Popa TV  Mant CT  Hodges RS 《Electrophoresis》2004,25(9):1219-1229
The present study compares a charge/hydrophobicity capillary electrophoresis (CE) approach to reversed-phase high-performance liquid chromatography (RP-HPLC) for the separation of three series of four synthetic, random coil peptide standards. Each series has peptides of the same positive charge (+1, +2 and +3 series) and length but differing in hydrophobicity. Complete resolution of the 12 peptides was achieved via a novel CE approach: a capillary zone electrophoresis (CZE) mode effected a separation of identically charged peptides; within each charged group of peptides, the addition of perfluorinated acid anionic ion-pairing reagents allowed resolution of the peptides through a mechanism based on peptide hydrophobicity which we have termed ioninteraction (II)-CZE. The peak capacity and peptide resolution of this CE approach was superior to that of RP-HPLC and stresses an important role for CE for peptide/proteomic applications.  相似文献   

2.
We have employed a novel capillary electrophoresis (CE) approach recently developed in our laboratory, termed ion-interaction-capillary zone electrophoresis (II-CZE), to the resolution of a mixture of 27 synthetic cationic proteomic peptide standards. These peptides were comprised of three groups of nine peptides (with net charges of +1, +2 and +3 for all nine peptides within a group), the hydrophobicity of the nine peptides within a group varying only subtly between adjacent peptides. This bidimensional CE approach achieved excellent resolution of the peptides with high peak capacity by combining the powerful CZE mechanism located in the background electrolyte (BGE) with an hydrophobicity-based mechanism also located in the BGE, the latter consisting of high concentrations (up to 0.4M) of aqueous perfluorinated acids (trifluoroacetic acid, pentafluoropropionic acid and heptafluorobutyric acid). Thus, concomitant with a CZE separation of the three differently charged groups of peptides, there is an hydrophobically-mediated separation of the peptides within these groups effected through interaction of the hydrophobic anions of the perfluorinated acids with hydrophobic amino acid side-chains in the peptides. This methodology is dramatically different from other CE methods that have used complexing agents such as micelles or cyclodextrins in MEKC. Overall, the results presented here demonstrate the value of CE as a peptide separative tool in its own right, including its use for proteomic applications, and not merely as a complementary technique to reversed-phase high-performance liquid chromatography (RP-HPLC).  相似文献   

3.
The present study uses an unique capillary electrophoresis (CE) approach, that we have termed ion-interaction capillary zone electrophoresis (II-CZE), for the separation of diastereomeric peptide pairs where a single site in the centre of the non-polar face of an 18-residue amphipathic alpha-helical peptide is substituted by the 19 L- or D-amino acids. Through the addition of perfluorinated acids at very high concentrations (up to 400 mM), such concentration levels not having been used previously in chromatography or CE, to the background electrolyte (pH 2.0), we have been able to achieve baseline resolution of all 19 diastereomeric peptide pairs with an uncoated capillary. Since each diastereomeric peptide pair has the same sequence, identical mass-to-charge ratio and identical intrinsic hydrophobicity, such a separation by CZE has previously been considered theoretically impossible. Excellent resolution was achieved due to maximum advantage being taken of even subtle disruption of peptide structure/conformation (due to the presence of D-amino acids) of the non-polar face of the amphipathic alpha-helix and its interaction with the hydrophobic anionic ion-pairing reagents. In addition, due to the excellent resolution of diastereomeric peptide pairs by this novel CZE approach, we have also been able to separate a mixture of these closely-related alpha-helical peptides.  相似文献   

4.
Simpson DC  Smith RD 《Electrophoresis》2005,26(7-8):1291-1305
Mass spectrometry (MS)-based proteomics is currently dominated by the analysis of peptides originating either from digestion of proteins separated by two-dimensional gel electrophoresis (2-DE) or from global digestion; the simple peptide mixtures obtained from digestion of gel-separated proteins do not usually require further separation, while the complex peptide mixtures obtained by global digestion are most frequently separated by chromatographic techniques. Capillary electrophoresis (CE) provides alternatives to 2-DE for protein separation and alternatives to chromatography for peptide separation. This review attempts to elucidate how the most promising CE modes, capillary zone electrophoresis (CZE) and capillary isoelectric focusing (CIEF), might best be applied to MS-based proteomics. CE-MS interfacing, mass analyzer performance, column coating to minimize analyte adsorption, and sample stacking for CZE are considered prior to examining numerous applications. Finally, multidimensional systems that incorporate CE techniques are examined; CZE often finds use as a fast, final dimension before ionization for MS, while CIEF, being an equilibrium technique, is well-suited to being the first dimension in automated fractionation systems.  相似文献   

5.
An in-capillary electrode sheathless interface was applied to the capillary electrophoresis/electrospray ionization-mass spectrometry (CE/ESI-MS) analysis of mixtures of small peptides, proteins, and tryptic digests of proteins. The effects of different experimental parameters on the performance of this CE/ESI-MS interface were studied. The distance of the in-capillary electrode from the CE outlet and the length of the electrode inside the capillary had no significant effects on the CE separation and ESI behavior under the experimental conditions used. However, significant enhancement of the sensitivity resulted from the use of narrower CE capillaries. Using a quadrupole mass spectrometer, an aminopropylsilane-coated capillary, and a wide scan mass-to-charge ratio range of 500–1400, detection limits of approximately 4, 1, and 0.6 fmol for cytochrome c and myoglobin were achieved for 75-, 50-, and 30-µm inner diameter capillaries, respectively. Approximately one order of magnitude lower detection limits were achieved under the multiple-ion monitoring mode. The application of the in-capillary electrode sheathless interface to real-world samples was demonstrated by CE/ESI-MS analysis of a human blood sample.  相似文献   

6.
A fast method for the generation of permanent hydrophilic capillary coatings for capillary electrophoresis (CE) is presented. Such interior coating is effected by treating the surface to be coated with a solution of glutaraldehyde as cross-linking agent followed by a solution of poly(vinyl alcohol) (PVA), which results in an immobilization of the polymer on the capillary surface. Applied for capillary zone electrophoresis (CZE) such capillaries coated with cross-linked PVA exhibit excellent separation performance of adsorptive analytes like basic proteins due to the reduction of analyte-wall interactions. The long-term stability of cross-linked PVA coatings could be proved in very long series of CZE separations. More than 1000 repetitive CE separations of basic proteins were performed with stable absolute migration times relative standard deviation (RSD > 1.2%) and without loss of separation efficiency. Cross-linked PVA coatings exhibit a suppressed electroosmotic flow and excellent stability over a wide pH range.  相似文献   

7.
The usefulness of a noncovalent capillary coating consisting of two layers of oppositely charged polymers for the separation of peptides with capillary electrophoresis (CE) was studied. Capillaries were coated simply by subsequently flushing with solutions of 1% m/v Polybrene and 1% v/v poly(vinylsulfonate) (PVS) forming a bilayer, which showed to produce a strong and highly reproducible electroosmotic flow (EOF) at low pH. Using this coating in combination with a background electrolyte (BGE) containing sodium phosphate (pH 2.5) and 0.01% v/v PVS, initially broadened and overlapping peaks were obtained for some test peptides. By omitting the PVS from the BGE, the peak width and shape of the peptides improved resulting in baseline separation. A systematic study of the influence of the BGE composition showed that considerable further enhancement of the separation efficiency was achieved by increasing the ionic strength of the BGE. Using a BGE of 200 mM tris(hydroxymethyl)aminomethane (Tris)-phosphate (pH 2.5) plate numbers for the peptides were in the 300 000-600 000 range and the relative standard deviation of the peptide migration times was less then 0.3% (n = 5). The use of Tris-phosphate instead of sodium phosphate allowed the current to stay within acceptable limits when 30 kV was used as separation voltage. Overall, the bilayer coating showed a remarkable EOF repeatability, as well as long-term stability. Compared to bare fused-silica capillaries the intraday and interday repeatability of migration times was very favorable and coated capillaries could be used for over a month performing analyses with low and high ionic strength BGEs without any performance deterioration. The usefulness of the bilayer-coated capillaries for the analysis of positively charged peptides was demonstrated by the fast and efficient separation of various closely related enkephalins and the baseline separation of an isomeric peptide/peptoid couple exhibiting efficiencies of over 550 000 plates.  相似文献   

8.
The solution chemistry conditions necessary for optimum analysis of peptides by capillary zone electrophoresis (CZE)/electrospray ionization mass spectrometry and CZE electrospray ionization tandem mass spectrometry have been studied. To maximize the signal-to-noise ratio of the spectra it was found necessary to use acidic CZE buffers of low ionic strength. This not only increases the total ion current, but it also serves to fully protonate the peptides, minimizing the distribution of ion current across the ensemble of possible charge states. The use of acidic buffers protonates the peptides, which is advantageous for mass spectrometry and tandem mass spectrometry analysis, but is problematic with CZE when bare fused silica CZE columns are used. These conditions produce positively charged peptides, and negatively charged silanol moieties on the column wall, inducing adsorption of the positively charged peptides, thus causing zone broadening and a loss in separation efficiency. This problem was circumvented by the preparation of chemically modified CZE columns, which, when used with acidic CZE buffers, will have a positively charged inner column wall. The electrostatic repulsion between the positively charged peptides and the positively charged CZE column wall minimizes adsorption problems and facilitates high efficiency separations. Full-scan mass spectra were acquired from injections of as little as 160 fmols of test peptides, with CZE separation efficiencies of up to 250,000 theoretical plates.  相似文献   

9.
Capillary electrophoresis (CE) offers fast and high‐resolution separation of charged analytes from small injection volumes. Coupled to mass spectrometry (MS), it represents a powerful analytical technique providing (exact) mass information and enables molecular characterization based on fragmentation. Although hyphenation of CE and MS is not straightforward, much emphasis has been placed on enabling efficient ionization and user‐friendly coupling. Though several interfaces are now commercially available, research on more efficient and robust interfacing with nano‐electrospray ionization (ESI), matrix‐assisted laser desorption/ionization (MALDI) and inductively coupled plasma mass spectrometry (ICP) continues with considerable results. At the same time, CE‐MS has been used in many fields, predominantly for the analysis of proteins, peptides and metabolites. This review belongs to a series of regularly published articles, summarizing 248 articles covering the time between June 2016 and May 2018. Latest developments on hyphenation of CE with MS as well as instrumental developments such as two‐dimensional separation systems with MS detection are mentioned. Furthermore, applications of various CE‐modes including capillary zone electrophoresis (CZE), nonaqueous capillary electrophoresis (NACE), capillary gel electrophoresis (CGE) and capillary isoelectric focusing (CIEF) coupled to MS in biological, pharmaceutical and environmental research are summarized.  相似文献   

10.
In this study, positively charged alkylaminosilyl monomers were used to modify the inner surface of fused silica capillaries, which subsequently were employed in capillary electrophoresis (CE) and capillary electrochromatography (CEC). The obtained surfaces yield a reversed electroosmotic flow (EOF) and have varying carbon chain lengths, that interact with the analytes and give chromatographic retention. The coating procedure is very simple and fast. The performance of the modified capillaries was evaluated regarding pH influence on EOF and chromatographic interactions. The experiments were conducted with UV and mass spectrometry (MS) and applied to the separation of various neuropeptides. The derivatized surfaces showed a linear (R(2) approximately 0.99) pH dependence with isoelectric points (pI) at 8.6-8.8. Rapid separations of peptide standards and a protein digest with efficiencies as high as 5 x 10(5) plates/m were performed.  相似文献   

11.
We have made a rigorous assessment of the ability of capillary electrophoresis to resolve peptide diastereomers through its application to the separation of a series of synthetic 18-residue, amphipathic alpha-helical monomeric peptide analogues, where a single site in the centre of the hydrophobic face of the alpha-helix is substituted by 19 L- or D-amino acids. Such L- and D-peptide pairs have the same mass-to-charge ratio, amino acid sequence and intrinsic hydrophobicity, varying only in the stereochemistry of one residue. CE approaches assessed in their ability to separate diastereomeric peptide pairs included capillary zone electrophoresis (uncoated capillary), micellar electrokinetic chromatography (uncoated capillary in the presence of 3-[(3-cholamidopropyl)dimethylammonio]-1-propanesulfonate, CHAPS), open-tubular capillary electrochromatography (C(8)-coated capillary in the presence of 25% 2,2,2-trifluoroethanol (TFE) or 25% ethanol). Overall, the OT-CEC methods were the most effective at separating the most peptide pairs, particularly for those containing hydrophilic side chains. However, the MEKC approach proved most effective for separation of peptide pairs containing hydrophobic or aromatic side chains.  相似文献   

12.
The use of capillary electrochromatography (CEC) for the separation by isocratic elution of synthetic peptides, proteins as well as the tryptic digest of cytochrome c has been demonstrated. The monolithic porous stationary phase was prepared from silanized fused-silica capillaries of 75 microm I.D. by in situ copolymerization of vinylbenzyl chloride and ethylene glycol dimethacrylate in the presence of propanol and formamide as the porogens. The chloromethyl groups at the surface of the porous monolith were reacted with N,N-dimethylbutylamine to form a positively charged chromatographic surface with fixed n-butyl chains. Results of studies on the influence of temperature and mobile phase composition on the retention and selectivity of separation by CEC demonstrated the feasibility of rapid polypeptide analysis and tryptic mapping at elevated temperature with high resolution and efficiency. Typically the chromatography of a tryptic digest of cytochrome c took about 5 min at 55 degrees C and 75 kV/m with hydro-organic mobile phases containing acetonitrile in 50 mM phosphate buffer, pH 2.5. For peptides and proteins plots of logarithmic k'cec against acetonitrile concentration were nonlinear, whereas Arrhenius plots for the mobilities were nearly linear. Comparison of the separation of such samples under conditions of CEC and capillary zone electrophoresis (CZE) indicates that the mechanism of separation in CEC is unique and leads to a chromatographic profile different from that obtained by CZE.  相似文献   

13.
Joule heating, arising from the electric current passing through the capillary, causes many undesired effects in CE that ultimately result in band broadening. The use of narrow‐bore capillaries helps to solve this problem as smaller cross‐sectional area results in decreased Joule heating and the rate of heat dissipation is increased by the larger surface‐to‐volume ratio. Issues arising from such small capillaries, such as poor detection sensitivity, low loading capacity and high flow‐induced backpressure (complicating capillary loading) can be avoided by using a bundle of small capillaries operating simultaneously that share buffer reservoirs. Microstructured fibres, originally designed as waveguides in the telecommunication industry, are essentially a bundle of parallel ~5 μm id channels that extend the length of a fibre having otherwise similar dimensions to conventional CE capillaries. This work presents the use of microstructured fibres for CZE, taking advantage of their relatively high surface‐to‐volume ratio and the small individual size of each channel to effect highly efficient separations, particularly for dye‐labelled peptides.  相似文献   

14.
The specificity and rate of cleavage of adrenocorticotrophic hormone (ACTH) peptide bonds by endoproteinase Arg C were analyzed using capillary electrophoresis (CE) and reversed-phase (C18) high-performance liquid chromatography (HPLC). Acidic cleavage products were readily resolved by CE in uncoated capillaries using low ionic strength electrolytes. However, products predicted to have a net positive charge greater than 2 or more than 4 positively charged groups per peptide did not migrate out from the capillary at low ionic strength. Addition of salts and zwitterions to the electrolyte decreased capillary-peptide interactions such that all of the ACTH peptides examined were eluted with high efficiency separation by CE. Commercially obtained endoproteinase Arg C preparations exhibited peptidase activity at Lys-15-Lys16 and at Lys16-Arg17 in addition to the expected cleavage at Arg-X bonds. ACTH peptide bond cleavage rates for Arg8-Trp9, Arg17-Arg-18, Lys15-Lys16, and Lys16-Arg17 were 1.46, 0.096, 0.57, and 0.029 mumol min-1 mg-1 respectively. CE separations generally exhibited better resolution and were accomplished in shorter times than C18 HPLC separations. These properties make CE a particularly appropriate method for kinetic analysis of proteolytic enzyme action on peptide substrates.  相似文献   

15.
An on-line affinity selection method using a polymeric monolithic support is proposed for the retention of histidine-containing peptides and their subsequent separation by capillary zone electrophoresis (CZE). Monolithic capillary columns were prepared in fused-silica capillaries of 150 mum inner diameter (ID) by ionizing radiation-initiated in situ polymerization and cross-linking of diethylene glycol dimethacrylate and glycidyl methacrylate, and chemically modified with iminodiacetic acid (IDA) and copper ion. Monolithic microextractors were coupled on-line near the inlet of the separation capillary (fused-silica capillary, 75 mum ID x 28 cm from the microextractor to the detector). Model peptide mixtures of histidine-containing and histidine-noncontaining peptides were assessed. Peptides were released from the sorbent by a 5 mM imidazole solution and then separated by CZE with ultraviolet detection. Relative standard deviation values for migration times and corrected peak areas were found to be lower than 5.8 and 10.5%, respectively. IDA-Cu(II) ion modified monolithic microextractors showed a chromatographic behavior and could be reused at least 25 times. The use of monolithic supports proved to be an advantageous alternative to packed particles for the preparation of microextractors.  相似文献   

16.
Fourteen azodyes containing one to five acidic groups were separated by capillary zone electrophoresis (CZE). The effects of the pH and beta-cyclodextrin additive to the background electrolyte on the separation of sulphonated azodyes were investigated. The effects of the working conditions significantly differ in non-coated fused silica capillaries and in capillaries coated with polyacrylamide. Splitting of the zones of metal-complex dyes was observed in polyacrylamide coated capillaries and the background electrolyte with 10 mmol/L beta-cyclodextrin, due to the separation of stereoisomeric forms of the dyes, which were separated for the first time using CE. Relations between the structure of the sulphonated azodyes and the electrophoretic mobilities are discussed. Naphthalene mono- to tetrasulphonic acids were used as the standards for the calibration of migration scale of the analysed dyes.  相似文献   

17.
Generation 2 to generation 5 poly(amidoamine) (PAMAM) dendrimers having different terminal functionalities were analyzed by capillary electrophoresis (CE). Polyacrylamide gel electrophoresis was also used to assess the composition of the individual generations for comparison with the CE results. Separation of PAMAMs can be accomplished by either using uncoated silica or silanized silica capillaries, although reproducibility is poor using the uncoated silica capillary. To improve run-to-run reproducibility, silanized capillary was used and various internal standards were also tested. Relative and normalized migration times of primary amine terminated PAMAM dendrimers were then determined using 2,3-diaminopyridine (2,3-DAP) as an internal standard. Using silanized capillaries and internal standards, the relative and normalized migration times are fully reproducible and comparable between runs. Apparent dimensionless electrophoretic mobilities were determined and the results were compared to theoretical calculations. It is concluded that for PAMAMs a complex separation mechanism has to be considered in CE, where the movement of the ions is due to the electric field, but the separation is rather the consequence of the adsorption/desorption equilibria on the capillary wall ("electrokinetic capillary chromatography"). The described method may be used for quality control and may serve as an effective technique to analyze polycationic PAMAM dendrimers and their derivatives with different surface modifications.  相似文献   

18.
An integrated platform consisting of protein separation by CIEF with monolithic immobilized pH gradient (M‐IPG), on‐line digestion by trypsin‐based immobilized enzyme microreactor (trypsin‐IMER), and peptide separation by CZE was established. In such a platform, a tee unit was used not only to connect M‐IPG CIEF column and trypsin‐IMER, but also to supply adjustment buffer to improve the compatibility of protein separation and digestion. Another interface was made by a Teflon tube with a nick to couple IMER and CZE via a short capillary, which was immerged in a centrifuge tube filled with 20 mmol/L glutamic acid, to exchange protein digests buffer and keep electric contact for peptide separation. By such a platform, under the optimal conditions, a mixture of ribonuclease A, myoglobin and BSA was separated into 12 fractions by M‐IPG CIEF, followed by on‐line digestion by trypsin‐IMER and peptide separation by CZE. Many peaks of tryptic peptides, corresponding to different proteins, were observed with high UV signals, indicating the excellent performance of such an integrated system. We hope that the CE‐based on‐line platform developed herein would provide another powerful alternative for an integrated analysis of proteins.  相似文献   

19.
Due to the short light path of the capillaries, the CE detection limit based on concentration, is far less than that of HPLC and not sufficient for many practical applications. Several methods, based on different electrophoretic maneuvers, can concentrate the sample (stack) easily on the capillary before the separation step of capillary zone electrophoresis (CZE). These methods incorporate different types of discontinuous buffers as the means for invoking different velocities to the same analyte molecules to produce a sharpening of the band (stacking). In CZE, these buffers can be often very simple such as sample dilution or adding to the sample a high concentration of a fast mobility ion. However, in other applications these buffers can be as complicated as those required for isotachophoresis. Stacking can often yield a concentration factor of 5-30-fold, which can improve greatly in CZE the detection limits bringing them very close to those of HPLC. Different methods of stacking, the importance of discontinuous buffers and the different mechanism for concentration on the capillary are reviewed here. As there is a need for more practical applications, there will be more methods devised for stacking in CZE.  相似文献   

20.
The capillary walls of fused-silica capillary electrophoresis (CE) columns were modified with a thin film of polyaniline (PANI), providing open-tubular columns with a stable coating containing aromatic groups and amine functionalities. Fast and efficient separations were observed for small bioactive peptides under acidic conditions on PANI-coated columns. The mechanism of separation is based on hydrophobic interactions between the analytes and the polymeric matrix. Good reproducibility was observed from run-to-run. Due to the simple derivatization procedure, method flexibility, the uniformity of the coating and its stability, conjugated polymers could find practical application in capillary zone electrophoresis (CZE) separations.  相似文献   