首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
To further clarify the role of dopant solvent in proton transfer in atmospheric pressure photoionization (APPI), we employ ultrahigh-resolution FT-ICR mass analysis to identify M(+*), [M + H](+), [M - H](-), and [M + D](+) species in toluene or perdeuterotoluene for an equimolar mixture of five pyrrolic and pyridinic nitrogen heterocyclic model compounds, as well as for a complex organic mixture (Canadian Athabasca bitumen middle distillate). In the petroleum sample, the protons in the [M + H](+) species originate primarily from other components of the mixture itself, rather than from the toluene dopant. In contrast to electrospray ionization, in which basic (e.g., pyridinic) species protonate to form [M + H](+) positive ions and acidic (e.g., pyrrolic) species deprotonate to form [M - H](-) negative ions, APPI generates ions from both basic and acidic species in a single positive-ion mass spectrum. Ultrahigh-resolution mass analysis (in this work, m/Deltam(50%) = 500,000, in which Deltam(50%) is the mass spectral peak full width at half-maximum peak height) is needed to distinguish various close mass doublets: (13)C versus (12)CH (4.5 mDa), (13)CH versus (12)CD (2.9 mDa), and H(2) versus D (1.5 mDa).  相似文献   

2.
Fast gradient high performance liquid chromatography (HPLC) has been combined with a commercially available Fourier transform ion cyclotron resonance (FTICR) mass spectrometer for the routine and high performance analysis of mixtures. With this combination we were able to separate and detect, under high mass accuracy conditions, a six-component drug mixture in less than 5 minutes. The fast gradients described are now possible due to the development of mechanically robust, ultra pure silica packing materials, which allow relatively high flow rates (ca. 1 mL/min for a 2 mm diameter column). For the six compounds present in the model mixture, relative mass errors of less than 1 ppm were obtained (based on an external calibration) providing sufficient mass accuracy to make unequivocal assignments of empirical formulae. Preliminary results of fast gradient HPLC/FTICR-MS/MS are also shown for the same six-component mixture. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

3.
Tandem quadrupole Fourier transform mass spectrometry is shown to be a practical technique for the determination of molecular weights. Samples in the mass range up to 6000 daltons can be routinely analyzed at the 0.1–1.0 pmol level. Ions indicative of molecular weight are generated by particle bombardment, transmitted to and trapped inside a superconducting magnetic field and mass analyzed. Additional structural information is obtained by exposing the trapped ions to photons generated by an argon fluoride excimer laser to effect laser photodissociation. Sequence analysis of oligopeptides fractionated by liquid chromatography is discussed. Application of the technique to the structural chacterization of proteins isolated by two-dimensional gel electrophoresis is also demonstrated.  相似文献   

4.
High temperature gas chromatography and gas chromatography/mass spectrometry are used in the characterization of complex natural mixtures of permethylated oligosaccharides released from proteins or lipids. The high resolution allows separation of isomeric compounds and the mass range extends to oligosac-charides around molecular mass 2000 daltons or 10 sugar residues for isomalto-oligosaccharides. The mass spectra of permethylated oligosaccharide alditols from mucin glycopeptides are very informative and the approach allows a simple and rapid characterization of these complex components.  相似文献   

5.
This study investigated the feasibility of analyzing a full range of ambient volatile organic compounds (VOCs) from C(3) to C(12) using gas chromatograph mass spectrometry (GC/MS) coupled with thermal desorption. Two columns were used: a PLOT column separated compounds lighter than C(6) and a DB-1 column separated C(6)-C(12) compounds. An innovative heart-cut technique based on the Deans switch was configured to combine the two column outflows at the ends of the columns before entering the MS. To prevent the resolved peaks from re-converging after combining, two techniques were attempted (hold-up vs. back-flush) to achieve the intended "delayed" elution of heavier components. Thus, the resulting chromatogram covering the full range of VOCs is a combination of two separate elutions, with the heavier section following the lighter section. With the hold-up method, band-broadening inevitably occurred for the delayed C(6)-C(7) DB-1 compounds while the light compounds eluted from the PLOT column. This broadening problem resulted in peak tailing that was largely alleviated by adding a re-focusing stage while the DB-1 compounds were back-flushed, and this modified technique is referred to as the back-flush method. With this modification, the separation of the C(6)-C(7) compounds improved dramatically, as revealed by the decrease in peak asymmetry (As) and increase in resolution. Linearity and precision for these peaks also improved, yielding R(2) and RSD values better than 0.9990 and 2.8%, respectively.  相似文献   

6.
7.
The experimental Fourier transform ion cyclotron resonance (FT/ICR) frequency range has been extended to 107 MHz. We report the observation of FT/ICR signals from electron-ionized species of mass-to-charge ratio 8, 7, 6, 5, 4, 3, 2, and 1 μ per elementary charge. We show that moderately high charge states of atomic ions (e.g., N3+) are easily generated and detected. Several applications for high-frequency FT/ICR mass spectrometry are proposed and discussed.  相似文献   

8.
A new technique for manipulating the kinetic energy distribution of electrospray ions that arrive at a Fourier transform ion cyclotron resonance trapped-ion cell is presented. Narrow kinetic energy distributions can complicate the selection of appropriate trapping conditions for electrospray ions and introduce charge discrimination in resulting mass spectra. Modulation of the applied skimmer potential controllably broadens the kinetic energy distribution, which improves the reproducibility of acquired spectra and eliminates charge discrimination. Mass spectra of horse heart cytochrome c are presented to demonstrate the utility of the technique. For example, applied static skimmer potentials of 12 and 9 V yield charge state distributions ranging from [M+19H]+19 to [M+12H]+12 and [M+15H]+15 to [M+7H]+7, respectively. A 12 ± 2 V, 100-Hz modulation of the skimmer potential yields an electrospray spectrum with charge states that range from [M+19H]+19 to [M+7H]+7, which is more representative of the source distribution.  相似文献   

9.
A differentially pumped external secondary ion source for Fourier transform mass spectrometry is described. Installation does not interfere with other experiments such as laser desorption or photodissociation. Spectra of cesium iodide clusters (with ions up to m/z 8187), polyethylene glycol 1000, and histidine from both glycerol and dithiothreitol-dithioerythritol matrices are reported. The ion with m/z 156 from histidine was recorded with mass resolution of 160,000.  相似文献   

10.
For structural studies of proteins and their complexes, chemical cross-linking combined with mass spectrometry presents a promising strategy to obtain structural data of protein interfaces from low quantities of proteins within a short time. We explore the use of isotope-labeled cross-linkers in combination with Fourier transform ion cyclotron resonance (FTICR) mass spectrometry for a more efficient identification of cross-linker containing species. For our studies, we chose the calcium-independent complex between calmodulin and a 25-amino acid peptide from the C-terminal region of adenylyl cyclase 8 containing an "IQ-like motif." Cross-linking reactions between calmodulin and the peptide were performed in the absence of calcium using the amine-reactive, isotope-labeled (d0 and d4) cross-linkers BS3 (bis[sulfosuccinimidyl]suberate) and BS2G (bis[sulfosuccinimidyl]glutarate). Tryptic in-gel digestion of excised gel bands from covalently cross-linked complexes resulted in complicated peptide mixtures, which were analyzed by nano-HPLC/nano-ESI-FTICR mass spectrometry. In cases where more than one reactive functional group, e.g., amine groups of lysine residues, is present in a sequence stretch, MS/MS analysis is a prerequisite for unambiguously identifying the modified residues. MS/MS experiments revealed two lysine residues in the central alpha-helix of calmodulin as well as three lysine residues both in the C-terminal and N-terminal lobes of calmodulin to be cross-linked with one single lysine residue of the adenylyl cyclase 8 peptide. Further cross-linking studies will have to be conducted to propose a structural model for the calmodulin/peptide complex, which is formed in the absence of calcium. The combination of using isotope-labeled cross-linkers, determining the accurate mass of intact cross-linked products, and verifying the amino acid sequences of cross-linked species by MS/MS presents a convenient approach that offers the perspective to obtain structural data of protein assemblies within a few days.  相似文献   

11.
In this work, solid-phase microextraction (SPME) has been applied as an alternative for the selective extraction of 3 polybrominated diphenyl ethers (PBDEs), 2,2',4,4'-tetrabromodiphenyl ether (PBDE-47); 2,2',4,4',5-pentabromodiphenyl ether (PBDE-99); and 2,2',4,4',6-pentabromodiphenyl ether (PBDE-100), and 2 alkylphenols, 4-tert-OP and 4-NP, prior to their analysis by gas chromatography/mass spectrometry (GC/MS). The advantages of this technique are mainly its simplicity, cost-effectiveness, and time-saving sample preparation, as well as being a solvent-free technique. With the aim of optimizing the conditions for an efficient extraction of the studied compounds, different fiber coatings and the main parameters affecting the extraction procedure have been evaluated. The results obtained showed a good linearity in the range of concentrations investigated, and adequate relative standard deviation values were found according to the range accepted for SPME. Recovery values were in the range of 78-108%, and good detection and quantitation limits at ppt levels were obtained for both methods, allowing the determination of the selected compounds in samples at trace levels. The results obtained clearly show the potential of SPME for efficient concentration of the target compounds and also demonstrate the reliability of this extraction technique for their GC/MS analysis.  相似文献   

12.
A novel multi-analyte method for the simultaneous determination of 46 compounds of environmental concern, most of them belonging to the category of persistent organic pollutants, was developed using high-performance liquid chromatography and the results were compared to those obtained by gas chromatography. This study was performed in perspective of a cumulative exposure assessment of substances of health concern in environments where high levels, relatively to airborne particulate matter, can be found. The target compounds included polychlorinated biphenyls, brominated flame–retardants and derivatives of polycyclic aromatic hydrocarbons.

The multi-analyte method was evaluated in air particulate matter in terms of reproducibility, linearity, recovery, limits of detection and quantification and matrix effect. The recovery was above 70% for all the analytes, whereas limits of quantification ranged between 23 and 390 pg?m?3 in liquid chromatography and less than ten times in gas chromatography–mass spectrometry.

Matrix effect was generally negligible for both the techniques, except the case of the detection of oxygenated derivatives of polycyclic aromatic hydrocarbons by gas chromatography.

In order to demonstrate the efficacy and to assess the method performances (accuracy and precision), both the techniques were applied to standard reference materials, and the results were compared, discussing their advantages and disadvantages.

The method was finally applied to a real sample of indoor airborne particulate matter with aerodynamic diameter ≤4 μm (PM4).

We demonstrated that liquid chromatography was the only technique able to analyse the 46 compounds, including thermally degradable ones, with a single chromatographic run without derivatisation steps. On the other hand, gas chromatography still presents higher sensitivity for the detection of some of the investigated compounds. This study can be considered only explorative and further improvements can be expected with new-generation LC-MS instruments (10–100 times more sensitive).  相似文献   

13.
Analytical methods that are used for the detection and identification of chemicals related to the Chemical Weapons Convention in complex organic solutions were developed. A matrix modified by the addition of complex diesel oil background compounds and interferences was used for the development of a gas chromatography-mass spectrometry or gas chromatography-tandem mass spectrometry (GC-MS or GC-MS/MS) method for unambiguous identification of the scheduled chemicals. Co-elution of diethyl N,N-dimethylphosphoramidate and ethyl N,N-dimethylphosphoramidocyanidate, which are not separated by GC, was identified by GC-MS. Although GC-MS can identify the compounds, GC-MS/MS identification has greater accuracy and sensitivity in the case of complex matrixes. Four scheduled chemicals were accurately and selectively identified against numerous interfering substances by GC-MS/MS. The fragmentation chemistry of these compounds using MS/MS analysis was investigated.  相似文献   

14.
Gas-phase hydrogen/deuterium exchange of D2O with [M+H]+ ions of angiotensin II, angiotensin I, [Sar1]-angiotensin II, bradykinin, des-Arg1-bradykinin, des-Arg9-bradykinin, luteinizing hormone releasing hormone (LH-RH), and substance P has been examined by Fourier transform ion cyclotron resonance mass spectrometry at 9.4 tesla. Because the FTICR dynamic range increases quadratically with magnetic field, parent ions from a mixture of several peptides may be confined simultaneously for long periods at high pressure (e. g., 1 h at 1×10?5 torr) without quadrupolar axialization (and its attendant ion heating), for faster data acquisition and better controlled comparisons between different peptides. A high magnetic field also facilitates stored waveform inverse Fourier transform (SWIFT) isolation of monoisotopic [M+H]+ parent ions, so that deuterium incorporation patterns may be determined directly without the need for isotopic distribution deconvolution. Finally, a higher magnetic field provides for a greatly extending trapping period, for measurement of much slower rates. Angiotensin I, angiotensin II, and [Sar1]-angiotensin II are found to undergo a rapid exchange. Angiotensin II and [Sar1]-angiotensin II exhibit multiple deuterium uptake distributions, corresponding to multiple gas-phase conformations. In contrast, substance P exchanges slowly and LH-RH displays no observable exchange. Comparison of the relative H/D exchange rates for bradykinin and its des-Arg-derivatives supports the hypothesis that bradykinin adopts a folded gas-phase conformation that unfolds upon removal of either terminal arginine residue.  相似文献   

15.
Journal of The American Society for Mass Spectrometry - A series of methylmethacylate/butylacrylate, methylmethacrylate/styrene, and poly-(ethylene glycol)/poly(propylene glycol) copolymers were...  相似文献   

16.
Analytical Chemistry Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee, USA Ultraviolet matrix-assisted laser desorption can be used to enhance formation of [M + H]+, [M + Na]+, and [M + K)+ ions from small peptides for Fourier transform mass spectrometry (FTMS). In accord with laser desorption (LD) time-of-flight experiments, matrices such as nicotinic acid and 2-pyrazinecarboxylic acid exhibit strong enhancement effects (i.e., formation of abundant protonated and cationized molecules for the analyte with virtually no fragment ions) for 266 nm LD/FTMS, whereas pyrazinedicarboxylic acid provides no matrix enhancement at this wavelength. Both sinapinic acid and coumarin-120 provide strong matrix enhancement effects for the 355-nm LD of peptides. For the small peptides examined in this study, no significant differences in the abundance of fragment ions were observed between the 266- and 355-nm wavelengths. Matrix-assisted LD/FTMS is useful for the generation and characterization of ions corresponding to protonated and cationized molecules from virtually all biological compounds with molecular weights up to 2000. The lack of observation of biological ions with m/ z > 2500 may be related to inefficient trapping of these laser-desorbed ions or instrumental detection limitations of FTMS and is under further investigation.  相似文献   

17.
18.
Addition of silver nitrate to nonpolar hydrocarbon polymer solutions prior to their analysis by laser desorption Fourier transform mass spectrometry is shown to allow efficient silver ion chemical ionization. High-quality mass spectra are thus obtained for polymers, such as polystyrene, polyisoprene, polybutadiene, and polyethylene, that previously failed to yield useful mass spectra using conventional laser desorption. Accurate mass measurement experiments and isotopic ratios verify that the spectra are those of silver-attached oligomer ion distributions. Mass measurement errors for complete oligomer distributions average between 3 and 12 ppm for oligomers with masses between 400 and 6000 D whereas unit mass resolution is maintained throughout the entire spectral range.  相似文献   

19.
A method for determining accurate relative molecular masses and elemental compositions of several non-volatile and thermally labile organic compounds in the source cell was established. The experimental sequence included laser desorption/electron impact Fourier transform mass spectrometry and direct-mode observation over a narrow mass range. Perfluorotributylamine was used as internal calibrant. Errors were about 1 ppm.  相似文献   

20.
In this paper, we compare the current separation power of comprehensive two-dimensional gas chromatography (GCxGC) with the potential separation power of GC-mass spectrometry (GC-MS) systems. Using simulated data, we may envisage a GC-MS contour plot, that can be compared with a GCxGC chromatogram. Real examples are used to demonstrate the current potential of the two techniques in the field of hydrocarbon analysis. As a separation technique for complex hydrocarbon mixtures, GCxGC is currently about as powerful as GC-MS is potentially powerful. GC-MS has not reached its potential separation power in this area, because a universal, soft ionization method does not exist. The greatest advantage of GCxGC is, however, its potential for quantitative analysis. Because flame-ionisation detection can be used, quantitative analysis by GCxGC is much more robust, reliable and reproducible.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号