these simulations reveal that the homonuclear (1)H-(1)H bath also leads to broad baselines at high MAS rates. Results from a study of the SPINAL decoupling scheme indicate that optimisation of the starting phase and phase increment improves its performance and efficiency at high MAS rates. Additionally, experiments performed on a liquid crystal display the role of the initial phase in SPINAL-64 and sequences in the SW(f)-TPPM family.  相似文献   

4.
Recently we introduced a radiofrequency pulse scheme for heteronuclear dipolar decoupling in solid-state nuclear magnetic resonance under magic-angle spinning [R.S. Thakur, N.D. Kurur, P.K. Madhu, Swept-frequency two-pulse phase modulation for heteronuclear dipolar decoupling in solid-state NMR, Chem. Phys. Lett. 426 (2006) 459-463]. Variants of this sequence, swept-frequency TPPM, employing frequency modulation of different types have been further tested to improve the efficiency of heteronuclear dipolar decoupling. Among these, certain sequences that were found to perform well at lower spinning speeds are demonstrated here on a liquid-crystal sample of MBBA for application in static samples. The new sequences are compared with the standard TPPM and SPINAL schemes and are shown to perform better than them. These modulated schemes perform well at low decoupler radiofrequency power levels and are easy to implement on standard spectrometers.  相似文献   

5.
We describe a simple yet highly effective optimization strategy for SPINAL-64 1H decoupling conditions for magic-angle spinning solid-state NMR. With adjustment of the phase angles in a coupled manner, the optimal conditions resulting from three parameter optimizations can be determined with adjustment of a single phase. Notably, echo T? relaxation times for 13C and 1?N show significant enhancement (up to 64%), relative to the previous described SPINAL-64 conditions, under the moderate 1H decoupling levels (60-100 kHz) and MAS rate (13.3 kHz) commonly employed for high-resolution SSNMR spectroscopy of proteins. Additionally, we also investigated the effect at higher spinning rate (33.3 kHz) and compared the results with other 1H decoupling schemes (TPPM, XiX), as well as SPINAL-64 with the originally reported optimal values.  相似文献   

6.
7.
A new and efficient broadband decoupling sequence is presented. It is based on the phase cycling of two pulses with small phase angles. The pulse width is 180° ± 30°, and the phase angle is ±10°–12°. The sequence contains 16 elements, and is called SPARC-16 as an abbreviation forsmallphaseanglerapidcycling. The application of this sequence to a liquid crystalline compound, 4-n-pentyl-4′-cyanobiphenyl (5CB), is reported. The signal-to-noise ratios and the linewidths of the13C peaks of 5CB with SPARC-16 decoupling and with other decoupling methods are compared. The results show that the broadband decoupling efficiency of SPARC-16 is considerably better than those of other methods.  相似文献   

8.
The paper describes the multiple rotating frame technique for designing modulated rf fields, that perform broadband heteronuclear decoupling in solution NMR spectroscopy. The decoupling method presented here is understood by performing a sequence of coordinate transformations, each of which demodulates a component of the rf field to a static component, that progressively averages the chemical shift and the dipolar interaction. We show that by increasing the number of modulations in the decoupling field, the ratio of dispersion in the chemical shift to the strength of the static component of the rf field is successively reduced in the progressive frames. The known decoupling methods like continuous wave decoupling, TPPM, etc., can be viewed as special cases of this method and their performance improves by adding additional modulations in the decoupling field. The technique is also expected to find use in design of broadband excitation, inversion and mixing sequences and broadband experiments in solid state NMR.  相似文献   

9.
Many solid-state spectra have been shown to have problems related to the poor proton decoupling of carbon nuclei in methylene groups under conditions of slow magic-angle turning. Two-pulse phase-modulation (TPPM) decoupling during the 2D PHORMAT chemical shift separation experiment is shown to be more effective in comparison to that obtainable at much higher spin rates using conventional CW decoupling. TPPM decoupling can also alleviate similar inadequacies when observing the 15N nucleus, particularly with NH2 groups. This is demonstrated in the 15N resonances of fully labeled l-arginine hydrochloride, where a line narrowing of about a factor of two was observed at moderate rotation rates. This significant advantage was also obtained at turning frequencies as low as 500 Hz.  相似文献   

10.
Magnetically aligned bicelles are becoming attractive model membranes to investigate the structure, dynamics, geometry, and interaction of membrane-associated peptides and proteins using solution- and solid-state NMR experiments. Recent studies have shown that bicelles are more suitable than mechanically aligned bilayers for multidimensional solid-state NMR experiments. In this work, we describe experimental aspects of the natural abundance (13)C and (14)N NMR spectroscopy of DMPC/DHPC bicelles. In particular, approaches to enhance the sensitivity and resolution and to quantify radio-frequency heating effects are presented. Sensitivity of (13)C detection using single pulse excitation, conventional cross-polarization (CP), ramp-CP, and NOE techniques are compared. Our results suggest that the proton decoupling efficiency of the FLOPSY pulse sequence is better than that of continuous wave decoupling, TPPM, SPINAL, and WALTZ sequences. A simple method of monitoring the water proton chemical shift is demonstrated for the measurement of sample temperature and calibration of the radio-frequency-induced heating in the sample. The possibility of using (14)N experiments on bicelles is also discussed.  相似文献   

11.
The use of continuous-wave (CW) 1H decoupling has generally provided little improvement in the 13C MAS NMR spectroscopy of paramagnetic organic solids. Recent solid-state 13C NMR studies have demonstrated that at rapid magic-angle spinning rates CW decoupling can result in reductions in signal-to-noise and that 1H decoupling should be omitted when acquiring 13C MAS NMR spectra of paramagnetic solids. However, studies of the effectiveness of modern 1H decoupling sequences are lacking, and the performance of such sequences over a variety of experimental conditions must be investigated before 1H decoupling is discounted altogether. We have studied the performance of several commonly used advanced decoupling pulse sequences, namely the TPPM, SPINAL-64, XiX, and eDROOPY sequences, in 13C MAS NMR experiments performed under four combinations of the magnetic field strength (7.05 or 11.75T), rotor frequency (15 or 30kHz), and 1H rf-field strength (71, 100, or 140kHz). The effectiveness of these sequences has been evaluated by comparing the 13C signal intensity, linewidth at half-height, LWHH, and coherence lifetimes, T2('), of the methine carbon of copper(II) bis(dl-alanine) monohydrate, Cu(ala)(2).H2O, and methylene carbon of copper(II) bis(dl-2-aminobutyrate), Cu(ambut)(2), obtained with the advanced sequences to those obtained without 1H decoupling, with CW decoupling, and for fully deuterium labelled samples. The latter have been used as model compounds with perfect 1H decoupling and provide a measure of the efficiency of the 1H decoupling sequence. Overall, the effectiveness of 1H decoupling depends strongly on the decoupling sequence utilized, the experimental conditions and the sample studied. Of the decoupling sequences studied, the XiX sequence consistently yielded the best results, although any of the advanced decoupling sequences strongly outperformed the CW sequence and provided improvements over no 1H decoupling. Experiments performed at 7.05T demonstrate that the XiX decoupling sequence is the least sensitive to changes in the 1H transmitter frequency and may explain the superior performance of this decoupling sequence. Overall, the most important factor in the effectiveness of 1H decoupling was the carbon type studied, with the methylene carbon of Cu(ambut)(2) being substantially more sensitive to 1H decoupling than the methine carbon of Cu(ala)(2).H2O. An analysis of the various broadening mechanisms contributing to 13C linewidths has been performed in order to rationalize the different sensitivities of the two carbon sites under the four experimental conditions.  相似文献   

12.
(13)C NMR is a powerful analytical tool for characterizing polyethylene copolymer composition and sequence distribution. Accurate characterization of the composition and sequence distribution is critical for researchers in industry and academia. Some common composite pulse decoupling (CPD) sequences used in polyethylene copolymer (13)C NMR can lead to artifacts such as modulations of the decoupled (13)C NMR signals (decoupling sidebands) resulting in systematic errors in quantitative analysis. A new CPD method was developed, which suppresses decoupling sidebands below the limit of detection (less than 1:40,000 compared to the intensity of the decoupled signal). This new CPD sequence consists of an improved Waltz-16 CPD, implemented as a bilevel method. Compared with other conventional CPD programs this new decoupling method produced the cleanest (13)C NMR spectra for polyethylene copolymer composition and triad sequence distribution analyses.  相似文献   

13.
Achieving high spectral resolution is an important prerequisite for the application of solid-state NMR to biological molecules. Higher spectral resolution allows to resolve a larger number of resonances and leads to higher sensitivity. Among other things, heteronuclear spin decoupling is one of the important factors which determine the resolution of a spectrum. The process of heteronuclear spin decoupling under magic-angle sample spinning is analyzed in detail. Continuous-wave RF irradiation leads only in a zeroth-order approximation to a full decoupling of heteronuclear spin systems in solids under magic-angle spinning (MAS). In a higher-order approximation, a cross-term between the dipolar-coupling tensor and the chemical-shielding tensor is reintroduced, providing a scaled coupling term between the heteronuclear spins. In strongly coupled spin systems this second-order recoupling term is partially averaged out by the proton spin-diffusion process, which leads to exchange-type narrowing of the line by proton spin flips. This process can be described by a spin-diffusion type superoperator, allowing the efficient simulation of strongly coupled spin systems under heteronuclear spin decoupling. Low-power continuous-wave decoupling at fast MAS frequencies offers an alternative to high-power irradiation by reversing the order of the averaging processes. At fast MAS frequencies low-power continuous-wave decoupling leads to significantly narrower lines than high-power continuous-wave decoupling while at the same time reducing the power dissipated in the sample by several orders of magnitude. The best decoupling is achieved by multiple-pulse sequences at high RF fields and under fast MAS. Two such sequences, two-pulse phase-modulated decoupling (TPPM) and X-inverse-X decoupling (XiX), are discussed and their properties analyzed and compared.  相似文献   

14.
介绍了一种基于计算全息的非对称多台阶衍射光学元件印模制备方法,研究了相位型计算全息的工作原理和设计方法,建立了相应的光学系统和衍射光波模型,设计了求取相位型印模微结构的算法流程。在理论分析的基础上,以叠心图案为例,利用MATLAB分别仿真了2台阶、4台阶、8台阶、16台阶衍射光学元件的相位信息以及表面微结构形貌,并对比了其再现图像的质量,发现台阶数越多,再现图像的质量越好。获得印模空间高度数据以及表面结构分布后,利用单点金刚石车削技术,采用快刀加工方式,分别加工了元件尺寸为6 mm×6 mm,最小特征尺寸为30 um的2台阶和4台阶印模,并获得了实际加工的台阶轮廓曲线以及表面结构轮廓。最后采用紫外固化纳米压印技术实现了4台阶印模的复制过程,并对复制样品进行了图像再现,结果表明该方法能用于非对称低台阶数衍射光学元件印模的制备。  相似文献   

15.
The intensity of the carbon signal in a CPMAS experiment has been measured for two CH and three CH(2) moieties in four test molecules under different phase-modulated proton decoupling conditions and as a function of the spinning rate. The proton decoupling schemes investigated were the golden standard TPPM and three of the GTn family. Aim of this analysis was to better describe experimentally the impact and limitations of phase-modulated decoupling. Sizeable differences in the response to decoupling were observed in otherwise chemically identical molecular fragments, such as the CHCH(2) found in tyrosine, phenyl-succinic acid or 9-Anthrylmethyl-malonate, probably due to differences in spin-diffusion rates. In keeping with known facts, the efficiency of the decoupling was observed to decrease with the MAS rate, but with somewhat different trends for the tested systems.  相似文献   

16.
《中国物理 B》2021,30(10):104202-104202
Transmission matrix(TM) is an important tool for controlling light focusing, imaging, and communication through turbid media. It can be measured by 3-step(TM3) or 4-step(TM4) phase-shifting interference, but the similarities and differences of the transmission matrices obtained by the two methods are rarely reported. Therefore, we make a quantitative comparison of the peak light intensity, signal-to-noise ratio, and average background of 24 × 24 = 576 focal points between paired samples(TM3–TM4) through the Wilcoxon rank sum test, and discuss the singular value of the transmission matrix and the focal peak. The comparative results of peak light intensity and signal-to-noise ratio show that there is a significant difference between the 3-step phase shift and the 4-step phase shift transmission matrixes. The focusing effect of the former is significantly better than that of the latter; interest concentrates on the focal intensity and singular value. The reciprocal of the singular value is proportional to the squared intensity, which is in accordance with singular value theory. The results of comparison of peak light intensity and signal-to-noise ratio strongly suggest that 3-step phase shift should be selected and used in applying the phase shift method to the measurement of the transmission matrix; and the singular value is of great significance in quantifying the focusing, imaging, and communication quality of the transmission matrix.  相似文献   

17.
线宽误差对菲涅耳透镜衍射效率的影响   总被引:3,自引:1,他引:2  
基于标量衍射理论,首先得出存在线宽误差情况下4阶菲涅耳透镜衍射效率的解析式;并以 4阶、8阶和16阶菲涅耳透镜为例,进行计算机模拟计算并系统分析线宽误差对菲涅耳透镜衍射效率的影响。通过实验测量16阶菲涅耳透镜的线宽误差,分析其对16阶菲涅耳透镜衍射效率的影响。模拟计算结果对多阶菲涅耳透镜的制作提供重要的理论指导。  相似文献   

18.
Achieving phase only modulation from a spatial light modulator (SLM) is useful for many optical processing tasks. In this paper, we demonstrate a simple method of decoupling phase and amplitude modulation in a twisted nematic liquid crystal (TNLC) SLM using a double pass technique. A Jones calculus model is developed which matches our experimental data.  相似文献   

19.
In solid-state NMR studies of minerals and ion conductors, quadrupolar nuclei like 7Li, 23Na or 133Cs are frequently situated in close proximity to fluorine, so that application of 19F decoupling is beneficial for spectral resolution. Here, we compare the decoupling efficiency of various multi-pulse decoupling sequences by acquiring 19F-decoupled 23Na-NMR spectra of cryolite (Na3AlF6). Whereas the MAS spectrum is only marginally affected by application of 19F decoupling, the 3Q-filtered 23Na signal is very sensitive to it, as the de-phasing caused by the dipolar interaction between sodium and fluorine is three-fold magnified. Experimentally, we find that at moderate MAS speeds, the decoupling efficiencies of the frequency-swept decoupling schemes SWf-TPPM and SWf-SPINAL are significantly better than the conventional TPPM and SPINAL sequences. The frequency-swept sequences are therefore the methods of choice for efficient decoupling of quadrupolar nuclei with half-integer spin from fluorine.  相似文献   

20.
We report here an efficient multiple-quantum magic-angle spinning (MQMAS) pulse sequence involving fast amplitude-modulated (FAM) radio-frequency pulses for excitation and conversion of five-quantum (5Q) coherences of spin-5/2 nuclei. The use of a FAM-I type pulse train for the conversion of 5Q into 1Q coherences proves to be easier to implement experimentally than the earlier suggested use of a FAM-II type sequence [J. Magn. Reson. 154 (2002) 280], while delivering at least equal signal enhancement. Results of numerical simulations and experimental 27Al 5QMAS spectra of aluminium acetylacetonate for different excitation and conversion schemes are compared to substantiate these claims. We also demonstrate the feasibility of acquiring 5QMAS spectra of spin-5/2 systems using cogwheel phase cycling [J. Magn. Reson. 155 (2002) 300] to select the desired coherence pathways. A cogwheel phase cycle of only 57 steps is shown to be as effective as the minimum conventional nested 77-step phase cycle.  相似文献   