首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We present a new procedure for the determination of 32 volatile organonitrogen compounds in samples of industrial effluents with a complex matrix. The procedure, based on dispersive liquid–liquid microextraction followed by gas chromatography with nitrogen‐phosphorus and mass spectrometric detection, was optimized and validated. Optimization of the extraction included the type of extraction and disperser solvent, disperser solvent volume, pH, salting out effect, extraction, and centrifugation time. The procedure based on nitrogen‐phosphorus detection was found to be superior, having lower limits of detection (0.0067–2.29 μg/mL) and quantitation as well as a wider linear range. The developed procedure was applied to the determination of content of volatile organonitrogen compounds in samples of raw effluents from the production of bitumens in which 13 compounds were identified at concentrations ranging from 0.15 to 10.86 μg/mL and in samples of effluents treated by various chemical methods.  相似文献   

2.
We present a new procedure for the determination of volatile organosulfur compounds in samples of industrial effluents using dispersive liquid–liquid microextraction and gas chromatography with flame photometric detection. Initially, the extraction parameters were optimized. These included: type and volume of extraction solvent, volume of disperser solvent, salting out effect, pH, time and speed of centrifugation as well as extraction time. The procedure was validated for 30 compounds. The developed procedure has low detection limits of 0.0071–0.49 μg/L and a good precision (relative standard deviation values of 1.2–5.0 and 0.6–4.1% at concentrations of 1 and 10 μg/L, respectively). The procedure was used to determine the content of volatile organosulfur compounds in samples of effluents from the production of bitumens before and after chemical treatment, in which six compounds were identified, including 2‐mercaptoethanol, thiophenol, thioanisole, dipropyl disulfide, 1‐decanethiol, and phenyl isothiocyanate at concentrations ranging from 0.47 to 8.89 μg/L. Problems in the determination of organosulfur compounds related to considerable changes in composition of the effluents, increase in concentration of individual compounds and appearance of secondary pollutants during effluent treatment processes are also discussed.  相似文献   

3.
We present a new method for simultaneous determination of 22 monoaromatic and polycyclic aromatic hydrocarbons in postoxidative effluents from the production of petroleum bitumen using dispersive liquid–liquid microextraction coupled to gas chromatography and mass spectrometry. The eight extraction parameters including the type and volume of extraction and disperser solvent, pH, salting out effect, extraction, and centrifugation time were optimized. The low detection limit ranging from 0.36 to 28 μg/L, limit of quantitation (1.1–84 μg/L), good reproducibility, and wide linear ranges, as well as the recoveries ranging from 71.74 to 114.67% revealed that the new method allows the determination of aromatic hydrocarbons at low concentration levels in industrial effluents having a very complex composition. The developed method was applied to the determination of content of mono‐ and polycyclic aromatic hydrocarbons in samples of raw postoxidative effluents in which 15 compounds were identified at concentrations ranging from 1.21 to 1017.0 μg/L as well as in effluents after chemical treatment.  相似文献   

4.
A low‐cost and simple cooling‐assisted headspace liquid‐phase microextraction device for the extraction and determination of 2,6,6‐trimethyl‐1,3 cyclohexadiene‐1‐carboxaldehyde (safranal) in Saffron samples, using volatile organic solvents, was fabricated and evaluated. The main part of the cooling‐assisted headspace liquid‐phase microextraction system was a cooling capsule, with a Teflon microcup to hold the extracting organic solvent, which is able to directly cool down the extraction phase while the sample matrix is simultaneously heated. Different experimental factors such as type of organic extraction solvent, sample temperature, extraction solvent temperature, and extraction time were optimized. The optimal conditions were obtained as: extraction solvent, methanol (10 μL); extraction temperature, 60°C; extraction solvent temperature, 0°C; and extraction time, 20 min. Good linearity of the calibration curve (R2 = 0.995) was obtained in the concentration range of 0.01–50.0 μg/mL. The limit of detection was 0.001 μg/mL. The relative standard deviation for 1.0 μg/mL of safranal was 10.7% (n = 6). The proposed cooling‐assisted headspace liquid‐phase microextraction device was coupled (off‐line) to high‐performance liquid chromatography and used for the determination of safranal in Saffron samples. Reasonable agreement was observed between the results of the cooling‐assisted headspace liquid‐phase microextraction high‐performance liquid chromatography method and those obtained by a validated ultrasound‐assisted solvent extraction procedure.  相似文献   

5.
The pressurized liquid extraction (PLE) followed by dispersive liquid–liquid micro‐extraction (DLLME) has been developed for extraction of volatile components in tobacco. 35 volatile components were detected by gas chromatography mass spectrometry (GC‐MS). Methanol–methyl tert‐butyl ether (MTBE) (8:2, v/v) was selected as PLE extraction solvent. The optimized DLLME procedure, 3 mL of pure water and 1.0 mL tobacco extract solution, 40 μL of chloroform as extraction solvent, 0.5 mL of acetonitrile as disperser solvent, was validated. Under the optimum conditions, the enrichment factors were in the range of 96‐159. The limits of detection were between 0.14 and 0.33 μg/kg. The repeatability of the proposed method, expressed as relative standard deviation, varied between 4.3 and 7.5% (n = 6). The recoveries of the analytes evaluated by fortification of tobacco samples were in the range of 84.7‐96.4%. Compared with the conventional sample preparation method for determination of volatile components in tobacco, the proposed method was quick and easy to operate, and had high‐enrichment factors and low consumption of organic solvent.  相似文献   

6.
A simple technique for the collection of an extraction solvent lighter than water after dispersive liquid–liquid microextraction combined with high‐performance liquid chromatography with ultraviolet detection was developed for the determination of four paraben preservatives in aqueous samples. After the extraction procedure, low‐density organic solvent together with some little aqueous phase was separated by using a disposable glass Pasteur pipette. Next, the flow of the aqueous phase was stopped by successive dipping the capillary tip of the pipette into anhydrous Na2SO4. The upper organic layer was then removed simply with a microsyringe and injected into the high‐performance liquid chromatography system. Experimental parameters that affect the extraction efficiency were investigated and optimized. Under optimal extraction conditions, the extraction recoveries ranged from 25 to 86%. Good linearity with coefficients with the square of correlation coefficients ranging from 0.9984 to 0.9998 was observed in the concentration range of 0.001–0.5 μg/mL. The relative standard deviations ranged from 4.1 to 9.3% (n = 5) for all compounds. The limits of detection ranged from 0.021 to 0.046 ng/mL. The method was successfully applied for the determination of parabens in tap water and fruit juice samples and good recoveries (61–108%) were achieved for spiked samples.  相似文献   

7.
A simple, efficient, solvent‐free, and commercial readily available approach for determination of five volatile chlorinated hydrocarbons in water samples using the static headspace sampling and gas chromatography with electron capture detection has been described. The proposed static headspace sampling method was initially optimized and the optimum experimental conditions found were 10 mL water sample containing 20% w/v sodium chloride placed in a 20 mL vial and stirred at 50ºC for 20 min. The linearity of the method was in the range of 1.2–240 μg/L for dichloromethane, 0.2–40 μg/L for trichloromethane, 0.005–1 μg/L for perchloromethane, 0.025–5 μg/L for trichloroethylene, and 0.01–2 μg/L for perchloroethylene, with coefficients of determination ranging between 0.9979 and 0.9990. The limits of detection were in the low μg/L level, ranging between 0.001 and 0.3 μg/L. The relative recoveries of spiked five volatile chlorinated hydrocarbons with external calibration method at different concentration levels in pure, tap, sea water of Jiaojiang Estuary, and sea water of waters of Xiaomendao were in the range of 91–116, 96–105, 86–112, and 80–111%, respectively, and with relative standard deviations of 1.9–3.6, 2.3–3.5, 1.5–2.7, and 2.3–3.7% (n = 5), respectively. The performance of the proposed method was compared with traditional liquid–liquid extraction on the real water samples (i.e., pure, tap, and sea water, etc.) and comparable efficiencies were obtained. It is concluded that this method can be successfully applied for the determination of volatile chlorinated hydrocarbons in different water samples.  相似文献   

8.
In the present work, a rapid method with little sample handling has been developed for determination of 23 selected volatile organic compounds in environmental and wastewater samples. The method is based on headspace solid-phase microextraction (SPME) followed by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS) determination using triple quadrupole analyzer (QqQ) in electron ionization mode. The best conditions for extraction were optimised with a factorial design taking into account the interaction between different parameters and not only individual effects of variables. In the optimized procedure, 4 mL of water sample were extracted using a 10 mL vial and adding 0.4 g NaCl (final NaCl content of 10%). An SPME extraction with carboxen/polydimethylsiloxane 75 μm fiber for 30 min at 50°C (with 5 min of previous equilibration time) with magnetic stirring was applied. Chromatographic determination was carried out by GC-MS/MS working in Selected Reaction Monitoring (SRM) mode. For most analytes, two MS/MS transitions were acquired, although for a few compounds it was difficult to obtain characteristic abundant fragments. In those cases, a pseudo selected reaction monitoring (pseudo-SRM) with three ions was used instead. The intensity ratio between quantitation (Q) and confirmation (q) signals was used as a confirmatory parameter. The method was validated by means of recovery experiments (n=6) spiking mineral water samples at three concentration levels (0.1, 5 and 50 μg L(-1)). Recoveries between 70% and 120% were generally obtained with relative standard deviations (RSDs) lower than 20%. The developed method was applied to surface water and wastewater from a wastewater treatment plant and from a municipal solid-waste treatment plant. Several compounds, like chloroform, benzene, trichloroethylene, toluene, tetrachloroethylene, dibromochloromethane, xylenes and bromoform were detected and confirmed in all the samples analyzed.  相似文献   

9.
In this study, the preparation and application of extraction bars of PDMS were investigated to preconcentrate and determine benzene, toluene, ethylbenzene, and xylene in water and wastewater by means of HPLC with fluorescence detection. Aliquot samples from hospital wastewater were used as the model effluent. The independent variables for the sorptive extraction were as follows: ionic strength (added amounts of NaCl); pH; temperature and time of absorption; temperature and time of desorption. Under optimized conditions, by using a factorial design, the suspended extraction bars could allow the determination of benzene, toluene, ethylbenzene, and xylene (1.20 ± 0.05 μg/L; 10.40 ± 0.02 μg/L; 1.80 ± 0.04 μg/L; 15.9 ± 0.04 μg/L, respectively) in hospital effluent (fortified samples), by recoveries of 71.9 ± 4.9 to 74.8 ± 5.6%. This procedure represents an innovation that eliminates the time‐consuming stage of vacuum microfiltration, and allows the determination of volatile organic compounds by HPLC. As far as we know, this procedure is original and represents an important contribution to the field.  相似文献   

10.
A rapid liquid phase extraction employing a novel hydrophobic surfactant‐based room temperature ionic liquid (RTIL), tetrabutylphosphonium dioctyl sulfosuccinate ([4C4P][AOT]), coupled with capillary electrophoretic‐UV (CE‐UV) detection is developed for removal and determination of phenolic compounds. The long‐carbon‐chain RTIL used is sparingly soluble in most solvents and can be used to replace volatile organic solvents. This fact, in combination with functional‐surfactant‐anions, is proposed to reduce the interfacial energy of the two immiscible liquid phases, resulting in highly efficient extraction of analytes. Several parameters that influence the extraction efficiencies, such as extraction time, RTIL type, pH value, and ionic strength of aqueous solutions, were investigated. It was found that, under acidic conditions, most of the investigated phenols were extracted from aqueous solution into the RTIL phase within 12 min. Good linearity was observed over the concentration range of 0.1–80.0 μg/mL for all phenols investigated. The precision of this method, expressed as RSD, was determined to be within 3.4–5.3% range. The LODs (S/N = 3) of the method were in the range of 0.047–0.257 μg/mL. The proposed methodology was successfully applied to determination of phenols in real water samples.  相似文献   

11.
Vortex‐assisted liquid–liquid microextraction followed by high‐performance liquid chromatography with UV detection was applied to determine Isocarbophos, Parathion‐methyl, Triazophos, Phoxim and Chlorpyrifos‐methyl in water samples. 1‐Bromobutane was used as the extraction solvent, which has a higher density than water and low toxicity. Centrifugation and disperser solvent were not required in this microextraction procedure. The optimum extraction conditions for 15 mL water sample were: pH of the sample solution, 5; volume of the extraction solvent, 80 μL; vortex time, 2 min; salt addition, 0.5 g. Under the optimum conditions, enrichment factors ranging from 196 to 237 and limits of detection below 0.38 μg/L were obtained for the determination of target pesticides in water. Good linearities (r > 0.9992) were obtained within the range of 1–500 μg/L for all the compounds. The relative standard deviations were in the range of 1.62–2.86% and the recoveries of spiked samples ranged from 89.80 to 104.20%. The whole proposed methodology is simple, rapid, sensitive and environmentally friendly for determining traces of organophosphorus pesticides in the water samples.  相似文献   

12.
A simple, rapid, and sensitive method for the determination of atrazine, simazine, cyproconazole, tebuconazole, and epoxiconazole in mineral water employing the dispersive liquid–liquid microextraction with solidification of a floating organic drop with determination by liquid chromatography tandem mass spectrometry has been developed. A mixed solution of 250 μL 1‐dodecanol and 1250 μL methanol was injected rapidly into 10 mL aqueous solution (pH 7.0) with 2% w/v NaCl. After centrifugation for 5 min at 2000 rpm, the organic solvent droplets floated on the surface of the aqueous solution and the floating solvent solidified. The method limits of detection were between 3.75 and 37.5 ng/L and limits of quantification were between 12.5 and 125 ng/L. The recoveries ranged from 70 to 118% for repeatability and between 76 and 95% for intermediate precision with a relative standard deviation from 2 to 18% for all compounds. Low matrix effect was observed. The proposed method can be successfully applied in routine analysis for determination of pesticide residues in mineral water samples, allowing for monitoring of triazine and triazoles at levels below the regulatory limits set by international and national legislations.  相似文献   

13.
A procedure for multiresidue analysis was developed for the extraction and determination of 17 pesticides, including herbicides, fungicides, and insecticides, as well as certain degradation products, in vineyard soils from La Rioja region (Spain). Different solvents and mixtures were tested in spiked pesticide‐free soils, and pesticides were comparatively evaluated by gas chromatography with mass spectrometry and liquid chromatography with mass spectrometry. Recoveries >70%, with relative standard deviations <9%, were obtained when a mixture of methanol/acetone or a mixture of methanol/CaCl2 0.01 M for the most polar compounds was selected as the extraction solvent. Method validation was accomplished with acceptable linearity (r2 ≥ 0.987) within the concentration range of 0.005–1 μg/mL corresponding to 1.667–333.4 μg/kg and 0.835–167.1 μg/kg for liquid chromatography with mass spectrometry and gas chromatography with mass spectrometry, respectively, and detection limits <0.4 μg/kg for the compounds were studied. The extraction method was applied to 17 real vineyard soil samples, and terbuthylazine and its metabolite desethylterbuthylazine were the most ubiquitous compounds, as they were detected in the 100% of the soils analyzed. The presence of fungicides was also high, and the presence of insecticides was lower than other pesticides. The results confirm the usefulness of the optimized procedure for monitoring residues in vineyard soils.  相似文献   

14.
A convenient procedure for the determination of organomercuric compounds in soils from orchards and wheat fields is described based on the aqueous derivatization of the polar organomercuric halides in 0.1 M HAc-NaAc (pH 4) buffer into their hydrides by addition of 1 mL of 6% KBH4 with subsequent headspace solid phase microextraction (SPME) of the volatile derivatives. The volatile derivatives are separated by gas chromatography (GC) with a Supelco SPB-1 capillary column and on-line detected by electric heated quartz furnace atomic absorption spectrometry (AAS). The relative standard deviations for ten replicate measurements are 2.1%, 2.8% and 3.5% for methyl-, ethyl- and phenylmercury with absolute detection limits of 16 ng, 12 ng and 7 ng, respectively. This method is applied to the analysis of organomercuric compounds in soil samples and 0.04–0.64 μg/g of organomercuric species are detected in soils from different sites. The recoveries after standard addition are between 93–106%.  相似文献   

15.
A novel, stability-indicating gradient reverse-phase ultra-performance liquid chromatographic method was developed for the simultaneous determination of ibuprofen and diphenhydramine citrate in the presence of degradation products and process related impurities in combined dosage form. The method was developed using C18 column with mobile phase containing a gradient mixture of solvent A and B. The eluted compounds were monitored at 220 nm. Ibuprofen and diphenhydramine citrate were subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal, and photolytic degradation. Major unknown impurity formed under oxidative degradation was identified using LC-MS-MS study. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantitation, accuracy, precision and robustness. The described method was linear over the range of 0.20-6.00 μg/mL (r>0.998) for Ibuprofen and 0.084-1.14 μg/mL for diphenhydramine citrate (r>0.998). The limit of detection results were ranged from 0.200-0.320 μg/mL for ibuprofen impurities and 0.084-0.099 μg/mL for diphenhydramine citrate impurities. The limit of quantitation results were ranged from 0.440 to 0.880 μg/mL for ibuprofen impurities and 0.258 to 0.372 μg/mL for diphenhydramine citrate impurities. The recovery of ibuprofen impurities were ranged from 98.1% to 100.5% and the recovery of diphenhydramine citrate impurities were ranged from 97.5% to 102.1%. This method is also suitable for the simultaneous assay determination of ibuprofen and diphenhydramine citrate in pharmaceutical dosage forms.  相似文献   

16.
High‐temperature liquid standard loading strategy onto solid sorbent traps for calibration of thermal desorption–GC–MS techniques for the analysis of volatile organic compounds is evaluated and optimised. With this proposed set‐up, volatilised liquid‐loaded standards interact in gas phase with solid sorbent particles. Response factor for 15 volatile compounds with different vapour pressures have been evaluated and compared with common strategies based on liquid matrix interactions. Using gas matrix strategy improves signal output in the range 10–700%. Average increase for benzene, toluene, ethylbenzene and xylenes is 480%. Reported systematic bias between liquid standards and gas samples are reduced, enhancing thermal desorption methodologies on one of its more important issues. In addition, the proposed system improves the average repeatability to a 3.2%, over 13 times some reported data. The use of an ultra‐thin GC capillary column of 150 μm id performs better peak resolution in about 60% the time with usual 250 μm id capillary columns. The usefulness of this proposed optimised procedure has been proved in real air matrix samples, through a large study with the reliable characterisation of 93 different volatile compounds in the ambient air of a municipal solid waste treatment area  相似文献   

17.
A high-performance liquid chromatography with ultraviolet detection (HPLC-UV) is established for the simultaneous determination of p-phthalic acid, benzoic acid, 4-carboxybenzaldehyde, m-phthalic acid, o-phthalic acid, phthalide, o-toluic acid, m-toluic acid and p-toluic acid in the residue generated during the production of p-phthalic acid (PPA). On a narrow-diameter reversed-phase C18 column, gradient elution is applied with a methanol-water-ammonium acetate-acetic acid buffer (100 mmol/L, pH 4.70) as mobile phase at a flow rate of 0.2 mL/min, and detection is operated by UV absorption at a wavelength of 254 nm. Under the conditions, these nine relative compounds, including organic acids, are well separated. The detection limits (S/N = 3) are 0.05 μg/mL-0.20 μg/mL, and the correlation coefficients of standard curves are between 0.99995 and 0.99999. Relative standard deviations for analyses of real samples are below 5.3%, and recoveries of these determined compounds ranges from 90.0 to 104.9%. The method, which provides accurate and reliable results, can effectively guide the recycling and reutilization of organic acids and related substances in PPA residue.  相似文献   

18.
A simple, rapid and inexpensive procedure for extraction and analysis of volatile halocarbons in water samples was presented using the headspace single-drop microextraction (HS-SDME) technique and gas chromatography with microcell electron capture detector (GC-μECD). Operation parameters. such as extraction solvent. headspace volume. organic drop volume. salt concentration. temperature and sampling time, were studied and optimized. Extraction of 10 volatile halocarbon compounds was achieved using the optimized method. Calibration curves of 10 target compounds yielded good linearity in the respective range of concentration (R 2 ≥ 0.9968, chlorodibromomethane in the concentration range of 0.05–50 μg/L). The limits of detection were found between 0.002 (tetrachloroethene) and 0.374μg/L (1,1,2-trichloroethane). and relative standard deviations (RSD%) ranged between 4.3 (chloroform) and 9.7% (1,1,2,2-tetrachloroethane). Spiked recoveries of tap water and ground water agreed well with the known values between 118.97 (20.0μg/L of 1,1,2-trichloroethane) and 82.61% (10.0μg/L of tetrachloroethene), demonstrating that the HS-SDME combined GC-μECD was a useful and reliable technique for the rapid determination of volatile halocarbon compounds in water samples.  相似文献   

19.
The volatile components of Cnidium monnieri were obtained by supercritical fluid extraction (SFE) and analyzed by GC‐MS (identification and determination of metabolites). The compounds were identified according to their retention times and mass spectra. The effects of different parameters, such as extraction pressure, temperature, dynamic extraction time, flow rate of CO2, on the SFE of C. monnieri extracts were investigated. A total of 14 compounds of SFE extracts were identified. Osthole (69.52%), bornyl acetate (10.03%), α‐pinene (4.71%), and imperatorin (2.42%) were the major compounds identified in C. monnieri SFE extracts. The quantitation of osthole and imperatorin were then accomplished. The linear calibration ranges were all 5–1000 μg/mL for osthole and imperatorin by GC‐MS analysis. The recovery of osthole and imperatorin were in the range 96.5–101.8%. The LODs for osthole and imperatorin were 1.0 and 0.6 μg/mL, respectively.  相似文献   

20.
SPE combined with dispersive liquid–liquid microextration was used for the extraction of ultra‐trace amounts of benzodiazepines (BZPs) including, diazepam, midazolam, and alprazolam, from ultra‐pure water, tap water, fruit juices, and urine samples. The analytes were adsorbed from large volume samples (60 mL) onto octadecyl silica SPE columns. After the elution of the desired compounds from sorbents with 2.0 mL acetone, 0.5 mL of eluent containing 40.0 μL chloroform was injected rapidly into 4.5 mL pure water. After extraction and centrifugation, 2 μL of the sedimented phase was injected into a GC equipped with a flame ionization detector. Several parameters affecting this process were investigated and optimized. Under the optimal conditions, LODs ranged from 0.02 to 0.05 μg/L, a linear dynamic range of 0.1–100 μg/L and relative SDs in the range of 4.4–10.7% were attained. Very high preconcentration factors ranging from 3895–7222 were achieved. The applicability of the method for the extraction of BZPs from different types of complicated matrices, such as tap water, fruit juices, and urine samples, was studied. The obtained results reveal that the proposed method is a good technique for the extraction and determination of BZPs in complex matrices.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号