首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A confirmatory method for the simultaneous determination of nandrolone (α and β) and trenbolone (α and β) in urine samples by liquid chromatography electrospray mass spectrometry (LC–MS-MS) was developed. After an enzymatic deconjugation, the urine was subjected to a one-step cleanup on a commercially available immunoaffinity chromatography cartridge. The analytes were detected by liquid chromatography–positive ion electrospray tandem mass spectrometry using deuterium labelled internal standards. The analytical procedure was applicable to bovine and swine urine samples. The procedure was validated as a quantitative confirmatory method according to the Commission Decision 2002/657/EC criteria. The results obtained showed that the method was suitable for statutory residues testing regarding the following performance characteristics: instrumental linearity, specificity, precision (repeatability and intra-laboratory reproducibility), recovery, decision limit (CCα), detection capability (CCβ) and ruggedness. The decision limits (CCα) obtained, were between 0.54 and 0.60 μg L−1; the recovery was above 64% for all the analytes. Repeatability was between 1.6% and 5.7% and within-laboratory reproducibility between 1.6% and 6.0% for all the steroids.  相似文献   

2.
A liquid chromatography tandem mass spectrometry (LC-MS/MS) confirmatory method for the simultaneous determination of nine corticosteroids in liver, including the four MRL compounds listed in Council Regulation 37/2010, was developed. After an enzymatic deconjugation and a solvent extraction of the liver tissue, the resulting solution was cleaned up through an SPE Oasis HLB cartridge. The analytes were then detected by liquid chromatography-negative-ion electrospray tandem mass spectrometry, using deuterium-labelled internal standards. The procedure was validated as a quantitative confirmatory method according to the Commission Decision 2002/657/EC criteria. The results showed that the method was suitable for statutory residue testing regarding the following performance characteristics: instrumental linearity, specificity, precision (repeatability and intra-laboratory reproducibility), recovery, decision limit (CCα), detection capability (CCβ) and ruggedness. All the corticosteroids can be detected at a concentration around 1 μg kg(-1); the recoveries were above 62% for all the analytes. Repeatability and reproducibility (within-laboratory reproducibility) for all the analytes were below 7.65% and 15.5%, respectively.  相似文献   

3.
The daily exposure to Ni from food, industrial processes, jewellery and coins makes the determination of Ni in human serum an important way to monitor the health status in non-occupationally exposed subjects. To this end, a method based on sector-field inductively coupled plasma mass spectrometry was developed and validated. The limits of detection (LoD) and quantification (LoQ), sensitivity, linearity range, trueness, repeatability, within-laboratory reproducibility and robustness were the considered issues of the validation process. The uncertainty associated with the measurements was also calculated, according to the Eurachem/Citac Guide. The method LoD and LoQ were 0.03 and 0.09 ng mL(-1), linearity was over two order of magnitude, trueness was -3.57%, and the repeatability and reproducibility showed relative standard deviations equal to 4.56% and 6.52%, respectively. The relative expanded uncertainty was 21.8% at the Ni levels found in the general population. The tentative reference value for serum Ni was 0.466 +/- 0.160 ng mL(-1) with a related interval between 0.226 and 1.026 ng mL(-1).  相似文献   

4.
With Regulation No. 1881/2006 the European Union fixed a maximum level for lead in milk. Consequently, there is the need to determine very low concentration of elements that may be present in milk in trace and ultratrace levels.Quadrupole inductively coupled plasma mass spectrometry (Q-ICP-MS) combined with dynamic reaction cell (DRC) has been widely employed in order to reach very low concentration, requested for this product. Furthermore, the DRC technology can help in removing polyatomic and argon-based interferences.In the present study, a method for the determination of arsenic, cadmium, chromium and lead in bovine milk was validated according to the EU common standards by means of DRC-ICP-MS. The main parameters evaluated in the validation were: recovery, repeatability and within-laboratory reproducibility, detection and quantification limits, linearity range and measurement uncertainty. Additionally, stability studies of the analyte in solution and ruggedness studies were carried out.The results obtained for limit of detection (LoD) and limit of quantification (LoQ) in μg kg−1 were respectively: As, 3.1 and 9.5; Cd, 0.08 and 0.24; Cr, 0.229 and 0.693; Pb, 0.5 and 1.5. While for the recovery: As, 91%; Cd 96%; Cr 99%; Pb, 95%. As for the repeatability: As, 7%; Cd, 3%; Cr, 6%; Pb, 4%.  相似文献   

5.
The Commission Decision 2002/657/EC is a fundamental reference document for the UE laboratories involved in residue analysis although its implementation has caused some difficulties in the requirements interpretation. In this work a pragmatic validation approach of a quantitative confirmatory method for the detection of 17-alpha-(alpha-NT) and 17-beta-19-nortestosterone (beta-NT) in bovine urine by gas chromatography mass spectrometry is proposed. The 19-nortestosterone is a banned anabolic steroid for which no minimum required performance limit (MRPL) has been laid down, therefore the limit reported in Italian Residue Monitoring Plan (2 microg L(-1)) has been considered the reference level to evaluate the method performances. The decision limit (CCalpha) and the detection capability (CCbeta) were obtained by the calibration curve procedure. The minimum required performance level (mrpl), which represents the starting concentration of the calibration curves, was preliminary fixed estimating the results dispersion of blank urine samples fortified at 2 microg L(-1) for each isomer. The found CCalpha and CCbeta were 1.5 and 1.9 microg L(-1) for alpha-NT and 1.2 and 1.4 microg L(-1) for beta-NT. The precision (repeatability and within-laboratory reproducibility) and recoveries were suitable for the investigated concentration range (1-3 microg L(-1)). Finally, the method ruggedness (minor and major changes) has been also demonstrated.  相似文献   

6.
A liquid chromatographic-tandem mass spectrometric multiresidue method for the simultaneous quantitative determination of the tetrahydroimidazole, levamisole and the benzimidazoles thiabendazole, oxfendazole, oxibendazole, albendazole, fenbendazole, febantel and triclabendazole in milk has been developed and validated. The anthelmintic residues were extracted with ethyl acetate. The liquid chromatographic separation was performed on a reversed-phase C18 column with gradient elution. The analytes were detected by tandem quadrupole mass spectrometry after positive electrospray ionisation by multiple reaction monitoring. The confirmatory method is very sensitive and each component can be detected at a residue level lower than 1 microgram/l. The method is validated according to the revised European Union requirements and all parameters were found conform the criteria. The evaluated parameters were linearity, specificity, stability, recovery, precision (repeatability and within-laboratory reproducibility) and analytical limits (detection limit, decision limit and detection capability). This analytical method is applied in the Belgian monitoring programme for classical anthelmintic veterinary drugs in raw farm cow's milk.  相似文献   

7.
Rodziewicz L  Zawadzka I 《Talanta》2008,75(3):846-850
A simple and rapid liquid chromatography tandem mass spectrometry (LC-ESI-MS-MS) confirmation method for the analysis chloramphenicol (CAP) in milk powder has been developed. Samples were extracted by using liquid-liquid extraction steps with ethyl acetate. Lipids were removed using hexsan. LC separation was achieved by using a Phenomenex Luna C-18 column and acetonitryle-water as a mobile phase. The mass spectrometer was operated in multiple reaction monitoring mode (MRM) with negative electro-spray interface (ESI-). The four transitions were monitored m/z 321-->257, 321-->194, 321-->152, 326-->157 (IS) and for quantification, the transition m/z 321-->152 was chosen. Validation of the method was done according to criteria of Decision Commission No 2002/657 EC. Validation includes the determination of specification, linearity, precision (within- and between-day), accuracy, decision limit (CC alpha) and detection capability (CC beta). Samples were fortified at CAP levels 0.30, 0.45 and 0.60 microg/kg with CAP-5d as internal standard. The precision within-day (RSD%) was lower than 12% and accuracy (RE%) ranged from -9.8 to -3.7%. The precision between-day (RSD%) was less than 15%. The limit of decision (CC alpha) and detection capability (CC beta) for milk powder 0.09 and 0.11 microg/kg. Value CC alpha and CC beta were calculated for the 321-->152 ion transition. This method has been successfully used for routine analysis.  相似文献   

8.
Determination of uranium in tap water by ICP-MS   总被引:23,自引:0,他引:23  
A fast and accurate procedure has been developed for the determination of uranium at microg L(-1) level in tap and mineral water. The method is based on the direct introduction of samples, without any chemical pre-treatment, into an inductively coupled plasma mass spectrometer (ICP-MS). Uranium was determined at the mass number 238 using Rh as internal standard. The method provides a limit of detection of 2 ng L(-1) and a good repeatability with relative standard deviation values (RSD) about 3% for five independent analyses of samples containing 73 microg L(-1) of uranium. Recovery percentage values found for the determination of uranium in spiked natural samples varied between 91% and 106%. Results obtained are comparable with those found by radiochemical methods for natural samples and of the same order for the certified content of a reference material, thus indicating the accuracy of the ICP-MS procedure without the need of using isotope dilution. A series of mineral and tap waters from different parts of Spain and Morocco were analysed.  相似文献   

9.
The presented method is able to analyse 47 substances of the antibiotic groups tetracyclines, quinolones, macrolides, sulfonamides, diamino-pyrimidine derivatives and lincosamides simultaneously in a single analytical run. Applying an in-house validation concept, the validation of the multi-method was successfully accomplished with a low number of experiments. Each substance was validated at least at the concentrations 0.5, 1.0 and 1.5 MRL (maximum residue limit), or respectively, at concentrations as low as possible for substances without MRL. The calculated relevant validation parameters, e.g. the decision limit CCα, the detection capability CCβ, the repeatability, the within-laboratory reproducibility and the recovery, are in an acceptable range and in compliance with the requirements of Commission Decision 2002/657/EC. A proficiency test and the implementation of the method by other laboratories were performed successfully.  相似文献   

10.
A simple, sensitive and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric method was developed and validated for the quantification of lacidipine in human plasma using its structural analogue, amlodipine, as internal standard (IS). The method involves a simple single-step liquid-liquid extraction with tert-butyl methyl ether. The analyte was chromatographed on an Xterra MS C(18) reversed-phase chromatographic column by isocratic elution with 20 mM ammonium acetate buffer-acetonitrile (10:90, v/v; pH 6) and analyzed by mass spectrometry in the multiple reaction monitoring mode. The precursor to product ion transitions of m/z 456.4 --> 354.4 and m/z 409.3 --> 238.3 were used to measure the analyte and the I.S., respectively. The chromatographic run time was 1.5 min and the weighted (1/x(2)) calibration curves were linear over the range 0.1-25 ng ml(-1). Lacidipine was sensitive to temperature in addition to light. The method was validated in terms of accuracy, precision, absolute recovery, freeze-thaw stability, bench-top stability and re-injection reproducibility. The limit of detection and lower limit of quantification in human plasma were 50 and 100 pg ml(-1), respectively. The within- and between-batch accuracy and precision were found to be well within acceptable limits (<15%). The analyte was stable after three freeze-thaw cycles (deviation <15%). The average absolute recoveries of lacidipine and amlodipine (IS) from spiked plasma samples were 51.1 +/- 1.3 and 50.3 +/- 4.9%, respectively. The assay method described here could be applied to study the pharmacokinetics of lacidipine.  相似文献   

11.
A simple and rapid method was developed for the simultaneous analysis of nine different pesticides in water samples by gas chromatography with mass spectrometry. A number of parameters that may affect the recovery of pesticides, such as the type of solid‐phase extraction cartridge, eluting solvent in single or combination and their volumes, and water pH value were investigated. It showed that three solid‐phase extraction cartridges (Strata‐X, Oasis HLB, and ENVI‐18) produced the greatest recovery while ethyl acetate/dichloromethane/acetone (45:10:45, 12 mL) followed by dichloromethane (6 mL) was efficient in eluting target pesticides from solid‐phase extraction cartridges. Different water pH values (4–9) did not show a significant effect on the pesticides recovery. The optimized method was verified by performing spiking experiments with a series of concentrations (0.002–10 μg/L) in waters, with good linearity, recovery, and reproducibility for most compounds. The limit of detection and limit of quantification of this optimized method were 0.01–2.01 and 0.02–6.71 ng/L, respectively, much lower than the European Union environmental quality standard for the pesticides (0.1 μg/L) in waters. The proposed method was further validated by participation in an interlaboratory trial. It was then subsequently applied to river waters from north‐east Scotland, UK, for the determination of the target pesticides.  相似文献   

12.
This paper describes a new method for the effective extraction, clean-up and chromatographic analysis of residues of four fluoroquinolones (ciprofloxacin, enrofloxacin, danofloxacin and sarafloxacin) in powdered infant formulae and follow-on preparations. Samples were reconstituted following the manufacturer's recommendations and treated with trichloroacetic acid in methanol 10% (w/v) for deproteinization. Two solid-phase extraction cartridges have been evaluated for sample clean-up and preconcentration, Strata Screen A and Strata X and the later provided the best recoveries for all the analytes tested. Chromatographic analysis has been carried out using a polar endcapped column (AQUA C(18)) and fluorescence detection, with lomefloxacin (LOME) as internal standard. Method validation has been performed according to European Commission Decision 2002/657/EC criteria, in terms of linearity, recovery, precision, specificity, decision limit (CC(alpha)) and detection capability (CC(beta)). Typical recoveries ranged between 70 and 110% at levels below and above the maximum residue limits of the target analytes in bovine milk, with an excellent intralab reproducibility (RSDs<7%). Matrix effects did not significantly affect method accuracy, as evidenced by analyzing different brands of milk. The method has been successfully applied to the analysis of 100 samples of infant and follow-on formulae of the Spanish and Latin American market, using LC-MS/MS as confirmatory technique.  相似文献   

13.
For analysis of uranium in urine determination of the isotope ratio and quantification were investigated by high-resolution inductively coupled plasma mass spectrometry (HR ICP-MS). The instrument used (ThermoFinniganMAT ELEMENT2) is a single-collector MS and, therefore, a stable sample-introduction system was chosen. The methodical set-up was optimized to achieve the best precision for both the isotope ratio and the total uranium concentration in the urine matrix.Three spiked urine samples from an European interlaboratory comparison were analyzed to determine the (235)U/(238)U isotope ratio. The ratio was found to be in the range 0.002116 to 0.007222, the latter being the natural uranium isotope ratio. The first ratio indicates the abundance of depleted uranium.The effect of storage conditions and the stability for the matrix urine were investigated by using "real-life" urine samples from unexposed persons in the Netherlands. For samples stored under refrigeration and acidified the results (range 0.8 to 5.3 ng L(-1) U) were in the normal fluctuation range whereas a decrease in uranium concentration was observed for samples stored at room temperature without acidification.  相似文献   

14.
The presented multi-method was developed for the confirmation of 37 antibiotic substances from the six antibiotic groups: macrolides, lincosamides, quinolones, tetracyclines, pleuromutilines and diamino-pyrimidine derivatives. All substances were analysed simultaneously in a single analytical run with the same procedure, including an extraction with buffer, a clean-up by solid-phase extraction, and the measurement by liquid chromatography tandem mass spectrometry in ESI+ mode. The method was validated on the basis of an in-house validation concept with factorial design by combination of seven factors to check the robustness in a concentration range of 5-50 μg kg(-1). The honeys used were of different types with regard to colour and origin. The values calculated for the validation parameters-decision limit CCα (range, 7.5-12.9 μg kg(-1)), detection capability CCβ (range, 9.4-19.9 μg kg(-1)), within-laboratory reproducibility RSD(wR) (<20% except for tulathromycin with 23.5% and tylvalosin with 21.4 %), repeatability RSD(r) (<20% except for tylvalosin with 21.1%), and recovery (range, 92-106%)-were acceptable and in agreement with the criteria of Commission Decision 2002/657/EC. The validation results showed that the method was applicable for the residue analysis of antibiotics in honey to substances with and without recommended concentrations, although some changes had been tested during validation to determine the robustness of the method.  相似文献   

15.
Uranium analysis in fish, echinoderms and shellfish samples collected in the north part of the Adriatic Sea is presented. The aim of the work was to evaluate uranium concentrations in samples of this kind, and also to investigate possible contamination from depleted uranium (DU) in consequence of the war operations previously conducted in that area. DU contamination was checked by measuring the (235)U/(238)U isotope ratio. The samples were dissolved according to the EPA 3052 procedure, and the determinations were performed by inductively coupled plasma mass spectrometry (ICP-MS), optimized in order to perform isotope ratio measurements with good precision. The method was validated by evaluating the recovery from spiked samples; results in the range 93-107% were obtained. The isotope ratio measurement was evaluated in terms of accuracy and precision by analyzing the certified reference materials IAEA 326 and GBW 07305, and good agreement with the certified values was obtained here also. The concentration of uranium was higher in invertebrate samples than in fish (0.3-2 microg/g of U vs. 0.05-0.1 microg/g, respectively). The isotope ratio measurements for all the samples gave values very similar to the natural ratio, permitting exclusion of the presence of DU.  相似文献   

16.
As is well known ammunitions containing depleted uranium (DU) were used by NATO during the Balkan war. The paper deals with the determination of uranium alpha emitting radiosotopes in Kosovo soils by chemical separation and alpha spectrometry. The samples were collected by CISAM (Centro Interforze Studi ed Applicazioni Militari, S. Piero a Grado, Livorno) in the period November 1999-April 2000. The DU distribution in soil appeared very disomogeneous; the isotope weight percentages for U-238, U-235 and U-234 resulted 99.76, 0.24 and 7.24.10(-4) respectively; consequently the activity distribution was 86.42%, 1.31%, 11.63% and the isotope ratios were 1.52.10(-2) and 0.134 for U-235/U-238 and U-234/U-238 showing clearly the presence of DU. A small peak at 4.49 MeV (U-236) in the alpha spectrum indicated that the used DU was the by-product of exhausted uranium reprocessing. In order to determine the chemical and physiological solubility of uranium a fractionation study was carried out by using the Tessier method: 55% of uranium showed a fair solubility, but 45% was solubilized only by 8 M HNO3.  相似文献   

17.
Krachler M  Burow M  Emons H 《The Analyst》1999,124(6):923-926
An analytical procedure for the reliable determination of Sb in digests of lipid-rich environmental matrices in the low ng l-1-range based on flow injection hydride generation atomic absorption spectrometry (FI-HG-AAS) has been developed. Prior to HG-AAS, aliquots (250 to 320 mg) of dry samples were mineralized with 3 ml nitric acid and 0.5 ml of each sulfuric and perchloric acids in open digestion vessels made of glassy carbon in a heating block. Procedure detection and quantification limits of a previously developed procedure for the determination of Sb in plant materials by FI-HG-AAS were decreased with respect to the lower Sb concentrations in animal tissues, the sensitivity of the instrumental response was increased, and the composition of the acid digestion mixture was re-optimized for lipid-rich samples. The accuracy and precision of the developed procedure was evaluated by the analysis of the two reference materials Bovine Liver 1577a and Pig Kidney CRM 186. These reference materials have been additionally spiked with appropriate amounts of Sb to obtain recovery data. The solution detection limit (3 sigma) in digested samples was 0.021 microgram l-1, the detection limit for the whole procedure based on the dry powders was 7 pg g-1, the method quantification limit for a reliable determination of Sb was 23 pg g-1. The reproducibility of repetitive measurements was 6.0% at 0.1 microgram Sb l-1 and 2.2% at 0.5 microgram Sb l-1. Calibration curves were linear from 0.05 to 3 micrograms Sb l-1. To demonstrate the suitability of the developed method, concentrations of Sb have been determined in pigeon eggs (approximately 2 ng Sb g-1), as well as in bream livers (approximately 4 ng g-1) and in deer livers (approximately 5 to 8 ng g-1) from animals living in remote and urban-industrialized areas of Germany, respectively.  相似文献   

18.
A sensitive and robust liquid chromatography–tandem mass spectrometry (LC-MS/MS) method allowing the rapid screening and confirmation of thyreostatic drugs in bovine blood plasma was developed and validated according to Commission Decision 2002/657/EC, chapter 3.1.3 “alternative validation”, by applying a matrix-comprehensive in-house validation concept. Decision limit CCα, detection capability CCβ, recovery, repeatability, within-laboratory reproducibility and the uncertainty of measurement were calculated. Furthermore, a factorial effect analysis was carried out to identify factors that have a significant influence on the method. Factors considered to be relevant for the method in routine analysis (e.g. operator, storage duration of the extracts before measurement, different cartridge lots and duration of sample preparation) were systematically varied on two levels during the validation study. Subsequently, the extent to which these factors influence the measurement results of the individual analytes was examined.  相似文献   

19.
An ultra-high performance liquid chromatography tandem mass spectrometry method was developed and validated for the sensitive determination and unambiguous confirmation of residues of per and polyfluorinated alkyl substances (PFAS) in breastmilk, retail milk and infant formulas following two sample preparation methods. Sample pre-treatment was carried out by a simplified QuEChERS method without requiring dSPE or any further clean-up. The method was validated in accordance with the requirements of Commission Decision 657/2002/EC with slight modifications. The method displayed good linearity with R2 ranging from 0.9843–0.9998 for all target PFAS. The recovery and within-laboratory reproducibility of the method (n = 63) were in the range 60–121% and 5–28%, respectively. The decision limit, detection capability and limit of quantitation ranged from 30–60 ng kg−1 to 40–100 ng kg−1 and 5–50 ng kg−1, respectively. Acceptable matrix effect values in the range −45–29% were obtained with uncertainty of measurement lower than 25% for all target PFAS. The method displays its suitability for the sensitive and high-throughput confirmatory analysis of C4–C14 PFAS in breastmilk, dairy milk and infant formulas.  相似文献   

20.
A single-laboratory validation is reported for an LC/MS/MS quantification of six brevetoxins in four matrixes (Greenshell mussel, eastern oyster, hard clam, and Pacific oyster). Recovery and precision data were collected from seven analytical batches using shellfish flesh at 0.05 mg/kg. Method recoveries and within-laboratory reproducibility ranged from 73 to 112%, with an RSD between 14 and 18% for brevetoxin-3, brevetoxin B5, brevetoxin B2, and S-desoxy brevetoxin B2. The recovery and within-laboratory reproducibility for brevetoxin-2 was 61%, with an RSD of 27%. Brevetoxin B1 gave an RSD of 12%, but no reference material was available and this toxin was only recorded in a hard clam sample naturally contaminated with brevetoxins. One naturally contaminated sample of each shellfish matrix, with brevetoxin levels ranging from 0.012 to 9.9 mg/kg, was tested in multiple batches, and the RSDs were similar to those for fortified samples at 0.05 mg/kg. Comparisons with limited data for the neurotoxic shellfish poisoning mouse bioassay for four naturally contaminated shellfish samples showed that the regulatory action limit of 0.8 mg/kg is conservative with respect to the bioassay regulatory limit of 20 mouse units/100 g.  相似文献   