首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The effect of sodiumcarboxymethyl cellulose (Na-CMC) on the corrosion behavior of mild steel in 1.0 mol·L-1 HCl solution has been investigated by using weight loss (WL) measurement, potentiodynamic polarization, linear polarization resistance (LPR), and electrochemical impedance spectroscopy (EIS) methods. These results showed that the inhibition efficiency of Na-CMC increased with increasing the inhibitor concentration. Potentiodynamic polarization studies revealed that the Na-CMC was a mixed type inhibitor in 1.0 mol·L-1 HCl. The adsorption of the inhibitor on mild steel surface has been found to obey the Langmuir isotherm. The effect of temperature on the corrosion behavior of mild steel in 1.0 mol·L -1 HCl with addition of 0.04% of Na-CMC has been studied in the temperature range of 298-328 K. The associated apparent activation energy (E*a) of corrosion reaction has been determined. Scanning electron microscopy (SEM) has been applied to investigate the surface morphology of mild steel in the absence and presence of the inhibitor molecules.  相似文献   

2.
The effect of sodium carboxymethyl cellulose (Na-CMC) on the corrosion behavior of mild steel in 1.0 mol·L-1 HCl solution has been investigated by using weight loss (WL) measurement, potentiodynamic polarization, linear polarization resistance (LPR), and electrochemical impedance spectroscopy (EIS) methods. These results showed that the inhibition efficiency of Na-CMC increased with increasing the inhibitor concentration. Potentiodynamic polarization studies revealed that the Na-CMC was a mixed type inhibitor in 1.0 mol·L-1 HCl. The adsorption of the inhibitor on mild steel surface has been found to obey the Langmuir isotherm. The effect of temperature on the corrosion behavior of mild steel in 1.0 mol·L-1 HCl with addition of 0.04% of Na-CMC has been studied in the temperature range of 298-328 K. The associated apparent activation energy (E*a ) of corrosion reaction has been determined. Scanning electron microscopy (SEM) has been applied to investigate the surface morphology of mild steel in the absence and presence of the inhibitor molecules.  相似文献   

3.
The inhibition effect of cetyl trimethyl ammonium bromide (CTAB) on the corrosion of mild steel in 1.0 mol L?1 hydrochloric acid (HCl) has been studied at different temperatures (25–60°C) by weight loss and potentiodynamic polarization methods. The results reveal that CTAB behaves as an effective inhibitor in 1.0 mol L?1 HCl, and the inhibition efficiency increases with the inhibitor concentration. Polarization curves show that CTAB is a mixed-type inhibitor in hydrochloric acid. The results obtained from weight loss and polarizations are in good agreement. The effect of immersion time on corrosion inhibition has also been examined and is discussed. The adsorption of inhibitor on mild steel surface obeys the Langmuir adsorption isotherm equation. Thermodynamic parameters have been obtained by adsorption theory. The inhibition effect is satisfactorily explained by the parameters.  相似文献   

4.
嘧啶衍生物对钢在盐酸溶液中的缓蚀作用   总被引:1,自引:0,他引:1  
李向红  谢小光 《物理化学学报》2013,29(10):2221-2231
采用失重法、动电位极化曲线、电化学阻抗谱(EIS)、量子化学计算研究了两种嘧啶衍生物(2-羟基嘧啶(HP)和2-巯基嘧啶(MP))在1.0-5.0 mol·L-1 HCl溶液中对冷轧钢(CRS)的缓蚀作用. 结果表明: HP和MP在1.0 mol·L-1 HCl溶液中对冷轧钢具有良好的缓蚀作用, 且在钢表面的吸附符合Langmuir吸附等温式. 缓蚀率随缓蚀剂浓度的增加而增大, 但随盐酸浓度的增加而减小.求出了相应的吸附热力学参数(吸附平衡常数(K),吸附自由能(ΔG0))和腐蚀动力学参数(表观活化能(Ea)、指前因子(A)、腐蚀速率常数(k)、动力学常数(B)), 并根据这些参数讨论了缓蚀作用机理. 动电位极化曲线表明, MP和HP均为混合抑制型缓蚀剂; EIS谱呈单一容抗弧,电荷转移电阻随缓蚀剂浓度的增加而增大. 两种嘧啶化合物的缓蚀率排序为MP>HP. 量子化学计算结果表明,MP比HP更具吸附活性,缓蚀性能的理论计算和实验结果相一致.  相似文献   

5.
A flow injection on-line coprecipitation preconcentration system with diethyldithiocarbamate (DDTC) chelate of copper used as the coprecipitate carrier was coupled with flame atomic absorption spectrometry (FAAS) for the determination of trace silver. Silver was on-line coprecipitated with DDTC-Cu(II) in 0.5 moL · L−1HCl, and the precipitate was collected in a knotted reactor. The precipitate was then dissolved by isobutyl methyl ketone and transported directly into the nebulizer–burner system of a flame atomic absorption spectrometer. A detection limit (3ς) of 0.6 μg · L−1was achieved for a loading period of 30 s, a relative standard derivation of 2.0% was obtained for 11 determinations of 20 μg · L−1Ag(I). Interference-free levels were 10 mg · L−1for Cd2+, 50 mg · L−1for Cu2+, 50 mg · L−1for Mn2+, 25 mg · L−1for Ni2+, 100 mg · L−1for Pb2+, 50 mg · L−1for Zn2+, 500 mg · L−1for Fe3+, and 2000 mg · L−1for Fe2+reduced from Fe3+by ascorbic acid. The developed method has been successfully applied to the determination of trace amount of silver in geological samples.  相似文献   

6.
A poly-amidosulfonic acid and multi-wall carbon nanotubes composite (PASA/MWNTs) modified electrode has been constructed by electropolymerization on glassy carbon electrode (GCE). The electrochemical behaviors of hydroquinone (HQ) and catechol (CC) were investigated using cyclic and differential pulse voltammetries (DPVs) at the prepared electrode. Separation of the reductive peak potentials for HQ and CC was about 120 mV in pH 6.0 phosphate buffer solution (PBS), which makes it suitable for simultaneous determination of these compounds. In the presence of 1.0 × 10−4 mol L−1 isomer, the reductive peak currents of DPV are proportional to the concentration of HQ in the range of 6.0 × 10−6 to 4.0 × 10−4 mol L−1, and to that of CC in the range of 6.0 × 10−6 to 7.0 × 10−4 mol L−1. When simultaneously changing the concentration of both HQ and CC, the linear concentration range of HQ (or CC) is 6.0 × 10−6 to 1.0 × 10−4 mol L−1 (or 6.0 × 10−6 to 1.8 × 10−4 mol L−1), and the corresponding detection limits are 1.0 × 10−6 mol L−1. The proposed method has been applied to simultaneous determination of HQ and catechol in water sample, and the results are satisfactory.  相似文献   

7.
This paper reports a poly-Nile Blue (PNB) sensing film based electrochemical sensor and the application in food analysis as a possible alternative for electrochemical detection of nitrite. The PNB-modified electrode in the sensor was prepared by in situ electropolymerization of Nile Blue at a prepolarized glassy carbon (GC) electrode and then characterized by cyclic voltammetry (CV) and pulse voltammetry in phosphate buffer (pH 7.1). Several key operational parameters affecting the electrochemical response of PNB sensing film were examined and optimized, such as polarization time, PNB film thickness and electrolyte pH values. As the electroactive PNB sensing film provides plenty of active sites for anodic oxidation of nitrite, the nitrite sensor exhibited high performance including high sensitivity, low detection limit, simple operation and good stability at the optimized conditions. The nitrite sensor revealed good linear behavior in the concentration range from 5.0 × 10−7 mol L−1 to 1.0 × 10−4 mol L−1 for the quantitative analysis of nitrite anion with a limit of detection of 1.0 × 10−7 mol L−1. Finally, the application in food analysis using sausage as testing samples was investigated and the results were consistent with those obtained by standard spectrophotometric method.  相似文献   

8.
A novel taurine modified glassy carbon electrode was prepared by electropolymerization method. The electrochemical behaviors of epinephrine (EP) and dopamine (DA) at the modified electrode were studied by cyclic voltammetry. The modified electrode exhibited enhanced sensitivity and excellent electrochemical discrimination to DA and EP. The cathodic peaks of the two species were well-separated with a potential difference of about 390 mV, so the poly(taurine) modified electrode was used for simultaneous voltammetric measurement of EP and DA by differential pulse voltammetry. Under the optimum conditions, the cathodic peak currents were linear to concentrations of EP and DA in the range of 2.0 × 10−6 to 6.0 × 10−4 mol L−1 and 1.0 × 10−6 to 8.0 × 10−4 mol L−1, respectively. The detection limits for EP and DA were 3.0 × 10−7 and 1.0 × 10−7 mol L−1, respectively. Because the oxidation of ascorbic acid (AA) is an irreversible reaction at modified electrode, the interference of AA for determining EP and DA was eliminated. The modified electrode has been satisfactorily used for the simultaneous determination of EP and DA in pharmaceutical injections.  相似文献   

9.
CuS nanotubes (NTs) made up of nanoparticles were successfully prepared in large quantities in an O/W microemulsion system under low temperature. Based on the characteristics of synchronous fluorescence spectroscopy (SFS), a new method with high sensitivity and selectivity was developed for rapid determination of silver ion with functional copper sulphide (CuS) nanotubes as a fluorescence probe. Under optimal conditions, functional copper sulphide displayed a calibration response for silver ion over a wide concentration range from 1.0 × 10−10 to 1.0 × 10−8 mol L−1. The limit of detection was 0.5 × 10−10 mol L−1 and the relative standard deviation of eight replicate measurements for the highest concentration (1 × 10−8 mol L−1) was 3%. Compared with several fluorescence methods, the proposed method had a wider linear range and improved the sensitivity. Furthermore, the concentration dependence of the synchronous fluorescence intensity is effectively described by a Langmuir-type binding isotherm.  相似文献   

10.
A new approach for decreasing the detection limit for a copper(II) ion-selective electrode (ISE) is presented. The ISE is designed using salicylidine-functionalized polysiloxane in carbon paste. This work describes the attempts to develop the electrode and measurements of its characteristics. The new type of renewable three-dimensional chemically modified electrode could be used in a pH range of 2.3–5.4, and its detection limit is 2.7 × 10−8 mol L−1 (1.2 μg L−1). This sensor exhibits a good Nernstian slope of 29.4 ± 0.5 mV/decade in a wide linear concentration range of 2.3 × 10−7 to 1.0 × 10−3 mol L−1 of Cu(II). It has a short response time (8 s) and noticeably high selectivity over other Cu(II) selective electrodes. Finally, it was satisfactorily used as an indicator electrode in complexometric titration with EDTA and determination of copper(II) in miscellaneous samples such as urine and various water samples.  相似文献   

11.
Electrochemical measurements were performed to investigate the effectiveness and adsorption behaviour of aminobiphenyl (Aph) and 2-(3-hydroxybenzylideneamino)biphenyl (Aph-S), as corrosion inhibitors for mild steel (MS) in 0.5 M HCl solution. Potentiodynamic polarization, linear polarization resistance (LP) and electrochemical impedance spectroscopy (EIS) techniques were applied to study the metal corrosion behaviour in the absence and presence of different concentrations of Aph and Aph-S. In order to gain more information about adsorption mechanism the AC impedance technique was used to evaluate the potential of zero charge (PZC) from polarization resistance (Rp) versus voltage (E) plot. Potentiodynamic polarization measurements showed that Aph act as cathodic type inhibitor where as Aph-S act mixed type. The inhibition efficiency (IE%) increases with increasing concentration of compounds and reached 92.6% for Aph and 97.2% for Aph-S at 5 × 10−3 M. Double layer capacitance (Cdl) and polarization resistance (Rp) values are derived from Nyquist plots obtained from AC impedance studies. The experimental data fit Langmuir isotherm for both Aph and Aph-S, and from the adsorption isotherm some thermodynamic data for the adsorption processes are calculated and discussed. The effect of exposure time on the corrosion behaviour of mild steel in the absence and presence of inhibitor over 168 h was also studied.  相似文献   

12.
Interfacial behavior of cysteine (Cys) between mild steel and sulfuric acid solution as a corrosion inhibitor has been studied with electrochemical AC (alternating current) and DC (direct current) techniques at (25.0±0.1) °C. The AC impedance results were evaluated using equivalent circuits in which a constant phase element (CPE) has been replaced with double layer capacitance (Cdl) to represent the frequency distribution of experimental data. Changes in impedance parameters (charge transfer resistance and double layer capacitance) indicated that cysteine molecules acted by accumulating at the metal/solution interface. The fractional coverage of the metal surface () was determined using AC impedance results and it was found that the adsorption of cysteine on the mild steel surface followed a Langmuir isotherm model with a standard free energy of adsorption (ΔG0ads) of −35.1 kJ·mol−1.To clarify the type of interaction between mild steel surface and cysteine molecules with a molecular orbital approach, electronic properties, such as, the highest occupied molecular orbital (HOMO) energy, the lowest unoccupied molecular orbital (LUMO) energy, and the frontier molecular orbital coefficients have been calculated. Energy gaps for the interaction of mild steel surface and cysteine molecules (ELUMO FeEHOMO Cys and ELUMO CysEHOMO Fe) were used to determine whether cysteine molecules acted as electron donors or electron acceptors when they interacted with the mild steel surface. The local reactivity was evaluated through the condensed Fukui indices. Theoretical calculations were carried out using the density functional theory (DFT) at B3LYP level with the 6-311++G(d,p) basis set for all atoms by Gaussian 03W program.  相似文献   

13.
Herein, a novel electrochemical method was developed for the determination of tryptophan based on the poly(4-aminobenzoic acid) film modified glassy carbon electrode (GCE). The electrochemical behaviors of tryptophan at the modified electrode were investigated. It was found that the oxidation peak current of tryptophan at the modified GCE was greatly improved compared with that at the bare GCE. The effects of supporting electrolyte, pH value, scan rate, accumulation potential and time were examined. The oxidation peak current of tryptophan was proportional to its concentration over the range from 1.0 × 10−6 to 1.0 × 10−4 mol L−1. The limit of detection was evaluated to be 2.0 × 10−7 mol L−1. The proposed method was sensitive and simple. It was successfully employed to determine tryptophan in pharmaceutical samples.  相似文献   

14.
A new simple, selective and sensitive fluorescence quenching method was developed to determine cationic surfactants with the 9-anthracenecarboxylic acid (ACA). The fluorescence intensity of ACA was decreased by addition of trace amounts of cationic surfactants. Under optimum conditions, the ratio of fluorescence intensity in the absence and presence of cationic surfactants was proportional to the concentration of cationic surfactants over the range of 0.3–4.5 × 10−5 mol L−1 for cetylpyridinium chloride (CPC) and 0.4–6.0 × 10−5 mol L−1 for cetyl trimethyl-ammonium bromide (CTAB). The detection limits are 1.0 × 10−6 mol L−1 for CPC and 1.2 × 10−6 mol L−1 for CTAB, respectively. Based on this approach, this paper presents a new quantitative method for cationic surfactants assay.  相似文献   

15.
A new, rapid, sensitive, non-extraction batch, and flow injection spectrophotometric method for the determination of cationic surfactants (CSs) such as cetyltrimethyl ammonium bromide (CTAB), tetra-n-butyl ammonium chloride (TBAC) and cetylpyridinium chloride (CPC) is proposed. The method is based on the interaction of cationic surfactants with eriochrome black-T to form an ion-association complex. This complex has strong absorbance at 708 nm. The effects of chemical parameters and FIA variables on the determination of cationic surfactants were studied in detail, especially for CTAB. Under optimum conditions, the two linear calibration ranges of the method are 3.0 × 10−6 to 5.0 × 10−3 mol L−1 CTAB, CPB and DTAB for the batch spectrophotometric method and 2.0 × 10−6 to 2.0 × 10−4 mol L−1 CTAB, CPB and TBC for the flow injection spectrophotometric method. The sample throughput was 35 ± 5 samples h−1 at room temperature. The relative standard deviations for 10 replicates of analysis of (2.0, 0.6 and 0.2) × 10−4 mol L−1 CTAB were 1.2, 1.3, and 0.8%, respectively. In addition, the influence of potential interfering substances on the determination of cationic surfactants was studied. The proposed method is simple and rapid, using no toxic organic solvents. It was applied to the determination of trace CS in industrial wastewater with satisfactory results.  相似文献   

16.
A novel hybrid bifunctional sensing platform for simultaneous determination of NO and O2 has been developed, whereby hematite nanotubes are immobilized into the chitosan matrix onto a gold electrode (labeled as HeNTs-Chi/Au). The HeNTs distributed in porous-structured chitosan matrix not only offer abundant active sites for bifunctional sensing of NO and O2, but also facilitate oxidation of NO and reduction of O2 dramatically. Straight calibration curves are achieved in analyte concentration ranges of 5.0 × 10−8 to 1.25 × 10−6 mol L−1 for NO and 2.5 × 10−7 to 6.0 × 10−6 mol L−1 for O2. Also, the detection limits are low of 8.0 × 10−9 mol L−1 for NO and 5.0 × 10−8 mol L−1 for O2. Such an efficient bifunctional sensor for NO and O2 offers great potential in quantitation of NO levels in biological and medical systems, since NO level is highly regulated by various reactive oxygen species.  相似文献   

17.
The effect of betanin (2,6-pyridinedicarboxylic acid, 4-(2-(2-carboxy-5-(beta-D-glucopyr-anosyloxy)-2,3-dihydro-6-hydroxy-1H-indol-1-yl)ethenyl)-2,3-dihydro-(S-(R*,R*))) on the corrosion inhibition of mild steel has been investigated in 1 M HCl solution. Weight loss method, potentiodynamic polarization, and electrochemical impedance spectroscopy techniques were applied to study the mild steel corrosion behavior in the absence and presence of different concentrations of betanin under the influence of various experimental conditions. The results obtained showed that betanin is a good “green” inhibitor for mild steel in 1 M HCl solution. Scanning electron microscopy observations of the steel surface confirmed the protective role of the inhibitor. The polarization curves showed that betanin behaves mainly as a mixed-type inhibitor. Maximum inhibition efficiency (98%) is obtained at betanin concentrations of 0.01 M. The results obtained from weight loss, polarization, and impedance measurements are in good agreement.  相似文献   

18.
Tianqing Liu   《Acta Physico》2008,24(4):625-632
Effects of Triton X-100 on the properties of hemoglobin (Hb) and on the controlled release of ribavirin were studied using the methods of UV-Vis spectrum, fluorescence spectrum, zeta potential, conductivity, high-performance liquid chromatographic (HPLC), and image morphology in Hb/ribavirin/H2O system. With the increase of concentration of Triton X-100 in the system, the intrinsic fluorescence intensity, synchronous fluorescence intensity, fluorescence polarization, zeta potential, and morphology of Hb all changed gradually, and the ribavirin located on the Hb surface was dissociated and released out. When the concentration of Triton X-100 was higher than 1×10−5 mol·L−1, the stronger interaction of Triton X-100 with Hb was predominant. Hb was unfolded and denaturized. A little Triton X-100 can protect Hb from the effects of ribavirin.  相似文献   

19.
Abbas MN  Radwan AA 《Talanta》2008,74(5):1113-1121
A potentiometric lipoate-selective sensor based on mercuric lipoate ion-pair as a membrane carrier is reported. The electrode was prepared by coating the membrane solution containing PVC, plasticizer, and carrier on the surface of graphite electrode. Influences of the membrane composition, pH, and possible interfering anions were investigated on the response properties of the electrode. The sensor exhibits significantly enhanced response toward lipoate ions over the concentration range 1 × 10−7 mol L−1 to 1 × 10−2 mol L−1 with a lower detection limit of (LDL) of 9 × 10−8 mol L−1 and a slope of −29.4 mV decade−1, with S.D. of the slope is 0.214 mV. Fast and stable response, good reproducibility, long-term stability, applicability over a pH range of 8.0–9.5 is demonstrated. The sensor has a response time of ≤12 s and can be used for at least 6 weeks without any considerable divergence in its potential response. The proposed electrode shows good discrimination of lipoate from several inorganic and organic anions. The CGE was used in flow injection potentiometry (FIP) and resulted in well defined peaks for lipoate ions with stable baseline, excellent reproducibility and reasonable sampling rate of 30 injections per hour. The proposed sensor has been applied for the direct and FI potentiometric determination of LA in pharmaceutical preparations and urine; and has been also utilized as an indicator electrode for the potentiometric titration of LA.  相似文献   

20.
In this research, we first prepared poly (naphthylamine-formaldehyde) (PNAF) and then investigated its corrosion inhibition properties for polished steel specimens in 1 M HCl solution using chemical and electrochemical methods. Results showed that the PNAF could serve as an effective inhibitor of the corrosion of steel in hydrochloric acid media (the inhibition efficiency of this polymer at an optimum concentration of 100 mg L–1 was 99.9 %). The effect of temperatures on the corrosion behavior of steel was studied in the temperature ranging from 303 to 333 K for 1 M HCl at an optimum concentration of PNAF. It has been demonstrated that the adsorption behavior of this polymer on steel in 1 M HCl was found to obey Langmuir adsorption isotherm. Also, potentiodynamic polarization measurements showed that PNAF was a mixed type inhibitor.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号