1.
高强聚焦超声(HIFU)加热活体组织中的温度分布   总被引:2,自引:1,他引:1       下载免费PDF全文
钱祖文 《应用声学》2010,29(4):269-272
在高强聚焦超声(HIFU)加热的情况下,利用多针射频(RF)测温装置测量活体组织内的温度分布,结果表明,温度梯度依赖于局部温度,温度越高,梯度越大。此外,本文还研究了血流对温度梯度的影响,结果似乎证实了理论预测,即血流(或血液灌注)减缓了温度(梯度)的变化。  相似文献   

2.
Shou W  Huang X  Duan S  Xia R  Shi Z  Geng X  Li F 《Ultrasonics》2006,44(Z1):e17-e20
How to measure the acoustic power of HIFU is one of the most important tasks in its medical application. In the paper a whole series of formula for calculating the radiation force related to the acoustic power radiated by a single element focusing transducer and by the focusing transducer array were given. Various system of radiation force balance (RFB) to measure the acoustic power of HIFU in medicine were designed and applied in China. In high power experiments, the dependence of radiation force acting the absorbing target on the target position at the beam axis of focusing transducer was fined. There is a peak value of "radiation force" acting the absorbing target in the focal region when the acoustic power through the focal plane exceeds some threshold. In order to avoid this big measurement error caused by the 'peak effect' in focal region, the distance between the absorbing target of RFB and the focusing transducer or transducer array was defined to be equal to or less than 0.7 times of the focal length in the National Standard of China for the measurements of acoustic power and field characteristics of HIFU. More than six different therapeutic equipments of HIFU have been examined by RFB for measuring the acoustic power since 1998. These results show that RFB with the absorbing target is valid in the acoustic power range up to 500W with good linearity for the drive voltage squared of focusing transducer or array. The uncertainty of measurement is within +/-15%.  相似文献   

3.
4.
HIFU can pass through tissues and accurately damage target tissues inside organisms. This article reports on the oriented damage effects of HIFU upon miniswine internal and external liver tissues, and suggests a new conception of the 'biological focal field'. The results revealed that: (1) HIFU can be used to damage accurately liver tissues under the guide of a B-modal ultrasound device; (2) the scope of the injury is connected with sound intensity and irradiation time; and (3) the different layers of tissue through which the ultrasound has passed remain undamaged.  相似文献   

5.
研制一种将机械天平、辐射压力法和智能控制结合在一起的大功率超声功率计,该功率计可以安装不同种类的反射靶面或吸收靶面对多种超声换能器进行功率测量;用砝码对该功率计进行校准和误差分析,结果显示该功率计具有稳定性好、精度高、测量范围大的特点。用锥面反射靶和吸收靶对高强度聚焦超声肿瘤治疗头的输出功率进行测量,实验结果表明:一方面该功率计可以满足大功率、高精度测量要求,另一方面被测量的临床治疗用高强度聚焦超声肿瘤治疗头的驱动电压在600-2200 V之间,其功率输出稳定、可靠,在此范围之外功率输出误差变大,超过5%。  相似文献   

6.
This study evaluates the feasibility of using high intensity focused ultrasound (HIFU) for the treatment of hydatid cysts of the liver. HIFU ablation was carried out in 62 patients with echinococcosis of the liver. The mean age of patients was 40.76 ± 14.84 (range: 17–72 years). The effectiveness of the treatment was monitored in real-time by changes in the gray-scale, and by morphological studies, computed tomography, magnetic resonance imaging, and ultrasound.Criteria for evaluating the effectiveness of treatment in real time were outlines. Cytomorphological picture of destructive changes of parasitic elements was presented as well. Loss of embryonic elements of the parasite was observed at the subcellular level after HIFU-ablation and underlines the effectiveness of HIFU.  相似文献   

7.
熊六林 《物理》2007,36(9):715-719
高强度聚焦超声是近几年发展起来的一种新的非介入性肿瘤治疗技术,临床应用越来越广,文章就其在不同肿瘤如前列腺癌、肝癌、胰腺癌、子宫肌瘤等治疗中的应用及进展进行评述。  相似文献   

8.
熊六林 《物理》2007,36(09):715-719
高强度聚焦超声是近几年发展起来的一种新的非介入性肿瘤治疗技术,临床应用越来越广,文章就其在不同肿瘤如前列腺癌、肝癌、胰腺癌、子宫肌瘤等治疗中的应用及进展进行评述。  相似文献   

9.
液体中高强度聚焦超声场及其测量   总被引:1,自引:0,他引:1  
寿文德  夏荣民  段世梅  卜书中 《物理》2007,36(10):764-770
基于已知文献,文章介绍了液体中高强度聚焦超声场的基本性质,包括传播、频谱、吸收、聚焦、辐射力等特性,描述了它的物理图景和测量方法。  相似文献   

10.
相控阵高强度聚焦超声的研究进展   总被引:2,自引:0,他引:2  
王晓东  王君琳  李平 《物理》2007,36(10):758-763
相控阵高强度聚焦超声(high Intensity focused ultrasound,HIFU)技术可以通过电子调相自由控制聚焦区域中焦点的形状、位置、个数等,实现高精度、高效率的治疗。文章主要介绍了相控聚焦超声的原理、阵型设计、声场优化、控制算法、电路设计以及换能器材料等几个方面。  相似文献   

11.
ObjectiveTo evaluate the long-term improvement of clinical symptoms of adenomyosis after treatment with ultrasound-guided high intensity focused ultrasound (USgHIFU).MethodsFrom January 2010 to December 2011, 350 patients with adenomyosis were treated with USgHIFU. Among the 350 patients, 224 of them completed the two years follow-up. The patients were followed up at 3 months, 1 year, and 2 years after HIFU treatment. Adverse effects and complications were recorded.ResultsAll patients completed HIFU ablation without severe postoperative complications. 203 of the 224 patients who showed varying degrees of dysmenorrhea before treatment had the symptom scores decreased significantly after treatment (P < 0.001). The relief rate was 84.7%, 84.7%, and 82.3%, respectively at 3 months, 1 year, and 2 years after treatment. The menstrual volume in 109 patients with menorrhagia was significantly improved after treatment (P < 0.001) with a relief rate of 79.8%, 80.7%, and 78.9%, respectively at 3 months, 1 year, and 2 years after HIFU treatment.ConclusionWith its ability to sustain long-term clinical improvements, HIFU is a safe and effective treatment for adenomyosis.  相似文献   

12.
高强度聚焦超声(HIFU)治疗中的驱动电功率对治疗效率起着非常关键的作用,驱动电功率控制的精准性势必会影响治疗的效率和安全性。前期研究表明:HIFU治疗过程中焦域瞬态物理特性的变化会导致换能器的负载阻抗发生变化,进而影响HIFU驱动电功率,但驱动电功率与焦域瞬态物理特性之间的影响关系及规律尚不明确。该文基于电压、电流传感器、空化检测探头和温度传感器等器件,构建了一种HIFU治疗中驱动电功率实时监测及焦域声空化、温度检测系统。基于该实验研究系统,以离体牛心组织作为HIFU辐照对象,分别研究了HIFU焦域温度变化、声空化及组织损伤与驱动电功率之间的变化关系及规律。研究结果表明:当焦域温度升高时,驱动电功率缓慢上升,驱动电功率与温度变化有良好的相关性;当空化产生时,驱动电功率出现明显的波动;当组织出现损伤时,驱动电功率呈陡然下降的变化。三种情景下,驱动电功率变化有明显区别,这有望为区分HIFU治疗过程中焦域处发生损伤和空化以及实时监测靶组织损伤程度提供一种新的解决方案。  相似文献   

13.
微泡对高强度聚焦超声(HIFU)治疗具有增效作用,而HIFU治疗中不同声学条件下微泡对HIFU治疗焦域的影响尚不清楚。本文基于声传播方程、Yang-Church气泡运动方程、生物热传导方程、时域有限差分法(FDTD)、龙格-库塔(RK)法数值仿真研究输入功率、激励频率和气泡初始半径对HIFU在含气泡体模中形成焦域的影响,并利用含Sono Vue造影剂的仿组织体模研究进行实验验证。结果表明,增大输入功率、气泡初始半径和升高激励频率均可增大焦域,随着输入功率的增大,焦域形状可能发生变化,而随着激励频率升高和气泡初始半径的增大,焦域会向远离换能器的方向移动。  相似文献   

14.
A new approach for characterizing high intensity focused ultrasound (HIFU) transducers is presented. The technique is based upon the acoustic streaming field generated by absorption of the HIFU beam in a liquid medium. The streaming field is quantified using digital particle image velocimetry, and a numerical algorithm is employed to compute the acoustic intensity field giving rise to the observed streaming field. The method as presented here is applicable to moderate intensity regimes, above the intensities which may be damaging to conventional hydrophones, but below the levels where nonlinear propagation effects are appreciable. Intensity fields and acoustic powers predicted using the streaming method were found to agree within 10% with measurements obtained using hydrophones and radiation force balances. Besides acoustic intensity fields, the streaming technique may be used to determine other important HIFU parameters, such as beam tilt angle or absorption of the propagation medium.  相似文献   

15.
相控阵高强度聚焦超声高阵元驱动效率相位独立控制方法   总被引:1,自引:0,他引:1  
徐丰  陆明珠  万明习 《声学学报》2010,35(5):488-494
针对如何简化上百阵元高强度聚焦超声相控阵控制模块的问题,本文提出高阵元驱动效率的相位独立控制方法。利用该方法计算了一种256阵元中心开孔球面相控阵的聚焦声场,并与传统的幅度相位综合控制方法进行了分析和比较。计算和实验结果表明该方法在简化相控阵驱动控制模块、提高阵元驱动效率的同时,可以有效实现相控阵的空间三维单焦点聚焦。由于阵元驱动控制的简化而引起的焦域能量偏差,可以通过适当调整相控阵输入总声功率进行有效的补偿。  相似文献   

16.
To address the challenges associated with measuring the ultrasonic power from high-intensity focused ultrasound transducers via radiation force, a technique based on pulsed measurements was developed and analyzed. Two focused ultrasound transducers were characterized in terms of an effective duty factor, which was then used to calculate the power during the pulse at high applied power levels. Two absorbing target designs were used, and both gave comparable results and displayed no damage and minimal temperature rise if placed near the transducer and away from the focus. The method yielded reproducible results up to the maximum pulse power generated of approximately 230 W, thus allowing the radiated power to be calibrated in terms of the peak-to-peak voltage applied to the transducer.  相似文献   

17.
多阵元相控阵换能器具有焦距可调和可实现经颅聚焦等优势,近来受到众多研究者的关注,其相位控制系统是决定多阵元相控换能器能否应用于临床的关键技术之一。在输出信号稳定的同时提高高强度聚焦超声相位控制系统精度是设计过程中的重点与难点。本文基于现场可编程门阵列设计了一种高强度聚焦超声相位控制系统。实测结果表明,多通道延时分辨率为1 ns,延时误差小于1 ns,可满足多阵元高强度聚焦超声治疗相控聚焦换能器延时精度的需要。  相似文献   

18.
范鹏飞  于洁  杨鑫  屠娟  郭霞生  黄品同  章东 《中国物理 B》2017,26(5):54301-054301
High intensity focused ultrasound(HIFU) has shown a great promise in noninvasive cancer therapy. The impact of acoustic cavitation on the lesion formation induced by HIFU is investigated both experimentally and theoretically in transparent protein-containing gel and ex vivo liver tissue samples. A numerical model that accounts for nonlinear acoustic propagation and heat transfer is used to simulate the lesion formation induced by the thermal effect. The results showed that lesions could be induced in the samples exposed to HIFU with various acoustic pressures and pulse lengths. The measured areas of lesions formed in the lateral direction were comparable to the simulated results, while much larger discrepancy was observed between the experimental and simulated data for the areas of longitudinal lesion cross-section. Meanwhile,a series of stripe-wiped-off B-mode pictures were obtained by using a special imaging processing method so that HIFUinduced cavitation bubble activities could be monitored in real-time and quantitatively analyzed as the functions of acoustic pressure and pulse length. The results indicated that, unlike the lateral area of HIFU-induced lesion that was less affected by the cavitation activity, the longitudinal cross-section of HIFU-induced lesion was significantly influenced by the generation of cavitation bubbles through the temperature elevation resulting from HIFU exposures. Therefore, considering the clinical safety in HIFU treatments, more attention should be paid on the lesion formation in the longitudinal direction to avoid uncontrollable variation resulting from HIFU-induced cavitation activity.  相似文献   

19.
A shaped-based ultrasound tomography method is proposed to reconstruct ellipsoidal objects using a linearized scattering model. The method is motivated by the desire to detect the presence of lesions created by high intensity focused ultrasound (HIFU) in applications of cancer therapy. The computational size and limited view nature of the relevant three-dimensional inverse problem renders impractical the use of traditional pixel-based reconstruction methods. However, by employing a shape-based parametrization it is only necessary to estimate a small number of unknowns describing the geometry of the lesion, in this paper assumed to be ellipsoidal. The details of the shape-based nonlinear inversion method are provided. Results obtained from a commercial ultrasound scanner and a tissue phantom containing a HIFU-like lesion demonstrate the feasibility of the approach where a 20 mm x 5 mm x 6 mm ellipsoidal inclusion was detected with an accuracy of around 5%.  相似文献   

20.
The principle of forming a special form of powerful acoustic signals is proposed, which makes it possible to ensure precise spatiotemporal beam focusing. The introduction of a transverse-coordinate-dependent local wave frequency is suggested, due to which the equality of the formation lengths of a discontinuity for all rays is achieved. This thereby ensures an increase in nonlinear absorption; as a result, the temperature and radiation action of focused ultrasound on the medium increase.  相似文献   