首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The isolation of non-volatile organic poisons from biological specimens is often difficult and time consuming. This paper surveys the isolation of common drugs and pesticides from biological specimens, including serum, blood and tissue, and the effect of experimental variables on the recovery of compounds, with emphasis on recent trends in extraction techniques and new methods under development, particularly those applicable to forensic toxicology. Traditional liquid-liquid extraction techniques are increasingly being replaced by or used in combination with newer extraction techniques such as solid-phase and supercritical fluid extraction. The potential advantages and problems encountered when incorporating these new methodologies in the isolation of drugs and pesticides from biological matrices are discussed. Although early implementation of solid-phase extraction techniques in forensic toxicology has been hampered by a variety of problems, including extract quality, reproducibility and selectivity, improvements in sorbent quality and elution solvents continue to facilitate their replacement of traditional liquid-liquid extraction methods. Future developments in supercritical fluid extraction should allow this technique to develop in an extremely powerful quantitative tool for the isolation of drugs and pesticides either from solid-phase sorbents or from their endogenous matrices.  相似文献   

2.
A new analytical strategy to screen for endocrine-disrupting chemicals (EDCs) in environmental matrices is presented. The strategy uses solid-phase extraction followed by large volume injection and capillary gas chromatography coupled to mass spectrometry combined with retention time locking libraries (SPE-LVI-GC-MS-RTL). Characterization of the proposed methodology (SPE-LVI-GC-MS) for selected classes of EDCs enabled high reproducibility and robustness at the ultratrace level. The RTL databases used allowed hundreds of non-target semivolatiles (i.e., pesticides, polycyclic aromatic hydrocarbons, polychlorinated biphenyls and other classes of suspected EDCs from a great number of unknown environmental matrices) to be simultaneously screened for in an easy, fast and remarkable manner. The application of the proposed methodology to real environmental samples demonstrated its remarkable selectivity and sensitivity at the ultratrace level. Screening assessments performed on water and sediment matrices from eight Portuguese estuaries and coastal waters identified EDC "hotspots." These EDCs mainly come from agricultural and a wide variety of industrial sources, and include pesticides and pesticide metabolites, phenolic derivatives and polycyclic aromatic hydrocarbons, which are included in the lists of priority substances published by international environmental agencies. The estuaries that contained relatively high levels of pesticides were Guadiana, Sado and Mondego, while Minho, Douro and Formosa showed enhanced levels of phenolic derivatives. Dibutyltin and tributyltin, selected as target compounds to be monitored by SPE-LVI-GC-MS in the selected ion monitoring mode, were shown to be widespread contaminants at trace levels in almost all of the sediment matrices assessed. The reliability of the proposed methodology undoubtedly makes it a valuable tool that could replace other analytical strategies currently used to screen for EDCs present in the environment at ultratrace levels.  相似文献   

3.
The availability of a sensitive and rapid analytical method for the determination of opiates, and other substances of forensic interest, in a variety of biological specimens is of utmost importance to forensic laboratories. Solid-phase extraction is very popular in the pre-treatment of forensic samples. Nevertheless, a new approach, disposable pipette extraction (DPX), is gaining increasing interest in sample preparation. DPX has already been applied to the analysis of drugs of abuse in common biological matrices, such as urine and blood, but has not yet been evaluated on alternative biological samples, such as vitreous humor. The objective of this study was to evaluate the applicability of DPX on the analysis of opiates in vitreous humor. The currently developed method is fast, reliable, and easy to perform. The sensitivity, precision, and accuracy are satisfactory. Recoveries obtained are within the range of 72-91%, whereas the sample volume of vitreous humor required is only 100 μL.  相似文献   

4.
In Japan, not only the classical stimulant, methamphetamine, but also a wide variety of illicit drugs and designer drugs are abused by juveniles. It is, however, difficult to screen these drugs in human urine due to the poor availability of high-quality standards. Therefore, it is important to develop a screening method that does not require the use of standard compounds. Furthermore, if we can obtain approximate drug concentrations in biological fluids by the first screening procedure, the subsequent treatment of the patient and forensic diagnosis can be carried out more rapidly and exact quantitative analysis performed more efficiently. We have devised a rapid screening method for the simultaneous semi-quantitative analysis of 30 abused drugs using gas chromatography/mass spectrometry (GC/MS) with a retention time locking technique. Based on this method, an 'abused drugs database' was constructed including retention time (RT), qualifier ion/target ion (QT) percentage and calibration curve (values of slope and intercept) using the novel GC/MS software, NAGINATA. We compared the analytical results obtained by this method using the constructed database with those from conventional methods in six forensic cases. The number of confirmed drugs and concentrations obtained by the established method was comparable with that obtained by conventional methods. We found a significant improvement in the time for data analysis, and qualitative and quantitative information about each drug was obtained without using standards. Therefore, this new screening procedure using NAGINATA has potential for the rapid identification of poisoning and should be useful in clinical and forensic toxicological analyses.  相似文献   

5.
With its highly fluctuating ion production matrix-assisted laser desorption/ionization (MALDI) poses many practical challenges for its application in mass spectrometry. Instrument tuning and quantitative ion abundance measurements using ion signal alone depend on a stable ion beam. Liquid MALDI matrices have been shown to be a promising alternative to the commonly used solid matrices. Their application in areas where a stable ion current is essential has been discussed but only limited data have been provided to demonstrate their practical use and advantages in the formation of stable MALDI ion beams. In this article we present experimental data showing high MALDI ion beam stability over more than two orders of magnitude at high analytical sensitivity (low femtomole amount prepared) for quantitative peptide abundance measurements and instrument tuning in a MALDI Q-TOF mass spectrometer. Samples were deposited on an inexpensive conductive hydrophobic surface and shrunk to droplets <10 nL in size. By using a sample droplet <10 nL it was possible to acquire data from a single irradiated spot for roughly 10,000 shots with little variation in ion signal intensity at a laser repetition rate of 5-20 Hz.  相似文献   

6.
Selected precursors and degradation products of chemical warfare agents namely N,N-dialkylaminoethane-2-ols, N,N-dialkylaminoethyl-2-chlorides and some of related N-quaternary salts were studied by means of electrospray ionization-multiple tandem mass spectrometry (ESI-MS(n)). Proposed structures were confirmed with accurate mass measurement. General fragmentation patterns of these compounds are discussed in detail and suggested processes are confirmed using deuterated standards. The typical processes are elimination of alkene, hydrogen chloride, or water, respectively. Besides, elimination of ethene from propyl chain under specific conditions was observed and unambiguously confirmed using exact mass measurement and labelled standard. The potential of mass spectrometry to distinguish the positional isomers occurring among the studied compounds is reviewed in detail using two different MS instruments (i.e. ion trap and hybrid quadrupole-time of flight (Q-TOF) analyzer). A new microcolumn liquid chromatography (microLC)/MS(n) method was designed for the cases where the resolution based solely on differences in fragmentation is not sufficient. Low retention of the derivatives on reversed phase (RP) was overcome by using addition of less typical ion pairing agent (1 mM/l, 3,5-dinitrobenzoic acid) to the mobile phase (mixture water : acetonitrile).  相似文献   

7.
杨吉双  张庆合  苏立强 《色谱》2020,38(12):1369-1380
有机磷酸酯(OPEs)是阻燃剂和塑化剂的主要原料,通常以添加形式存在于各种材料中,在生产和使用过程中伴随磨损和挥发易释放到环境中,现已成为新兴污染物。因为该类化合物的神经毒性、致癌性、破坏内分泌系统以及生殖系统等毒性,食品样品中OPEs的检测成为近年来关注的热点。该文重点围绕食品基质中OPEs检测存在的含量低、本底干扰严重、缺乏灵敏可靠分析方法等问题,对OPEs类化合物的性质、样品前处理、检测技术、质量控制等进行了全面评述。首先总结了30余种常见OPEs类化合物的类型、官能团、极性、沸点等理化性质,对可能的前处理和检测技术进行了理论分析;其次梳理了加速溶剂萃取(ASE)、基质固相分散萃取(MSPD)、微波辅助萃取(MAE)、超声辅助萃取(UAE)、QuEChERS、固相萃取(SPE)、凝胶渗透色谱(GPC)、分散固相萃取(d-SPE)等前处理方法在食品中OPEs化合物分析中的特点,其中UAE和QuEChERS结合多步净化能够有效降低高脂类食品的基质效应,具有良好应用前景;此外比较了气相色谱和液相色谱在分离和检测方面的优缺点,比较已有文献的检出限、回收率等数据;概括了标准品和内标物来源、过程污染与基质效应的产生原因和预防措施;最后对高分辨质谱筛查和鉴别OPEs未知代谢物,以及相关分析方法趋势进行了展望。  相似文献   

8.
Natural product analysis has gained wide attention in recent years, especially for herbal medicines, which contain complex ingredients and play a significant clinical role in the therapy of numerous diseases. The constituents of natural products are usually found at low concentrations, and the matrices are complex. Thus, the extraction of target compounds from natural products before analysis by analytical instruments is very significant for human health and its wide application. The commonly used traditional extraction methods are time-consuming, using large amounts of sample and organic solvents, as well as expensive and inefficient. Recently, microextraction techniques have been used for natural product extraction to overcome the disadvantages of conventional extraction methods. In this paper, the successful applications of and recent developments in microextraction techniques including solvent-based and sorbent-based microextraction methods, in natural product analysis in recent years, especially in the last 5 years, are reviewed for the first time. Their features, advantages, disadvantages, and future development trends are also discussed.  相似文献   

9.
One of the oldest groups of veterinary chemotherapeutic agents, sulfonamides have been widely used for more than 50 years, thanks to their low cost and their broad spectrum of activity in preventing or treating bacterial infections. Nowadays, those compounds are regularly detected in a wide variety of environmental samples, including natural waters, sediments and soils. Since the environmental concentrations of sulfonamides are usually very low and their occurrence multicomponental, their determination in these matrices still pose significant analytical problems. The present paper describes the optimization of ESI-MS/MS parameters and the chromatographic separation of 12 sulfonamides commonly used in veterinary medicine. The methodology developed in this study, unlike many others, satisfied the requirements of EU Commission Decision 2002/657/EC, which defines the criteria for both screening and confirmatory methods with respect to drug residues on the basis of identification points. Each MRM transition was tested not only for the qualitative but also for the quantitative analysis of sulfonamides. The method was validated for its analytical performance parameters and applied to the determination of those compounds in soil samples.  相似文献   

10.
A new HPLC method for the fully automatic determination of aromatic sulfonates in aqueous samples is presented. The analytical procedure consists of an on-line combination of ion-pair extraction (IPE) and ion-pair chromatography (IPC), both using RP-C18 solid-phase material and a tetrabutylammonium salt as ion pairing reagent. Experimental details and performance data are given. This method is suited for the trace-level determination of a wide variety of benzene, naphthalene, anthraquinone and stilbene sulfonates. Detection limits for surface water using a diode-array detector are in the sub-ppb range. For naphthalene sulfonates a very good selectivity and minimal detectable limits of 0.02 μg/L or even lower can be achieved. So far, this method has been successfully applied to waste water, river water, bank filtrate, and water from different steps of drinking water production. The fate of several aromatic sulfonates has been studied beginning at the effluents of industrial waste water treatment plants and ending after activated carbon filtration in a water works. Napthalene-1,5-disulfonate (NDS, Armstrong acid) and cis-4,4′-dinitrostilbene-2,2′-disulfonate (DNS) appear in the raw water of the investigated water works and therefore have to be termed as relevant to water works. In contrast to other disulfonates NDS is extremely stable to biodegradation and ozonation and it is even desorbed from a highly loaded activated carbon filter.  相似文献   

11.
The ability to rapidly identify the taxonomic class of the wide variety of microorganisms involved in human and animal disease is becoming increasingly important, especially with the increasing development of resistance to the antibiotics which form the main defence against them. A number of groups have recognised the utility of matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry MALDI-TOF in the analysis of these microorganisms. However, no consistent methodology has been developed which is in general use. In particular the use of different solvent extraction systems and mass spectrometric matrices can have significant effects on the quality of the data obtained. We have now studied a number of the commonly used matrices and a range of solvent systems of widely varying polarity in an attempt to devise an optimum analytical strategy for the rapid characterisation of these organisms by MALDI-TOFMS. The E. coli ATCC 9637 organisms were initially washed to remove growth medium contaminants, followed by extraction with one of a range of solvents prior to admixing with a number of different single matrices or binary and ternary combinations of these matrices. The results obtained indicate that a binary combination of 2-(4-hydroxyphenylazo)benzoic acid and 2-mercaptobenzothiazole (1:1) as matrix provides the best data after the proteinaceous material from the organism cell surface was extracted with 17% formic acid, 33% isopropyl alcohol and 50% water, (solvent 2 in this work).  相似文献   

12.
This review updates our knowledge about pressurised liquid extraction (PLE) and subcritical water extraction (SWE), two sample preparation techniques which are increasingly used for the extraction of moderately and non-volatile organic pollutants from a variety of solid and semi-solid environmental matrices. Parameters influencing the extraction yield and selectivity are discussed. The results deriving from the analysis of several different classes of compounds in a variety of matrices are compared with a reference method, e.g., Soxhlet extraction. PLE and SWE are both promising techniques due to the short extraction times and low solvent consumption. In addition, SWE offers a wide range of polarities by changing the temperature and can easily provide class-selective extraction by temperature programming and/or the addition of modifier(s). This indicates that, even though many applications have already been reported, more can be expected.  相似文献   

13.
Development of efficient methods for isolation and separation of biologically active compounds remains an important challenge for researchers. Designing systems such as organomineral composite materials that allow extraction of a wide range of biologically active compounds, acting as broad-utility solid-phase extraction agents, remains an important and necessary task. Selective sorbents can be easily used for highly selective and reliable extraction of specific components present in complex matrices. Herein, state-of-the-art approaches for selective isolation, preconcentration, and separation of biologically active compounds from a range of matrices are discussed. Primary focus is given to novel extraction methods for some biologically active compounds including cyclic polyols, flavonoids, and oligosaccharides from plants. In addition, application of silica-, carbon-, and polymer-based solid-phase extraction adsorbents and membrane extraction for selective separation of these compounds is discussed. Potential separation process interactions are recommended; their understanding is of utmost importance for the creation of optimal conditions to extract biologically active compounds including those with estrogenic properties.  相似文献   

14.
A new method based on solid phase dispersion-pressurized liquid extraction (PLE) followed by gas chromatography-mass spectrometry (GC-MS) has been developed for the determination of 26 suspected fragrance allergens (all the regulated in the EU Cosmetics Directive amenable by GC, as well as pinene and methyleugenol) in cosmetic samples. The effects of the temperature, extraction time and solvent, and dispersing sorbent, affecting the whole proposed procedure, have been evaluated using a multifactor strategy. The optima conditions after the analysis of main and second order effects entailed the extraction at 120°C for 15 min, using hexane/acetone as solvent, and florisil as dispersing sorbent. The method performance has been studied, showing good linearity (R≥0.996) as well as good precision (RSD≤10%). Detection limits (S/N=3) ranged from 0.000001 to 0.0002% (w/w), values far below the established restrictions as regard labelling in the European Cosmetics Regulation. Reliability was demonstrated through the quantitative recoveries of all the studied compounds. The absence of matrix effects allowed quantification of the compounds by calibration with standard solutions. The analysis of 10 samples (several moisturizing and anti-wrinkle creams and lotions, hand creams, and sunscreen and after-sun creams), covering very different matrices, showed the presence of suspected allergens in all the analyzed samples; in fact, half of the samples contained an elevated number of them. Although the ubiquity of these compounds was demonstrated, labelling was in all cases in consonance with the European Cosmetics Regulation.  相似文献   

15.
An electrospray ionization tandem mass spectrometry (ESI-MS/MS) library which contains over 5,600 spectra of 1,253 compounds relevant in clinical and forensic toxicology has been developed using a hybrid tandem mass spectrometer with a linear ion trap. Pure compound solutions—in some cases solutions made of tablets—were prepared and 1 to 2,000 ng of each compound were injected into the system using standard reversed-phase analytical columns with gradient elution. To obtain maximum mass spectral information enhanced product ion spectra were acquired with positive and/or negative ionization at low, medium, and high collision energies and additionally applying collision energy spread. In this mode, all product ions generated by the different collision energies are trapped in the linear ion trap prior to their detection. The applicability of the library for other types of hybrid tandem mass spectrometers with a linear ion trap of the same manufacturer as well as a standard triple-quadrupole tandem mass spectrometer has been investigated with a selection of compounds. The spectra of the developed library can be used to create methods for target analysis, either screening methods or quantitative procedures by generating transitions for multiple reaction monitoring. For those procedures, suitable transitions and convenient collision energies are selected from the library. It also has been utilized to identify compounds with a multi target screening approach for clinical and forensic toxicology with a standardized and automated system. The novel aspects compared to our former library produced with a standard triple-quadrupole mass spectrometer are the enlargement of the ESI-MS/MS library and the additional acquisition of spectra with collision energy spread.  相似文献   

16.
As a response to a recent emergency case of suspected deliberate contamination of bottled drinking water addressed to sensitive personalities, samples were submitted to our laboratory for investigation; an analytical framework for wide screening and identification of unknown hazardous chemicals and microbiological agents in water has been developed and experienced for the purpose. The proposed approach combines several physico-chemical (inverse-phase liquid chromatography with spectrophotometric or mass spectrometric detection, suppressed ion chromatography, inductively coupled plasma-optical emission spectrometry, gas chromatography with mass spectrometric detection), microbiological (defined substrate technology) and biological assays (viability and macromolecular synthesis of cultured cells), thus allowing the detection of different classes of contaminants (inorganic and organic compounds, metals, algal toxins, bacterial indicators of faecal contamination, enteric pathogens, staphylococci, actinomycetes) and their effects.The application of the developed strategy to the suspected samples did not highlight the presence of specific and considerable risks for human health although a few organoleptic and microbiological parameters were compromised and water was not suitable for human consumption. Therefore, we were able to classify this episode as a water contamination threat instead of confirming an incident.The proposed screening-confirmatory analytical scheme can be a valuable tool for obtaining conclusive and relatively rapid results in investigations concerning accidental or intentional contamination of drinking water.  相似文献   

17.
The presence of pollutants and their transformation products (TPs) in the water system is a big concern because of possible adverse effects on the aquatic environment. Their identification is still a challenge that requires the combination of different chromatographic techniques. In the current research, serial coupling of RPLC and zwitterionic hydrophilic interaction LC with TOF‐MS was investigated as a single separation technique for the screening of suspected TPs from electrochemical oxidation of diclofenac using a boron‐doped diamond electrode. Diclofenac oxidation was performed in three water matrices in order to study its transformation in different chemical contexts. 47 TPs resulting from similar oxidation methods were selected from the literature. As in most cases standards were not available, an identification procedure based on accurate mass data and chromatographic behavior was proposed. According to this procedure, 11 suspected TPs, previously analyzed by LC, GC, or ion chromatography, were detected in a single injection. The method was proved to be reliable and versatile and it could be efficiently employed as a comprehensive analytical tool for the simultaneous analysis of compounds in a wide polarity range.  相似文献   

18.
We established an analytical method based on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) in the precursor ion mode for simultaneous qualitative monitoring of various groups of cyanobacterial toxins. The toxin groups investigated were paralytic shellfish poisoning (PSP) toxins, anatoxins (ANAs), cylindrospermopsins (CYNs), microcystins (MCs), and nodularins (NODs), including rare and uncharacterized derivatives found in plankton and water matrices. Alternative analytical methods based on tandem mass spectrometry commonly operate in multiple reaction monitoring (MRM) mode and depend on prior knowledge of putative toxigenicity of the cyanobacterium species and strain, and the expected toxin variants. In contrast, the precursor ion mode yields diagnostic mass fragments for the detection of characteristic compounds of the different toxin classes and thus allows monitoring of a large set of unspecified cyanotoxins of various groups, even when the species composition is undetermined or uncertain. This rapid method enables screening for a wide spectrum of toxic cyanobacterial metabolites and degradation products in a single chromatographic separation with detection limits at nanogram levels. The precursor ion technique is a valuable adjunct to existing mass spectrometric methods for cyanotoxins, although it is not a complete replacement for detailed quantitative analysis requiring comprehensive sample cleanup.  相似文献   

19.
Recent years have seen the development of powerful technologies that have provided forensic scientists with new analytical capabilities, unimaginable only a few years ago. With liquid chromatography-mass spectrometry (LC-MS) in particular, there has been an explosion in the range of new products available for solving many analytical problems, especially for those applications in which non-volatile, labile and/or high molecular weight compounds are being analysed. The aim of this article is to present an overview of some of the most recent applications of LC-MS (/MS) to forensic analysis. To this end, our survey encompasses the period from 2002 to 2005 and focuses on trace analysis (including chemical warfare agents, explosives and dyes), the use of alternative specimens for monitoring drugs of abuse, systematic toxicological analysis and high-throughput analysis. It is not the intention to provide an exhaustive review of the literature but rather to provide the reader with a 'flavour' of the versatility and utility of the technique within the forensic sciences.  相似文献   

20.
Inductively coupled plasma (ICP) mass spectrometry (MS) is routinely used in many diverse research fields such as earth, environmental, life and forensic sciences and in food, material, chemical, semiconductor and nuclear industries. The high ion density and the high temperature in a plasma provide an ideal atomizer and element ionizer for all types of samples and matrices introduced by a variety of specialized devices. Outstanding properties such as high sensitivity (ppt-ppq), relative salt tolerance, compound-independent element response and highest quantitation accuracy lead to the unchallenged performance of ICP MS in efficiently detecting, identifying and reliably quantifying trace elements. The increasing availability of relevant reference compounds and high separation selectivity extend the molecular identification capability of ICP MS hyphenated to species-specific separation techniques. While molecular ion source MS is specialized in determining the structure of unknown molecules, ICP MS is an efficient and highly sensitive tool for target-element orientated discoveries of relevant and unknown compounds. This special-feature, tutorial article presents the principle and advantages of ICP MS, highlighting these using examples from recently published investigations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号