共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Zhanqi Gao Tingfeng Liu Xiaoju Yan Cheng Sun Huan He Shaogui Yang 《Journal of separation science》2013,36(6):1112-1118
A simple, environment friendly and efficient technique, ionic liquid‐based microwave‐assisted extraction was first used to determine malachite green and crystal violet (CV) from water samples coupled to HPLC. The key parameters influencing extraction efficiency were investigated, such as the type of ionic liquids, the volume of ionic liquid, extraction time, and so on. Under the optimum conditions, good reproducibility of the extraction performance was obtained (RSD, 1.0% for malachite green (MG) and 5.9% for CV, n = 5). Good linearity (0.10–25 μg L?1) was observed with correlation coefficients between 0.9991 and 0.9964. The detection limits of MG and CV were 0.080 and 0.030 μg L?1, respectively. The proposed method had been successfully applied to determine MG and CV in real water samples with recoveries ranging from 95.4 to 102.8%. Compared with the previous technologies, the proposed method required less extraction time (2 min), and provided lower detection limits and higher enrichment factors. Moreover, there were no volatile and hazardous organic solvents released. Based on these simple, environment friendly, rapid, and highly efficient results, the proposed approach provides a new and promising alternative for simultaneously extracting trace amounts of MG and CV from water. 相似文献
3.
Chaoyang Long Zhibin Mai Yingfen Yang Binghui Zhu Xiumin Xu Lin Lu Xiaoyong Zou 《Journal of chromatography. A》2009,1216(12):2275-2281
A sorbent was synthesized and investigated for molecularly imprinted solid-phase extraction (MISPE). Molecularly imprinted polymers (MIPs) were synthesized via precipitation polymerization procedure, where methacrylic acid (MAA) was used as functional monomer and ethylene glycol dimethacrylate (EDMA) as cross-linking agent. The imprinting effect and selectivity of the MISPE were evaluated by elution experiments. The resulting MISPE showed high extraction selectivity to malachite green, gentian violet and their metabolites, which may be caused by both the ion exchange and the hydrophobic interactions. The determination of multi-residue for malachite green, gentian violet and their metabolites in aquatic products by HPLC coupled with MISPE was also investigated. The mean recoveries calculated by solvent calibration curve for malachite green (MG), gentian violet (GV), leucomalachite green (LMG) and leucogentian violet (LGV) were from 89.8% to 99.1% for grass carp, 90.6% to 101.2% for shrimp and 91.3% to 96.3% for shellfish. The decision limit (CCα) and the detection capability (CCβ) obtained for MG, GV, LMG and LGV were in the range of 0.11–0.14 and 0.19–0.24 μg kg−1 for grass carp, shrimp and shellfish. The MISPE was successfully used off-line for the determination of MG, GV and their metabolites in aquatic products. 相似文献
4.
Magnetic mixed hemimicelles solid‐phase extraction coupled with high‐performance liquid chromatography for the extraction and rapid determination of six fluoroquinolones in environmental water samples 下载免费PDF全文
In this study, a mixed hemimicelle solid‐phase extraction method based on Fe3O4 nanoparticles coated with sodium dodecyl sulfate was applied for the preconcentration and fast isolation of six fluoroquinolones in environmental water samples before high‐performance liquid chromatography determination. The main factors affecting the extraction efficiency of the analytes, such as amount of surfactant, amount of Fe3O4 nanoparticles, extraction time, sample volume, sample pH, ionic strength, and desorption conditions, were investigated and optimized. The method has detection limits from 0.05 to 0.1 ng/mL and good linearity (r ≥ 09948) in the range 0.1–200 ng/mL depending on the fluoroquinolone. The enrichment factor is ~200. The recoveries (at spiked levels of 1, 5, and 50 ng/mL) are in the range of 79–120%. 相似文献
5.
Simultaneous determination of four trace estrogens in feces,leachate, tap and groundwater using solid–liquid extraction/auto solid‐phase extraction and high‐performance liquid chromatography with fluorescence detection 下载免费PDF全文
Na Liu Yue‐e Shi Mengyan Li Ting‐di Zhang Song Gao 《Journal of separation science》2015,38(20):3494-3501
A simple and selective high‐performance liquid chromatography method coupled with fluorescence detection was developed for the simultaneous measurement of trace levels of four estrogens (estrone, estradiol, estriol and 17α‐ethynyl estradiol) in environmental matrices. For feces samples, solid–liquid extraction was applied with a 1:1 v/v mixture of acetonitrile and ethyl acetate as the extraction solvent. For liquid samples (e.g., leachate and groundwater), hydrophobic/lipophilic balanced automated solid‐phase extraction disks were selected due to their high recoveries compared to conventional C18 disks. Chromatographic separations were performed on a reversed‐phase C18 column gradient‐eluted with a 45:55 v/v mixture of acetonitrile and water. The detection limits were down to 1.1 × 10?2 (estrone), 4.11 × 10?4 (estradiol), 5.2 × 10?3 (estriol) and 7.18 × 10?3 μg/L (17α‐ethynyl estradiol) at excitation/emission wavelengths of 288/310 nm, with recoveries in the range of 96.9 ± 3.2–105.4 ± 3.2% (n = 3). The method was successfully applied to determine estrogens in feces and water samples collected at livestock farms and a major river in Northeast China. We observed relatively high abundance and widespread distribution of all four estrogens in our sample collections, implying the urgency for a comprehensive and intricate investigation of estrogenic fate and contamination in our researched area. 相似文献
6.
Ultrapreconcentration and determination of organophosphorus pesticides in water by solid‐phase extraction combined with dispersive liquid–liquid microextraction and high‐performance liquid chromatography 下载免费PDF全文
Junhua Chen Guangming Zhou Yongli Deng Hongmei Cheng Jie Shen Yi Gao Guilong Peng 《Journal of separation science》2016,39(2):272-278
Solid‐phase extraction coupled with dispersive liquid–liquid microextraction was developed as an ultra‐preconcentration method for the determination of four organophosphorus pesticides (isocarbophos, parathion‐methyl, triazophos and fenitrothion) in water samples. The analytes considered in this study were rapidly extracted and concentrated from large volumes of aqueous solutions (100 mL) by solid‐phase extraction coupled with dispersive liquid–liquid microextraction and then analyzed using high performance liquid chromatography. Experimental variables including type and volume of elution solvent, volume and flow rate of sample solution, salt concentration, type and volume of extraction solvent and sample solution pH were investigated for the solid‐phase extraction coupled with dispersive liquid–liquid microextraction with these analytes, and the best results were obtained using methanol as eluent and ethylene chloride as extraction solvent. Under the optimal conditions, an exhaustive extraction for four analytes (recoveries >86.9%) and high enrichment factors were attained. The limits of detection were between 0.021 and 0.15 μg/L. The relative standard deviations for 0.5 μg/L of the pesticides in water were in the range of 1.9–6.8% (n = 5). The proposed strategy offered the advantages of simple operation, high enrichment factor and sensitivity and was successfully applied to the determination of four organophosphorus pesticides in water samples. 相似文献
7.
Mycoestrogen determination in cow milk: Magnetic solid‐phase extraction followed by liquid chromatography and tandem mass spectrometry analysis 下载免费PDF全文
Anna Laura Capriotti Chiara Cavaliere Patrizia Foglia Giorgia La Barbera Roberto Samperi Salvatore Ventura Aldo Laganà 《Journal of separation science》2016,39(24):4794-4804
Recently, magnetic solid‐phase extraction has gained interest because it presents various operational advantages over classical solid‐phase extraction. Furthermore, magnetic nanoparticles are easy to prepare, and various materials can be used in their synthesis. In the literature, there are only few studies on the determination of mycoestrogens in milk, although their carryover in milk has occurred. In this work, we wanted to develop the first (to the best of our knowledge) magnetic solid‐phase extraction protocol for six mycoestrogens from milk, followed by liquid chromatography and tandem mass spectrometry analysis. Magnetic graphitized carbon black was chosen as the adsorbent, as this carbonaceous material, which is very different from the most diffuse graphene and carbon nanotubes, had already shown selectivity towards estrogenic compounds in milk. The graphitized carbon black was decorated with Fe3O4, which was confirmed by the characterization analyses. A milk deproteinization step was avoided, using only a suitable dilution in phosphate buffer as sample pretreatment. The overall process efficiency ranged between 52 and 102%, whereas the matrix effect considered as signal suppression was below 33% for all the analytes even at the lowest spiking level. The obtained method limits of quantification were below those of other published methods that employ classical solid‐phase extraction protocols. 相似文献
8.
Magnetic molecularly imprinted composite for the selective solid‐phase extraction of p‐aminosalicylic acid followed by high‐performance liquid chromatography with ultraviolet detection 下载免费PDF全文
Hasan Bagheri Karam Molaei Ali Akbar Asgharinezhad Homeira Ebrahimzadeh Mojtaba Shamsipur 《Journal of separation science》2016,39(21):4166-4174
A new method for the selective extraction of p‐aminosalicylic acid from aqueous and urine samples has been developed using magnetic molecularly imprinted polymer nanoparticles before determination by high‐performance liquid chromatography. The Fe3O4 nanoparticles were first prepared through the chemical coprecipitation of Fe2+ and Fe3+ and then coated with a vinyl shell. Subsequently, a layer of molecularly imprinted polymers was grafted onto the vinyl‐modified magnetic nanoparticles by precipitation polymerization. FTIR spectroscopy, scanning electron microscopy, vibrating sample magnetometry, and thermogravimetric analysis were applied to characterize the sorbent properties. Moreover, the predominant parameters affecting the magnetic solid phase extraction such as sample pH, sorption and elution times, the amount of sorbent, and composition and volume of eluent were investigated thoroughly. The maximum sorption capacity of the imprinted polymer toward p‐aminosalicylic acid was 70.9 mg/g, which is 4.5 times higher than that of the magnetic nonimprinted polymer. The magnetic molecularly imprinted polymer nanoparticles were applied for the selective extraction of p‐aminosalicylic acid from aqueous and urine samples and satisfactory results were achieved. The results illustrate that magnetic molecularly imprinted polymer nanoparticles have a great potential in the extraction of p‐aminosalicylic acid from environmental and biological matrices. 相似文献
9.
A novel and sensitive extraction procedure using maghemite nanoparticles (γ-Fe2O3) modified with sodium dodecyl sulfate (SDS), as an efficient solid phase, was developed for removal, preconcentration and spectrophotometric determination of trace amounts of malachite green (MG) and leuco-malachite green (LMG). Combination of nanoparticle adsorption and easily magnetic separation was used to extraction and desorption of MG and LMG. The adsorption capacity was evaluated using both the Langmuir and Freundlich adsorption isotherm models. Maghemite nanoparticles were prepared by co-precipitation method and their surfaces were modified by SDS. The size and properties of the produced maghemite nanoparticles was determined by X-ray diffraction (XRD) analysis, scanning electron microscopy (SEM) and BET analysis. MG and LMG became adsorbed at pH 3.0. LMG was oxidized to MG by adsorption on maghemite nanoparticles. The adsorbed MG was then desorbed and determined spectrophotometrically. The calibration graph was linear in the range 0.50-250.00 ng mL−1 of MG and LMG with a correlation coefficient of 0.9991. The detection limit of the method for determination of MG was 0.28 ng mL−1 and the relative standard deviation (R.S.D.) for 10.00 and 50.00 ng mL−1 of malachite green was 1.60% (n = 3) and 0.86% (n = 5), respectively. A preconcentration factor of 50 was achieved in this method. The Langmuir adsorption capacity (qmax) was found to be 227.3 mg g−1 of the adsorbent. The method was applied to the determination of MG in fish farming water samples. 相似文献
10.
Magnetic solid‐phase extraction for determination of sulpiride in human urine and blood using high‐performance liquid chromatography 下载免费PDF全文
A novel and efficient sample preconcentration technique based on the Fe3O4 magnetic nanoparticles (Fe3O4 MNPs) coated with silica (SiO2) has been developed for extraction and determination of sulpiride. The functionalized MNPs showed excellent dispersibility in aqueous solution and were applied to magnetic solid‐phase extraction of sulpiride from human urine and blood prior to high‐performance liquid chromatography analysis. The separation, preconcentration and desorption procedure was completed in 10 min. Optimal experimental conditions, including sample pH, the amount of the MNPs, eluent type and volume, and the ultrasonication time were studied and established. The method showed good linearity for the determination of sulpiride in the concentration range of 10–1000 ng/mL in urine and blood. The recovery of the method was in the range between 91.2 and 97.5%, and the limit of detection was 2 ng/mL for sulpiride in human blood and urine. The results indicated that the present procedure is a suitable pretreatment method for biological samples. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
11.
Ionic‐liquid‐based dispersive liquid–liquid microextraction combined with magnetic solid‐phase extraction for the determination of aflatoxins B1, B2, G1, and G2 in animal feeds by high‐performance liquid chromatography with fluorescence detection 下载免费PDF全文
Jiao Zhao Yan Zhu Yang Jiao Jinyan Ning Yaling Yang 《Journal of separation science》2016,39(19):3789-3797
A novel two‐step extraction technique combining ionic‐liquid‐based dispersive liquid–liquid microextraction with magnetic solid‐phase extraction was developed for the preconcentration and separation of aflatoxins in animal feedstuffs before high‐performance liquid chromatography coupled with fluorescence detection. In this work, ionic liquid 1‐octyl‐3‐methylimidazolium hexafluorophosphate was used as the extractant in dispersive liquid–liquid microextraction, and hydrophobic pelargonic acid modified Fe3O4 magnetic nanoparticles as an efficient adsorbent were applied to retrieve the aflatoxins‐containing ionic liquid. Notably, the target of magnetic nanoparticles was the ionic liquid rather than the aflatoxins. Because of the rapid mass transfer associated with the dispersive liquid–liquid microextraction and magnetic solid phase steps, fast extraction could be achieved. The main parameters affecting the extraction recoveries of aflatoxins were investigated and optimized. Under the optimum conditions, vortexing at 2500 rpm for 1 min in the dispersive liquid–liquid microextraction and magnetic solid‐phase extraction and then desorption by sonication for 2 min with acetonitrile as eluent. The recoveries were 90.3–103.7% with relative standard deviations of 3.2–6.4%. Good linearity was observed with correlation coefficients ranged from 0.9986 to 0.9995. The detection limits were 0.632, 0.087, 0.422 and 0.146 ng/mL for aflatoxins B1, B2, G1, and G2, respectively. The results were also compared with the pretreatment method carried out by conventional immunoaffinity columns. 相似文献
12.
Development of a magnetic solid‐phase extraction coupled with high‐performance liquid chromatography method for the analysis of polyaromatic hydrocarbons 下载免费PDF全文
Yan Ma Jiawen Xie Jing Jin Wei Wang Zhijian Yao Qing Zhou Aimin Li Ying Liang 《Journal of separation science》2015,38(14):2517-2525
A novel magnetic solid phase extraction coupled with high‐performance liquid chromatography method was established to analyze polyaromatic hydrocarbons in environmental water samples. The extraction conditions, including the amount of extraction agent, extraction time, pH and the surface structure of the magnetic extraction agent, were optimized. The results showed that the amount of extraction agent and extraction time significantly influenced the extraction performance. The increase in the specific surface area, the enlargement of pore size, and the reduction of particle size could enhance the extraction performance of the magnetic microsphere. The optimized magnetic extraction agent possessed a high surface area of 1311 m2/g, a large pore size of 6–9 nm, and a small particle size of 6–9 μm. The limit of detection for phenanthrene and benzo[g,h,i]perylene in the developed analysis method was 3.2 and 10.5 ng/L, respectively. When applied to river water samples, the spiked recovery of phenanthrene and benzo[g,h,i]perylene ranged from 89.5–98.6% and 82.9–89.1%, respectively. Phenanthrene was detected over a concentration range of 89–117 ng/L in three water samples withdrawn from the midstream of the Huai River, and benzo[g,h,i]perylene was below the detection limit. 相似文献
13.
Development and validation of a magnetic solid‐phase extraction with high‐performance liquid chromatography method for the simultaneous determination of amphetamine and methadone in urine 下载免费PDF全文
Arezou Taghvimi Hamed Hamishehkar Mahmoud Ebrahimi 《Journal of separation science》2016,39(12):2307-2312
The simultaneous determination of amphetamine and methadone was carried out by magnetic graphene oxide nanoparticles, a magnetic solid‐phase extraction adsorbent, as a new sample treatment technique. The main factors (the amounts of sample volume, amount of adsorbent, type and amount of extraction organic solvent, time of extraction and desorption, pH, the ionic strength of extraction medium, and agitation rate) influencing the extraction efficiency were investigated and optimized. Under the optimized conditions, good linearity was observed in the range of 100–1500 ng/mL for amphetamine and 100–1000 ng/mL for methadone. The method was evaluated for determination of AM and methadone in positive urine samples, satisfactory results were obtained, therefore magnetic solid‐phase extraction can be applied as a novel method for the determination of drugs of abuse in forensic laboratories. 相似文献
14.
New strategy for the biosorption of atrazine after magnetic solid‐phase extraction from water followed by high‐performance liquid chromatography analysis 下载免费PDF全文
We describe a rapid and simple microextraction of atrazine from water samples. This method is based on the use of magnetic nanoparticles as sorbents and bioaggregates that are applied to the extraction and preconcentration of atrazine. The resulting magnetic nanoparticles possess a fast adsorption kinetics and high adsorption capacity. Bioaggregates made up of rhaminolipid biosurfactant were assessed as a new strategy for the sample treatment. The extractant was obtained from magnetic nanoparticles using the magnetic solid‐phase extraction method. Then the target analyte was rapidly transferred from the sorbent surface to bioaggregates, which have a low toxicity and are green and ecofriendly. Finally, the extract is centrifuged and transferred to micro‐syringe for analysis by high‐performance liquid chromatography. Experimental parameters affecting the extraction efficiency were studied and optimized. Under optimum conditions the enrichment factor was 268. The linear dynamic range and limit of detection were 0.1–50 and 0.033 μg/L, respectively. The relative standard deviation for six replicate measurements was 5.3%. The results demonstrate good applicability of biosorption‐assisted magnetic solid‐phase extraction method for the determination of atrazine from water samples. 相似文献
15.
B. Louveau C. Fernandez N. Zahr H. Sauvageon‐Martre P. Maslanka P. Faure S. Mourah L. Goldwirt 《Biomedical chromatography : BMC》2016,30(12):2009-2015
A precise and accurate high‐performance liquid chromatography (HPLC) quantification method of rifampicin in human plasma was developed and validated using ultraviolet detection after an automatized solid‐phase extraction. The method was validated with respect to selectivity, extraction recovery, linearity, intra‐ and inter‐day precision, accuracy, lower limit of quantification and stability. Chromatographic separation was performed on a Chromolith RP8 column using a mixture of 0.05 m acetate buffer pH 5.7–acetonitrile (35:65, v/v) as mobile phase. The compounds were detected at a wavelength of 335 nm with a lower limit of quantification of 0.05 mg/L in human plasma. Retention times for rifampicin and 6,7‐dimethyl‐2,3‐di(2‐pyridyl) quinoxaline used as internal standard were respectively 3.77 and 4.81 min. This robust and exact method was successfully applied in routine for therapeutic drug monitoring in patients treated with rifampicin. 相似文献
16.
《Journal of separation science》2018,41(9):2020-2028
A green biocomposite of sunflower stalks and graphitic carbon nitride nanosheets has been applied as a solid‐phase extraction adsorbent for sample preparation of five polycyclic aromatic hydrocarbons in different solutions using high‐performance liquid chromatography with ultraviolet detection. Before the modification, sunflower stalks exhibited relatively low adsorption to the polycyclic aromatic hydrocarbons extraction. The modified sunflower stalks showed increased adsorption to the analytes extraction due to the increase in surface and existence of a π–π interaction between the analytes and graphitic carbon nitride nanosheets on the surface. Under the optimal conditions, the limits of detection and quantification for five polycyclic aromatic hydrocarbons compounds could reach 0.4–32 and 1.2–95 ng/L, respectively. The method accuracy was evaluated using recovery measurements in spiked real samples and good recoveries from 71 to 115% with relative standard deviations of <10% have been achieved. The developed method was successfully applied for polycyclic aromatic hydrocarbons determination in various samples—well water, tap water, soil, vegetable, and barbequed meat (kebab)—with analytes contents ranging from 0.065 to 13.3 μg/L. The prepared green composite as a new sorbent has some advantages including ease of preparation, low cost, and good reusability. 相似文献
17.
Jose María Moreno Aneta Wojnicz Juan Luis Steegman Maria F. Cano‐Abad Ana Ruiz‐Nuño 《Biomedical chromatography : BMC》2013,27(4):502-508
We have developed a method of liquid chromatography in tandem with mass spectrometry to monitor therapeutic levels of imatinib in plasma, a selective inhibitor of protein tyrosine kinase. After solid‐phase extraction of plasma samples, imatinib and its internal standard, imatinib‐D8, were eluted with Zorbax SB‐C18 at 60 °C, under isocratic conditions through a mobile phase consisting of 4 mm ammonium formate, pH: 3.2 (solution A) and acetonitrile solution B. The flow rate was 0.8 mL/min with 55% solution A + 45% solution B. Imatinib was detected and quantified by mass spectrometry with electrospray ionization operating in selected‐reaction monitoring mode. The calibration curve was linear in the range 10–5000 ng/mL, the lower limit of quantitation being 10 ng/mL. The method was validated according to the recommendations of the Food and Drug Administration, including tests of matrix effect (bias < 10%) and recovery efficiency (>80 and <120%). The method is precise (coefficient of variance intra‐day <2% and inter‐day <7%), accurate (95–108%), sensitive and specific. It is a simple method with very fast recording time (1.2 min) that is applicable to clinical practice. This will permit improvement of the pharmacological treatment of patients. Copyright © 2012 John Wiley & Sons, Ltd. 相似文献
18.
Xubiao Luo Xin Jiang Xinman Tu Shenglian Luo Liushui Yan Bo Chen 《Electrophoresis》2010,31(4):688-694
We have employed a high‐sensitivity off‐line coupled with on‐line preconcentration method, cloud‐point extraction (CPE)/cation‐selective exhaustive injection (CSEI) and sweeping‐MEKC, for the analysis of malachite green. The variables that affect CPE were investigated. The optimal conditions were 250 g/L of Triton X‐100, 10% of Na2SO4 (w/v), heat‐assisted at 60°C for 20 min. We monitored the effects of several of the CSEI‐sweeping‐MEKC parameters – including the type of BGE, the concentrations of SDS, the injection length of the high‐conductivity buffer, and the injection time of the sample – to optimize the separation process. The optimal BGE was 50 mM citric acid (pH 2.2) containing 100 mM SDS. In addition, electrokinetic injection of the sample at 15 kV for 800 s provided both high separation efficiency and enhanced sweeping sensitivity. The sensitivity enhancement for malachite green was 1.9×104 relative to CZE; the coefficients of determination exceeded 0.9928. The LOD, based on an S/N of 3:1, of CSEI‐sweeping‐MEKC was 0.87 ng/mL; in contrast, when using off‐line CPE/CSEI‐sweeping‐MEKC the sensitivity increased to 69.6 pg/mL. This proposed method was successfully applied to determine trace amounts of malachite green in fish water samples. 相似文献
19.
Rapid determination of nitrite in foods in acidic conditions by high‐performance liquid chromatography with fluorescence detection 下载免费PDF全文
Xiao‐fang Wang Ji‐cai Fan Ren Ren Quan Jin Jing Wang 《Journal of separation science》2016,39(12):2263-2269
In this study, a simple, rapid, and sensitive method for the determination of nitrite (NO2?) in food samples by high‐performance liquid chromatography with fluorescence detection in acidic conditions had been developed. The derivatization of the nitrite with 2,3‐diaminonaphthalene was performed in acidic conditions to yield the highly fluorescent 2,3‐naphthotriazole, which was directly analyzed by high‐performance liquid chromatography with fluorescence detection without adjusting the solution to alkaline. The analysis column was reversed‐phase C8 column. A constant flow rate of 1.0 mL/min was employed using water/acetonitrile as the mobile phase in isocratic mode (70:30, v/v). Fluorescence was monitored with excitation at 375 nm and emission at 415 nm. The standard calibration curves were linear for nitrite in different matrixes in the concentration range of 0–100 μg/L, and the correlation coefficients ranged from 0.9978 to 0.9998. The limits of detection and quantification were in the ranges of 0.012–0.060 and 0.040–0.20 mg/kg, respectively. The recoveries of nitrite from samples spiked at three different concentrations were 74.0–113.2%, and the relative standard deviations of the recovery results (n = 6) were 1.67–10.8%. The proposed method has good repeatability and is very sensitive and simple. It has been successfully used to determine nitrite in foods. 相似文献
20.
《Journal of separation science》2018,41(10):2151-2160
In recent years, the use of human saliva for diagnostic purposes has evoked great interest. Thus, the aim of this study was to choose the optimal solid‐phase extraction cartridges and extraction solvents for the quantitation of venlafaxine in saliva. Blank saliva samples spiked with venlafaxine concentrations between 25 and 750 ng/mL were analyzed using five solid‐phase extraction columns (C18, C8, Strata‐X, Strata‐X‐C, and Strata‐X‐AW), washing solvents (deionized water, phosphate buffer at pH 5.5, and their mixtures with methanol), and elution solvents (methanol, acetonitrile, and their mixtures with 25% ammonia). A high‐performance liquid chromatography system was used to quantify venlafaxine in saliva. The results of this study revealed that nine of 25 procedures enabled quantitation of venlafaxine in the tested concentration range. The procedure that used a C18 cartridge, a mixture of methanol and deionized water as the washing solvent, and methanol as the elution solvent was the most effective and allowed quantitation of all venlafaxine concentrations with an acceptable recovery. In contrast, the Strata‐X‐C cartridge could not detect venlafaxine at the lowest concentration (25 ng/mL). The data acquired from the high‐performance liquid chromatography system were confirmed by a multivariate data analysis. 相似文献