首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Chao Guan  Hong Yu 《中国化学快报》2015,26(11):1371-1375
A method of hydrophilic interaction liquid chromatography with indirect ultraviolet detection was developed to determine three pyrrolidinium ionic liquid cations, i.e. N-methyl-N-ethyl pyrrolidinium cation ([MEPy]+), N-methyl-N-propyl pyrrolidinium cation ([MPPy]+) and N-methyl-N-butyl pyrrolidinium cation ([MBPy]+). Chromatographic separation was achieved on a hydrophilic column using imidazolium ionic liquids and organic solvents as the mobile phase. The effects of the background ultraviolet absorption reagents, the imidazolium ionic liquids, detection wavelength, organic solvents, column temperature and the pH value of the mobile phase on the separation and determination of pyrrolidinium cations were investigated and the retention behaviors in hydrophilic interaction chromatography were discussed. The optimized chromatographic conditions were selected. Under the optimal conditions, the detection limits (S/N = 3) for [MEPy]+, [MPPy]+ and [MBPy]+ were 0.59, 0.53 and 0.46 mg/L, respectively. The method has been successfully applied to the determination of the three ionic liquids synthesized in our chemistry laboratory. This research results may improve the analytical method of ionic liquid cations.  相似文献   

2.
In proteomics, nanoflow multidimensional chromatography is now the gold standard for the separation of complex mixtures of peptides as generated by in-solution digestion of whole-cell lysates. Ideally, the different stationary phases used in multidimensional chromatography should provide orthogonal separation characteristics. For this reason, the combination of strong cation exchange chromatography (SCX) and reversed-phase (RP) chromatography is the most widely used combination for the separation of peptides. Here, we review the potential of hydrophilic interaction liquid chromatography (HILIC) as a separation tool in the multidimensional separation of peptides in proteomics applications. Recent work has revealed that HILIC may provide an excellent alternative to SCX, possessing several advantages in the area of separation power and targeted analysis of protein post-translational modifications. Figure Artistic impression of the HILIC separation mechanism  相似文献   

3.
Organic acids with very low pKa require extremely low pH conditions to achieve adequate retention in reversed‐phase liquid chromatography, but an extremely low pH mobile phase can cause instrument reliability problems and limit the choice of columns. Hydrophilic interaction chromatography is a potential alternative to reversed‐phase liquid chromatography for the separation of organic acids using more moderate conditions. However, the hydrophilic interaction chromatography separation mechanism is known to be very complex and involves multiple competing mechanisms. In the present study, a hydrophilic interaction chromatography column packed with bare silica core–shell particles was used as the separation column and six agricultural organic acids were used as model analytes to evaluate the effects of buffer concentration, buffer pH, and temperature on sample loading capacity, selectivity, retention, and repeatability. It was found that using a higher concentration of buffer can lead to a significant improvement in the overall performance and reproducibility of the separation. Investigation of column equilibration time revealed that a very long equilibration time is needed when changing mobile phase conditions in between runs. This limitation needs to be acknowledged in hydrophilic interaction chromatography method development and sufficient equilibration time needs to be allowed in method scouting.  相似文献   

4.
Hydrophilic interaction liquid chromatography (HILIC) was used to separate monosaccharides that are common in N-linked oligosaccharides in glycoproteins and other compounds. A TSKgel Amide-80 column was eluted with 82% acetonitrile, in 5 mM ammonium formate (pH 5.5). Column temperature was 60 degrees C and evaporative light scattering was used for detection (ELSD). With this method, L-fucose, D-galactose, D-mannose, N-acetyl-D-glucosamine, N-acetylneuraminic acid, and D-glucuronic acid were separated, with detection limits of 0.3-0.5 microg for each monosaccharide, and intermediate precisions were 3-6% RSD (n=6).  相似文献   

5.
The most separations in HILIC mode are performed on silica-based supports. Nevertheless, recently published results have indicated that the metal oxides stationary phases also possess the ability to interact with hydrophilic compounds under HILIC conditions. This paper primarily describes the retention behaviour of model hydrophilic analytes (4-aminobenzene sulfonic acid, 4-aminobenzoic acid, 4-hydroxybenzoic acid, 3,4-diaminobenzoic acid, 3-aminophenol and 3-nitrophenol) on the polybutadine modified zirconia in HILIC. The results were simultaneously compared with a bare zirconia and a silica-based HILIC phase. The mobile phase strength, pH and the column temperature were systematically modified to assess their impact on the retention of model compounds. It was found that the retention of our model hydrophilic analytes on both zirconia phases was mainly governed by adsorption while on the silica-based HILIC phase partitioning was primarily involved. The ability of ligand-exchange interactions of zirconia surface with a carboxylic moiety influenced substantially the response of carboxylic acids on the elevated temperature as well as to the change of the mobile phase pH in contrast to the silica phase. However, no or negligible ligand-exchange interactions were observed for sulfanilic acid. The results of this study clearly demonstrated the ability of modified zirconia phase to retain polar acidic compounds under HILIC conditions, which might substantially enlarge the application area of the zirconia-based stationary phases.  相似文献   

6.
亲水作用液相色谱法(HILIC)是一种用于改善强极性物质的保留和分离选择性的方法,广泛应用于药物分析、代谢组学、蛋白质组学等领域.该文利用农药分子与皂苷成分在HILIC上的保留行为差异,开发了一种农药残留脱除方法.以市售高纯人参提取物为例,该文评价了农药分子和人参皂苷在亲水色谱柱上的保留行为,并考察了上样量、淋洗体积、...  相似文献   

7.
This paper presents a systematic study of the retention behavior of a model bisdioxopiperazine drug, dexrazoxane (DEX) and its three polar metabolites (two single open-ring intermediates-B and C and an EDTA-like active compound ADR-925) on different stationary phases intended for hydrophilic interaction liquid chromatography (HILIC). The main aim was to estimate advantages and limitations of HILIC in the simultaneous analysis of a moderately lipophilic parent drug and its highly polar metabolites, including positional isomers, under MS compatible conditions. The study involved two bare silica columns (Ascentic Express HILIC, Atlantis HILIC) and two stationary phases with distinct zwitterionic properties (Obelisc N and ZIC HILIC). The chromatographic conditions (mobile phase strength and pH, column temperature) were systematically modified to assess their impact on retention and separation of the studied compounds. It was found that the bare silica phases were unable to separate the positional isomers (intermediates B and C), whereas both columns with zwitterionic properties (Obelisc N and ZIC HILIC) were able to separate these structurally very similar compounds. However, only ZIC HILIC phase allowed appropriate separation of DEX and all its metabolites to a base line within a single run. A mobile phase composed of a mixture of ammonium formate (0.5 mM) and acetonitrile (25:75, v/v) was suggested as optimal for the simultaneous analysis of DEX and its metabolites on ZIC HILIC. Thereafter, HILIC-LC-MS analysis of DEX and all its metabolites was performed for the first time to obtain basic data about the applicability of the suggested chromatographic conditions. Hence, this study demonstrates that HILIC could be a viable solution for the challenging analysis of moderately polar parent drug along with its highly polar metabolites including the ability to separate structurally very similar compounds, such as positional isomers.  相似文献   

8.
A hydrophilic interaction liquid chromatography (HILIC) method was developed to measure the composition of humic substances from river, reservoir, and treated wastewater based on their physicochemical properties. The current method fractionates the humic substances into four well-defined groups based on parallel analyses with a neutral and a cationic HILIC column, using mobile phases of varied compositions and pH. The results indicate that: (i) the proportion of carboxylic acids in the humic substances from terrestrial origins is less than half of that from treated wastewater (Jeddah, KSA), (ii) a higher content of basic compounds was observed in the humic substances from treated wastewater and Ribou Reservoir (Cholet, France) than in the sample from Loire River (France), (iii) a higher percentage of hydrophobic macromolecules were found in the humic substances from Loire River than in the other samples, and (iv) humic substances of treated wastewater contained less ionic neutral compounds (i.e., pKa 5–9) than the waters from terrestrial origins. The physicochemical property disparity amongst the compounds in each humic substances sample was also evaluated. The humic substances from the lightly humic Loire river displayed the highest disparity, whereas the highly humic Suwannee river (Georgia, USA) showed the most homogeneous humic substances.  相似文献   

9.
Nowadays there are limited types of commercially available stationary phases for hydrophilic interaction liquid chromatography and therefore new ones with unique selectivity are urgently in demand to meet the need of separations of various polar and hydrophilic analytes. The present study describes the preparation and evaluation of a new stationary phase based on thiourea derivative modified silica for hydrophilic interaction liquid chromatography. Thiourea derivative was bonded onto the surface of silica particles via a mild addition reaction between –NH2 and –SCN, and the result of elemental analysis together with infrared analysis and solid‐state NMR spectroscopy proved that the synthesis method was feasible. The new stationary phase succeeded in fast separations of a wide range of polar and hydrophilic analytes and exhibited excellent separation performance, especially unique selectivity. Furthermore, the effects of water content, buffer pH, and salt concentration on retention indicated that a complicated separation mechanism rather than partitioning was involved in the stationary phase and hydrogen bonding interaction between analytes and thiourea functional group could play a very important role in its selectivity. For sure, the new stationary phase is of a great potential as a new type of hydrophilic interaction liquid chromatographic stationary phase.  相似文献   

10.
Hydrophilic interaction liquid chromatography (HILIC) was examined for the separation of paralytic shellfish poisoning (PSP) toxins using the stationary phase TSK-gel Amide-80. The parameters tested included type of organic modifier and percentage in the mobile phase, buffer concentration, pH, flow rate and column temperature. Using mass spectrometric (MS) detection, the HILIC column allowed the determination of all the major PSP toxins in one 30 min analysis with a high degree of selectivity and sensitivity. The high percentage of organic modifier in the mobile phase and the omission of ion pairing reagents, both favored in HILIC, provided limits of detection (LOD) in the range 50-100 nM in selected ion monitoring (SIM) mode on a single quadrupole LC-MS system. LOD in selected reaction monitoring (SRM) mode on a sensitive triple quadrupole system were as low as 5-30 nM. Excellent linearity of response was observed.  相似文献   

11.
The analysis of amino acids presents significant challenges to contemporary analytical separations. The present paper investigates the possibility of retention prediction in hydrophilic interaction chromatography (HILIC) gradient elution based on the analytical solution of the fundamental equation of the multilinear gradient elution derived for reversed‐phase systems. A simple linear dependence of the logarithm of the solute retention (ln k) upon the volume fraction of organic modifier (φ) in a binary aqueous‐organic mobile is adopted. Utility of the developed methodology was tested on the separation of a mixture of 21 amino acids carried out with 14 different gradient elution programs (from simple linear to multilinear and curved shaped) using ternary eluents in which a mixture of methanol and water (1:1, v/v) was the strong eluting member and acetonitrile was the weak solvent. Starting from at least two gradient runs, the prediction of solute retention obtained under all the rest gradients was excellent, even when curved gradient profiles were used. Development of such methodologies can be of great interest for a wide range of applications.  相似文献   

12.
A promising alternative to ion-chromatographic methods currently used for the direct determination of hydrazines is provided by hydrophilic interaction liquid chromatography (HILIC). In this work, we propose a method for the simultaneous determination of hydrazine, methylhydrazine and 1,1-dimethylhydrazine in natural waters and soils based on a combination of chromatographic separation on a zwitterionic sulfobetaine stationary phase (Nucleodur HILIC) in the HILIC mode with amperometric detection.

Effects of different factors on the retention of analytes were studied and the optimum conditions of analysis were found. We recommend a mixture of acetonitrile with an aqueous phosphate buffer solution of pH 2.5 (78:22 v/v) with an ionic strength of 20 mM as a mobile phase. Detection in the direct current mode was performed at a working electrode potential of 1.1 V.

The advantages of the method are the high efficiency of separation, rapidity, high sensitivity and a wide dynamic range of analyte concentrations, covering four orders of magnitude. The attained LOD values for analytes lie in the range 0.07–0.13 μg L–1, which is two orders of magnitude lower than those in currently used methods of ion chromatography with electrochemical and mass spectrometric detection.

The method was validated on samples of natural waters of different origin using the added–found technique. It was found that the error of analysis did not exceed 10% for river and ground waters and increased to 20–30% for peat bog surface waters.

The possibility of application of the developed method to the analysis of soils was shown on samples of peat bog soils selected at places of impact of the first steps of carrier rockets and polluted by rocket fuel based on 1,1-dimethylhydrazine.  相似文献   

13.
A systematic strategy based on hydrophilic interaction liquid chromatography was developed for the separation, purification and quantification of raffinose family oligosaccharides from Lycopus lucidus Turcz. Methods with enough hydrophilicity and selectivity were utilized to resolve the problems encountered in the separation of oligosaccharides such as low retention, low resolution and poor solubility. The raffinose family oligosaccharides in L. lucidus Turcz. were isolated using solid‐phase extraction followed by hydrophilic interaction liquid chromatography at semi‐preparative scale to obtain standards of stachyose, verbascose and ajugose. Utilizing the obtained oligosaccharides as standards, a quantitative determination method was developed, validated and applied for the content determination of raffinose family oligosaccharides both in the aerial and root parts of L. lucidus Turcz. There were no oligosaccharides in the aerial parts, while in the root parts, the total content was 686.5 mg/g with the average distribution: raffinose 66.5 mg/g, stachyose 289.0 mg/g, verbascose 212.4 mg/g, and ajugose 118.6 mg/g. The result provided the potential of roots of L. lucidus Turcz. as new raffinose family oligosaccharides sources for functional food. Moreover, since the present systematic strategy is efficient, sensitive and robust, separation, purification and quantification of oligosaccharides by hydrophilic interaction liquid chromatography seems to be possible.  相似文献   

14.
A fast, selective, and sensitive method for the determination of three monosaccharide anhydrides (galactosan, mannosan, levoglucosan), based on hydrophilic interaction chromatography and Fourier transform mass spectrometry, was successfully developed. The simple experimental stationary phase and mass spectrometry performance screening allowed the selection of the best available chromatographic and mass spectrometry conditions. Thus, the chromatographic separation was performed on a highly selective stationary phase containing a zwitterionic phosphorylcholine group and the monosaccharide anhydrides were detected as [M+HCOO]? adduct in the negative mode. The method showed accuracy in the range of 84–111 and 89–102% with interbatch precision expressed as relative standard deviations of 5.6–15.4 and 5.0–9.0% for the aerosol extract and snow samples, respectively. The limit of quantification in absolute values ranged from 10 to 30 pg, the limit of quantification, expressed as concentration, ranged was 0.3–0.9 ng/m3 for aerosol and 10–20 ng/mL for snow samples. The method was successfully applied for the determination of monosaccharide anhydrides in aerosol and snow samples.  相似文献   

15.
The overloaded band profiles of the protonated species of propranolol and amitriptyline were recorded under acidic conditions on four classes of stationary phases including a conventional silica/organic hybrid material in reversed‐phase liquid chromatography mode (BEH‐C18), an electrostatic repulsion reversed‐phase liquid chromatography C18 column (BEH‐C18+), a poly(styrene‐divinylbenzene) monolithic column, and a hydrophilic interaction chromatography stationary phase (underivatized BEH). The same amounts of protonated bases per unit volume of stationary phase were injected in each column (16, 47, and 141 μg/cm3). The performance of the propranolol/amitriptyline purification was assessed on the basis of the asymmetry of the recorded band profiles and on the selectivity factor achieved. The results show that the separation performed under reversed‐phase liquid chromatography like conditions (with BEH‐C18, BEH‐C18+, and polymer monolith materials) provide the largest selectivity factors due to the difference in the hydrophobic character of the two compounds. However, they also provide the most distorted overloaded band profiles due to a too small loading capacity. Remarkably, symmetric band profiles were observed with the hydrophilic interaction chromatography column. The larger loading capacity of the hydrophilic interaction chromatography column is due to the accumulation of the protonated bases into the diffuse water layer formed at the surface of the polar adsorbent. This work encourages purifying ionizable compounds on hydrophilic interaction chromatography columns rather than on reversed‐phase liquid chromatography columns.  相似文献   

16.
Fingerprint analysis is considered one of the most powerful approaches to quality control in traditional Chinese medicines (TCMs). In this study, a binary chromatographic fingerprint analysis was developed using hydrophilic interaction chromatography (HILIC) and reversed-phase liquid chromatography (RPLC) to gain more chemical information about polar compounds and weakly polar compounds. This method was used to construct a chromatographic fingerprint of Ligusticum chuanxiong. The two chromatographic methods demonstrated good precision, reproducibility, and stability, with relative standard deviations of <2% for retention time and 7% for peak area for both HILIC and RPLC separations. Data from the analysis of 14 samples by HILIC and RPLC were processed with similarity analysis, with correlation coefficients and congruence coefficients. This binary fingerprint analysis, using two chromatographic modes, is a powerful tool for characterizing the quality of samples, and can be used for the comprehensive quality control of TCMs.  相似文献   

17.
A new isocratic separation method was developed for separation of phospholipid (PL) classes based on a silica hydrophilic interaction liquid chromatography (HILIC) column with electrospray ionization (ESI) mass spectrometric detection. Although HILIC is typically used for polar compounds, also amphiphilic molecules like phospholipids can be separated very well. Compared to normal-phase (NP) chromatography, which is usually used for PL class separation, HILIC has the advantage to use on-line ESI-MS detection because its eluents are ESI compatible. Furthermore, this HILIC method is isocratic and hence less time consuming than most (gradient) NP HPLC methods. A chromatographic baseline separation of a standard mixture containing phosphatidylglycerol (PG), phosphatidylethanolamine (PE), phosphatidylcholine (PC), sphingomyelin (SM) and lysophosphatidylcholine (LPC) was achieved within a total run time of 17 min using a mobile phase consisting of acetonitrile, methanol and ammonium acetate 10 mM. The new method was subsequently tested on phospholipid fractions of a body fluid (human blood plasma) and a tissue extract (swine brain) whereby it achieved nearly the same baseline separation of the PL classes. The detected classes in both cases were PE, PC, SM and LPC.  相似文献   

18.
In this work, a revisit to the retention mechanism of HILIC was attempted to point out critical factors that contribute to the chromatographic regime as well as to bring out subtle details of the relative contribution of partitioning and surface adsorption. In this vein, the retention behaviour of a set of water-soluble vitamins (WSVs) and toluene on three silica based columns was evaluated under varying chromatographic conditions. The data obtained were associated with the hydration degree of the stationary phases and the ability of the organic solvents to disrupt the formation of the water-enriched layer. Moreover, the elution behaviour of toluene at different buffer salt concentrations in the mobile phase, confirmed the preferential partition of salt ions into the stagnant layer, as ACN content was increased. The results from the fitting of partitioning and surface adsorption models indicated differences in the contribution of the two retention mechanisms to both neutral and charged compounds. The occurrence of surface adsorption and the retentivity differences for neutral WSVs depend on the hydration degree and the hydrogen bonding properties of the solutes and the column surface, respectively. For charged solutes experiencing electrostatic repulsion, the contribution of the adsorption mechanism at highly organic mobile phases, emanates from both the weak effect of buffer salt ions on the electrostatic interaction and the strong effect of hydrophilic interactions. On the other hand, the chromatographic retention of electrostatically attracted solutes indicates that the surface adsorption dominates, even at mobile phases rich in water.  相似文献   

19.
We report a column-switching liquid chromatography (LC) tandem mass spectrometry (MS/MS) method for highly sensitive determination of both free estrogens (estrone, estradiol, and estriol) and their conjugates (estrone-3-sulfate, estradiol-3-sulfate, estriol-3-sulfate, estrone-3-glucuronide, estradiol-3-glucuronide, estriol-16-glucuronide, and estriol-3-glucuronide) in river water. This technique combines reversed phase (RP) chromatographic separation of the dansyl chloride derivatized free estrogens and hydrophilic interaction liquid chromatographic (HILIC) separation of the estrogen conjugates with multiple reaction monitoring (MRM). Using this new method, sensitivity increases 100- to 1000-fold for free estrogens and 2- to 10-fold for estrogen conjugates over RPLC-MS/MS alone. Method detection limits (MDL) range from 0.038 to 6.9 ng L−1 with accuracy of 68-105% and precision of 1.7-17%. We successfully used this method to analyze river water samples collected from the North Saskatchewan River at the same location and detected trace concentrations of estrone (0.042 ng L−1) and estrone-3-sulfate (0.84 ng L−1), demonstrating the application of this method for environmental analysis.  相似文献   

20.
Guo Y  Yuan Q  Li R  Huang Y 《色谱》2012,30(3):232-238
亲水作用色谱(HILIC)是一种分离极性和亲水性化合物的液相色谱模式,其作为反相液相色谱(RPLC)的重要补充,近年来越来越受到各个领域的关注和重视。这不只是因为强极性化合物的分离问题在各个领域引起了重视,而且因为与RPLC比较,HILIC具有流动相组成黏度低、色谱柱渗透性好、与质谱联用的灵敏度高及反压较低等优势。本文简要概述了HILIC的发展历程、特点及保留机理,重点介绍了HILIC用于环境分析的最新进展,评述了HILIC及RPLC用于污染物分析的优缺点,并指出了HILIC用于环境分析的未来发展趋势。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号