首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
High-voltage hollow-cathode glow discharges are used more and more to generate intense, pulsed electron beams. Such intense electron beams can be produced with high efficiency in preionization-controlled open-ended hollow-cathode transient discharges (PCOHC). This novel discharge is initiated by a low-current dc preionization discharge. The beam parameters are similar to those of the electron beam generated in pseudospark discharges. In this work, we present some measurements of the parameters for the electron beam generated by using a multielectrode (multigap) system instead of the single-gap device in this PCOHC configuration. This kind of multielectrode device was already used in pseudosparks to improve the intensity and collimation of the extracted beam. By using the multigap instead of the single gap, the total beam current (100-120 A) and the energetic part of the beam current (peak current 60-90 A and electron energies higher than approximately 3 keV) were substantially increased. However, the energy spectrum of the fast component has a large fraction of electrons at lower energies (4-10 keV for 26 kV breakdown voltage) when a multigap device is used instead of the single-gap configuration. A comparison between the single-gap and multigap PCOHC-produced pulsed intense electron beam is made too. The differences between the high-power pulsed electron beams produced in single-gap and multigap PCOHC configurations seem to be due to different developments of beam generation phases  相似文献   

2.
介绍了450 kV数字化X光照相诊断系统的研制,该系统由450 kV脉冲X光机和抗辐照X光CCD相机组成。450 kV脉冲X光机输出的X射线脉冲半高宽为40 ns,1 m处剂量为5.210-6 C/kg,焦斑2~5 mm,2.5 m处可穿透20 mm的Fe。抗辐照X光CCD相机接收X光能谱范围为10~450 keV,有效成像面积最高可达100 mm100 mm,空间分辨率最高可达3 lp/mm,具有很强的抗电磁干扰能力。进行爆轰实验时在总防护为40 mm铝板的情况下,450 kV数字化X光照相诊断系统的照相视场可视范围超过70 mm,空间分辨率优于1.2 lp/mm。  相似文献   

3.
The results of experiments with a three-ring large-area diode that were conducted on an MIG pulse generator are reported. The MIG generator makes it possible to produce in a matched load electrical pulses up to 2 TW in power with an FWHM of 50–60 ns (1.2–1.4 TW and 80–90 ns in our experiments). In the operating mode of the generator, the current amplitude through the load is 2 MA (the current of a relativistic electron beam) at a diode voltage of ≈ 500 kV. As a load, a large-area vacuum diode with three ring-shaped cathodes is used. It is shown that about 20% of the energy stored in the capacitor bank can be converted to the energy of a relativistic electron beam by matching the output resistance of the MIG generator to the load resistance. When the beam slows down on a condensed foil target, the parameters of the resulting source are the following: the mean energy of X-ray quanta is ≈ 70 keV; irradiated area, 500 cm2; pulse FWHM, 65 ns; energy flux in the spectrum, 2 J/cm2; and percentage of X-ray radiation (10–100 keV) in the flux, ≈ 50%.  相似文献   

4.
基于Marx发生器原理设计了150kV脉冲X射线测试系统,该系统采用正负极充电的双边Marx发生器线路,Marx发生器设计为15级同轴结构,采用紧凑低电感设计来获得窄脉冲的输出。实验结果表明,X光机设计合理,获得了窄脉宽、高幅度的高压脉冲输出:在充电电压为20kV的情况下,X射线管电压150kV;X射线脉宽约60ns;25cm处剂量约7.8×10-6 C/kg;焦斑直径2.5mm。搭配计算机X射线摄影系统,成像面积可达30cm×40cm,分辨力大于1lp/mm,可以满足一般低能闪光照相的需要。  相似文献   

5.
According to the small size requirement for wide-band high-power microwave radiation, a superradiance backward wave oscillator (BWO) is proposed to generate such high-power microwave radiation with a low voltage (~20 kV) pulse power supply and low guiding magnet field (~0.1 T). In order to get a high-efficiency C-band superradiance BWO with a low beam voltage and a low guiding magnet field, the mechanism of superradiance in a BWO is explored in particle-in-cell simulation. With the oversized structure, the simulation shows that a microwave power of 405 kW with a frequency of 5.6 GHz and a spectrum width of 500 MHz can be obtained with a voltage of 23 kV and magnetic field of 0.1 T.  相似文献   

6.
A large orbit gyrotron with a 300 keV, 30 A, 20 ns electron beam has provided selective generation with radiation power from 1.5 MW at fundamental (wavelength of 14 mm) to 100 kW at the fifth cyclotron harmonic (wavelength of 4 mm). The next experiment with a unique electron beam (250 keV, 18 A, 10 μs, 0.6 mm in diameter) is in progress  相似文献   

7.
PETRA III is a new hard X-ray synchrotron radiation source, operating at 6 GeV with a beam current of up to 100 mA and extremely low horizontal emittance of 1 nm rad. Such low emittance is achieved by using two 100 m long damping wiggler sections which reduce the emittance by a factor of 4. Altogether the damping sections contain 20 wigglers of 4m length each. The emitted synchrotron radiation power produced by wigglers amounts to 420 kW at 100 mA beam current in total. In the new octant of PETRA III, there are 14 undulator beamlines, with a brilliance up to 1021 (s mrad2 mm2 0.1% BW)−1 which cover an energy range from 0.3 keV to more than 100 keV. The low emittance raises very high requirements to the field quality of the insertion devices. At first, it should not affect the positron beam trajectory. Secondly, the spectral properties of the radiation created, like the intensity of higher harmonics, should not be limited by the undulator field quality, but by the beam emittance effects in order to have some reserve for future machine upgrades or possible radiation demagnetization. This paper presents the current status of PETRA III insertion devices and describes intermediate commissioning results like impact of IDs on the positron beam orbit or photon beam and radiation problems.  相似文献   

8.
首次实现直流磁体W波段二次谐波回旋管连续波稳定运行。回旋管工作时所需1.8 T磁场由一个水冷直流线圈产生。直流线圈励磁电流为500 A,功耗28 kW,内孔直径66 mm,可直接将回旋管插入内孔中。回旋管内电子束由双阳极磁控注入电子枪产生。采用高效率内置准光模式变换器实现束波分离并输出准高斯波束。研制的回旋管工作频率为94.08 GHz,腔内工作模式为TE02。实验中成功实现5 min连续稳定运行,输出功率达到12 kW。电子束电压为45 kV,电流1.7 A,对应的输出效率15.7 %。  相似文献   

9.
A systematic theoretical and experimental study on a 35-GHz 45-kV third-harmonic gyrotron with a permanent magnet system is presented in this paper. A complex cavity with gradual transition and a diode magnetron injection gun (MIG) are employed in the gyrotron. A self-consistent field nonlinear theoretical investigation and numerical simulation for electron beam interaction with RF fields are given. The diode MIG is simulated numerically utilizing our code in detail. The permanent magnet system provided the maximum axial magnetic field of about 4.5 kG in the cavity region of the gyrotron. The Ka band third-harmonic complex cavity gyrotron with a permanent magnet system has been designed, constructed, and tested. A pulse output power of 147.3 kW was obtained at a beam voltage of 45 kV with beam current of 32.2 A, corresponding to an efficiency of 10.2%.  相似文献   

10.
The generation and control of microwave electron cyclotron resonance (ECR) plasma cathode electron beam is studied experimentally. A complete set of discharge, electron beam extraction, focusing and measuring system was set up. The characteristics and performance of microwave ECR plasmas as electron beam extraction source were studied by measuring the current of water cooling target and the beam spot size on the target. Experimental results indicated that both microwave input power and accelerating voltage are conducive to improving electron beam current. The influence of gas pressure on the electron beam current was complex. With the increase of gas pressure, the electron beam current is characterized by decreasing first and then increasing. The extracted electron current of microwave ECR plasma cathode can reach 75mA at gas pressure of 7×10−4Pa, and the energy of the electron beam can reach 9keV. The energy utilization can reach 0.6. By adjusting the current of the focusing coil, the diameter of electron beam spot is reduced from 20mm to 13mm and the electron beam current keeps the value unchanged.  相似文献   

11.
介绍了实验室研制的微波电子回旋共振(ECR)等离子体阴极电子束系统及初步研究结果,该系统包括微波ECR 等离子体源、电子束引出极、聚焦线圈等。通过测量水冷靶电流和靶上的束斑尺寸,实验研究了微波ECR 等离子体阴极电子束的流强、聚束性能等随电子束系统工作条件的变化。结果表明:微波输入功率越高、引出电压越高,引出电子束流强越大;工作气压对电子束流强的影响较复杂,随气压增加呈现出先降低后升高的特点;在7×10−4Pa 的极低气压下电子束流强可达75mA,引出电压9kV;能量利用率可达0.6;调整聚焦线圈的驱动电流,电子束的束斑直径从20mm 减小到13mm,电子束流强未有明显变化。  相似文献   

12.
基于快前沿Mini-Marx发生器拓扑结构和冷阴极反射靶真空X射线二极管一体化设计研发出了紧凑型便携式150kV闪光X光源系统。介绍了设计的Mini-Marx发生器和闪光X光二极管,给出了相应的实验结果。该闪光X光源系统获得了距光源25cm处剂量大于7.7×10-6 C/kg、1m处穿透铝大于60mm、焦斑1~3mm可调的闪光X射线。该闪光X光源和成像单元组成的闪光照相具有系统体积小、运行可靠的特点。  相似文献   

13.
Nike is a recently completed multikilojoule krypton-fluoride (KrF) laser that has been built to study the physics of direct-drive inertial confinement fusion. The two final amplifiers of the Nike laser are both electron-beam-pumped systems. This paper describes these two amplifiers, with an emphasis on the pulsed power. The smaller of the two has a 20×20 cm aperture, and produces an output laser beam energy in excess of 100 J. This 20 cm Amplifier uses a single 12 kJ Marx generator to inject two 300 kV, 75 kA, 140 ns flat-top electron beams into opposite sides of the laser cell. The larger amplifier in Nike has a 60×60 cm aperture, and amplifies the laser beam up to 5 W. This 60 cm amplifier has two independent electron beam systems. Each system has a 170 kT Marx generator that produces a 670 kV, 540 kA, 240 ns Bat-top electron beam. Both amplifiers are complete, fully integrated into the laser, meet the Nike system requirements, and are used routinely for laser-target experiments  相似文献   

14.
中国工程物理研究院计划开展XFEL光源的研制,主要通过电子束在波荡器中的辐射特性产生硬X射线。根据理论分析和数值模拟,在电子束最高能量可达12GeV的实际条件下,初步设计了一条间隙可调的真空外波荡器束线,波荡器分为25段,每段长3.86m,间隙7~10mm,周期长度25.4mm,磁场0.636~1.03T,束线总长120m左右,辐射光子能量为3~25keV。  相似文献   

15.
Synchrotron radiation (SR) generated by homogeneous magnetic fields of bending magnets is now employed at the Siberia-2 electron storage ring. It is planned that, in the near future, most of the storage ring’s free straight sections will be equipped with insertion devices (undulators and wigglers). Two projects of specialized radiation sources based on the Siberia-2 stor age ring are discussed. The first source is a vacuum milliundulator intended for generation of extremely bright X-ray beams. An X-ray source with vertically limited diffraction is shown to be feasible when the vertical emittance of an electron beam is equal to the diffraction emittance of photons with an energy of 2 keV. The second source uses edge radiation (ER) generated at the ends of bending magnets of the storage ring. Calculations show that, in the infrared and ultraviolet spectral regions, the ER intensity must exceed the intensity of standard SR formed by the homogeneous field of a bending magnet.  相似文献   

16.
曾造金  胡芯瑞  蒋艺  胡鹏  马国武  马乔生 《强激光与粒子束》2020,32(8):083002-1-083002-5
电子光学系统是行波管的核心部件之一,在太赫兹频段,电子束通道很小,导致高电流密度电子束的传输非常困难。基于220 GHz折叠波导行波管慢波结构设计所需束流参数,根据理论分析和电磁仿真软件,设计了一款采用均匀永磁聚焦对电子束进行约束的电子光学系统。仿真结果显示,当电子束通道直径0.3 mm、长度31 mm时,在阴阳极压差20 kV的条件下阴极发射电流141 mA,电子流通率100%。根据设计结果封接了流通管,实验结果显示,当阴阳极压差20 kV时,阴极发射电流138.5 mA,收集极电流125.5 mA,电子流通率91%。  相似文献   

17.
A system for the electron and photon therapy has been designed and developed at SAMEER, IITB, Mumbai. All the components of the system such as the 270° beam bending electromagnet, trim coils, magnet chamber, electron scattering foil, slits, applicators, etc., were designed and fabricated indigenously. The electrons of 6, 8, 9, 12, 15 and 18?MeV energies were provided by a linear accelerator, indigenously designed and made at SAMEER, IITB campus, Mumbai. The electron beam from the LINAC enters the magnet chamber horizontally, and after deflection and focusing in the 270° bending magnet, comes out of the exit port, and travels a straight path vertically down. After passing through the beryllium and tantalum scattering foils, the electron beam gets scattered and turns into a solid cone shape such that the diameter increases with the travel distance. The simulation results indicate that at the exit port of the 270° beam bending magnet, the electron beam has a divergence angle of ≤ 3?mrad and diameter ~2–3?mm, and remains constant over 6–18?MeV. Normally, 6–18?MeV electrons are used for the electron therapy of skin and malignant cancer near the skin surface. On a plane at a distance of 100?cm from the scattering foils, the size of the electron beam could be varied from 10?cm?×?10?cm to 25?cm?×?25?cm using suitable applicators and slits. Different types of applicators were therefore designed and fabricated to provide required beam profile and dose of electrons to a patient. The 6?MeV cyclic electron accelerator called Race-Track Microtron of S. P. Pune University, Pune, was extensively used for studying the performances of the scattering foils, electron beam uniformity and radiation dose measurement. Different types of thermoluminescent dosimetry dosimeters were developed to measure dose in the range of 1–10kGy.  相似文献   

18.
In the beginning of the 90s,T.Taylor and his collaborators demonstrated ECR sources operating at low frequency(i.e.2.45GHz)are able to produce very intense single charge light ion beams. At CEA/Saclay,the SILHI source developments started in 1995.Since 1997 more than 100mA proton or deuteron beams are routinely produced in pulsed or continuous mode.To comply with ADS reliability constraint,important improvements have been performed to increase the installation reliability.Moreover,to optimize the beam transport in the low energy beam line,the extraction system was carefully designed and space charge compensation studies were undertaken.An important step has been reached in 2005 with the development of a permanent magnet source able to produce a total beam of 109mA at 85kV. A new test bench named BETSI,especially dedicated to permanent magnet source developments,is presently under construction.It will allow analysing positive or negative extracted beams up to 50keV and 100mA. In addition,for several years work has been done to optimize the production of negative hydrogen ion beam with such an ECR source.Recent analysis pushed towards the construction of a new set up based on a multicusp magnetic configuration. After a brief overview of the CEA/Saclay source developments,this article will point out on the recent results and present status.  相似文献   

19.
设计了一套0.22THz折叠波导行波管电子光学系统,详细介绍了电子枪和周期永磁聚焦系统的设计过程,在电子枪电子束束腰与磁系统不匹配情况下,对磁场过渡区进行了优化设计,以此为基础利用磁场仿真软件对磁场进行模拟和优化,并把磁场位形代入电磁仿真软件进行电子束传输仿真,优化后的电子光学系统发射束流10mA,阴极电压15kV,束流通过率96%。通过实验验证,流通管束流通过率93%,高频样管束流通过率94%,与设计相符。高频样管实现连续波运行,功率大于0.4 W,3dB带宽大于12GHz。  相似文献   

20.
A crystal bender for sagittal focusing has been designed for standard monochromators at SPring-8. The bender does not move the position of the crystal center when the bending radius is changed. Sagittal focusing from 40 keV to 60 keV was achieved by using Si(311) double crystals. The flux density of the focused beam measured at 40 keV was 15 times higher than that of the unfocused beam. The height deviation of the focused beam throughout the measured energy range was within +/- 0.15 mm.  相似文献   