首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A nanocomposite was prepared by physical adsorption of?(cationic) methylene blue (MB) on (anionic) sodium dodecylsulfate (SDS) that was wrapped on multiwalled carbon nanotubes (MWCNTs) on the surface of a glassy carbon electrode. This electrostatic interaction enables electrical communication between the electrode and analyte. Horseradish peroxidase was then immobilized in a film of gelatin on the nanocomposite to form a biosensor for hydrogen peroxide. Scanning electron microscopy, transmission electron microscopy, Fourier transform infrared and UV?Cvis spectrometry, and cyclic voltammetry were applied to characterize the electrode. The addition of both MWCNTs and MB causes a synergistic effect and leads to a large signal enhancement. The prepared nanocomposite material modified sensor shows better response in presence of several interferences. The biosensor has detection limit of 5 nM of hydrogen peroxide (at S/N?=?3) with a linear response between 0.2???M and 1.4?mM. Its lifetime is >4?months under dry conditions at 4?°C.
Figure
A nanocomposite was prepared by physical adsorption of methylene blue on sodium dodecylsulfate that was wrapped on multiwalled carbon nanotubes on the surface of a glassy carbon electrode. This electrostatic interaction enables electrical communication between the electrode and analyte. The composite has been successfully applied for Hydrogen peroxide detection.  相似文献   

2.
A novel glucose biosensor was fabricated by immobilizing glucose oxidase (GOx) on Ag nanoparticles-decorated multiwalled carbon nanotube (AgNP-MWNT) modified glass carbon electrode (GCE). The AgNP-MWNT composite membrane showed an improving biocompatibility for GOx immobilization and an enhancing electrocatalytic activity toward reduction of oxygen due to decoration of AgNPs on MWNT surfaces. The AgNPs also accelerated the direct electron transfer between redox-active site of GOx and GCE surface because of their excellent conductivity and large capacity for protein loading, leading to direct electrochemistry of GOx. The glucose biosensor of this work showed a lower limit of detection of 0.01 mM (S/N?=?3) and a wide linear range from 0.025 to 1.0 mM, indicating an excellent analytical performance of the obtained biosensor to glucose detection. The resulting biosensor exhibits good stability and excellent reproducibility. Such bionanocomposite provides us good candidate material for fabrication of biosensors based on direct electrochemistry of immobilized enzymes.  相似文献   

3.
Narang J  Chauhan N  Pundir CS 《The Analyst》2011,136(21):4460-4466
We describe the construction of a polyaniline (PANI), multiwalled carbon nanotubes (MWCNTs) and gold nanoparticles (AuNPs) modified Au electrode for determination of hydrogen peroxide without using peroxidase (HRP). The AuNPs/MWCNT/PANI composite film deposited on Au electrode was characterized by Scanning Electron Microscopy (SEM) and electrochemical methods. Cyclic voltammetric (CV) studies of the electrode at different stages of construction demonstrated that the modified electrode had enhanced electrochemical oxidation of H(2)O(2), which offers a number of attractive features to develop amperometric sensors based on split of H(2)O(2). The amperometric response to H(2)O(2) showed a linear relationship in the range from 3.0 μM to 600.0 μM with a detection limit of 0.3 μM (S/N = 3) and with high sensitivity of 3.3 mA μM(-1). The sensor gave accurate and satisfactory results, when employed for determination of H(2)O(2) in milk and urine.  相似文献   

4.
The well dispersed and size-controlled Ag nanoparticles decorated multi-walled carbon nanotubes (MWCNT) were synthesized by a simple chemical plating method. The oxidized MWCNT surfaces could get a more controlled and specific nucleation of Ag nanoparticles. The as-prepared nanocomposites were characterized by transmission electron microscopy, X-ray diffraction and cyclic voltammetry. Randles-Sevcik plot suggested that the reaction of the nanocomposites in alkaline solution was a diffusion-controlled process. The electrocatalytic reduction property toward H2O2 was also studied.  相似文献   

5.
We report on a carbon nanotube (CNT) fiber microelectrode coated with palladium nanoparticles (PdNPs) and enabling electrochemical sensing of hydrogen peroxide (H2O2). The synergistic effects of the CNT fibers (good mechanical strength and large surface area) and of the PdNPs (high electrocatalytic activity) result in a microelectrode for H2O2 that exhibits a 2-s response time, a detection limit as low as 2 μM, a sensitivity of 2.75 A cm?2 M?1, and a linear response range from 2 μM to 1.3 mM (R?=?0.9994). The sensor is also selective and not interfered by potentially competing species in biological fluids, thus representing an inexpensive but highly sensitive and selective microsensor for H2O2.
Figure
Images ofthe palladium nanoparticle-coated carbon nanotube (PdNP/CNT) fiber microelectrode (left) and its amperometric response to hydrogen peroxide (H2O2) with different concentrations (right)  相似文献   

6.
Gold nanoelectrode ensembles were produced by electrodeposition using multiwalled carbon nanotubes (MWNTs) as template. A new third generation amperometric biosensor for hydrogen peroxide was developed based on adsorption of horseradish peroxidase (HRP) at the glassy carbon (GC) electrode modified with Au nanoelectrode ensembles/multiwalled carbon nanotubes/chitosan film. The resulting HRP biosensor offered an excellent detection for hydrogen peroxide at −0.11 V with a linear response range of 2.08 × 10−7 to 7.6 × 10−3 M with a correlation coefficient of 0.998, and response time <5 s. The detection limit was 1.02 × 10−7 M at 3σ. The biosensor displays rapid response, expanded linear response range, and excellent repeatability. The simple and fast fabrication of the sensor makes it superior to other techniques.  相似文献   

7.
Gold nanoparticles were deposited on the surface of multiwalled carbon nanotubes (MWNTs) functionalized with aliphatic bifunctional thiols (1,4-butanedithiol, 1,6-hexanedithiol, 1,8-octanedithiol, and 2-aminoethanethiol) through a direct solvent-free procedure. Small gold particles, with a narrow particle size distribution around 1.7 nm, were obtained on 1,6-hexanedithiol-functionalized MWNTs. For MWNTs functionalized with the aminothiol, the average Au particle size was larger, 5.5 nm, apparently due to a coalescence phenomenon. Gatan image filter (GIF) observations show that sulfur is at the nanotube surface with a non-homogeneous distribution. A higher sulfur concentration was observed around the gold nanoparticles' location.  相似文献   

8.
Nickel oxide/carbon nanotubes (NiO/CNTs) composite materials for supercapacitor are prepared by chemically depositing nickel hydroxide onto carbon nanotubes pretreated by ultrasonication and followed by thermal annealing at 300 °C. A series of NiO/CNTs composites with different weight ratios of nickel oxide versus carbon nanotubes are synthesized via the same route. The high-resolution TEM and SEM results show that a lot of nicks, which favored the nucleation of the nickel hydroxide formed on the outer walls of carbon nanotubes due to ultrasonic cavitations, and then nickel oxide coated uniformly on the outer surface of the individual carbon nanotubes. The NiO/CNTs electrode presents a maximum specific capacitance of 523 F/g as well as a good cycle life during 1,000 cycles in 6 M KOH electrolyte. The good electrochemical characteristics of NiO/CNTs composite can be attributed to the three-dimensionally interconnected nanotubular structure with a thin film of electroactive materials.  相似文献   

9.
Xiangjie Bo  Jing Bai 《Talanta》2010,82(1):85-214
A simple and facile synthetic method to incorporate Pt nanoparticles inside the mesopores of ordered mesoporous carbons (OMCs) is reported. The Pt/OMCs nanocomposite was characterized by transmission electron microscopy (TEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), Raman spectroscopy, and nitrogen adsorption-desorption. The results show that the incorporation of Pt nanoparticles inside the pores of OMCs does not change the highly ordered two-dimensional hexagonal mesostructure of OMCs matrix. Nonenzymatic amperometric sensor of hydrogen peroxide and glucose based on the Pt/OMCs nanocomposite-modified glassy carbon (GC) electrode is developed. Compared with the original OMCs-modified electrode, the Pt/OMCs-modified electrode displays improved current response towards hydrogen peroxide and gives linear range from 2 to 4212 μM. At an applied potential of −0.08 V, the Pt/OMCs nanocomposite gives linearity in the range of 0.5-4.5 mM glucose in neutral buffered saline solution. This glucose sensor also exhibits good ability of anti-interference to electroactive molecules. The combination the unique properties of Pt nanoparticles and the ordered mesostructure of OMCs matrix guarantees the enhanced response for hydrogen peroxide and glucose.  相似文献   

10.
In this report, a highly sensitive amperometric sensor based on MnO2-modified vertically aligned multiwalled carbon nanotubes (MnO2/VACNTs) for determination of hydrogen peroxide (H2O2) was fabricated by electrodeposition. The morphology of the nanocomposite was characterized by scanning electron microscopy, energy-dispersive X-ray spectrometer and X-ray diffraction. Cyclic voltammetry, chronoamperometry and electrochemical impedance spectroscopy were applied to investigate the electrochemical properties of the MnO2/VACNTs nanocomposite electrode. The mechanism for the electrochemical reaction of H2O2 at the MnO2/VACNTs nanocomposite electrode was also discussed. In borate buffer (pH 7.8, 0.20 M), the MnO2/VACNTs nanocomposite electrode exhibits a linear dependence (R = 0.998) on the concentration of H2O2 from 1.2 × 10−6 M to 1.8 × 10−3 M, a high sensitivity of 1.08 × 106 μA M−1 cm−2 and a detection limit of 8.0 × 10−7 M (signal/noise = 3). Meanwhile, the MnO2/VACNTs nanocomposite electrode is also highly resistant towards typical inorganic salts and some biomolecules such as acetic acid, citric acid, uric acid and d-(+)-glucose, etc. In addition, the sensor based on the MnO2/VACNTs nanocomposite electrode was applied for the determination of trace of H2O2 in milk with high accuracy, demonstrating its potential for practical application.  相似文献   

11.
采用一种温和且有效的方法,将聚丙烯酸非共价修饰到碳纳米管上,并以其为模板,在碳纳米管上原位均匀的生长铜纳米粒子,制备了铜/聚丙烯酸/碳纳米管(Cu/PAA/CNT)纳米复合材料,并以此材料构建了一种新型的非酶H2O2传感器,研究了其对H2O2的电催化行为。结果表明:铜纳米粒子较均匀的生长在碳纳米管上,制备的纳米复合材料修饰到电极表面对H2O2表现出良好的电流响应,可实现对H2O2的灵敏测定,其响应电流与H2O2的浓度在1.9×10-6~8.0×10-4mol/L范围内呈良好的线性关系,检测限达6.3×10-7mol/L。  相似文献   

12.
The growth of uncoated gold nanoparticles on the surface of multiwalled carbon nanotubes (MWCNTs) through the UV irradiation method was investigated. TEM observations showed that the size and the growth behavior of nanoparticles were primarily affected by the diameter of MWCNTs and solution pH values. The possible mechanisms were also discussed.  相似文献   

13.
A nonenzymatic method was developed for the detection and quantification of hydrogen peroxide using metallic sols obtained by the reduction of silver compounds with sodium borohydride in the presence of a surface stabilizer. These sols changed color on exposure to aqueous solutions of hydrogen peroxide. The nature of the stabilizer used in sol preparation affects spectral characteristics of the final product formed in the reaction with hydrogen peroxide. In the case of polyvinyl pyrrolidone, the intensity of the surface plasmon resosnance absorption band at 405 nm decreased. In using cetyltrimethylammonium bromide, a signal at 519 nm appeared along with the similar decrease in the absorption band at 408 nm. The band intensity depends on the concentration of hydrogen peroxide. The described phenomena can form a basis for the development of procedures for the qualitative and quantitative determination of hydrogen peroxide in water bodies.  相似文献   

14.
We report on an electrode for the amperometric determination of lorazepam. A glassy carbon electrode was coated with a molecular imprint made by electropolymerization of ortho-phenylenediamine and filled with multiwalled carbon nanotubes and gold nanoparticles, which enhances the transmission of electrons. The sensor was studied with respect to its response to hexacyanoferrate (III) as a probe and by electrochemical impedance spectroscopy, cyclic voltammetry and square wave voltammetry. The linear response range to Lorazepam is from 0.5 nM to 1.0 nM and from 1.0 nM to 10.0 nM, with a detection limit of 0.2 nM (at an S/N of 3). The electrode was successfully applied to determine Lorazepam in spiked human serum.
Figure 1
The preparation of schematic of the AuNP/MIP/f?MWCNT/GCE electrode  相似文献   

15.
16.
Yang C  Chai Y  Yuan R  Guo J  Jia F 《Analytical sciences》2012,28(3):275-282
Three novel hybrid materials have been synthesized by ligands: N-(2-vinylsulfanyl-ethylidene)-benzene-1,2-dimine (SBD), N-pyridin-2-ylmethylene-benzene-1,2-dimine (NBD) and N-furan-2-ylmethylene-benzene-1,2-dimine (OBD), covalently linking to multi-walled carbon nanotubes (MWCNTs). These MWCNT hybrid materials were used both as ionophores and as ion-to-electron transducers to construct Ag(+) carbon paste electrodes. The resulting electrodes show higher selectivity to Ag(+) than other cations tested. Among the three electrodes, the electrode based on SBD-g-MWCNTs with optimum composition shows the best performance to Ag(+). It exhibits an excellent Nernstian response to Ag(+) in the concentration range from 8.8 × 10(-8) to 1.0 × 10(-1) M with a detection limit of 6.3 × 10(-8) M, and it can also be used over a wide pH range of 3.0-8.0 with a quick response time of 5 s. The response mechanism of the proposed electrode was also investigated by using AC impedance and UV-vis spectroscopy techniques.  相似文献   

17.
Dai X  Wildgoose GG  Compton RG 《The Analyst》2006,131(8):901-906
The electrocatalytic detection of the anaesthetic halothane on a multiwalled carbon nanotube modified glassy carbon electrode is reported with a low limit of detection of 4.6 microM. A thorough investigation of the underlying cause of this apparent catalytic effect is undertaken by comparing the response of various carbon electrodes including glassy carbon, basal- and edge-plane pyrolytic graphite electrodes (bppg and eppg respectively) to increasing additions of halothane. The reduction of halothane is shifted by 250-300 mV to more negative potentials at an eppg electrode than that observed at the GC-CNT electrode. Therefore the results of this investigation show that, surprisingly, the electrocatalysis is not solely due to the introduction of edge-plane-like defect sites on the carbon nanotubes as is commonly found for many other substrates showing favourable voltammetry at nanotube modified electrodes. Instead, we reveal that in this unusual case the electroactive sites for the reduction of halothane are due to the presence of copper nanoparticles occluded within the carbon nanotubes during their production, which are never completely removed by standard purification techniques such as acid washing. This is only the third known case where apparent electrocatalysis by carbon nanotube modified electrodes is due to occluded metal-related nanoparticles within the nanotube structure, rather than the active sites being the edge-plane-like defect sites on the nanotubes. Furthermore this is the first case where the active sites are nanoparticles of copper metal, rather than metal oxide nanoparticles (namely oxides of iron(II)/(III)) as was found to be the case in the previous examples.  相似文献   

18.
19.
A.K. Upadhyay 《Talanta》2009,79(1):38-9495
A novel amperometric biosensor for the analytical determination of hydrogen peroxide was developed. The fabrication of the biosensor was based on the coimmobilization of horseradish peroxidase (HRP), methylene green (MG) and multiwalled carbon nanotubes within ormosils; 3-aminopropyltrimethoxysilane (APTMOS), 2-(3,4-epoxycyclohexyl)ethyltrimethoxysilane (ETMOS) and phenyltrimethoxysilane (PHTMOS). APTMOS determined the hydrophilicity/hydrophobicity of the ormosils and PHTMOS and ETMOS increased the physical and mechanical strength of the ormosil matrix. The ormosil modified electrodes were characterized with SEM, UV-vis spectroscopy and electrochemical methods. Cyclic voltammetry and amperometric measurements demonstrated the MG coimmobilized with HRP in this way, displayed good stability and could efficiently shuttle electrons between immobilized enzyme and electrode, and MWCNTs facilitated the electrocatalytic reduction of H2O2 at reduced over potential. The Micheaelis constant of the immobilized HRP was 1.8 mM, indicating a high affinity of the HRP to H2O2 without loss of enzymatic activity in ormosil matrix. The prepared biosensor had a fast response of H2O2, less than 10 s, and excellent linear range of concentration from 5 × 10−7 to 2 × 10−5 M with the detection limit of 0.5 μM (S/N = 3) under the optimum conditions. At the same time, the influence of solution pH, effect of enzyme amount, steady-state applied potential and temperature on the biosensor were investigated. The enzyme electrode retained about 90% of its initial activity after 30 days of storage in a dry state at 4 °C. The preparation of the developed biosensor was convenient and showed high sensitivity with good stability.  相似文献   

20.
Liu Y  Lei J  Ju H 《Talanta》2008,74(4):965-970
A kind of nanocomposites with good dispersion in water was prepared through noncovalent adsorption of toluidine blue (Tb) on multiwalled carbon nanotubes (MWCNT) for electric communication between horseradish peroxidase (HRP) and electrode. The nanocomposites could be conveniently cast on electrode surface. With the aid of chitosan, HRP was then immobilized on the nanostructure to form a reagentless amperometric sensor for hydrogen peroxide. UV-vis spectroscopy and electrochemical impedance spectroscopy were used to characterize the adsorption of Tb on MWCNT. The presence of both Tb as mediator of electron transfer and MWCNT as conductor enhanced greatly the enzymatic response to the reduction of hydrogen peroxide. The novel biosensor exhibited fast response towards hydrogen peroxide with a detection limit of 1.7x10(-6)M and the linear range extended up to 4x10(-4)M without the interference of ascorbic acid and uric acid. The Michaelis-Menten constant (K'(m)) of the immobilized HRP was evaluated to be 0.16mM.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号