1.
A novel flow-injection amperometric method was proposed for the sensitive and enzymeless determination of hydrogen peroxide based on its electrocatalytic reduction at a palladium nanoparticle-modified pretreated pencil graphite electrode in a laboratory-constructed electrochemical flow cell. Cyclic voltammograms of the unmodified and modified electrodes were recorded in pH 7.0 phosphate buffer containing 0.10 M KCl at a scan rate of 50?mV s?1 for the investigation of electrocatalytic reduction of hydrogen peroxide at the palladium nanoparticle-modified pretreated pencil graphite electrode. Cyclic voltammograms of the pretreated pencil graphite electrode revealed an irreversible oxidation peak and a weak reduction peak of hydrogen peroxide at +1100?mV and –450?mV vs. an Ag/AgCl/KCl saturated reference electrode. However, the reduction of hydrogen peroxide was observed at –100?mV with an increase in current in the cyclic voltammograms of the palladium nanoparticle-modified pretreated pencil graphite electrode compared to the unmodified electrode. These results indicate that the palladium nanoparticle-modified pretreated pencil graphite electrode exhibits efficient electrocatalytic activity for the reduction of hydrogen peroxide. A linear concentration range was obtained between .01 and 10.0?mM hydrogen peroxide with a detection limit of 3.0 µM from flow injection amperometric current–time curves recorded in pH 7.0 phosphate buffer at –100?mV and a 2.0?mL min?1 flow rate. The novelty of this work relies on its use of a laboratory-constructed flow cell constructed for the pencil graphite electrode using these inexpensive, disposable, and electrochemically reactive modified electrodes for the amperometric determination of hydrogen peroxide in a flow injection analysis system.  相似文献   

2.
A new H2O2 enzymeless sensor has been fabricated by incorporation of thionin onto multiwall carbon nanotubes (MWCNTs) modified glassy carbon electrode. First 50 μL of acetone solution containing dispersed MWCNTs was pipetted onto the surface of GC electrode, then, after solvent evaporations, the MWCNTs modified GC electrode was immersed into an aqueous solution of thionin (electroless deposition) for a short period of time <5–50 s. The adsorbed thin film of thionin was found to facilitate the reduction of hydrogen peroxide in the absence of peroxidase enzyme. Also the modified electrode shows excellent catalytic activity for oxygen reduction at reduced overpotential. The rotating modified electrode shows excellent analytical performance for amperometric determination of hydrogen peroxide, at reduced overpotentials. Typical calibration at ?0.3 V vs. reference electrode, Ag/AgCl/3 M KCl, shows a detection limit of 0.38 μM, a sensitivity of 11.5 nA/μM and a liner range from 20 μM to 3.0 mM of hydrogen peroxide. The glucose biosensor was fabricated by covering a thin film of sol–gel composite containing glucose oxides on the surface of thionin/MWCNTs modified GC electrode. The biosensor can be used successfully for selective detection of glucose based on the decreasing of cathodic peak current of oxygen. The detection limit, sensitivity and liner calibration rang were 1 μM, 18.3 μA/mM and 10 μM–6.0 mM, respectively. In addition biosensor can reach 90% of steady currents in about 3.0 s and interference effect of the electroactive existing species (ascorbic acid–uric acid and acetaminophen) is eliminated. The usefulness of biosensor for direct glucose quantification in human blood serum matrix is also discussed. This sensor can be used as an amperometric detector for monitoring oxidase based biosensors.  相似文献   

3.
《Electroanalysis》2006,18(3):259-266
In this paper, a new strategy for constructing a mediator‐type amperometric hydrogen peroxide (H2O2) microbiosensor was described. An electropolymerized thionine film (PTH) was deposited directly onto a gold electrode surface. The resulting redox film was extremely thin, adhered well onto a substrate (electrode), and had a highly cross‐linked network structure. Consequently, horseradish peroxidase (HRP) was successfully immobilized on nanometer‐sized Au colloids, which were supported by thiol‐tailed groups of 11‐mercaptoundecanoic acid (11‐MUA) monolayer covalently bound onto PTH film. With the aid of the PTH mediator, HRP‐labeled Au colloids microbiosensor displayed excellent electrocatalytical response to the reduction of H2O2. This matrix showed a biocompatible microenvironment for retaining the native activity of the covalent HRP and a very low mass transport barrier to the substrate, which provided a fast amperometric response to H2O2. The proposed H2O2 microbiosensor exhibited linear range of 3.5 μM–0.7 mM with a detection limit of 0.05 μM (S/N=3). The response showed a Michaelis‐Menten behavior at larger H2O2 concentrations. The KMapp value for the biosensors based on 24 nm Au colloids was found to be 47 μM, which demonstrated that HRP immobilized on Au colloids exhibited a high affinity to H2O2 with no loss of enzymatic activity. This microbiosensor possessed good analytical performance and storage stability.  相似文献   

4.
A novel recessed electrode is reported for amperometric detection of hydrogen peroxide and via glucose oxidase for the detection of glucose. The electrode utilised electrodeposited platinum over a gold wire surface, which proved to be an effective peroxide-detecting surface. Compared with a traditional exposed electrode surface, the recessed tip facilitated an extended linear range for glucose from 4 to over 14 mM. Bio-fouling, as assessed by exposure to bovine serum albumin, was also significantly reduced. Though response time at the recess was increased, it was within an acceptable range for physiological monitoring. Moreover, the recess enabled precise measurement of the hydrogen peroxide diffusion coefficient; this was based on a bipartite expression for the transient amperometric current at the recessed structure following a step change in ambient hydrogen peroxide concentration. An important aspect of the diffusion measurement was the curve fitting routine used to map on to the theoretical response curve.  相似文献   

5.
《Electroanalysis》2004,16(20):1711-1716
A glucose microbiosensor has been developed using electrochemical codeposition of glucose oxidase (GOx) along with MnO2 as mediator, onto a single carbon fiber microelectrode. A two‐step deposition of only MnO2 initially and then of MnO2 in the presence of GOx has been introduced to ensure appropriate activity of the mediator. Several parameters such as deposition potential and time, concentration levels etc. have been characterized and optimized. A thin Nafion film was applied as an immobilization/encapsulation and interference‐free protective layer. The proposed microbiosensor was employed as an amperometric glucose detector at pH 7.5 at an operating potential of +0.58 V (vs. Ag/AgCl). The microbiosensor is characterized by a well‐reproducible amperometric response, linear signal‐to‐glucose concentration range from 1.5 mmol L?1 to 15 mmol L?1, and a limit of detection (S/N=3) of 0.8 mmol L?1. The microbiosensor exhibits good stability over more than ten hours of continuous measurement.  相似文献   

6.
《Analytical letters》2012,45(12):2373-2389
ABSTRACT

The performance of a first generation glucose amperometric biosensor based on the entrapment of glucose oxidase (GOx) within a net of copper electrodeposited onto activated glassy carbon electrode, is described. The copper electrodeposited offers an efficient electrocatalytic activity towards the reduction of enzymatically-liberated hydrogen peroxide, allowing for a fast and sensitive glucose quantification. The influence of the electrodeposition conditions (pH, potential, time, copper salt and enzyme concentrations) on the response of the bioelectrode was evaluated from the amperometric signals of hydrogen peroxide and glucose. The combination of copper electrodeposition with a nation membrane allows an excellent selectivity towards easily oxidizable compounds such as uric and ascorbic acids at an operating potential of -0.050 V. The response is linear up to 2.0 × 10?2 M glucose, the detection limit being 1.2 × 10?3 M.  相似文献   

7.
This work reports on the performance of new glucose biosensors based on the combination of the electrocatalytic properties of metals and carbon nanotubes towards the reduction of hydrogen peroxide with the biocatalytic activity of glucose oxidase (GOx). The bioelectrodes were obtained by dispersing the metal particles, enzyme and multi-wall carbon nanotubes within a mineral oil binder. The strong electrocatalytic activity of copper and iridium towards the reduction of hydrogen peroxide has made possible an important improvement in the sensitivity for the determination of glucose compared to the carbon nanotube composite without metals. A highly sensitive and selective amperometric detection of glucose becomes possible at very low potentials (−0.100 V). The presence of the protein enables a better dispersion of the metals within the composite matrix, thus allowing an additional enhancement in the response to hydrogen peroxide. The influence of the amount of copper in the composite on the analytical performance of the bioelectrode is discussed. A biosensor containing 0.77% w/w Cu and 10.0% w/w GOx gave a fast response (10.0 s), a linear relationship between current and glucose concentration up to 1.20 × 10−2 M, and a detection limit of 2.0 × 10−5 M. A similar behavior was found for a carbon nanotube-composite electrode containing iridium.  相似文献   

8.
《Electroanalysis》2005,17(12):1103-1111
Reagentless biosensors sensitive to hydrogen peroxide have been developed and compared. These biosensors are comprised of a carbon paste electrode modified with horseradish peroxidase (HRP) and one phenothiazine (methylene blue), one phenoxazine (meldola's blue) or one phenazine (phenazine methosulfate) dye adsorbed on silica gel modified with niobium oxide (SN). The enzyme was immobilized onto the graphite powder by cross‐linking with glutaraldehyde and mixing with one of the electron transfer mediators (dyes) adsorbed on SN. The amperometric response was based on the electrocatalytic properties of the dye to mediate electrons, which were generated in the enzymatic reaction of hydrogen peroxide under catalysis of HRP. The dependence on the biosensor response in terms of pH, buffer, HRP amounts and applied potential was investigated. The best results were found with a biosensor containing methylene blue dye showing an excellent operational stability (around 92% of the activity was maintained after 300 determinations). The proposed biosensor also presented good sensitivity (32.87 nA cm?2 μmol?1 L) allowing hydrogen peroxide quantification at levels down to 0.52×10?6 mol L?1 an optimum response at pH 6.8 and at a potential of ?50 mV (vs. SCE) and showing a wide linear response range (from 1 to 700 μmol L?1 for hydrogen peroxide).  相似文献   

9.
《Analytical letters》2012,45(7):1215-1224
Abstract

A new amperometric biosensor for adenosine-5′-triphosphate (ATP) was designed using a platinum-dispersed carbon paste into which glycerol kinase and glycerol-3-phosphate oxidase were incorporated. The biosensor is based on the detection of hydrogen peroxide produced by the enzymatic reaction of ATP with glycerol and the subsequent oxidation of glycerol-3-phosphate. The use of the platinum-dispersed carbon paste electrode lowered the oxidation potential for hydrogen peroxide, permitting the sensitive detection of ATP at 0.4 V vs. Ag/AgCl. A linear response to ATP was observed in the concentration range of 1 x 10?5 to 2.5 x 10?3 M.

  相似文献   

10.
The amperometric response of hydrogen peroxide, ascorbic acid and paracetamol (which are known interferents in many enzymatic biosensors) have been studied at polyaniline (PANI) modified platinum electrodes in pH?7.0 buffer solution. Platinum electrodes covered with the films of electropolymerized PANI display reduced response both to hydrogen peroxide and paracetamol, depending on the thickness of the film. An almost 1.5 to 2.1-fold decrease in anodic current is observed both for peroxide and paracetamol in case of PANI films having a redox capacity ranging from 5 to 400 μC cm-2. Ascorbate, in contrast, causes an increase in current due to the electrocatalytic nature of this process. It is concluded that PANI coatings do not warrant an adequate discrimination between the analytes studied.  相似文献   

11.
Horseradish peroxidase, previously modified with 1‐adamantane moieties, was supramolecularly immobilized on gold electrodes coated with perthiolated β‐cyclodextrin. The functionalized electrode was employed for the construction of an amperometric biosensor device for hydrogen peroxide using 1 mM hydroquinone as electrochemical mediator. The biosensor exhibited a fast amperometric response (6 s) and a good linear response toward H2O2 concentration between 12 μM and 450 μM. The biosensor showed a sensitivity of 1.02 mA/M cm2, and a very low detection limit of 5 μM. The electrode retained 97% of its initial electrocatalytic activity after 30 days of storage at 4 0C in 50 mM sodium phosphate buffer, pH 7.0.  相似文献   

12.
《Analytical letters》2012,45(5):875-886
Abstract

Platinum nanowires (PtNW) were prepared by an electrodeposition strategy using nanopore alumina template. The nanowires prepared were dispersed in chitosan (CHIT) solution and stably immobilized onto the surface of glassy carbon electrode (GCE). The electrochemical behavior of PtNW‐modified electrode and its application to the electrocatalytic reduction of hydrogen peroxide (H2O2) are investigated. The modified electrode allows low potential detection of hydrogen peroxide with high sensitivity and fast response time. As an application example, the glucose oxidase was immobilized onto the surface of PtNW‐modified electrode through cross‐linking by glutaric dialdehyde. The detection of glucose was performed in phosphate buffer at –0.2 V. The resulting glucose biosensor exhibited a short response time (<8 s), with a linear range of 10?5?10?2 M and detection limit of 5×10?6 M.  相似文献   

13.
Diamond-like carbon (DLC) films are gaining big interest in electrochemistry research area. DLC electrodes made with different ratio of sp3/sp2 carbon hybridization or doped with different percentages of nickel were characterized electrochemically by cyclic voltammetry and by amperometric measurements towards hydrogen peroxide. SiCAr1 and SiCNi5% were chosen as sensitive transducers for the elaboration of amperometric glucose biosensors. Immobilization of glucose oxidase was carried out by cross-linking with glutaraldehyde. Measurements were made at a fixed potential + 1.0 V in 40 mM phosphate buffer pH 7.4. SiCAr1 seems to be more sensitive for glucose, 0.6875 μA/mM, than SiCNi5%, 0.3654 μA/mM. Detections limits were 20 μM and 30 μM, respectively. Apparent Michaelis-Menten constants were found around 3 mM. Forty-eight percent and 79% of the original response for 0.5 mM glucose remained after 10 days for both biosensors, respectively.  相似文献   

14.
An amperometric glucose biosensor was successfully developed by electrochemical polymerization of p-chlorophenol (4-CP) at a Pt electrode in the presence of glucose oxidase. The amperometric response of this biosensor to hydrogen peroxide, formed as the product of enzymatic reaction, was measured at a potential of 0.6 V (vs. SCE) in phosphate buffer solution. The performances of sensors, prepared at different monomer concentrations and polymerization potentials, were investigated in detail. The biosensor prepared under optimal conditions had a linear response to glucose ranging from 2.5 × 10–4 to 1.5 × 10–2 mol L–1 with a correlation coefficient of 0.997 and a response time of less than 2 s. Substrate selectivity of the polymer-based enzyme electrode was tested for coexisting interferents such as uric acid and ascorbic acid, and no discernible response was observed. After 90 days, the response of the biosensor remained almost unchanged, indicating very good stability.  相似文献   

15.
We illustrate how the use of heated electrodes enhances the performance of glucose biosensors based on amperometric detection of the glucose-oxidase generated hydrogen peroxide. Nafion is shown to be an excellent matrix to protect glucose-oxidase from thermal inactivation during the heating pulses. The influence of the electrode temperature upon the amperometric response is examined. Temperature pulse amperometry (TPA) has been used to obtain convenient peak-shaped analytical signals. Surprisingly, up to 67.5 °C, the activity of Nafion-entrapped glucose-oxidase is greatly enhanced (24-fold) by accelerated kinetics rather than decreased by thermal inactivation. Amperometric signals even at elevated temperatures are stable upon prolonged operation involving repetitive measurements. The linear calibration range is significantly extended.  相似文献   

16.
《Analytical letters》2012,45(5):903-911
Abstract

In this report, we describe the finding that bamboo‐structured carbon nanotubes (CNT) showed superior electrocatalytic activity toward hydrogen peroxide. The slope of the calibration curve for hydrogen peroxide obtained with the bamboo‐structured CNT paste electrode was more than 20 times as large as the slopes obtained with hollow‐structured CNT paste and glassy carbon electrodes at an operating potential of ?0.1 V, with no interfering reactions. Incorporation of glucose oxidase within the bamboo‐structured CNT paste electrode allows the selective detection of glucose in the presence of common interferents without using any permselective membranes. This excellent ability of the bamboo‐structured CNT paste electrode toward hydrogen peroxide is applicable to the development of other enzymatic biosensors.  相似文献   

17.
An amperometric sensor system, based on a repetitive double step potential method at a glassy carbon electrode, has been developed for the simultaneous measurement of hydrogen peroxide and oxygen concentrations. The current measured at a potential of –1 V (vs. Ag/AgCl/saturated Cl) corresponds to the sum of the reduction currents of hydrogen peroxide and dissolved oxygen. The current measured at –0.55 V (vs. Ag/AgCl/saturated Cl) is due to the reduction of dissolved oxygen to hydrogen peroxide. Alternatively, the concentration of dissolved oxygen can also be determined using a Clark electrode. The concentration of hydrogen peroxide and dissolved oxygen during enzymatic conversion of glucose can be followed on line and be used to control the process.  相似文献   

18.
《Analytical letters》2012,45(11-12):2403-2411
Abstract

The modification of the surface of a platinum electrode by coating with a layer of a lipid mixture (asolectin), allows the relative measurement of hydrogen peroxide in the presence of interfering analytes. The lipid-enzyme complex and the platinum amperometric sensor offer greater selectivity and extended stability of the resulting probe. Measurements of glucose with the glucose oxidase enzyme and detection of the liberated hydrogen peroxide have been performed as a model system. Linear response of the signal versus glucose concentration was observed in the range of glucose concentration 1.10?3 ? 1.10?5 M with a response time of 20 s. The interferences of ascorbic acid, uric acid, iron (II), paracetamol, tyrosine and glutathion can be drastically minimized by appropriate adjustment of the amount of lipid contained in the biocatalyst layer.  相似文献   

19.
A sensitive and selective, reasonably fast method for the determination of glucose content has been developed. A glucose oxidase immobilized column was coupled to a small-size anion exchange column/borate buffer chromatograph. The hydrogen peroxide produced in the enzyme reaction was detected directly by an amperometric detector using a platinum working electrode. The detection limit was 0.03 ppm (1.5 x 10(-7) M, 3 pmol/injection). The linear dynamic range was three orders of magnitude at least. The system was stable and reproducible both in short- and long-term operation. The proposed method is suitable for analysis of complicated matrices of biological samples because of its good selectivity and sensitivity.  相似文献   

20.
Zhihuang Chen 《Talanta》2007,72(4):1410-1415
In this paper, the electrochemiluminescence (ECL) behavior of bis-[3,4,6-trichloro-2-(pentyloxycarbonyl)-phenyl] oxalate (BTPPO) at glassy carbon electrode (GCE) in phosphate buffer solution in the presence of hydrogen peroxide has been investigated when linear sweep voltammetry was applied. The optimum chemical conditions and electrochemical parameters for this ECL system have been investigated in detail. Under the optimum conditions, it was found that the concentration of BTPPO was linear with the ECL intensity in the range of 3.0 × l0−6 to 3.0 × 10−4 mol/L, and the detection limit (S/N = 3) for BTPPO was 1.0 × 10−7 mol/L. The possible mechanism for ECL of BTPPO at the GCE in the presence of hydrogen peroxide was also discussed. Furthermore, based on the fact that glucose oxidase can react with glucose to produce hydrogen peroxide, a new ECL sensing system of BTPPO has been developed for detection of glucose. The enhanced ECL intensity has a linear relationship with the concentration of glucose in the range of 1.0 × l0−4 to 1.0 × 10−3 mol/L, and the detection limit for glucose is found to be 5.0 × 10−5 mol/L (S/N = 3).  相似文献   