首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Selenomethionine content of candidate reference materials   总被引:1,自引:0,他引:1  
Selenium has been identified as an antioxidant of importance in the diet. Accurate determination of its chemical forms depends on the availability of suitable reference materials (RMs). Two candidate reference materials for determination of selenomethionine (Semet) in food-related materials, a standard wheat gluten sample (NIST RM 8418 Wheat Gluten) and a commercial selenium enriched yeast, have been examined by use of a gas chromatography–isotope dilution mass spectrometry (IDMS) procedure, after treatment of the matrix with 0.1 mol L–1 hydrochloric acid containing stannous chloride, addition of CNBr, and extraction with chloroform. This procedure results in cleavage of the CH3Se group to form volatile CH3SeCN. Addition of isotopically enriched 74Semet to an analytical sample enables estimation of the naturally occurring protein-bound 80Semet by IDMS without a protein-digestion process. We found that the Wheat Gluten RM contains a significant amount of Semet as a portion of its assigned value of 2.58 μg Setotal g–1. Commercial selenium yeast tablets are labeled as containing an elevated level of “organic selenium”, usually as Semet. The sample we investigated contained 210 μg Setotal g–1 sample as determined separately by IDMS, measuring elemental selenium after digestion. 73% of this total (153±21 μg SeSemet g–1; n = 23) was present as Semet. Thus, these two materials contain significant amounts of their total selenium content as Semet and would be good candidates for further study and characterization as reference materials for determining this important food component. The CNBr reaction used will also enable the determination of Se-(methyl)selenocysteine, the biological role of which is of recent interest. In addition to matrix RMs for Semet, it is important to have standard materials of the pure substance. We have examined a sample of a candidate standard material of selenomethionine being prepared by the USP. It was confirmed that this material is pure selenomethionine. Received: 13 December 2000 / Revised: 5 March 2001 / Accepted: 12 March 2001  相似文献   

2.
Selenomethionine contents of NIST wheat reference materials   总被引:1,自引:0,他引:1  
Values of the total selenium and selenomethionine (Semet) content of four wheat-based reference materials have been obtained by gas chromatography-stable isotope dilution mass spectrometry methods. The total Se method is an established one, and the results obtained with it are consistent with previously-assigned values. The Semet method (previously reported by our laboratory) is based on reaction with CNBr. Our data indicate that the four wheat samples (wheat gluten, durum wheat, hard red spring wheat, and soft winter wheat), though having a 30-fold range in total Se content, all have about 45% of their total Se values in the form of selenomethionine. Investigation of the CNBr-based method suggests that additional experiments are needed to verify that all selenomethionine in the wheat samples is accounted for, but also indicates that the values obtained are within 15% of the true values. As the form in which Se occurs in foods and dietary supplements is important from a nutritional perspective, adding information about Se speciation to total Se values in appropriate reference materials makes these materials more valuable in relevant analytical work.  相似文献   

3.
A number of food-matrix reference materials (RMs) are available from the National Institute of Standards and Technology (NIST) and from Agriculture Canada through NIST. Most of these materials were originally value-assigned for their elemental composition (major, minor, and trace elements), but no additional nutritional information was provided. Two of the materials were certified for selected organic constituents. Ten of these materials (Standard Reference Material [SRM] 1,563 Cholesterol and Fat-Soluble Vitamins in Coconut Oil [Natural and Fortified], SRM 1,566b Oyster Tissue, SRM 1,570a Spinach Leaves, SRM 1,974a Organics in Mussel Tissue (Mytilus edulis), RM 8,415 Whole Egg Powder, RM 8,418 Wheat Gluten, RM 8,432 Corn Starch, RM 8,433 Corn Bran, RM 8,435 Whole Milk Powder, and RM 8,436 Durum Wheat Flour) were recently distributed by NIST to 4 laboratories with expertise in food analysis for the measurement of proximates (solids, fat, protein, etc.), calories, and total dietary fiber, as appropriate. SRM 1846 Infant Formula was distributed as a quality control sample for the proximates and for analysis for individual fatty acids. Two of the materials (Whole Egg Powder and Whole Milk Powder) were distributed in an earlier interlaboratory comparison exercise in which they were analyzed for several vitamins. Value assignment of analyte concentrations in these 11 SRMs and RMs, based on analyses by the collaborating laboratories, is described in this paper. These materials are intended primarily for validation of analytical methods for the measurement of nutrients in foods of similar composition (based on AOAC INTERNATIONAL's fat-protein-carbohydrate triangle). They may also be used as "primary control materials" in the value assignment of in-house control materials of similar composition. The addition of proximate information for 10 existing reference materials means that RMs are now available from NIST with assigned values for proximates in 6 of the 9 sectors of the AOAC triangle. Five of these materials have values assigned for total dietary fiber-the first such information provided for materials available from NIST.  相似文献   

4.
Summary Ten new Agricultural/Food Reference Materials (RMs) were characterized with respect to their elemental compositions via an interlaboratory characterization (certification) campaign. Chemical analyses were conducted in 73 cooperating laboratories applying 13 major classes of independently different analytical methods. A total of 213 best estimate values, and 65 informational values were obtained for Al, As, B, Ba, Br, Ca, Cd, Cl, Co, Cr, Cs, Cu, F, Fe, Hg, I, K, Mg, Mn, Mo, N, Na, Ni, P, Pb, Rb, S, Sb, Se, Sr, Ti, V, W and Zn in the following RMs: Bovine Muscle Powder (NIST RM 8414), Whole Egg Powder (NIST RM 8415), Microcrystalline Cellulose (NIST RM 8416), Wheat Gluten (NIST RM 8418), Corn Starch (NIST RM 8432), Corn Bran (NIST RM 8433), Whole Milk Powder (NIST RM 8435), Durum Wheat Flour (NIST RM 8436), Hard Red Spring Wheat Flour (NIST RM 8437) and Soft Winter Wheat Flour (NIST RM 8438).  相似文献   

5.
Selenium species, selenite, selenate, selenomethionine (Semet), seneloethionine (Seet) and trimethylselenonium ion (TmSe) were separated in aqueous solution using a gel-permeation (polyvinyl alcohol-based resin) GS-220 column by eluting with 25 mM tetramethylammonium hydroxide and 25 mM malonic acid at pH 7.9. The GS-220 column coupled with inductively coupled plasma mass spectrometry was used for the separation, identification, and quantification of selenium compounds present in certified reference material (CRM) No. 18 human urine from the National Institute for Environmental Studies in Japan (NIES). Spiking of the authentic standard to the urine and use of a silica-based LC-SCX cation-exchange column validated the peak of selenium compounds. High concentrations of chloride and bromide in the urine eluted from the GS-220 column formed molecular ions 40Ar37Cl+ and 81Br1H+ in the plasma, and these molecular ions created additional peaks in the chromatograms when 77Se and 82Se isotopes were monitored respectively. Thus, both the isotopes were selected concurrently for signal monitoring to eliminate the interfering signals. On the LC-SCX column, chloride and bromide were eluted with selenate and complicated its determination, but the peak of TmSe was baseline separated from rest of the Se compounds. Two unknown Se compounds were detected in both the columns. An additional Se compound having the same retention time as that of Semet was detected on the LC-SCX column. Peaks of selenite, selenate, TmSe and unknown selenium compounds in the urine were baseline separated on the GS-220 column, and were free from interferences. Therefore, the GS-220 column was used for the determination of selenium compounds in NIES CRM No. 18. Unknown Se compounds were the predominant selenium species followed by selenite, TmSe and selenate. The estimated value of TmSe as Se, by the standard additions method using the GS-220 column, was 3.42 +/- 0.17 microg l(-1) and was in good agreement with the LC-SCX value [3.38 +/- 0.21 (n=5) microg l(-1)].  相似文献   

6.
Updated estimates of the selenomethionine content of four NIST wheat reference materials have been obtained by use of a revised gas chromatography–stable-isotope dilution mass spectrometric method. The revised method makes use of digestion with methanesulfonic acid, which enables more complete recovery of endogenous selenomethionine than was previously achieved by overnight denaturing treatment in 0.1 mol L−1 HCl. The NIST wheat reference materials each contain approximately 55% of their total Se content as selenomethionine. Information about forms of Se in reference materials adds value to these materials in Se speciation studies. Estimates of selenomethionine content are also provided for other wheat samples, including several grown under conditions of exposure to high Se levels. These samples also contain approximately 55% of their total Se content as selenomethionine. The consistent level of 55% of total selenium occurring in the form of selenomethionine when the total selenium content varies by a factor of 500 is suggestive of an active mechanism of incorporation of selenium into wheat grain. Figure Selenomethionine content of wheat samples  相似文献   

7.
Twelve biological-matrix, agricultural/food reference materials, Corn Stalk (Zea Mays) (NIST RM 8412), Corn Kernel (Zea Mays) (NIST RM 8413), Bovine Musele Powder (NIST RM 8414), Whole Egg Powder (NIST RM 8415), Microcrystalline Cellulose (NIST RM 8416), Wheat Gluten (NIST RM 8418), Corn Starch (NIST RM 8432), Corn Bran (NIST RM 8433), Whole Milk Powder (NIST RM 8435), Durum Wheat Flour (NIST RM 8436), Hard Red Spring Wheat Flour (NIST RM 8437) and Soft Winter Wheat Flour (NIST RM 8438) were developed. They were characterized with respect to elemental composition via two extensive international interlaboratory characterization campaigns providing 303 reference and informational concentration values for 34 elements (Al, As, B, Ba, Br, Ca, Cd, Cl, Co, Cr, Cs, Cu, F, Fe, Hg, I, K, Mg, Mn, Mo, N, Na, Ni, P, Pb, Rb, S, Sb, Se, Sr, Ti, V, W, Zn) of nutritional, toxicological, and environmental significance. These products are available to the analytical community, for quality control of elemental composition analytical data, from the Standard Reference Materials Program, National Institute of Standards and Technology, Gaithersburg, MD, USA.  相似文献   

8.
A simple solid phase extraction procedure for speciation of selenium(IV) and selenium(VI) in environmental samples has been proposed prior to graphite furnace atomic absorption spectrometry. The method is based on the solid phase extraction of the selenium(IV)-ammonium pyrrolidine dithiocarbamate (APDC) chelate on the Diaion HP-2MG. After reduction of Se(VI) by heating the samples in the microwave oven with 4 mol l−1 HCl, the system was applied to the total selenium. Se(VI) was calculated as the difference between the total selenium content and Se(IV) content. The experimental parameters, pH, amounts of reagents, eluent type and sample volume were optimized. The recoveries of analytes were found greater than 95%. No appreciable matrix effects were observed. The adsorption capacity of sorbent was 5.20 mg g−1 Se (IV). The detection limit of Se (IV) (3sigma, n = 11) is 0.010 μg l−1. The preconcentration factor for the presented system was 100. The proposed method was applied to the speciation of selenium(IV), selenium(VI) and determination of total selenium in natural waters and microwave digested soil, garlic, onion, rice, wheat and hazelnut samples harvested various locations in Turkey with satisfactory results. In order to verify the accuracy of the method, certified reference materials (NIST SRM 2711 Montana Soil, NIST SRM 1568a Rice Flour and NIST SRM 8418 Wheat Gluten) were analyzed and the results obtained were in good agreement with the certified values. The relative errors and relative standard deviations were below 6 and 10%, respectively.  相似文献   

9.
Summary Three wheat flours, Durum Wheat Flour (NIST RM 8436), Hard Red Spring Wheat Flour (NIST RM 8437), Soft Winter Wheat Flour (NIST RM 8438) and Wheat Gluten (NIST RM 8418) Reference Materials were characterized for essential and toxic major, minor and trace elemental composition by analysts in an interlaboratory cooperative characterization campaign. Extensive application of widely varied analytical methods yielded 16–27 best estimate and 3–8 informational concentration values for each of these materials. These reference materials are intended for analytical quality control of element determinations in flour and flour products as well as other agricultural/food materials with related matrices.Contribution No. 92–145 from Centre for Land and Biological Resources Research  相似文献   

10.
An on-line FIA pretreatment with HBr/KBrO3, assisted by on-line focused microwave-induced digestion, has been coupled with hydride generation-atomic absorption spectrometry (HG-AAS) for final detection for total selenium determination. This total selenium determination is virtually independent of the different Se species investigated (selenite, selenate, selenomethionine, selenoethionine and selenocystine). Detection limits of 0.8 μg l−1 of Se can be achieved by AAS with precisions better than 5%. This continuous flow system for selenium determination allows a high sample throughput (about 30 samples h−1 can be analyzed) in which high automation can be achieved and constitutes a convenient real-time continuous detector for the different selenocompounds tested. Direct non-chromatographic speciation of inorganic selenium (selenite and selenate in their mixtures) is demonstrated by simple on-off operation of the focused microwaves connected in the flow system.

Validation of this simple on-line FIA system has been carried out by analyzing total Se recovered from spiked tap waters and by speciating mixtures of Se(IV) and Se(VI) spiked to the same samples. The fast conversion of Se compounds into volatile selenium could be considered as a sort of specific “general” detector for Se compounds which can be extremely useful for Se speciation by hybrid chromatographic techniques.  相似文献   


11.
Pumpkins were treated by spraying the leaves in the flowering period with a water solution containing 1.5 mg Se per liter in the form of Na2SeO4. The average total selenium content of seeds was found to be 0.19 microg g(-1) in nontreated pumpkins and 1.1 microg g(-1) in exposed ones. For speciation analysis, enzymatic hydrolysis with different amounts of Protease XIV was carried out. Under optimal conditions of enzymatic hydrolysis, 90% of the total selenium was found in soluble forms. Separation of species was performed using HPLC on anion and cation exchange columns and for detection UVHG-AFS was applied. In enzymatic hydrolysis extracts, the main fraction of selenium was bound as selenomethionine (SeMet), representing on average of 81 +/- 8% of the total Se content in the sample.  相似文献   

12.
A solid-phase micro-extraction (SPME) method using an SPME fiber device and graphite furnace (GF) for extracting Se compounds was proposed. Various factors affecting the derivatization and extraction of Se(IV) by SPME-GF were evaluated, including the effect of acid (type and concentration), the concentration of the derivatizing agent, the derivatization temperature, the extraction and derivatization times and the extraction temperature. After optimizing these conditions, the quantification of Se(IV) was performed by Gas Chromatography-Mass Spectrometry (GC-MS). The limit of detection was 0.37 μg L(-1) for Se(IV). The method was successfully applied to the total Se determination in certified reference materials (BCR-414 and SRM 1643e). A recovery of 97% was obtained for water (SRM 1643e). After microwave oven decomposition and the reduction of selenium using a mixture of 2 mol L(-1) HCl and 1% (w/v) KBr, a recovery of 101% and a relative standard deviation of 3.5% were attained for plankton (BCR-414). The SPME-GF method combined with GC-MS was also applied to the determination of the total selenium in a drug sample (selenium chelate).  相似文献   

13.
A laboratory reference material (LRM) was prepared from Brazil nuts (Bertholletia excelsa) for quality control (QC) purposes of selenium speciation. The preparation of this LRM led through the usual operation steps applied during routine reference material production from biota samples-preparation of the raw material, homogenisation, storage design, checking of homogeneity, microbiological status and possible irradiation effects, and monitoring the species stability vs time at different storage temperatures. The selenium speciation studies to check species stability were carried out on a HPLC-UV-HG-AFS measurement set-up. Special attention was paid to the correct identification of selenium species by applying independent HPLC separation techniques (ion-pairing and anion-exchange chromatography). The concentration of selenomethionine (SeMet) and total Se content were quantified (79.9 microg g(-1) (calculated as Se) and 82.9 microg g(-1), respectively). The homogeneity and stability of this candidate reference material passed the relevant tests recommended by Bureau Communautaire de Référence (BCR).  相似文献   

14.
Results of an international intercomparison study (CCQM-P86) to assess the analytical capabilities of national metrology institutes (NMIs) and selected expert laboratories worldwide to accurately quantitate the mass fraction of selenomethionine (SeMet) and total Se in pharmaceutical tablets of selenised-yeast supplements (produced by Pharma Nord, Denmark) are presented. The study, jointly coordinated by LGC Ltd., UK, and the Institute for National Measurement Standards, National Research Council of Canada (NRCC), was conducted under the auspices of the Comité Consultatif pour la Quantité de Matière (CCQM) Inorganic Analysis Working Group and involved 15 laboratories (from 12 countries), of which ten were NMIs. Apart from a protocol for determination of moisture content and the provision of the certified reference material (CRM) SELM-1 to be used as the quality control sample, no sample preparation/extraction method was prescribed. A variety of approaches was thus used, including single-step and multiple-step enzymatic hydrolysis, enzymatic probe sonication and hydrolysis with methanesulfonic acid for SeMet, as well as microwave-assisted acid digestion and enzymatic probe sonication for total Se. For total Se, detection techniques included inductively coupled plasma (ICP) mass spectrometry (MS) with external calibration, standard additions or isotope dilution MS (IDMS), inductively coupled plasma optical emission spectrometry , flame atomic absorption spectrometry and instrumental neutron activation analysis. For determination of SeMet in the tablets, five NMIs and three academic/institute laboratories (of a total of five) relied upon measurements using IDMS. For species-specific IDMS measurements, an isotopically enriched standard of SeMet (76Se-enriched SeMet) was made available. A novel aspect of this study relies on the approach used to distinguish any errors which arise during analysis of a SeMet calibration solution from those which occur during analysis of the matrix. To help those participants undertaking SeMet analysis to do this, a blind sample in the form of a standard solution of natural abundance SeMet in 0.1 M HCl (with an expected value of 956 mg kg−1 SeMet) was provided. Both high-performance liquid chromatography (HPLC)–ICP-MS or gas chromatography (GC)–ICP-MS and GC-MS techniques were used for quantitation of SeMet. Several advances in analytical methods for determination of SeMet were identified, including the combined use of double IDMS with HPLC-ICP-MS following extraction with methanesulfonic acid and simplified two-step enzymatic hydrolysis with protease/lipase/driselase followed by HPLC-ICP-IDMS, both using a species-specific IDMS approach. Overall, satisfactory agreement amongst participants was achieved; results averaged 337.6 mg kg−1 (n = 13, with a standard deviation of 9.7 mg kg−1) and 561.5 mg kg−1(n = 11, with a standard deviation of 44.3 mg kg−1) with median values of 337.6 and 575.0 mg kg−1 for total Se and SeMet, respectively. Recovery of SeMet from SELM-1 averaged 95.0% (n = 9). The ability of NMIs and expert laboratories worldwide to deliver accurate results for total Se and SeMet in such materials (selensied-yeast tablets containing approximately 300 mg kg−1 Se) with 10% expanded uncertainty was demonstrated. The problems addressed in achieving accurate quantitation of SeMet in this product are representative of those encountered with a wide range of organometallic species in a number of common matrices. Figure Looking into the quantitative speciation of selenium in pharmaceutical supplements Photo courtesy of LGC.  相似文献   

15.
A method for performing rapid semiquantitative screening of the distribution of Se species in the blood of cows fed with a diet enriched in selenized yeast was optimized. The method was based on direct injection of a blood sample onto a high resolution size exclusion chromatographic column and fractionation of the selenium species. Selenium was detected on-line by ICP-MS with a collision cell. The concentrations of selenized haemoglobin and free selenomethionine were estimated using the chromatogram. The method was applied to a study involving 15 control and 15 treated dairy cows at four different supplementation time points. The increase in the selenomethionine and selenized haemoglobin was a linear function of the total selenium concentration. A threshold value of 600 ng ml(-1) of total Se was established beyond which selenomethionine could not be incorporated into the protein. No inorganic selenium was found to be present. The total selenium in cow blood correlated well with that in milk. The selenium supplementation did not change the protein distribution profiles for other essential elements (Cu, Fe, Mn, Zn).  相似文献   

16.
Two sample treatment methods are evaluated to provide accurate boron determination at low concentrations in biological and botanical samples. The first approach is a hot 1M nitric acid extraction of boron from the sample. The second technique uses wet digestion with concentrated sulfuric acid. The accuracy of the procedures was demonstrated with botanical and animal reference materials (Corn Bran RM 8433 and Whole Egg Powder RM 8415). At least three results are given for each reference material. Two are direct measurements of B using independent 10B and 11B calibration curves with a Be internal reference, and the third is obtained by isotope dilution mass spectrometry (IDMS). The 10B and 11B values are consistent for both acid treatment procedures. The IDMS results also are consistent. Overall results for Whole Egg Powder and Corn Bran RM's match the best-estimate values within their confidence intervals. These results demonstrate the ability to measure B accurately at the 0.3 µg/g concentration range. Thus, low-level B samples can be analyzed with accuracy and precision by the two approaches. These methods introduce very little dissolved organic carbon (DOC) in the final solution and allow the use of large (2 g) sample aliquots. Direct introduction of biological fluids including whole blood serum also was evaluated critically for the determination of B.  相似文献   

17.
The coupling of a high-power nitrogen (N2) microwave-induced plasma (MIP) mass spectrometry--(MS) (1.3 kW) with high-performance liquid chromatography, connected with concentric nebulizer (CN), ultrasonic nebulizer (USN) and a hydride generation (HG) systems, for the optimization and determination of selenium compounds, has been carried out. The MIP-MS system fulfils the ideal requirement being an on-line real-time chromatographic detector for Se speciation analysis. Interchanging of MIP-MS system fabricated nebulizer (concentric) with an ultrasonic nebulizer increases about 3.4-12 (peak height) and 6.5-10 (peak area) times ion signals for the selenium compounds. The detection limits for selenate, selenite, trimethylselenonium ion (TmSe), selenomethionine (Semet) and selenoethionine (Seet) (in Milli-Q-water) obtained with the optimized HPLC-USN-N2MIP-MS system are 0.11, 0.14, 0.09, 0.14 and 0.10 microg L(-1), respectively, about 12-48 times lower than the HPLC-CN-MIP-MS and 1.5-4.4 (peak height) times lower compared to the HPLC-CN-inductively coupled plasma (ICP)-MS coupling. Considering peak area, the repeatability (R.S.D. for three successive analyses) and intermediate precision (R.S.D. for three successive analyses performed on three different days), achieved for five Se compounds are 0.8-5.6, and 1.1-5.9%, comparable with the HPLC-CN-ICP-MS, HPLC-HG-MIP-MS and HPLC-CN-MIP-MS systems. The combined HPLC-USN-N2MIP-MS has been adequately applied for the determination of Se compounds in certified National Institute for Environmental studies human urine CRM No. 18. The results reasonably agree with the HPLC-CN-ICP-MS values. This encouraging combination may be an alternative ion source of mass spectrometry for coming generation in regard to the selenium speciation analysis.  相似文献   

18.
The stability of arsenic, selenium, antimony and tellurium species in water and urine (NIST SRM 2670n) as well as in extracts of fish and soil certified reference materials (DORM-2 and NIST SRM 2710) has been investigated. Stability studies were carried out with As(III), As(V), arsenobetaine, monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), phenylarsonic acid (PAA), Se(IV), Se(VI), selenomethionine, Sb(III), Sb(V) and Te(VI). Speciation analysis was performed by on-line coupling of anion exchange high-performance liquid chromatography (HPLC) with inductively coupled plasma mass spectrometry (ICP-MS). Best storage of aqueous mixtures of the examined species was achieved at 3 degrees C whereas at -20 degrees C species transformation especially of selenomethionine and Sb(V) took place and a new selenium species appeared within a period of 30 days. Losses and species transformations during extraction processes were investigated. Extraction of the spiked fish material with methanol/water led to partial conversion of Sb(III), Sb(V) and selenomethionine to two new antimony and one new selenium species. The other arsenic, selenium and tellurium species were almost quantitatively extracted. For soil spiked with MMA, PAA, Se(IV) and Sb(III), recoveries after extraction with water and sulfuric acid (0.01 mol/L) were below 20%.  相似文献   

19.
A microwave digestion method for the determination of marine biological tissues has been developed to allow determination of selenium in small sample sizes (< 0.1 g). The benefits of this technique include maintaining concentrates in extracts without the subsequent over dilution encountered when using larger vessels, increased sample throughput and reduced loss of volatile material. Freeze dried biological material (< 0.1 g) and nitric acid (1 ml) were placed into 7 ml screw top Teflon vessels which are completely sealed on capping. Two 7 ml vials were placed into larger 120 ml vessels fitted with a Teflon spacer and 10 ml of distilled water. The effects of microwave power and time, and sample mass on selenium recovery from three marine standard reference materials (NIST SRM 1566a Oyster Tissue, NRCC DORM-1 Dogfish Muscle and NRCC TORT-1 Lobster Hepatopancreas) were examined. The optimum conditions: 600 W, 2 min; 0 W, 2 min; 450 W, 45 min, allowed quantitative recoveries of selenium from these and three other standard reference materials (NRCC DOLT-1 Dogfish liver, NIST RM-50 Albacore tuna and IAEA MA-A-2 fish flesh). Studies on sample mass showed that the analysis of sample masses from 0.025 to 0.1 g gave selenium concentrations within the certified range. Six species of selenium: selenite, selenate, selenomethionine, selenocysteine, selenocystamine, and trimethyl selenonium were added to oyster, dogfish, and lobster tissues. Recoveries were near quantitative for all species (94–105%) except trimethyl selenonium (90–101%).  相似文献   

20.
An analytical method has been developed for the determination of selenious acid, selenic acid, trimethylselenonium ion, and selenomethionine. The four selenium compounds were separated by HPLC on a column (25 cm×4 mm I.D.) of the anion-exchanger ESA Anion III with a mobile phase (1.5 ml/min) of 0.0055 M ammonium citrate (pH 5.5). Detection was carried out using an on-line inductively coupled plasma mass spectrometer (ICP-MS) or a flame atomic absorption spectrometer (FAAS) as the selenium-specific detector. The chromatographic parameters and the chemical factors affecting the separation of the selenium species were optimized. The four selenium compounds could be separated within 8 minutes. The detection limits of the coupled HPLC–FAAS system were approximately 1 mg Se/l for each compound (100 μl injection), estimated as three times the base-line noise of the chromatograms. More powerful selenium detection was achieved with an ICP-MS. Selenium was measured at m/z 78. To increase the nebulization efficiency, the Meinhard concentric glass nebulizer was replaced by an ultrasonic nebulizer. The ICP-MS signal intensity was increased with the ultrasonic nebulization by a factor of 7 times for selenious acid and 24 to 31 times for trimethylselenonium ion, selenomethionine, and selenic acid compared to that with the Meinhard nebulization. The detection limits achieved by the HPLC–ICP-MS with the ultrasonic nebulization were 0.08 μg Se/l for trimethylselenonium ion, 0.34 μg Se/l for selenious acid, 0.18 μg Se/l for selenomethionine, and 0.07 μg Se/l for selenic acid, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏