首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Nan Lu  Jörg P. Kutter 《Electrophoresis》2020,41(24):2122-2135
This review summarizes recent developments (over the past decade) in the field of microfluidics-based solutions for enantiomeric separation and detection. The progress in various formats of microchip electrodriven separations, such as MCE, microchip electrochromatography, and multidimensional separation techniques, is discussed. Innovations covering chiral stationary phases, surface coatings, and modification strategies to improve resolution, as well as integration with detection systems, are reported. Finally, combinations with other microfluidic functional units are also presented and highlighted.  相似文献   

2.
The field of chiral separations had a modest beginning some two decades ago. However, due to rapid technological advancement coupled with simultaneous availability of innovative chiral stationary phases and novel chiral derivatization agents, the field of chiral separations has now totally outpaced many other separation fields. Keeping pace with rapid changes in the field of chiral separations, investigators continue to add stereoselective pharmacokinetic, pharmacodynamic, pharmacologic and toxicological data of new and/or marketed racemic compounds to the literature. Examination of the evolution of chiral separations suggests that in the beginning many investigators attempted to separate and quantify a single pair of enantiomers, adopting either direct (separation made on a chiral stationary phase) or indirect (separation made following precolumn conversion of enantiomers to corresponding diastereomers) approaches. However, more recent trends in chiral separations suggest that investigators are attempting to separate and quantify multiple pairs of enantiomers with available technologies. Added to this, some interesting trends have been observed in many of the recently reported chiral applications, including preferences regarding internal standard selection, mobile phase contents and composition, sorting out issues with mass spectrometric detection, determination of elution order, analytical manipulations of metabolite(s) without reference standards and addressing some specificity-related issues. This review mainly focuses on chiral separations involving multiple chiral analytes and attempts to justify the need for such chiral separations involving multiple analytes. In this context, several cases studies are described on the utility and applicability of such chiral separations under discrete headings to provide an account to the readership on the implications of such tasks. The topics of case studies covered in this review include: (a) therapy markers--differentiation from drug abuse and/or applicability in forensics; (b) role in pharmacogenetic/polymorphic evaluation; (c) monitoring and understanding the role of parent and active metabolite(s) in clinical and preclinical investigations; (d) exploration on the pharmacokinetic utility of an active chiral metabolite vis-a-vis the racemic parent moiety; (e) understanding the chirality play in delineating peculiar toxic effects; (f) exploration of chiral inversion phenomenon, and understanding the role of stereoselective metabolism. For the further benefit of readership, some select examples (n = 19) of the separation of multiple chiral analytes with appropriate information on chromatography, detection system, validation parameters and applicable conclusion are also provided. Finally, the review covers some useful considerations for method development involving multiple chiral analytes.  相似文献   

3.
Lin YW  Huang MF  Chang HT 《Electrophoresis》2005,26(2):320-330
Capillary electrophoresis (CE) and microchip capillary electrophoresis (MCE) using polymer solutions are two of the most powerful techniques for the analysis of DNA. Problems, such as the difficulty of filling polymer solution to small separation channels, recovering DNA, and narrow separation size ranges, have put a pressure on developing new techniques for DNA analysis. In this review, we deal with DNA separation using chip-based nanostructures and nanomaterials in CE and MCE. On the basis of the dependence of the mobility of DNA molecules on the size and shape of nanostructures, several unique chip-based devices have been developed for the separation of DNA, particularly for long DNA molecules. Unlike conventional CE and MCE methods, sieving matrices are not required when using nanostructures. Filling extremely low-viscosity nanomaterials in the presence and absence of polymer solutions to small separation channels is an alternative for the separations of DNA from several base pairs (bp) to tens kbp. The advantages and shortages of the use of nanostructured devices and nanomaterials for DNA separation are carefully addressed with respect to speed, resolution, reproducibility, costs, and operation.  相似文献   

4.
Chiral separations in sub- and supercritical fluid chromatography   总被引:1,自引:0,他引:1  
Sub- and supercritical fluid chromatography (SFC) received more and more attention in pharmaceutical analysis during the last years. Especially for chiral separations, this technique is becoming increasingly popular. This review gives an overview of most chiral separation applications using SFC, covering the literature from 2000 on.  相似文献   

5.
Chiral separations of 1-aminoindan (AI) by cyclodextrin electrokinetic chromatography (CDEKC) were investigated on microfluidic quartz chips. By using a microchip electrophoresis (MCE) instrument equipped with a linear-imaging UV detector, the separation process of the enantiomeric compounds was observed. When sulfated beta-cyclodextrin was employed as a chiral selector, the baseline separation of AI could be achieved within 1 min with a high repeatability. The relative standard deviation of the migration time was less than 6%. The fastest separation was achieved in 14 s, utilizing a separation length of only 6.1 mm. These results show that the MCE analysis employing a linear imaging UV detector has a significant potential for fast chiral analysis.  相似文献   

6.
The effect of several experimental parameters on enantiomeric separations in micellar capillary electrophoresis (MCE) was studied. A model separation system was tested. It was composed of an acidic phosphate buffer with sodium dodecyl sulfate (SDS) and hydroxypropyl-beta-cyclodextrin (HP-beta-CD) as the chiral selector. A substituted angelicin was used as a chiral analyte. Changes in the concentration of SDS micelles/SDS monomers in the presence of HP-beta-CD and their impact on the enantioselective separation were investigated. Variation of the composition of electrolytes in the individual compartments of the separation system (inlet vial, capillary, and outlet vial) affected both the migration times and the resolution of the enantiomers. Current vs. time dependencies also were monitored during the separations. A mathematical model of electromigration in micellar systems with chiral selector present was proposed and a computer simulation was used to explain the observed phenomena and to confirm the generation of a CD/SDS-micelle concentration gradient under certain experimental conditions. This is the reported first attempt of a computer simulation of the complex, dynamic chiral environment of the CD-SDS-MCE system.  相似文献   

7.
High-speed chiral separations on a microchip with UV detection   总被引:2,自引:0,他引:2  
Ludwig M  Kohler F  Belder D 《Electrophoresis》2003,24(18):3233-3238
Fast chiral separations of a variety of basic and acidic compounds could be realized on microfluidic quartz chips. A microchip electrophoresis instrument equipped with a linear imaging UV-detector was used. The usually applied but troublesome fluorescence tagging in order to enable fluorescence detection could be omitted. Using sulfated cyclodextrins as chiral selectors baseline separation of 19 compounds could be achieved in less than 1 min with high reproducibility. The relative standard deviation of migration time was below 7%. The fastest separation could be performed in 2.5 s which is to date the fastest separation of enantiomers reported. It was possible to apply microchip electrophoresis (MCE) for the determination of high enantiomeric excess (ee) values, as exemplarily shown for pseudoephedrin where 2% of the minor enantiomer could reliably be determined beside high amount of the other isomer. Successful separation of a mixture of 3 chiral drugs could be performed in a single run in less than 11 s utilizing a separation length of only 12 mm. These results show that MCE has great potential for fast chiral analysis and high-throughput screening.  相似文献   

8.
Enantioselective separations have been one of the most successful applications of supercritical fluid chromatography (SFC). Although analytical scale separations have dominated the literature, the use of SFC for preparative chiral separations is growing. Both analytical and preparative scale SFC separations seek to take advantage of the high efficiency, high throughput, and rapid method development associated with the technique. This review will cover recent developments in the application of SFC to enantioseparations.Contribution of the National Institute of Standards and Technology. Not subject to copyright.  相似文献   

9.
Belder D  Deege A  Maass M  Ludwig M 《Electrophoresis》2002,23(14):2355-2361
A modular instrument for high-speed microchip electrophoresis (MCE) equipped with a sensitive variable-wavelength fluorescence detection system was developed and evaluated. The experimental setup consists mainly of a lamp-based epifluorescence microscope for variable-wavelength fluorescence detection and imaging and a programmable four-channel bipolar high-voltage source capable of delivering up to +/- 10 kV per channel. The optical unit was equipped with a high-sensitivity photomultiplier tube and an adjustable aperture. The system was applied to MCE separations of flurescein isothiocyanate (FITC)-labelled amines utilizing blue light (450-480 nm) for excitation as well as for the separation of rhodamines utilizing excitation light in the green spectral region (531-560 nm). At optimized conditions baseline separation of four FITC-labelled amines could be obtained in less than 50 s at a detection limit of 460 ppt (1 nM) with a signal-to-noise ratio of 3:1. Three rhodamines could be baseline-separated in less than 6 s at a detection limit of 240 ppt (500 pM). The relative standard deviations of absolute migration times determined in repetitive MCE separations of FITC-labelled amines were below 2.5% (n= 25). By the application of cyclodextrin-modified electrolytes, chiral separation of FITC-labelled amines could be performed in seconds demonstrating the potential of microchip electrophoresis for chiral high-throughput screening.  相似文献   

10.
Enantiomers represent a class of compounds extensively investigated since they can show totally different behaviors when they interact with a chiral environment. Because of their identical chemical structure (they differ only in the spatial arrangement of the atoms in the molecule), the separation of optical isomers is a challenging task of analytical chemistry. So far employed methods for the separation of enantiomers are mainly based on chromatography. CE as well was considered as an analytical technique suitable for chiral separations, characterized by high efficiency and low consumption of reagent. Recently, miniaturization was introduced in LC to answer the needs to perform analyses in the minimum time, to use the smallest amount of samples and to reduce environmental pollution. Nano‐LC represents nowadays a valid alternative to the abovementioned conventional analytical techniques, and can be advantageously exploited for enantiomeric separation especially because it needs minute amounts of the chiral material necessary to carry out enantiomeric separations. This review describes the development and applications of nano‐LC in the field of chiral separations. The data reported in literature show its relevance for the study enantiomers‐chiral selectors interaction, as well as for application in pharmaceutical and clinical research.  相似文献   

11.
This review highlights the methodological and instrumental developments in microchip micellar EKC (MCMEKC) from 1995. The combination of higher separation efficiencies in micellar EKC (MEKC) with high-speed separation in microchip electrophoresis (MCE) should provide high-throughput and high-performance analytical systems. The chip-based separation technique has received considerable attention due to its integration ability without any connector. This advantage allows the development of a multidimensional separation system. Several types of 2-D separation microchips are described in the review. Since complicated channel configurations can easily be fabricated on planar substrates, various sample manipulations can be carried out prior to MCMEKC separations. For example, mixing for on-chip reactions, on-line sample preconcentration, on-chip assay, etc., have been integrated on MEKC microchips. The application of on-line sample preconcentration to MCMEKC can provide not only sensitivity enhancement but also the elucidation of the preconcentration mechanism due to the visualization ability of MCE. The characteristics of these sample manipulations on MEKC microchips are presented in this review. The scope of applications in MCMEKC covers mainly biogenic compounds such as amino acids, peptides, proteins, biogenic amines, DNA, and oestrogens. This review provides a comprehensive table listing the applications in MCMEKC in relation to detection methods.  相似文献   

12.
Chiral dihydrofurocoumarin compounds are currently the focus of industrial and pharmacological research. These derivatives have been shown to possess many physiological properties that could be medically beneficial. This work proposes four different chiral separation methods using capillary electrophoresis and micellar capillary electrophoresis (MCE). Several different cyclodextrin chiral selectors were examined to evaluate their effectiveness in the enantioseparation of dihydrofurocoumarins. In addition, the effects of the chiral selector concentration, the presence of an organic modifier, run buffer pH, and in two cases, the ratio between the chiral selector and an additional charged pseudophase were investigated. Overall, the best separations for this class of chiral compounds were achieved using sulfated beta-cyclodextrins at low pH in the reversed polarity mode.  相似文献   

13.
This review covers recent progress in polyelectrolyte multilayer (PEM) coatings applied to analytical separations using open-tubular capillary electrochromatography (OT-CEC). The simple preparation procedure involved in the PEM approach has provided some attractive features over other modes of capillary electrophoresis-based separations including packed column capillary electrochromatography (PC-CEC) and micellar electrokinetic chromatography (MEKC). PEM coatings have been used to alleviate the adsorption of basic analytes, to improve separations, and to improve the stability of the electroosmotic flow. Fundamental aspects of PEM coatings on surfaces and analytical separation platforms are briefly outlined in this review. In addition, applications of PEM coatings to fused-silica capillaries or microchip separation devices for the separation of small achiral or chiral analytes, as well as large biomolecules, are discussed.  相似文献   

14.
Monolithic supports are a new generation of stationary phases which are typically prepared using a simple molding process carried out within the confines of the capillary. They provide high rates of mass transfer at lower pressure drops, enable much faster separations and the nature of the pores allows easy permeability for large molecules. This review summarizes the current achievements and application of organic polymer-based monolithic columns, silica-based monolithic columns and their application in bioaffinity processing, modern biotechnology, determination of microorganisms and chiral separations. Special attention is paid to microfabricated devices with monolithic supports because their fabrication of particles directly in the channel eliminates the need for a frit and also creates a unique homogeneity of packing.  相似文献   

15.
MEEKC is an electrodriven separation technique that utilises the unique properties of a microemulsion (ME) as a background electrolyte to achieve separation of a diverse range of solutes. MEs are composed of nanometre-sized oil droplets suspended in aqueous buffer, which is commonly referred to as oil-in-water ME. The droplets are stabilised by the presence of both a surfactant and co-surfactant. The use of water-in-oil MEs in MEEKC has also been investigated. This review details the advances in MEEKC-based separations from the period June 2008 - June 2010. Areas covered include online sample concentration, suppressed electroosmosis MEEKC, chiral separations, MEEKC-MS, MEEKC-ICP-MS and ME structure characterisation. The review also includes a fundamental introduction to MEEKC, along with a review of recent applications.  相似文献   

16.
Recent developments in optical detection methods for microchip separations   总被引:4,自引:0,他引:4  
This paper summarizes the features and performances of optical detection systems currently applied in order to monitor separations on microchip devices. Fluorescence detection, which delivers very high sensitivity and selectivity, is still the most widely applied method of detection. Instruments utilizing laser-induced fluorescence (LIF) and lamp-based fluorescence along with recent applications of light-emitting diodes (LED) as excitation sources are also covered in this paper. Since chemiluminescence detection can be achieved using extremely simple devices which no longer require light sources and optical components for focusing and collimation, interesting approaches based on this technique are presented, too. Although UV/vis absorbance is a detection method that is commonly used in standard desktop electrophoresis and liquid chromatography instruments, it has not yet reached the same level of popularity for microchip applications. Current applications of UV/vis absorbance detection to microchip separations and innovative approaches that increase sensitivity are described. This article, which contains 85 references, focuses on developments and applications published within the last three years, points out exciting new approaches, and provides future perspectives on this field.  相似文献   

17.
微乳液毛细管电动色谱(MEEKC)是在胶束电动色谱基础上发展起来的一种电动色谱新技术。近几年来,MEEKC在各个领域的应用又有了长足的进步,尤其是在维生素、药物、天然产物、手性分离、生物分子、环境分析,以及药物疏水性评价上呈现出强势的发展,本文针对这些领域的MEEKC方法进行了评述。  相似文献   

18.
The current popularity of capillary electrochromatography (CEC) has led to an increasing number of studies on the development and evaluation of enantioselective CEC systems. These studies clearly demonstrate that the most prominent advantage of electrically driven separation methods, the vastly increased column efficiency as compared to pressure-driven chromatography, can also be experimentally achieved for the separations of enantiomers. In analogy to high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE), several approaches have been used. The addition of a chiral selector to the mobile phase is the simplest method. Less erroneous and more elegant approaches are those that use open-tubular, conventional packed, and monolithic columns containing chiral stationary phases that stereoselectively interact with enantiomers. This review evaluates the new techniques and compares them to enantioselective HPLC and CE. Further, it describes the various concepts of enantioselective CEC and focuses on the current ‘state-of-the-art' column technology.  相似文献   

19.
An overview of the state-of-the-art in LC enantiomer separation is presented. This tutorial review is mainly focused on mechanisms of chiral recognition and enantiomer distinction of popular chiral selectors and corresponding chiral stationary phases including discussions of thermodynamics, additivity principle of binding increments, site-selective thermodynamics, extrathermodynamic approaches, methods employed for the investigation of dominating intermolecular interactions and complex structures such as spectroscopic methods (IR, NMR), X-ray diffraction and computational methods. Modern chiral stationary phases are discussed with particular focus on those that are commercially available and broadly used. It is attempted to provide the reader with vivid images of molecular recognition mechanisms of selected chiral selector–selectand pairs on basis of solid-state X-ray crystal structures and simulated computer models, respectively. Such snapshot images illustrated in this communication unfortunately cannot account for the molecular dynamics of the real world, but are supposed to be helpful for the understanding. The exploding number of papers about applications of various chiral stationary phases in numerous fields of enantiomer separations is not covered systematically.  相似文献   

20.
The application of peptides in chiral separations using techniques such as capillary electrophoresis (CE), electrokinetic capillary chromatography (EKC) and liquid chromatography is the focus of this review. Methods for finding peptide selectors using combinatorial library approaches are discussed, as well as recent advances in the use of peptides as general chiral selectors for electrophoresis and liquid chromatography. One example shows the effectiveness of polymeric dipeptide surfactants as general chiral selectors for electrophoresis. Another example shows the versatility of oligoproline chiral stationary phases, exhibiting resolution for a number of racemic analytes comparable to other well-established chiral stationary phases.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号