首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed and validated for simultaneous quantification of risperidone (RSP) and its active metabolite 9-hydroxyrisperidone (9-OH-RSP) in human plasma. The analytes were extracted from human plasma by using the protein precipitation extraction technique. Methyl risperidone was used as internal standard for RSP and 9-OH-RSP. A Betasil C18 column provided chromatographic separation of analytes followed by detection with mass spectrometry. The mass transition ion-pair was followed as m/z 411.28 --> 191.15 for RSP and m/z 427.30 --> 207.10 for 9-OH-RSP. The method involves a simple extraction, isocratic chromatography conditions and mass spectrometric detection that enable detection at sub-nanogram levels. The proposed method has been validated with a linear range of 0.10-15.0 ng/mL for RSP and 9-OH-RSP. The intrarun and interrun precision and accuracy values were within 15%. The overall recoveries for RSP and 9-OH-RSP were 82.1% and 83.2%, respectively. The total analysis time was as low as 3.0 min only. The developed method was applied for the determination of the pharmacokinetic parameters of RSP and 9-OH-RSP following a single oral administration of a 1 mg RSP tablet in 24 healthy male volunteers.  相似文献   

2.
An automated, sensitive and high-throughput liquid chromatographic/electrospray tandem mass spectrometric (LC–MS/MS) assay was developed for the simultaneous determination of losartan (LOS), its major circulating metabolite EXP-3174 and hydrochlorothiazide (HCTZ) in human plasma. LOS and HCTZ coexist in the same drug formulation, and this is the first method that enables the simultaneous determination of both drugs along with the active metabolite of LOS. Since these drugs have different physicochemical properties, the employment of a liquid–liquid extraction (LLE) protocol was precluded. A fully automated solid-phase extraction (SPE) protocol, based on 96-well format plates, was used to isolate these compounds and furosemide (internal standard, IS) from plasma. Washing and elution steps were amended accordingly in order to minimize any matrix effect from components of the plasma without reducing the elution of the molecules of interest. The compounds were eluted from a C18 column and detected with an API 3000 triple-quadrupole mass spectrometer using negative electrospray ionization and multiple reaction monitoring (MRM). The assay was linear over the range 1.00–400 ng/mL for LOS and EXP-3174 and 0.500–200 ng/mL for HCTZ, respectively, when 200 μl of plasma was used in the extraction. The overall intra- and interassay variations were within acceptance limits. The analysis time for each sample was 4 min, and more than 300 samples could be analyzed in one day by running the system overnight. The assay was simple, highly sensitive, selective, precise, fast, and it enables the reliable determination of LOS, EXP-3174 and HCTZ in pharmacokinetic or bioequivalence studies after per os administration of a single tablet containing both drugs.  相似文献   

3.
A simple, sensitive and rapid high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry (MS/MS) method was developed and validated for the assay of tizanidine in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by MS/MS in the selected reaction monitoring mode. The assay exhibited a linear dynamic range of 50-5000 pg/mL for tizanidine in human plasma. The lower limit of quantification was 50 pg/mL with a relative standard deviation of less than 13%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.5 min for each sample made it possible to analyze more than 300 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

4.
A rapid, sensitive and robust assay procedure using liquid chromatography coupled with tandem mass spectrometry (LC/MS/MS) for the determination of famotidine in human plasma and urine is described. Famotidine and the internal standard were isolated from plasma samples by cation-exchange solid-phase extraction with benzenesulfonic acid (SCX) cartridges. The urine assay used direct injection of a diluted urine sample. The chromatographic separation was accomplished by using a BDS Hypersil silica column with a mobile phase of acetonitrile-water containing trifluoroacetic acid. The MS/MS detection of the analytes was set in the positive ionization mode using electrospray ionization for sample introduction. The analyte and internal standard precursor-product ion combinations were monitored in the multiple-reaction monitoring mode. Assay calibration curves were linear in the concentration range 0.5--500 ng ml(-1) and 0.05--50 microg ml(-1) in plasma and urine, respectively. For the plasma assay, a 100 microl sample aliquot was subjected to extraction. To perform the urine assay, a 50 microl sample aliquot was used. The intra-day relative standard deviations at all concentration levels were <10%. The inter-day consistency was assessed by running quality control samples during each daily run. The limit of quantification was 0.5 ng ml(-1) in plasma and 0.05 microg ml(-1) in urine. The methods were utilized to support clinical pharmacokinetic studies in infants aged 0-12 months.  相似文献   

5.
A method was developed and fully validated for the quantitation of prazepam and its major metabolites, oxazepam and nordiazepam, in human plasma. Sample pretreatment was achieved by solid-phase extraction using Oasis HLB cartridges. The extracts were analysed by high-performance liquid chromatography (HPLC) coupled with single-quadrupole mass spectrometry (MS) with an electrospray ionization interface. The MS system was operated in the selected ion monitoring mode. HPLC was performed isocratically on a reversed-phase XTerra MS C18 analytical column (150 x 3.0 mm i.d., particle size 5 microm). Diazepam was used as the internal standard for quantitation. The assay was linear over a concentration range of 5.0-1000 ng ml(-1) for all compounds analyzed. The limit of quantitation was 5 ng ml(-1) for all compounds. Quality control samples (5, 10, 300 and 1000 ng ml(-1)) in five replicates from three different runs of analysis demonstrated an intra-assay precision (CV) of < or = 9.1%, an inter-assay precision of < or = 6.0% and an overall accuracy (relative error) of < 4.6%. The method can be used to quantify prazepam and its metabolites in human plasma covering a variety of pharmacokinetic or bioequivalence studies.  相似文献   

6.
Artemisinin is a widely used antimalarial drug. To evaluate the pharmacokinetics of artemisinin in rats, a sensitive and specific liquid chromatography/tandem mass spectrometric (LC/MS/MS) method was developed and validated for the determination of artemisinin in rat plasma. For detection, a Sciex API 4000 LC/MS/MS instrument with an electrospray ionization (ESI) TurboIonSpray inlet in the positive ion multiple reaction monitoring (MRM) mode was used to monitor precursor ([M+NH4]+) --> product ions of m/z 300.4 --> 209.4 for artemisinin and m/z 316.4 --> 163.4 for artemether, the internal standard (IS). The plasma samples were pretreated by a simple liquid-liquid extraction with ether. The standard curve was linear (r > 0.99) over the artemisinin concentration range of 1.0-200.0 ng/mL in plasma. The method had a lower limit of quantification of 1.0 ng/mL for artemisinin in 100 microL of plasma, which offered a satisfactory sensitivity for the determination of artemisinin. The intra- and inter-day precisions were measured to be within +/-5.3% and accuracy between -2.6% and 1.2% for all quality control samples, lower limit of quantification and upper limit of quantification samples. The extraction recoveries of artemisinin and the IS were 95.4 +/- 4.5% and 92.8 +/- 3.9%, respectively. This present method was successfully applied to the characterization of the pharmacokinetic profile of artemisinin in rats after oral administration.  相似文献   

7.
A sensitive gas chromatographic-mass spectrometric (GC-MS) procedure is described for the selective determination of gacyclidine (a non-competitive N-methyl-D-aspartate antagonist) in rat plasma and spinal cord dialyzates. It involves a single-step liquid-liquid extraction of plasma samples and dialyzates with hexane (pH 8.0) and the use of phencyclidine as an internal standard. The compounds were separated on a GC capillary column and specifically detected by MS in the selected-ion monitoring mode. Gacyclidine and its internal standard were monitored by using the fragment ions at m/z 206 and 200, respectively. The method was accurate and reproducible (intra- and inter-day reproducibility < 12%) with a limit of quantification of 1.6 ng ml-1 using 100 microliters plasma of dialyzate samples. The calibration curves for rat plasma and Ringer's solution were linear (r2 > 0.996) over a range from 1.6 to 200 ng ml-1. The extraction efficiency was close to 100%. This simple and rapid assay (total run time < 10 min) was validated for a pilot pharmacokinetic study in healthy rats after intravenous injection of a bolus dose of gacyclidine (2.5 mg kg-1).  相似文献   

8.
A sensitive and entirely automated solid-phase extraction/liquid chromatography/electrospray ionization tandem mass spectrometric (SPE/LC/ESI-MS/MS) method was developed and validated for the determination of eserine N-oxide (ENO), a cholinesterase inhibitor-like physostigmine in human plasma, for use in pharmacokinetic studies. ENO is light-sensitive and the use of a fully on-line process increased the reliability of the assay. Plasma samples previously mixed with neostigmine bromide to prevent in vitro degradation, and tacrine as internal standard (IS), were directly injected into the SPE/LC/ESI-MS/MS system. MS software piloted the overall system. MS/MS detection of ENO and the IS was performed in the positive ion ESI mode using multiple reaction monitoring. The linear calibration curve for ENO ranged from 25 pg ml(-1) to 12.5 ng ml(-1). The limit of quantitation was 25 pg ml(-1) with 250 microl of plasma injected. Precision, accuracy and stability tests were within the acceptable range and just one analyst is required to analyze 50 unknown samples a day five days per week, from the preparation of the samples (i.e. thawing and centrifugation) to data processing. A pilot pharmacokinetic study in three healthy volunteers treated with 4.5 mg of ENO (Génésérine3((R))) showed that the method was suitable for pharmacokinetic studies in humans.  相似文献   

9.
A hydrophilic interaction chromatography/mass spectrometry (HILIC‐MS)‐based assay for imipenem (IMP) and cilastatin (CIL) was recently reported. This orthogonal electrospray ion source‐based (ORS) assay utilized nonvolatile salt (unremovable) to stabilize IMI in plasma. Unfortunately, this method was not applicable to conventional MS with off‐axis spray (OAS‐MS) because MS sensitivity was rapidly deteriorated by the nonvolatile salt. Therefore, we aimed to find a nonvolatile salt‐ and ion suppression‐free approach to stabilize and measure the analytes in plasma using OAS‐MS. Acetonitrile and methanol were tested to stabilize the analytes in the plasma samples. The recoveries, matrix effects and stabilities of the analytes in the stabilizer‐treated samples were studied. The variations in MS signal intensities were used as the indicator of the assay ruggedness. The results show that a mixture of methanol and acetonitrile (1:1) is best for the storage and measurement of IMP and CIL in human plasma. Utilization of this precipitant not only blocked the hydrolysis of the analytes in plasma but also resulted in an ion suppression‐free, fast (120 s per sample) and sensitive detection. The sensitivity obtained using the less sensitive OAS‐MS (API3000, 4 pg on column) is much greater than that of the published ORS‐MS‐based assay (API4000, 77 pg on column). The ruggedness of the assay was demonstrated by its constant MS signal intensity. In conclusion, an improved HILIC/MS‐based assay for IMP and CIL was established. The approach presented here provides a simple solution to the challenge of analyzing hydrolytically unstable β‐lactam antibiotics in biological samples. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
A liquid chromatographic/tandem mass spectrometric (LC/MS/MS) method for the determination of the P-glycoprotein and breast cancer resistance protein inhibitor Elacridar in human and dog plasma is described. The internal standard was stable isotopically labelled Elacridar. Sample pretreatment involved liquid-liquid extraction with tert-butyl methyl ether. Analysis of Elacridar and internal standard was performed by reversed-phase LC on a basic stable minibore analytical column with an eluent consisting of acetonitrile and aqueous ammonia. An API-2000 triple-quadrupole mass spectrometer with an electrospray ion source was used in the positive-ion multiple reaction monitoring mode. The run time per sample was only 6 min. The method is sensitive and specific, with a dynamic range from 1 to 500 ng ml(-1) from 100 microl of human or dog plasma. The accuracy of the method was within 15% bias and the precision was lower than 15% for all tested concentration levels and in both matrices. The method is simple and the liquid-liquid extraction produces clean samples. This method was successfully applied to support the pharmacokinetics of a clinical trial in which orally applied Elacridar was used as a bioavailability enhancer.  相似文献   

11.
A sensitive and specific LC-MS/MS assay for the quantitative determination of EO9 and its metabolite EO5a is presented. A 200-microl human plasma aliquot was spiked with a mixture of deuterated internal standards EO9-d3 and EO5a-d4 and extracted with 1.25 ml ethyl acetate. Dried extracts were reconstituted in 0.1 M ammonium acetate-methanol (7 : 3, v/v) and 25 microl-volumes were injected into the HPLC system. Separation was achieved on a 150 x 2.1 mm C18 column using an alkaline eluent (1 mM ammonium hydroxide-methanol (gradient system)). Detection was performed by positive ion electrospray followed by tandem mass spectrometry. The assay quantifies a range from 5 to 2500 ng/ml for EO9 and from 10 to 2500 ng/ml EO5a using 200 microl of human plasma samples. Validation results demonstrate that EO9 and EO5a concentrations can be accurately and precisely quantified in human plasma. This assay will be used to support clinical pharmacologic studies with EO9.  相似文献   

12.
A simple, sensitive and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric method was developed and validated for the quantification of lacidipine in human plasma using its structural analogue, amlodipine, as internal standard (IS). The method involves a simple single-step liquid-liquid extraction with tert-butyl methyl ether. The analyte was chromatographed on an Xterra MS C(18) reversed-phase chromatographic column by isocratic elution with 20 mM ammonium acetate buffer-acetonitrile (10:90, v/v; pH 6) and analyzed by mass spectrometry in the multiple reaction monitoring mode. The precursor to product ion transitions of m/z 456.4 --> 354.4 and m/z 409.3 --> 238.3 were used to measure the analyte and the I.S., respectively. The chromatographic run time was 1.5 min and the weighted (1/x(2)) calibration curves were linear over the range 0.1-25 ng ml(-1). Lacidipine was sensitive to temperature in addition to light. The method was validated in terms of accuracy, precision, absolute recovery, freeze-thaw stability, bench-top stability and re-injection reproducibility. The limit of detection and lower limit of quantification in human plasma were 50 and 100 pg ml(-1), respectively. The within- and between-batch accuracy and precision were found to be well within acceptable limits (<15%). The analyte was stable after three freeze-thaw cycles (deviation <15%). The average absolute recoveries of lacidipine and amlodipine (IS) from spiked plasma samples were 51.1 +/- 1.3 and 50.3 +/- 4.9%, respectively. The assay method described here could be applied to study the pharmacokinetics of lacidipine.  相似文献   

13.
A simple, sensitive and rapid high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of pseudoephedrine in human plasma using mosapride as internal standard. Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple-reaction monitoring mode using the respective [M + H](+) ions, m/z 166/148 for pseuoephedrine and m/z 422/198 for the IS. The method exhibited a linear dynamic range of 2-1000 ng/mL pseudoephedrine in human plasma. The lower limit of quantification was 2 ng/mL with a relative standard deviation of less than 9% for pseudoephedrine. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The total chromatographic run time of 2 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

14.
A simple high performance liquid chromatography techniques with ultraviolet detection (HPLC–UV) method is described for the simultaneous determination of clozapine (CZP), clozapine N-oxide (CNO), N-desmethylclozapine (NCZ), risperidone (RSP) and 9-hydroxyrisperidone (9-OHRSP) in human plasma. After extraction process, the analytes were separated on a C18 column (150 mm×3.9 mm i.d.) by the mobile phase (methanol–water–dimethylamine, 60:40:0.04 (v:v:v)). Relative recoveries of five analytes were quantitative. The precision and accuracy of intra- and interday assays were all below 8.2% for R.S.D. and 5.6% for RE, respectively. Based on 1 ml of plasma, the limits of detection were 2.0 ng/ml for CZP, 0.2 ng/ml for CZP N-oxide, 1.0 ng/ml for NCZ, 1.0 ng/ml for RSP, and 0.5 ng/ml for 9-OHRSP (S/N=3). The calibration curves were linear (r≥0.988). This method was applied to therapeutic drug monitoring of schizophrenia patients receiving CZP or RSP therapy.  相似文献   

15.
A simple, sensitive and rapid high-performance liquid chromatography/electrospray ionization tandem mass spectrometry method was developed and validated for the assay of granisetron in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 313/138 for granisetron and m/z 409/228 for the IS. The assay exhibited a linear dynamic range of 0.1-20 ng/mL for granisetron in human plasma. The lower limit of quantification was 100 pg/mL with a relative standard deviation of less than 5%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.0 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

16.
A simple, rapid, and sensitive liquid chromatography-mass spectrometry (MS)-MS method for quantitating paclitaxel in rat plasma is developed. Liquid-liquid extraction with tert-butyl methyl ether is used for sample preparation, and docetaxel is used as the internal standard. Paclitaxel and docetaxel are separated on a C18 column and quantitated using a triple-quadrupole MS operating in positive ion electrospray selective reaction monitoring mode with a total run time of 6.0 min. The peak area of the m/z 876.3 --> 307.9 transition of paclitaxel is measured versus that of the m/z 830.3 --> 549.1 transition of docetaxel to generate the standard curve. The standard curve is linear over the concentration range of 0.2008-1004 ng/mL for rat plasma. The method has high extraction recovery (> 90%) and accuracy (> 90%), with the intra- and interday precision < 15%. Frozen stability, freeze-and-thaw stability, extracted stability, and room temperature solution stability are also examined. This assay is used to support a pharmacokinetic study of paclitaxel self-assembled nanoliposome in rats.  相似文献   

17.
A rapid, sensitive and specific high-performance liquid chromatography/electrospray ionization mass spectrometric (LC-ESI-MS) method was developed and validated for the quantification of madecassoside, a major active constituent of Centella asiatica (L.) Urb. herbs, in rat plasma. With paeoniflorin as an internal standard (IS), a simple liquid-liquid extraction process was employed for the plasma sample preparation. Chromatographic separation was achieved within 6 min on a Shim-pack CLC-ODS column using acetonitrile and water (60:40, v/v) containing 0.1% (v/v) formic acid as the mobile phase. The detection was performed by MS with electrospray ionization interface in negative selected ion monitoring (SIM) mode. The linear range was 11-5500 ng/mL with the square regression coefficient (r(2) ) of 0.9995. The lower limit of quantification was 11 ng/mL. The intra- and inter- day precision ranged from 4.99 to 9.03%, and the accuracy was between 95.82 and 111.80%. The average recoveries of madecassoside and IS from spiked plasma samples were >92%. The developed method was successfully applied to the pharmacokinetic study of madecassoside in rats after an oral administration.  相似文献   

18.
A reversed-phase HPLC method for the analysis of cephalexin (7-[(aminophenylacetyl)amino]-3-methyl-8-oxo-5-thia-1-azabicyclo[4.2.0]oct-2-ene-2-carboxylic acid) by isocratic separation is described. A comparison is made between the ultrafiltration land the extraction procedure developed in our laboratory. The extraction procedure, based on the deproteinization of plasma with perchloric acid followed by the extraction with dichloroethane and separation of cephalexin on a reversed phase column, gave better recovery. Quantitative validation of our method has been performed by an external standard technique. The relative standard deviations were between 1.1 and 1.9% in the within-day assay and between 1.2 and 2.2% in the inter-day assay. The limit of detection was 0.14ug/ml and the limit of quantification was 0.28ug/ml. This method is rapid, sensitive, simple, and reproducible. The LC MS/MS technique was successfully used for identification and quantification of cephalexin in human plasma samples.  相似文献   

19.
A rapid, simple and sensitive liquid chromatography–tandem mass spectrometry (LC/MS/MS) was developed for the determination of an antiepileptic drug, lacosamide, in rat plasma. The method involves the addition of acetonitrile and internal standard solution to plasma samples, followed by centrifugation. An aliquot of the supernatant was diluted with water and directly injected into the LC/MS/MS system. The separations were performed on column packed with octadecylsilica (5 µm, 2.0 × 50 mm) with 0.1% formic acid and acetonitrile as mobile phase, and the detection was performed on tandem mass spectrometry by the multiple‐reaction monitoring via an electrospray ionization source. The standard curve was linear over the concentration range from 0.3 to 1000 ng/mL. The lower limit of quantification was 0.3 ng/mL using 50 μL of rat plasma sample. The intra‐ and inter‐assay precision and accuracy were found to be less than 11.7 and 8.8%, respectively. The developed analytical method was successfully applied to the pharmacokinetic study of lacosamide in rats. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

20.
A rapid and sensitive method for the simultaneous confirmatory analysis of three forensic most relevant cannabinoids, Delta(9)-tetrahydrocannabinol (THC), 11-hydroxy-Delta(9)-tetrahydrocannabinol (11-OH-THC) and 11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol (THC-COOH), by means of high-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) in human plasma was developed and fully validated. Sample clean-up was performed by automated silica-based solid-phase extraction and the separation was carried out using a PhenylHexyl column (50 x 2 mm i.d., 3 micro m) and acetonitrile-5 mM ammonium acetate gradient elution. Data were acquired with an API 3000 LC/MS/MS system equipped with a turboionspray interface and triple quadrupole mass analyzer using positive electrospray ionization and multiple reaction monitoring. Two MS/MS transitions for each substance were monitored and deuterated analogues of analytes were used as internal standards for quantitation. The limit of quantitation was 0.8 ng ml(-1) for THC, 0.8 ng ml(-1) for 11-OH-THC and 4.3 ng ml(-1) for THC-COOH and linearity with a correlation coefficient r(2) = 0.999 was achieved up to 100 ng ml(-1) for THC and 11-OH-THC and 500 ng ml(-1) for THC-COOH. The limits of detection were 0.2 ng ml(-1) for THC, 0.2 ng ml(-1) for 11-OH-THC and 1.6 ng ml(-1) for THC-COOH. The developed LC/MS/MS method was also successfully used for the determination of THC-COOH-glucuronide, the phase II metabolite of THC-COOH.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号