首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A sensitive and highly selective high-performance liquid chromatography (HPLC) method was developed for the determination of vitamin K homologues including phylloquinone (PK), menaquinone-4 (MK-4) and menaquinone-7 (MK-7) in human plasma using post-column peroxyoxalate chemiluminescence (PO-CL) detection following on-line ultraviolet (UV) irradiation. The method was based on ultraviolet irradiation (254 nm, 15 W) of vitamin K to produce hydrogen peroxide and a fluorescent product at the same time, which can be determined with PO-CL detection. The separation of vitamin K by HPLC was accomplished isocratically on an ODS column within 35 min. The method involves the use of 2-methyl-3-pentadecyl-1,4-naphthoquinone as an internal standard. The detection limits (signal-to-noise ratio = 3) were 32, 38 and 85 fmol for PK, MK-4 and MK-7, respectively. The recoveries of PK, MK-4 and MK-7 were greater than 82% and the inter- and intra-assay R.S.D. values were 1.9-5.4%. The sensitivity and selectivity of this method were sufficient for clinical and nutritional applications.  相似文献   

2.
3.
A novel continuous-flow system for the dynamic extraction of water soluble metal fractions in airborne particulate matter (APM) with subsequent inductively coupled plasma optical emission spectrometric (ICP-OES) analysis of derived extracts is presented. The fully automated extraction system with on-line multi-element detection offers enhanced sensitivity when compared to batch-wise counterparts; additionally it provides information about the extraction process. With the developed procedure detection limits in the order of 1.5 (Ba) to 8.0 (Ni) ng extractable mass per investigated sample could be achieved, which translates to method detection limits for soluble metal concentrations in APM ranging from 0.2 ng m−3 (Ba) to 0.9 ng m−3 (Fe). Reproducibility of analysis was determined by replicate measurement (n = 6) of an APM sample with an aerodynamic diameter ≤10 μm (PM10), derived results varied between 3.5% (Mn) and 12.1% (Ni) relative standard deviation. Method validation was accomplished by comparison of extracted soluble and remaining non-soluble fractions with the total metal contents of the investigated PM10 samples, showing an excellent mass balance for all elements. Application of the developed procedure for the analysis of water soluble metal fractions in PM10 samples (n = 16) from Linz (Austria) indicated a high variability of extractable fractions ranging from 11.7 ± 7.2% (Fe) to 48.8 ± 15.4% (Mn) of the total metal contents.  相似文献   

4.
A highly sensitive method for measuring endogenous vitamin K1, menaquinone-4 (which is one of the K2 vitamins) and vitamin K1 2,3-epoxide in human plasma was developed, based on high-performance liquid chromatography with coulometric reduction and fluorimetric detection, following extraction from plasma and purification on a Sep-Pak silica cartridge. The detection limits of vitamin K1, menaquinone-4 and vitamin K1 2,3-epoxide were 5, 5 and 8 pg per injection for the standard substances and 30, 30 and 50 pg/ml in human plasma, respectively.  相似文献   

5.
Owing to the pharmacological and clinical importance of the determination of plasma and urine levels of the hydroxy metabolites of clobazam and N-desmethylclobazam in healthy volunteers and in epileptic patients, a high-performance liquid chromatographic (HPLC) method was developed that permits the determination of all these compounds in the same plasma or urine sample. The method involved ether extraction at pH 13 with diazepam as internal standard for the measurement of clobazam and N-desmethylcobazam, followed by ether extraction at pH 9 with nitrazepam as internal standard for the measurement of the hydroxy derivatives. The limit of detection was about 10-20 ng/ml for each of these compounds. Applications to patients were limited by chromatographic interferences between the hydroxy metabolites and some medications currently associated with clobazam in the treatment of epilepsy. The only interference in clobazam and N-desmethylclobazam analysis was from N-desmethyldiazepam. Despite these inconveniences, this HPLC procedure appears to be the only available method for the simultaneous quantification of clobazam and its three main metabolites.  相似文献   

6.
7.
8.
9.
Zheng J  Shibata Y  Furuta N 《Talanta》2003,59(1):27-36
Analytical methods for the speciation of nine selenium species (selenite, selenate, selenourea, trimethylselenonium ion, selenocystamine, selenocystine, selenocysteine, selenomethionine and selenoethionine) that are commonly encountered in biological and environmental samples were developed. Good separation was achieved by either a mixed ion-pair reversed phase chromatography (LiChrosorb RP 18, 2.5 mM 1-butanesulfonate-8 mM tetramethylammonium hydroxide-4 mM malonic acid-0.05% methanol, pH 4.5) or a conventional ion-pair reversed phase chromatography (Inertsil ODS, 10 mM tetraethylammonium hydroxide-4.5 mM malonic acid, pH 6.8) with on-line ICP-MS detection. Using a 20-μl sample loop, low detection limits around 1 ng ml−1 expressed as Se were achieved for the examined selenium species. The methods were used for the determination of selenoamino acids in a selenium nutritional supplement. The developed methods were found to be rather robust. No alteration of the separation was observed when the protease enzymatic extracts were analyzed without dilution. Both water extracts and enzymatic extracts were chromatographed first with the mixed ion-pair reversed phase chromatographic system, then the major chromatographic peaks were collected and analyzed by the second ion-pair reversed phase chromatographic system for a further verification of their identity. Selenomethionine was found to be the major selenium species in the supplement. A major unknown species, probably Se-adenosylhomocysteine, could be determined in the extracts. A biological reference material, Dolt-2, was also examined for the selenoamino acids. Selenocystine and selenomethionine could be detected in its enzymatic extract, suggesting that Dolt-2 may be used as a reference material for the identification of selenoamino acids in biological and environmental samples. As selenoethionine does not occur naturally in the investigated samples, it is added as an internal standard in this study.  相似文献   

10.
建立了一种同时检测调制乳粉中维生素K1和维生素K2的柱后还原-高效液相色谱-荧光检测方法。样品用水溶解,经脂肪酶酶解,2.5 mol/L氢氧化钠溶液和乙醇溶液皂化,正己烷萃取,氮吹浓缩后,用甲醇复溶。通过Xbridge C18色谱柱分离,锌粉还原柱柱后还原,荧光检测器检测,激发波长为326 nm,发射波长为432 nm,外标法定量。结果表明,维生素K1在0.0025~2.0 μg/mL、维生素K2在0.01~2.0 μg/mL范围内线性关系良好,相关系数均大于0.999,维生素K1和维生素K2的检出限分别为0.07 μg/100 g和0.24 μg/100 g,定量限分别为0.2 μg/100 g和0.8 μg/100 g;方法的加标回收率为80.39%~94.39%,精密度为0.85%~3.98%。该方法灵敏度高,重复性好,结果准确,适用于调制乳粉中维生素K1和维生素K2的分析检测。  相似文献   

11.
The oxidation of selected clinically important neurotransmitter metabolites with acidic potassium permanganate in the presence of polyphosphates evokes chemiluminescence of sufficient intensity to enable the sensitive determination of these species. Limits of detection for 5-hydroxyindole-3-acetic acid (5-HIAA), vanilmandelic acid (VMA; α,4-dihydroxy-3-methoxybenzeneacetic acid), 4-hydroxy-3-methoxyphenylglycol (MHPG), homovanillic acid (HVA, 4-hydroxy-3-methoxyphenylacetic acid) and 3,4-dihydroxyphenylacetic acid (DOPAC) were between 5 × 10−9 and 4 × 10−8 M, using flow-injection analysis methodology. In addition, we demonstrate the rapid determination of homovanillic acid and 5-hydroxyindole-3-acetic acid in human urine - without the need for extraction procedures - using monolithic column chromatography with chemiluminescence detection.  相似文献   

12.
A new method for the determination of selenomethionine (SeMet) was developed using capillary electrophoresis on-line coupled with electrochemiluminescence detection. The effects of several factors such as detection potential, concentration and pH of phosphate buffer, separation voltage and injection voltage were investigated. Under optimal conditions, the linear concentration range for SeMet was 0.001 to 0.8 μg mL?1 with a correlation coefficient of 0.9996. The limit of detection (S/N?=?3) was 0.39 ng mL?1. The recovery of SeMet in selenium-enriched yeast (SEY) was 98.6% on an average. The method presented is simple, quick, sensitive and can be reliably applied to the determination of SeMet in SEY.  相似文献   

13.
Vitamins D2 and D3 and their corresponding previtamins and provitamins were resolved by reversed-phase high-performance liquid chromatography using a ternary solvent system (acetonitrile-methanol-water) pumped according to a gradient elution programme. The D vitamins were also resolved in the presence of other lipid-soluble vitamins (A, E and K1) and carotene. The peaks were monitored with a UV-visible variable-wavelength detector and were detected at their maximum absorbance, resulting in maximum sensitivity. Lipid-soluble vitamins and carotene were resolved in extracts obtained from oils and butter, thus permitting their identification in a single chromatographic run.  相似文献   

14.
Microcolumn liquid chromatography with gradient elution and on-line flame photometric detection has been used for the selective and rapid determination of non-volatile alkylphosphonic acids, which are hydrolysis products of nerve agents, in aqueous samples. A make-up of water was used to maintain stable introduction of the eluent during a gradient run. The detection limits are strongly dependent on quenching, which is determined by the mass flow of methanol in the eluent. Large-volume injections of 100 microl of aqueous solutions of short- and long-chain alkylphosphonic acids resulted in detection limits in the range 6-800 ng/ml. The repeatability of the retention times and analyte response - peak area or peak height were 0.7-0.9% and 4-11%, respectively. The method was successfully applied to a local tap water sample and an aqueous soil extract.  相似文献   

15.
A rapid, sensitive and reliable high performance liquid chromatographic method coupled with tandem mass spectrometry via electrospray ionization (ESI) source (HPLC-MS/MS) has been developed and validated for the determination of anethole trithione (ATT) in human plasma. Diazepam was employed as the internal standard (IS). Sample extracts following liquid-liquid extraction were injected into the HPLC-MS/MS system. The analyte and IS were eluted isocratically on a C18 column, with a mobile phase consisting of methanol and aqueous ammonium acetate solution (5 mM) (80:20, v/v) .The ions were detected by a triple quadrupole mass spectrometric detector in the positive mode. Quantification was performed using selected reaction monitoring (SRM) of the transitions m/z 240.88 → 197.91 and m/z 285.01 → 193.02 for ATT and for the IS, respectively. The analysis time for each run was 5.0 min. The calibration curve fitted well over the concentration range of 0.02-5 ng mL−1, with the regression equation y = 1.1014x + 0.0003631, r = 0.9992. The intra-batch and inter-batch R.S.D.% were less than 15% at all concentration levels within the calibration range. The recoveries were more than 80%. The present method provides a modern, rapid and robust procedure for the pharmacokinetic study of ATT. Some important pharmacokinetic parameters of ATT in healthy Chinese volunteers are also given for the first time.  相似文献   

16.
An on-line analytical system for the continuous monitoring of malondialdehyde (MDA) was developed. This method involves the use of microdialysis perfusion, on-line derivatization and on-line HPLC analysis. This method gave a linear response for MDA concentrations and HPLC peak areas in the range from 0.051 microM to 2.43 microM. The intra-day (RSD = 1.6-10.5%) and inter-day (RSD = 1.1-9.3%) precisions were acceptable. The average in vitro probe recovery of MDA standard was 18.4 +/- 1.0%. The detection limit was 0.03 microM, corresponding to 0.6 pmol for an injection volume of 20 microl. This method was used for in vitro peroxidation investigations, which provided evidence for elevated MDA levels following the incubation of metal ions to a linoleic acid solution.  相似文献   

17.
18.
An original method based on liquid chromatography with single quadrupole electrospray ionization mass spectrometry was developed for the determination of sunitinib in human plasma. The quantitation limit of the method at 0.10 ng/mL is comparable to that of tandem mass spectrometry assays. The handling of all solutions containing sunitinib was performed under low‐intensity red light to avoid the isomerization of sunitinib and enable quantitation using a single peak. Liquid–liquid extraction with a mixture of n‐hexane/isopropanol (90:10 v/v) allowed recoveries at the level of 70%. Measurements were performed using a Zorbax SB‐C18 column (3.0 mm × 150 mm, 3.5 μm) and isocratic elution with (A) 0.1% aqueous formic acid and (B) acetonitrile/methanol (80:20 v/v) in an A/B ratio of 55:45 at 35°C. Under these conditions, sunitinib is eluted at 3.8 min in 6 min of the total run time. The linearity of the calibration curve ranges from 0.10 to 150 ng/mL. The baseline separation of sunitinib and its primary metabolite, Ndes‐ethyl sunitinib (SU12662), as well as sharp peak shapes, suggest a possibility of extending the applied methodology to the quantitative determination of both compounds. Isotopically labeled sunitinib was used as the internal standard. All required validation tests met the acceptance criteria and proved the method's reliability and robustness. The method may be conveniently applied to study the pharmacokinetics of sunitinib in humans.  相似文献   

19.
A new, sensitive and selective detection method for vitamin K1 in human serum is reported. After the chromatographic separation, vitamin K is converted to its hydroquinone form in a wet-chemical post-column reduction reaction with tetramethylammonium octahydridotriborate. The reaction proceeds in an open tubular knitted reaction coil at elevated temperature. This system, when combined with a two-step multidimensional liquid chromatographic separation, has proven useful for the quantitative determination of serum concentrations of vitamin K1 in normal, healthy individuals.  相似文献   

20.
Summary The supercritical-fluid extraction of vitamins D2 and D3 with carbon dioxide is reported for the first time. The extraction recovery was enhanced by direct addition of diethyl ether to sample contained in the extraction cell. Separation and detection of the analytes was performed off-line by reversed-phase liquid chromatography with UV-detection. The quantification limit of the method is 4.1 μg for both analytes, with precision, expressed as relative standard deviation, of 3.8 and 6.3% for vitamins D2 and D3, respectively (η=7). The proposed method has been applied to the determination of vitamin D in different pharmaceutical products; recoveries were between 85 and 105%.  相似文献   