首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Important parameters to consider when developing a liquid chromatography/mass spectrometry (LC/MS) method are buffer type and concentration, and column geometry. In the work presented here the choice of buffer for the analysis of basic compounds using a polar embedded phase (HyPURITYtrade mark ADVANCE) is illustrated for the analysis of tricyclic antidepressants. Method transfer from a 4.6 mm i.d. column to a 2.1 mm i.d. column is demonstrated for the analysis of triazines and anabolic steroids and their metabolites, with no change in selectivity and with added speed of analysis. Analysis of eight beta-blockers is achieved in 65 seconds by using a short 30 x 4.6 mm C18 column.  相似文献   

2.
陈文锐  陈永红  胡国昌 《色谱》1998,16(5):451-453
采用HPLC-MS联用法测定了具有改善睡眠等特定功能的保健药品中的褪黑激素。利用质谱谱库检索和二极管阵列检测光谱图鉴定“松果体素”药品中的褪黑激素,以甲醇-水(70∶30)为流动相,检测波长为275nm。用外标法进行定量分析,方法最低检测限为0.2ng。  相似文献   

3.
The reliability of ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC- MS/MS) for high throughput screening in anti-doping control has been tested. A method to screen for the presence of diuretics and other doping agents in urine has been optimised and validated. The extraction procedure consisted of an alkaline extraction (pH 9.5) with ethyl acetate and salting-out effect (sodium chloride). The extracts were analysed by UPLC-MS/MS. Analysis of 34 forbidden drugs and metabolites was achieved in a total run time of 5 min, using a C18 column (100 mm x 2.1 mm i.d., 1.7 microm particle size) and a mobile phase containing deionised water and acetonitrile with formic acid, with gradient elution at a flow-rate of 0.6 mL min(-1). Identification of the compounds was performed by multiple reaction monitoring, using electrospray ionisation in positive- or negative-ion mode. Precursor and product ions were studied for each compound and cone voltage and collision energy were optimised. Due to the different chemical structure of the compounds under study, extraction recoveries varied from less than 10% to 100% depending on the analyte. The limits of detection ranged from 50 ng mL(-1) to 200 ng mL(-1), and all the compounds comply with the requirements of quality established by the World Anti-doping Agency. Intra-assay precision was evaluated at two concentrations for each compound and, in most cases, a relative standard deviation of the signal ratio lower than 20% was obtained. The method has demonstrated to be reliable when analysing routine samples and the short analysis time resulting from a simple sample preparation and a rapid instrumental analysis allow a fast turn-around time and makes it of great interest for routine anti-doping control purposes.  相似文献   

4.
王晓春  王涵文  马继平  徐烨  关亚风 《色谱》2004,22(2):101-105
首次将填充毛细管高效液相色谱-毛细管气相色谱在线联用技术(μ-HPLC-CGC)用于分离分析八角茴香果实的挥发油成分。液相色谱选用氰基分析柱(250 mm×0.32 mm i.d.),正己烷-乙腈-二氯甲烷(体积比为80∶8∶12)为流动相,对挥发油样品做族组分分离,得到的5个族组分被依次存放在多位储存接口内,然后不分流分别转入毛细管气相色谱仪做详细分析。气相色谱柱由10 m×0.53 mm i.d.保留间隔柱和30 m×0.53 mm i.d.×1.0 μm SE-54分析柱组成。采用了不分流柱内进样模  相似文献   

5.
A specific and sensitive direct-injection high performance liquid chromatography electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS) method has been developed for the rapid identification and quantitative determination of olanzapine, clozapine, and N-desmethylclozapine in human plasma. After the addition of the internal standard dibenzepin and dilution with 0.1% formic acid, plasma samples were injected into the LC/MS/MS system. Proteins and other large biomolecules were removed during an online sample cleanup using an extraction column (1 x 50 mm i.d., 30 microm) with a 100% aqueous mobile phase at a flow rate of 4 mL/min. The extraction column was subsequently brought inline with the analytical column by automatic valve switching. Analytes were separated on a 5 microm Symmetry C18 (Waters) analytical column (3.0 x 150 mm) with a mobile phase of acetonitrile/0.1% formic acid (20:80, v/v) at a flow rate of 0.5 mL/min. The total analysis time was 6 min per sample. The inter- and intra-assay coefficients of variation for all compounds were <11%. By eliminating the need for extensive sample preparation, the proposed method offers very large savings in total analysis time.  相似文献   

6.
魏泱  郭亮  丁明玉 《色谱》2001,19(6):520-522
采用二醇基柱分离、蒸发光散射检测法测定了饮料中的糖。比较了乙腈-水、二氯甲烷-甲醇两种流动相分析糖的特点。采用二氯甲烷-甲醇为流动相,果糖、葡萄糖、蔗糖、麦芽糖和棉子糖的峰面积与绝对进样量的标准曲线在绝对进样量为1.6μg-40μg时均具有良好的线性关系。该方法对上述5种糖的检测限分别为0.20μg,0.16μg,0.16μg,0.20μg和0.20μg。  相似文献   

7.
《Analytical letters》2012,45(8):1417-1429
Abstract

An HPLC procedure for the estimation of trace hydrazine levels in phenelzine sulfate drug substance has been developed. The hydrazine is derivatized at ambient temperature with salicylaldehyde, and the salazine derivative is measured using short wavelength UV (209 nm). The salazine is separated from unreacted salicylaldehyde and other compounds using a mobile phase consisting of 60:40 acetonitrile-water. The mobile phase was pumped at a flow rate of 1.0 mL/min through a 150 mm × 4.6 mm i.d. reverse phase column (5 μm octadecylsilane, 30% carbon loading). The limit of detection of salazine produced when hydrazine sulfate reacts with salicylaldehyde in an analytical sample was found to be equivalent to 10 ppm of hydrazine (based upon 100 mg of phenelzine sulfate). Absorbance and hydrazine concentration are linear over the range of 10–1000 ppm of hydrazine, with an r2 of 0.9998 (n=7) based on peak height. Five samples of phenelzine sulfate analyzed for hydrazine content with salicylaldehyde gave an interassay reproducibility of 2.1%.  相似文献   

8.
Ultra high-performance liquid chromatographic (UHPLC) systems on columns packed with materials ranging from 1.9 to 2.7 μm average particle size were assessed for the fast and sensitive analysis of porphyrins in clinical materials. The fastest separation was achieved on an Agilent Poroshell C(18) column (2.7 μm particle size, 50 × 4.6 mm i.d.), followed by a Thermo Hypersil Gold C(18) column (1.9 μm particle size, 50 × 2.1 mm i.d.) and the Thermo Hypersil BDS C(18) column (2.4 μm particle size, 100 × 2.1 mm i.d.). All columns required a mobile phase containing 1 m ammonium acetate buffer, pH 5.16, with a mixture of acetonitrile and methanol as the organic modifiers for optimum resolution of the type I and III isomers, particularly for uroporphyrin I and III isomers. All UHPLC columns were suitable and superior to conventional HPLC columns packed with 5 μm average particle size materials for clinical sample analysis.  相似文献   

9.
A fast and sensitive capillary liquid chromatography (cLC) column-switching method with electrospray ionization time-of-flight mass spectrometry (ESI-TOF-MS) detection for the simultaneous determination of dopamine (D), epinephrine (E), norepinephrine (NE) and serotonin (SE) was pursued. A sample volume of 100 microl was loaded with a mobile phase containing 0.1% pentafluoropropionic acid (PFPA) as ion-pairing agent on a 25 mm x 0.32 mm (i.d.) 5 microm Hypercarb column. A water-acetonitrile (AcN) gradient with 0.1% acetic acid (AcOH) backflushed the compounds onto a 34 mm x 0.32 mm (i.d.) 5 microm Hypercarb analytical column. However, during a series of analyses, oxidation of the catecholamines (CAs) was observed. This was suspected to be due to the loading mobile phase composition and precluded the usefulness of this method even though the achievable detection limit was in the range of 0.75-3.0 ng/ml. The combination of the porous graphitic carbon (PGC) material and the fluorinated strong acids which were required to get enough retention for preconcentration of large volumes cannot be used for easily oxidized compounds as the CAs.  相似文献   

10.
在线高效液相色谱-毛细管气相色谱联用方法的建立   总被引:2,自引:0,他引:2  
陈吉平  黄威东  张乐沣  田玉增 《色谱》1997,15(3):222-224
建立了一种以保留间隙柱技术和阀切换以及定量管样品转移为接口并具有早期溶剂蒸气出口的在线液相色谱与毛细管气相色谱联用方法。考察了主要实验条件,如溶剂蒸发温度、载气压力等对联机系统性能的影响,并用萘和联苯对该系统的线性范围进行了测定。利用联机系统对一种轻柴油样品进行了分析。  相似文献   

11.
The selective determination of trimethylamine (TMA) in air by liquid chromatography is reported. Sampling is effected by flushing air through C18-packed solid-phase extraction (SPE) cartridges at a flow rate of 15 mL/min for 15 min. Next, TMA is desorbed from the cartridges and injected into the chromatographic system. The analyte is then selectively retained on a precolumn (20 mm x 2.1 mm i.d., packed with 30 microm, Hypersil C18 phase), and derivatized on-line by injecting 9-fluorenylmethyl chloroformate (FMOC). Finally, the TMA-FMOC derivative is transferred to the analytical column (125 mm x 4 mm i.d., LiChrospher 100 RP18, 5 microm), and monitored at 262 nm. The method was applied to the measurement of TMA in air in the 0.25-2.5 microg interval (equivalent to concentrations of TMA of 1.1-11 mg/m3), providing good linearity, reproducibility and accuracy. The mean recovery of TMA was (96 +/- 7%) (n = 12), and the limit of detection was 0.05 microg. The proposed procedure allows the selective determination of TMA in the presence of other primary and secondary short-chain aliphatic amines.  相似文献   

12.
A solid-phase extraction coupled to liquid chromatography/tandem mass spectrometry for the determination of estrogens in sewage influent and effluent has been performed. The possibility of preparing estrogen derivatives directly on a solid-phase extraction bed in which the targeted analytes have been previously isolated and pre-concentrated was explored. This method uses an Oasis HLB column (2.1 mm x 20 mm i.d.) for on-line sample cleanup and derivatization support, and a Sunfire C(18) column (150 mm x 2.1 mm i.d.) with a mobile phase consisting of acetonitrile-water-formic acid for separation. After sample introduction, some matrix interferences are removed by washing up SPE column with methanol-water. Phenolic hydroxyl group of estrogens is subsequently derivatized with dansyl chloride. Reaction takes place in the on-line solid-phase extraction column. The excess of reagent and other matrix interferences are then removed by a second washing. Dansylated estrogens are further back eluted and analyzed with HPLC-MS-MS. The optimized on-line protocol is emphasized owing to a low limit of quantification (1 ng L(-1)) is achieved with only around 1 mL of sample and a low sensitive MS instrument. Developed strategy has been demonstrated to be an improvement over existing methods due to its greater sensitivity and the low volume of matrix used and the total analysis time (extraction, derivatization, analysis) is less than 17 min.  相似文献   

13.
Miniaturization embracing instrumentation, column particle size, and column dimensions is one of the major current trends in separation techniques. This leads to shortening of analysis time and great savings in solvent consumption. Ultra performance liquid chromatography (UPLC) is one of the new developments in liquid chromatography. An ultra-high pressure system allows using of small particle-packed columns with small diameter, which has a positive effect on both system efficiency and analysis time. An analytical method for determination of the active substance diclofenac, the degradation product 1-(2,6-dichlorphenyl)-2-indolinone, and the preservatives methylparaben and propylparaben was used for testing and comparing LC systems. Various octadecylsilica-based analytical columns were examined. Acquity UPLC BEH C18 (2.1 x 50 mm, 1.7 microm) and (2.1 x 100 mm, 1.7 microm) were tested for UPLC. The following analytical columns were used in a test for HPLC: Purospher RP 18e (125 x 4.0 mm, 5 microm), Zorbax Eclipse XDB C18 (75 x 4.6 mm, 3.5 microm), Zorbax Eclipse SB C18 (50 x 4.6 mm, 1.8 microm), as was a monolithic column (Chromolith Performance RP-18e (100 x 4.6 mm). Results of a System Suitability Test (SST) were calculated and compared for each chromatographic peak. System efficiency and analysis duration were compared with regard to solvent consumption and system maintenance  相似文献   

14.
色谱与色谱/质谱法相结合分析热裂解汽油C9馏分   总被引:3,自引:0,他引:3  
王华  刘文民  徐媛  关亚风 《色谱》2006,24(6):615-618
采用毛细管气相色谱-氢火焰离子化检测器(CGC-FID)和气相色谱-质谱法(GC/MS)分析了热裂解汽油C9 馏分的组成。实验使用PONA毛细管气相色谱柱(100 m×0.25 mm i.d.×0.5 μm),根据烃类化合物在PONA柱上的保留规律,以正构烷烃标样保留值作为碳数分布依据,定量分析了裂解汽油C9 馏分中烃类化合物的碳数分布和单体烃含量;用GC/MS联用技术和CGC保留值定性法相结合对裂解汽油C9 馏分中相对含量大于0.2%的39种化合物进行了定性。  相似文献   

15.
A new method was developed and fully validated for the quantitation of benazepril, benazeprilat and hydrochlorothiazide in human plasma. Sample pretreatment was achieved by solid-phase extraction (SPE) using Oasis HLB cartridges. The extracts were analysed by high-performance liquid chromatography (HPLC) coupled to a single-quadrupole mass spectrometer (MS) with an electrospray ionization interface. The MS system was operated in selected ion monitoring (SIM) modes. HPLC was performed isocratically on a reversed-phase porous graphitized carbon (PGC) analytical column (2.1 x 125.0 mm i.d., particle size 5 microm). The mobile phase consisted of 55% acetonitrile in water containing 0.3% v/v formic acid and pumped at a flow rate of 0.15 ml min(-1). Chlorthalidone was used as the internal standard (IS) for quantitation. The assay was linear over a concentration range of 5.0-500 ng ml(-1) for all the compounds analysed, with a limit of quantitation of 5 ng ml(-1) for all the compounds. Quality control (QC) samples (5, 10, 100 and 500 ng ml(-1)) in five replicates from three different runs of analyses demonstrated intra-assay precision (coefficient of variation (CV) < or =14.6%), inter-assay precision (CV < or = 5.6%) and overall accuracy (relative error less than -8.0%). The method can be used to quantify benazepril, benazeprilat and hydrochlorothiazide in human plasma, covering a variety of pharmacokinetic or bioequivalence studies.  相似文献   

16.
Quigley WW  Ecker ST  Vahey PG  Synovec RE 《Talanta》1999,50(3):569-576
The development of liquid chromatography with a commercially available cyano propyl stationary phase and a 100% water mobile phase is reported. Separations were performed at ambient temperature, simplifying instrumental requirements. Excellent separation efficiency using a water mobile phase was achieved, for example N=18 800, or 75 200 m(-1), was obtained for resorcinol, at a retention factor of k'=4.88 (retention time of 9.55 min at 1 ml min(-1) for a 25 cmx4.6 mm i.d. column, packed with 5 mum diameter particles with the cyano propyl stationary phase). A separation via reversed phase liquid chromatography (RP-LC) with a 100% water mobile phase of six phenols and related compounds was compared to a separation of the same compounds by traditional RP-LC, using octadecylsilane (ODS), i.e. C18, bound to silica and an aqueous mobile phase modified with acetonitrile. Nearly identical analysis time was achieved for the separation of six phenols and related compounds using the cyano propyl stationary phase with a 100% water mobile phase, as compared to traditional RP-LC requiring a relatively large fraction of organic solvent modifier in the mobile phase (25% acetonitrile:75% water). Additional understanding of the retention mechanism with the 100% water mobile phase was obtained by relating measured retention factors of aliphatic alcohols, phenols and related compounds, and chlorinated hydrocarbons to their octanol:water partition coefficients. The retention mechanism is found to be consistent with a RP-LC mechanism coupled with an additional retention effect due to residual hydroxyl groups on the cyano propyl stationary phase. Advantages due to a 100% water mobile phase for the chemical analysis of alcohol mixtures and chlorinated hydrocarbons are reported. By placing an absorbance detector in-series and preceding a novel drop interface to a flame ionization detector (FID), selective detection of a separated mixture of phenols and related compounds and aliphatic alcohols is achieved. The compound class of aliphatic alcohols is selectively and sensitively detected by the drop interface/FID, and the phenols and related compounds are selectively and sensitively detected by absorbance detection at 200 nm. The separation and detection of chlorinated hydrocarbons in a water sample matrix further illustrated the advantages of this methodology. The sensitivity and selectivity of the FID signal for the chlorinated hydrocarbons are significantly better than absorbance detection, even at 200 nm. This methodology is well suited to continuous and automated monitoring of water samples. The applicability of samples initially in an organic solvent matrix is explored, since an organic sample matrix may effect retention and efficiency. Separations in acetonitrile and isopropyl alcohol sample matrices compared well to separations with a water sample matrix.  相似文献   

17.
Spácil Z  Nováková L  Solich P 《Talanta》2008,76(1):189-199
Two novel chromatographic methods both based on utilization of sub-2-micron particle columns were developed for the analysis of phenolic compounds in this work. An HPLC system was equipped with C(18) silica-based analytical column (50 mm x 4.6 mm, 1.8 microm) and a UPLC system with ethylene-bridged hybrid C(18) analytical column (100 mm x 2.1 mm, 1.7 microm). In total 34 phenolic substances were divided into groups of phenolic acids, flavonoids, catechins and coumarins and were analysed in sequence using different gradient methods. System suitability test data, including repeatability of retention time and peak area, mean values of asymmetry factor, resolution, peak capacity and the height equivalent of a theoretical plate were determined for each gradient method by 10 replicate injections. The developed methods were applied in the analysis of real samples (grape wines, teas).  相似文献   

18.
A simple, sensitive and rapid liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method was developed and validated for simultaneous quantification of olanzapine, clozapine, ziprasidone, haloperidol, risperidone, and its active metabolite 9-hydroxyrisperidone, in rat plasma using midazolam as internal standard (IS). The analytes were extracted from rat plasma using a single step liquid-liquid extraction technique. The compounds were separated on a Waters Atlantis dC-18 (30 mm x 2.1 mm i.d., 3 microm) column using a mobile phase of acetonitrile/5 mM ammonium formate (pH 6.1 adjusted with formic acid) with gradient elution. All of the analytes were detected in positive ion mode using multiple reaction monitoring (MRM). The method was validated and the specificity, linearity, lower limit of quantitation (LLOQ), precision, accuracy, recoveries and stability were determined. LLOQ was 0.1 ng/mL and correlation coefficient (R(2)) values for the linear range of 0.1-100 ng/mL were 0.997 or greater for all the analytes. The intra-day and inter-day precision and accuracy were better than 8.05%. The relative and absolute recovery was above 77% and matrix effects were low for all the analytes except for ziprasidone. This validated method has been successfully used to quantify the plasma concentration of the analytes after chronic treatment with antipsychotic drugs.  相似文献   

19.
An improved comprehensive two-dimensional (LC x LC) HPLC system for the analysis of triacylglycerols was developed. In the first-dimension, a Ag(I)-coated cation exchanger (250 mm x 2.1 mm, 5 microm) was employed with a gradient from 100% MeOH to 6% MeCN in MeOH at 20 microL/min. Using a 10-way valve with two switching loops, 1 min sections of the first-dimension were introduced in the second-dimension consisting of a 30 mm x 4.6 mm C18 (1.8 microm) column with an isocratic mobile phase of methanol-methyl tert-butyl ether (70:30) at 3.0 mL/min. As the second-dimension solvent was stronger than the first-dimension solvent, focusing in the second-dimension took place, leading to better separations than in previously reported analyses in which hexane was the main constituent of the first-dimension eluent. Compounds differing by 2 in their partition number were baseline separated in the second-dimension. Detection took place by UV at 210 nm, evaporative light scattering and (+)-atmospheric pressure chemical ionisation-MS with the latter giving the best results. Corn oil was investigated and 44 compounds could be detected: 34 triacylglycerols (TAGs), 8 oxygenated TAGs, and 2 TAGs containing a trans double bond. Data manipulation allowed the construction of contour plots and the automated calculation of the first- and second-dimension retention times and peak areas. Quantitative results are compared with a fatty acid methyl ester analysis, and with literature data.  相似文献   

20.
Textiles excavated from Scottish sites belonging now to the collections of the National Museums of Scotland, including seventeenth century textiles from peat bogs in the Scottish Highlands and Islands, were selected for analysis by high performance liquid chromatography with photodiode array detection (PDA HPLC) to detect whether any dyes remained and, if so, to identify their biological sources. Dye components were identified in 36 of the 81 samples analysed. Although it was not possible to identify the exact sources of the dyestuffs because of the wide-spread occurrence of these natural dyes components, the study has shown that textiles previously not thought to have been coloured had detectable traces of dye. Before the historical textiles were analyzed, an improved extraction procedure that combined the routine acid hydrolysis method with one using dimethylformamide (DMF) was applied. The DMF method enabled increased recovery of major flavonoid and anthraquinoid compounds, and very high efficiency of recovery of indigotin even in textiles with no colour visible, thereby complementing the acid hydrolysis method already in use. Extracts from historical thread samples were analysed by PDA HPLC using a reversed-phase gradient system comprising of a C18 column (150 mm x 4.6 mm i.d., 25 +/- 1 degrees C) with water, methanol and o-phosphoric acid at an eluent flow rate of 1.2 ml/min. A preliminary investigation to improve the detection limits further for a selection of natural dyes was made by comparing results from the 4.6mm internal diameter (i.d.) column with a narrow bore C18 column (2.1 mm i.d.). An increase in the detector response was observed for narrow-bore column proving its possibility of enhancement of sensitivity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号