首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
An integrated detection circuitry based on a lock-in amplifier was designed for contactless conductivity determination of heavy metals. Combined with a simple-structure electrophoresis microchip, the detection system is successfully utilized for the separation and determination of various heavy metals. The influences of the running buffer and detection conditions on the response of the detector have been investigated. Six millimole 2-morpholinoethanesulfonic acid + histidine were selected as buffer for its stable baseline and high sensitivity. The best signals were recorded with a frequency of 38 kHz and 20 V(pp). The results showed that Mn(2+), Cd(2+), Co(2+), and Cu(2+) can be successfully separated and detected within 100 s by our system. The detection limits for five heavy metals (Mn(2+), Pb(2+), Cd(2+), Co(2+), and Cu(2+)) were determined to range from about 0.7 to 5.4 μM. This microchip system performs a crucial step toward the realization of a simple, inexpensive, and portable analytical device for metal analysis.  相似文献   

2.
Law WS  Kubán P  Zhao JH  Li SF  Hauser PC 《Electrophoresis》2005,26(24):4648-4655
The separation and detection of commonly used preservatives (benzoate, sorbate) and vitamin C by both conventional CE and microchip electrophoresis with capacitively coupled contactless conductivity detection is presented. The separation was optimized by adjusting the pH-value of the buffer and the use of hydroxypropyl-beta-CD (HP-beta-CD) and CTAB as additives. For conventional CE, optimal separation conditions were achieved in a histidine/tartrate buffer at pH 6.5, containing 0.025% HP-beta-CD and 0.1 mM CTAB. LOD ranged from 0.5 to 3 mg/L (S/N = 3) and the RSDs for migration time and peak area were less than 0.1 and 2%, respectively. A considerable reduction of analysis time can be accomplished by using microchip electrophoresis without significant loss in sensitivity under optimal separation conditions. A histidine/tartrate buffer at pH 6.5, incorporating 0.06% HP-beta-CD and 0.25 mM CTAB, gave detection limits ranging between 3 and 10 mg/L and satisfactory reproducibilities of < or =0.4% for the migration time and < or =3.5% for the peak area. The methods developed are useful for the quantitative determination of food additives in real samples such as soft drinks and vitamin C tablets.  相似文献   

3.
A portable capillary electrophoretic system with contactless conductivity detection was used for fingerprint analysis of postblast explosive residues from commercial organic and improvised inorganic explosives on various surfaces (sand, concrete, metal witness plates). Simple extraction methods were developed for each of the surfaces for subsequent simultaneous capillary electrophoretic analysis of anions and cations. Dual‐opposite end injection principle was used for fast (<4 min) separation of 10 common anions and cations from postblast residues using an optimized separation electrolyte composed of 20 mM MES, 20 mM l ‐histidine, 30 μM CTAB and 2 mM 18‐crown‐6. The concentrations of all ions obtained from the electropherograms were subjected to principal component analysis to classify the tested explosives on all tested surfaces, resulting in distinct cluster formations that could be used to verify (each) type of the explosive.  相似文献   

4.
An optimized capacitively coupled contactless conductivity detector for microchip electophoresis is presented. The detector consists of a pair of top–bottom excitation electrodes and a pair of pickup electrodes disposed onto a very thin plastic microfluidic chip. The detection cell formed by the electrodes is completely encased and shielded in a metal housing. These approaches allow for the enhancement of signal coupling and extraction from the detection cell that result in an improved signal‐to‐noise‐ratio and detection sensitivity. The improved detector performance is illustrated by the electrophoretic separation of six cations (NH, K+, Ca2+, Na+, Mg2+, Li+) with a detection limit of approximately 0.3 μM and the analysis of the anions (Br?, Cl?, NO, NO, SO, F?) with a detection limit of about 0.15 μM. These LODs are significantly improved compared with previous reports using the conventional top–top electrode geometry. The developed system was applied to the analysis of ions in bottled drinking water samples.  相似文献   

5.
研究了用微芯片毛细管电泳非接触电导检测系统快速测定加替沙星注射液中加替沙星的方法。对缓冲液的类型、浓度、分离电压以及进样时间等因素进行了优化。最佳条件为:缓冲液5.0 mmol/L HAc,分离电压2.0 kV,进样时间15.0 s。在该条件下,可在1.0 min内实现加替沙星的快速含量测定。线性范围为4.0~150μg/mL,检出限为1.0μg/mL,加标回收率为95.7%~101%,可成功测定注射液中加替沙星的含量。  相似文献   

6.
A microfabricated thin glass chip for contactless conductivity detection in chip capillary electrophoresis is presented in this contribution. Injection and separation channels were photolithographed and chemically etched on the surface of substrate glass, which was bonded with a thin cover glass (100 μm) to construct a new microchip. The chip was placed over an independent contactless electrode plate. Owing to the thinness between channel and electrodes, comparatively low excitation voltage (20–110 V in Vp–p) and frequency (40–65 kHz) were suitable, and favorable signal could be obtained. This microchip capillary electrophoresis device was used in separation and detection of inorganic ions, amino acids and alkaloids in amoorcorn tree bark and golden thread in different buffer solutions. The detection limit of potassium ion was down to 10 μmol/L. The advantages of this microchip system exist in the relative independence between the microchip and the detection electrodes. It is convenient to the replacement of chip and other operations. Detection in different position of the channel would also be available.  相似文献   

7.
Kubán P  Hauser PC 《Electrophoresis》2004,25(20):3387-3397
A better understanding of the characteristics of the axial contactless conductivity cell could be obtained by carefully studying the effect of the cell geometry on its frequency behavior. A good fit between theoretical and experimental results shows that the axial contactless conductometric detector can effectively be described by the simplest possible equivalent circuitry consisting of a capacitor, resistor, and a second capacitor. The cell constant is largely defined by the length of the gap between the electrodes. The effective electrode size is thus not related to the dimensions of the real electrodes but more closely to the cross-sectional area of the internal diameter of the capillary. Typical experimental values of 20 MOmega and 0.1 pF were obtained for the resistance and capacitances, respectively, of a cell formed by a 2 mm gap between two 4 mm long electrodes fitted with a capillary of 50 microm ID. It could be shown that the diameter of the electrode is not critical and tight coupling of the electrodes to the outer wall of the capillary is not needed. The peak overshoot phenomenon, which has frequently been reported, is an artefact that can be minimized by optimizing the frequency for cell excitation. The frequency setting has to be optimized for each cell design, operational amplifier, electrolyte solution and capillary.  相似文献   

8.
Zhao J  Chen Z  Li X  Pan J 《Talanta》2011,85(5):2614-2619
A microfluidic chip manufactured from glass substrate and indium tin oxide (ITO) coated glass use for contactless conductivity detection was developed. The detecting electrodes were fabricated by screen-printing and chemical etching methods using an ITO-coated glass wafer. Then, the glass substrate containing separation channels was bonded with the bare side of the processed ITO-coated glass, thus producing an electrophoresis chip integrated with contactless conductivity detector. The prepared microchip displayed considerable stability and reproducibility. Sensitive response was obtained at optimal conditions (including the gap between electrodes, excitation frequency, and excitation voltage). The feasibility of this microfluidic device was examined by detection of inorganic ions, and further demonstrated by the quantification of aminopyrine and caffeine in a compound pharmaceutical. The two ingredients can be completely separated within 1 min. The detection limits were 8 μg mL−1 and 3 μg mL−1, respectively; with the correlation coefficient of 0.996-0.998 in the linear range from 10 μg mL−1 to 800 μg mL−1. The results have showed that the present method is sensitive, reliable and fast.  相似文献   

9.
A capillary electrophoresis (CE) instrument with capacitively coupled contactless conductivity detection (C4D) based on a sequential injection analysis (SIA) manifold was refined. Hydrodynamic injection was implemented to avoid a sampling bias by using a split-injection device based on a needle valve for precise adjustment. For safety and reliability, the integrity of the high voltage compartment at the detection end was fully maintained by implementing flushing of the high voltage interface through the capillary. With this set-up, extended fully automated monitoring applications are possible. The system was successfully tested in the field for the determination of the concentration levels of major inorganic cations and anions in a creek over a period of 5 days.  相似文献   

10.
The system comprises two flow injection-capillary electrophoresis interfaces into which the opposite ends of the separation capillary are inserted. The electrolyte solution flows through both interfaces by use of hydrostatic pressure. The injection of the samples into the electrolyte flow is accomplished by a rotary-type chromatographic valve at the grounded side and by a pinch-valve injector at the high-voltage side that provides sufficient isolation from the high electric field. The system allows a fully automated dual-injection sequence of samples from both capillary ends and simultaneous electrophoretic separation of anions and cations in the samples. The analytes are detected by a high-voltage contactless conductometric detector positioned approximately in the middle of the separation capillary. The parameters of the system were evaluated. The repeatability of the flow injection-capillary electrophoresis system for the simultaneous determination of anions and cations was evaluated for ten consecutive injections and relative standard deviation (RSD) values for peak areas were better than 1.0%. The sample throughput for total ionic analysis was estimated to be 25 samples per hour. The system was used for automated simultaneous analysis of anions and cations in various real samples. Using a short separation capillary, rapid total ionic analysis in less then 1 min is demonstrated.  相似文献   

11.
Kubán P  Hauser PC 《Electrophoresis》2004,25(20):3398-3405
The signal-to-noise ratio of a contactless conductivity detector for capillary electrophoresis was examined for different cell arrangements and operating parameters. The best signal-to-noise ratios, and hence the best detection limits, are obtained for frequencies which give highest sensitivity. Comparative experiments for three different excitation voltages (20, 100, and 200 V(pp)) showed that the best signal-to-noise ratios were achieved for the highest excitation voltage of 200 V(pp). Low conductivity of the background electrolyte solution is mandatory to obtain lowest noise levels, and also the improvement on applying high excitation voltages was best for the electrolyte solution with lowest conductivity. The diameter of the electrodes was found to have only a negligible effect, so that a tight fitting of the electrodes to the external diameter of the capillary is not necessary. A cell without shielding between the two electrodes showed significant direct coupling (stray capacitance) and lower signal-to-noise ratios for all experimental conditions used. A serious distortion of the peak shapes was also observed for this cell arrangement.  相似文献   

12.
A CE system featuring an array of 16 contactless conductivity detectors was constructed. The detectors were arranged along 70 cm length of a capillary with 100 cm total length and allow the monitoring of separation processes. As the detectors cannot be accommodated on a conventional commercial instrument, a purpose built set‐up employing a sequential injection manifold had to be employed for automation of the fluid handling. Conductivity measurements can be considered universal for electrophoresis and thus any changes in ionic composition can be monitored. The progress of the separation of Na+ and K+ is demonstrated. The potential of the system to the study of processes in CZE is shown in two examples. The first demonstrates the differences in the developments of peaks originating from a sample plug with a purely aqueous background to that of a plug containing the analyte ions in the buffer. The second example visualizes the opposite migration of cations and anions from a sample plug that had been placed in the middle of the capillary.  相似文献   

13.
The sensitivity of contactless conductivity detection to amino acids, peptides and proteins in CE was studied for BGE solutions of different pH values. The LOD and analytical characteristics were compared for acidic and basic conditions and better results were in most cases found for buffers of low pH values. Linear dynamic ranges varied between two orders of magnitude for amino acids and peptides and three orders of magnitude for larger proteins. The concentration detection limits were found to be between 1.2 and 7.5 microM for the amino acids tested and for the larger molecules they varied between 2.6 microM for leucine enkephalin and 0.2 microM for HSA when using a buffer at pH 2.1.  相似文献   

14.
A simple microchip CE method integrated with contactless conductivity detection was developed for the direct determination of partition coefficients of selected pharmaceuticals after phase distribution equilibrium. The equilibrium of distribution between two phases for four pharmaceuticals was performed using a 1‐octanol/water system and 1‐octanol/buffer system. During the concentration determination, several major factors affecting detection were investigated in detail for each pharmaceutical to optimize the detection sensitivity. In the optimal conditions, sufficient electrophoretic separation and sensitive detection for each target analyte can be achieved within 40 s. The two systems showed a pH‐dependent partition behavior. Moreover, the measured values showed excellent agreement with those obtained by the traditional shake‐flask method with HPLC–UV detection and literature reports, respectively. The developed method can be successfully applied to measure partition coefficient values of pharmaceuticals and requires much shorter analytical time compared to traditional methods.  相似文献   

15.
A new end-column ‘hybrid’ contactless conductivity detector for microchip capillary electrophoresis (CE) was developed. It is based on a “hybrid” arrangement where the receiving electrode is insulated by a thin layer of insulator and placed in the bulk solution of the detection reservoir of the chip, whereas the emitting electrode is in contact with the solution eluted from the channel outlet in a wall-jet arrangement. The favorable features of the new detector including the high sensitivity and low noise, can be attributed to both the direct contact of the ‘emitting’ electrode with the analyte solution as well as to the insulation of the detection electrode from the high DC currents in the electrophoretic circuit. Such arrangement provides a 10-fold sensitivity enhancement compared to currently used on-column contactless conductivity CE microchip detector as well as low values of noise and easy operation. The new design of the wall-jet conductivity detector was tested for separation of explosive-related methylammonium, ammonium, and sodium cations. The new detector design reconsiders the wall-jet arrangement for microchip conductivity detection in scope of improved peak symmetry, simplified study of inter-electrode distance, isolation of the electrodes, position of the wall-jet electrode to the separation channel, baseline stability and low limits of detection.  相似文献   

16.
Wu Y  Lin JM  Su R  Qu F  Cai Z 《Talanta》2004,64(2):338-344
An end-channel amperometric detector with a guide tube for working electrode was designed and integrated on a home-made glass microchip. The guide tube was directly patterned and fabricated at the end of the detection reservoir, which made the fixation and alignment of working electrode relatively easy. The fabrication was carried out in a two-step etching process. A 30 μm carbon fiber microdisk electrode and Pt cathode were also integrated onto the amperometric detector. The characteristics and primary performance of the home-made microchip capillary electrophoresis (MCCE) were investigated with neurotransmitters. The baseline separation of dopamine (DA), catechol (CA) and epinephrine (EP) was achieved within 80 s. Separation parameters such as injection time, buffer components, pH of the buffer were studied. Relative standard deviations of not more than 6.0% were obtained for both peak currents and migration times. Under the selected separation conditions, the response for DA was linear from 5 to 200 μM and from 20 to 800 μM for CA. The limits of detection of DA and CA were 0.51 and 2.9 μM, respectively (S/N=3).  相似文献   

17.
Capacitively coupled contactless conductivity detection (C4D) in the axial electrode configuration was introduced in 1998 as a quantification method for capillary electrophoresis. Its universality allows the detection of small inorganic ions as well as organic and biochemical species. Due to its robustness, minimal maintenance demands and low cost the popularity of this detector has been steadily growing. Applications have recently also been extended to other analytical methods such as ion chromatography, high-performance liquid chromatography and flow-injection analysis. C4D has also found use for detection on electrophoresis based lab-on-chip devices. Theoretical aspects of C4D in both the capillary and microchip electrophoresis format have been comprehensively investigated. Commercial devices are now available and the method can be considered a mature detection technique. In this article, the achievements in C4D for the time period between September 2004 and August 2007 are reviewed.  相似文献   

18.
Tanyanyiwa J  Hauser PC 《Electrophoresis》2004,25(17):3010-3016
The extension of contactless conductivity detection in electrophoresis to the determination of basic drugs is demonstrated using beta-adrenergic blocking agents (beta-blockers) and other physiologically active amines as examples. The high-voltage approach to conductivity detection was employed for conventional capillaries as well as microchip devices. Acidic buffers were used in all cases. A buffer consisting of 100 mM acetic acid and 1 mM histidine was deemed most optimal for the separation of six beta-blockers and best results for the analysis of the other amines were achieved with a 20 mM lactic acid buffer at low pH-value. The detection limits ranged from 0.06 to 5 microM. To demonstrate potential practical applications, a main component assay was conducted for three pharmaceutical formulations. On-chip, five pharmaceutical amines could be baseline-resolved in a 8 cm long microchannel in 90 s, albeit a reduced sensitivity and peak capacity compared to conventional capillary electrophoresis.  相似文献   

19.
Saccharides form one of the major constituents of biological macromolecules in living organisms. Many biological processes including protein folding, stability, immune response and receptor activation are regulated by glycosylation. In this work, we optimized a capillary electrophoresis method with capacitively coupled contactless conductivity detection for the separation of eight monosaccharides commonly found in glycoproteins, namely D-glucose, D-galactose, D-mannose, N-acetyl-D-glucosamine, N-acetyl-D-galactosamine, D-fucose, N-acetylneuraminic acid, and D-xylose. A highly alkaline solution of 50 mM sodium hydroxide, 22.5 mM disodium phosphate, and 0.2 mM CTAB (pH 12.4) was used as a background electrolyte in a 10 µm id capillary. To achieve baseline separation of all analytes, a counter-directional pressure of –270 kPa was applied during the separation. The limits of detection of our method were below 7 µg/ml (i.e., 1.5 pg or 1 mg/g protein) and the limits of quantification were below 22 µg/ml (i.e., 5 pg or 3 mg/g protein). As a proof of concept of our methodology, we performed an analysis of monosaccharides released from fetuin glycoprotein by acid hydrolysis. The results show that, when combined with an appropriate pre-concentration technique, the developed method can be used as a monosaccharide profiling tool in glycoproteomics and complement the routinely used LC-MS/MS analysis.  相似文献   

20.
The common sweeteners aspartame, cyclamate, saccharin and acesulfame K were determined by capillary electrophoresis with contactless conductivity detection. In order to obtain the best compromise between separation efficiency and analysis time hydrodynamic pumping was imposed during the electrophoresis run employing a sequential injection manifold based on a syringe pump. Band broadening was avoided by using capillaries of a narrow 10 μm internal diameter. The analyses were carried out in an aqueous running buffer consisting of 150 mM 2-(cyclohexylamino)ethanesulfonic acid and 400 mM tris(hydroxymethyl)aminomethane at pH 9.1 in order to render all analytes in the fully deprotonated anionic form. The use of surface modification to eliminate or reverse the electroosmotic flow was not necessary due to the superimposed bulk flow. The use of hydrodynamic pumping allowed easy optimization, either for fast separations (80 s) or low detection limits (6.5 μmol L−1, 5.0 μmol L−1, 4.0 μmol L−1 and 3.8 μmol L−1 for aspartame, cyclamate, saccharin and acesulfame K respectively, at a separation time of 190 s). The conditions for fast separations not only led to higher limits of detection but also to a narrower dynamic range. However, the settings can be changed readily between separations if needed. The four compounds were determined successfully in food samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号