首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Convective interaction media (CIM) monoliths provide a stationary phase with a high binding capacity for large molecules and are capable of high flow rates at a very low pressure drop. Used as anion- and cation-exchangers or with affinity ligands such as antibodies, these columns have the potential for processing large volumes of complex biological mixtures within a short time. In the present report, monoclonal antibodies against several rat liver plasma membrane proteins were bound and cross-linked to protein A or protein G CIM affinity columns with a bed volume of only 60 microL. Antigens recognized by bound antibodies and co-eluting (interacting) proteins were rapidly isolated in a single step from either total plasma membrane extracts or subfractions isolated using anion-exchange CIM disk-shaped columns. The isolated antigens and co-eluting proteins were subsequently identified by immunoblot or by LC-MS/MS.  相似文献   

2.
Certain diagnostic, analytical and preparative applications require the separation of immunoglobulin G (IgG) from immunoglobulin M (IgM). In the present work, different ion-exchange methacrylate monoliths were tested for the separation of IgG and IgM. The strong anion-exchange column had the highest dynamic binding capacity reaching more than 20mg of IgM/ml of support. Additionally, separation of IgM from human serum albumin, a common contaminant in immunoglobulin purification, was achieved on the weak ethylenediamino anion-exchange column, which set the basis for the IgM purification method developed on convective interaction media (CIM) supports. Experiments also confirmed flow independent characteristics of the short monolithic columns.  相似文献   

3.
Affinity monolith chromatography (AMC) is a type of liquid chromatography that uses a monolithic support and a biologically related binding agent as a stationary phase. AMC is a powerful method for the selective separation, analysis, or study of specific target compounds in a sample. This review discusses the basic principles of AMC and recent developments and applications of this method, with particular emphasis being given to work that has appeared in the last 5 years. Various materials that have been used to prepare columns for AMC are examined, including organic monoliths, silica monoliths, agarose monoliths, and cryogels. These supports have been used in AMC for formats that have ranged from traditional columns to disks, microcolumns, and capillaries. Many binding agents have also been employed in AMC, such as antibodies, enzymes, proteins, lectins, immobilized metal ions, and dyes. Some applications that have been reported with these binding agents in AMC are bioaffinity chromatography, immunoaffinity chromatography or immunoextraction, immobilized-metal-ion affinity chromatography, dye–ligand affinity chromatography, chiral separations, and biointeraction studies. Examples are presented from fields that include analytical chemistry, pharmaceutical analysis, clinical testing, and biotechnology. Current trends and possible directions in AMC are also discussed.  相似文献   

4.
Monolithic capillary columns with surface bound lectin affinity ligands were introduced for performing lectin affinity chromatography (LAC) by nano-liquid chromatography (nano-LC). Two kinds of polymethacrylate monoliths were prepared, namely poly(glycidyl methacrylateco-ethylene dimethacrylate) and poly(glycidyl methacrylate-co-ethylene dimethacrylate-co-[2-(methacryloyloxy)ethyl]trimethyl ammonium chloride) to yield neutral and cationic macroporous polymer, respectively. Two lectins including concanavalin (Con A) and wheat germ agglutinin (WGA) were immobilized onto the monolithic capillary columns. The neutral monoliths with immobilized lectins exhibited lower permeability under pressure driven flow than the cationic monoliths indicating that the latter had wider flow-through pores than the former. Both types of monoliths with immobilized lectins exhibited strong affinity toward particular glycoproteins and their oligosaccharide chains (i.e., glycans) having sugar sequences recognizable by the lectin. Due to the strong binding affinity, the monoliths with surface bound lectins allowed the injection of relatively large volume (i.e., several column volumes) of dilute samples of glycoproteins and glycans thus allowing the concentration of the glycoconjugates and their subsequent isolation and detection at low levels (approximately 10(-8) M). To further exploit the lectin monoliths in the isolation of glycoconjugates, two-dimensional separation schemes involving LAC in the first dimension and reversed-phase nano-LC in the second dimension were introduced. The various interrelated methods established in this investigation are expected to play a major role in advancing the sciences of "nano-glycomics".  相似文献   

5.
Okanda FM  El Rassi Z 《Electrophoresis》2006,27(5-6):1020-1030
In this report, microcolumn separation schemes involving monolithic capillary columns with immobilized lectins, and relevant to nanoglycomics/nanoproteomics were introduced. Positive and neutral monoliths based on poly(glycidyl methacrylate-co-ethylene dimethacrylate) were designed for achieving lectin affinity chromatography (LAC) by nano-LC and CEC. The positive monoliths (i.e., monoliths with cationic sites) afforded relatively high permeability in nano-LC but lack predictable EOF magnitude and direction, while neutral monoliths provided a good compromise between reasonable permeability in nano-LC and predictable EOF in CEC. Lectin affinity nano-LC permitted the enrichment of classes of different glycoproteins having similar N-glycans recognized by the immobilized lectin, whereas lectin affinity CEC provided the simultaneous capturing and separation of different glycoproteins due to differences in charge-to-mass ratio. Also, this investigation demonstrated for the first time the coupling of lectin capillary columns in series (i.e., tandem columns) for enhanced separation of glycoproteins by LAC using the CEC modality. Furthermore, in the coupled columns format, glycoforms of a given glycoprotein were readily separated.  相似文献   

6.
Yang W  Sun X  Pan T  Woolley AT 《Electrophoresis》2008,29(16):3429-3435
Developments in biology are increasing demands for rapid, inexpensive, and sensitive biomolecular analysis. In this study, polymer microdevices with monolithic columns and electrophoretic channels were used for biological separations. Glycidyl methacrylate-co-ethylene dimethacrylate monolithic columns were formed within poly(methyl methacrylate) microchannels by in situ photopolymerization. Flow experiments in these columns demonstrated retention and then elution of amino acids under conditions optimized for sample preconcentration. To enhance analyte selectivity, antibodies were immobilized on monoliths, and subsequent lysozyme treatment blocked nonspecific adsorption. The enrichment capability and selectivity of these affinity monoliths were evaluated by purifying fluorescently tagged amino acids from a mixture containing green fluorescent protein (GFP). Twenty-fold enrichment and 91% recovery were achieved for the labeled amino acids, with a >25 000-fold reduction in GFP concentration, as indicated by microchip electrophoresis analysis. These devices should provide a simple, inexpensive, and effective platform for trace analysis in complex biological samples.  相似文献   

7.
Monoclonal antibodies (MAbs) have diverse applications in diagnostics and therapeutics. The recent advancement in hybridoma technology for large‐scale production of MAbs in bioreactors demands rapid and efficient purification methods. Conventional affinity purification systems have drawbacks of low flow rates and denaturation of antibodies owing to harsh elution conditions. Here, we attempted purification of MAbs by use of a high‐throughput metal–chelate methacrylate monolithic system. Monolithic macroporous convective interaction media–iminodiacetate (CIM‐IDA) disks immobilized with four different metal ions (Cu2+, Ni2+, Zn2+ and Co2+) were used and evaluated for purification of anti‐human serum albumin IgG1 mouse MAbs from cell culture supernatant after precipitation with 50% ammonium sulfate. Elution with 10 mM imidazole in the equilibration buffer (25 mM MMA = MOPS (Morpholino propane sulfonic acid) + MES (Morpholino ethane sulfonic acid) + Acetate + 0.5 M NaCl, pH 7.4) resulted in a purification of 25.7 ± 2.9‐fold and 32.5 ± 2.6‐fold in experiments done using Zn2+ and Co2+ metal ions, respectively. The highest recovery of 85.4 ± 1.0% was obtained with a CIM‐IDA‐Zn(II) column. SDS–PAGE, ELISA and immuno‐blot showed that the antibodies recovered were pure, with high antigen‐binding efficiency. Thus, metal chelate CIM monoliths could be a potential alternative to conventional systems for fast and efficient purification of MAbs from the complex cell culture supernatant. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

8.
《Analytical letters》2012,45(2):267-278
Abstract

Immunoaffinity chromatography (IAC) provides a selective method for sample preparation prior to high-performance liquid chromatography (HPLC) or gas chromatography (GC). Five different support materials were tested for their suitability with regard to IAC of herbicides (s-triazines). Three gels showing low (0-10 %) nonspecific s-triazine adsorption were used as affinity supports (Beaded cellulose ONB-carbonate A, LiChroprep hydrazide tentacle gel and LiChroprep azlactone gel). A monoclonal antibody (K4E7), directed against atrazine, was covalently coupled to the gels. High antibody immobilization rates (100 %) were obtained with the beaded cellulose gel in comparison to the other gels (60-70 %). Subsequently the IAC columns were loaded with triazine solutions. Glycine-HCl 0.2 mol/L, pH 2.2 yielded the best results for the elution of the bound triazines from the beaded cellulose IAC columns (70-100 %). Both the hydrazide tentacle and the azlactone IAC columns showed lower elution rates (60-80 %).  相似文献   

9.
Affinity chromatography on monolithic supports is a powerful analytical chemical platform because it allows for fast analyses, small sample volumes, strong enrichment of trace biomarkers and applications in microchips. In this review, the recent research using monolithic materials in the field of bioaffinity chromatography (including immunochromatography) is summarized and discussed. After giving an introduction into affinity chromatography, information on different biomolecules (antibodies, enzymes, lectins, aptamers) that can act as ligands in bioaffinity chromatography is presented. Subsequently, the history of monoliths, their advantages, preparation and formats (disks, capillaries and microchips) as well as ligand immobilization techniques are mentioned. Finally, analytical and preparative applications of bioaffinity chromatography on monoliths are presented. During the last four years 37 papers appeared. Protein A and G are still most often used as ligands for the enrichment of immunoglobulins. Antibodies and lectins remain popular for the analysis of mainly smaller molecules and saccharides, respectively. The highly porous cryogels modified with ligands are applied for the sorting of different cells or bacteria. New is the application of aptamers and phages as ligands on monoliths. Convective interaction media (epoxy CIM disks) are currently the most used format in monolithic bioaffinity chromatography.  相似文献   

10.
Yang F  Lin Z  He X  Chen L  Zhang Y 《Journal of chromatography. A》2011,1218(51):9194-9201
A macroporous boronate affinity monolithic column was prepared and applied to specifically capture glycoproteins using metal-organic gels (MOGs) as a porogenic template. This newly explored application of MOGs has proven to be a more convenient method for the formation of macropores in contrast to traditional porogenic methods. The poly (3-acrylamidophenylboronic acid-co-ethylene dimethacrylate) monolithic columns were synthesized in stainless columns by in situ polymerization. To fabricate the macroporous formation with a uniformed open-channel network, the preparation conditions, such as reaction temperature, the concentration of the MOGs and the ratio of monomers were systematically investigated. The prepared macroporous monoliths were characterized by scanning electron microscope (SEM) and mercury intrusion porosimetry. Furthermore, horseradish peroxidase (HRP) and transferrin (TF) were chosen as test glycoproteins, and the chromatographic analysis demonstrated that the macroporous boronate affinity monoliths exhibited a higher selectivity and better dynamic binding capacity toward glycoproteins compared with non-glycoproteins. The resulted affinity monolithic column was successfully employed to specifically capture TF from a bovine serum sample.  相似文献   

11.
Lectin‐functionalized monolithic columns were prepared within polyether ether ketone (PEEK) columns (150 × 4.6 mm id) via transition metal‐catalyzed ring‐opening metathesis polymerization of norborn‐2‐ene (NBE) and trimethylolpropane‐tris(5‐norbornene‐2‐carboxylate) (CL) using the first‐generation Grubbs initiator RuCl2(PCy3)2(CHPh) (1, Cy = cyclohexyl) in the presence of a macro‐ and microporogen, i.e. of 2‐propanol and toluene. Postsynthesis functionalization was accomplished via in situ grafting of 2,5‐dioxopyrrolidin‐1‐yl‐bicyclo[2.2.1]hept‐5‐ene‐2‐carboxylate to the surface of the monoliths followed by reaction with α,ω‐diamino‐poly(ethyleneglycol). The pore structure of the poly(ethyleneglycol)‐ derivatized monoliths was investigated by electron microscopy and inverse‐size exclusion chromatography, respectively. The amino‐poly(ethyleneglycol) functionalized monolithic columns were then successfully used for the immobilization of lectin from Lens culinaris hemagglutinin. The thus prepared lectin‐functionalized monoliths were applied to the affinity chromatography‐based purification of glucose oxidase. The binding capacity of Lens culinaris hemagglutinin‐immobilized monolithic column for glucose oxidase was found to be 2.2 mg / column.  相似文献   

12.
Hydrophilic poly(ethylene glycol)-based monoliths were synthesized in the spin-tip format for high-throughput applications via pulsed electron beam irradiation. Monoliths with a homogeneous porous structure and a total porosity of 69% were obtained. The cross-linked polymeric structure was further mechanically stabilized via the incorporation of silica nanoparticles. Amino-functionalization of the monoliths was accomplished by a straightforward, water-based, one-step approach that entailed the electron-beam irradiation-induced grafting of poly(allylamine). The amine functionalized spin columns showed very low unspecific protein adsorption and were successfully applied as adsorbents in lectin affinity chromatography for the purification of ovalbumin. The novel columns also outperformed a commercially available system.  相似文献   

13.
Monoliths are attractive stationary phases for purification of large biomolecules like proteins because of their flow-unaffected properties. Isolation of histidine containing proteins to high purity can be efficiently performed using metal-chelate interactions within a single chromatographic step. In this work, we investigated properties of commercial metal-chelate methacrylate monoliths-Convective Interaction Media (CIM). Analytical CIM disk monolithic columns and CIM 8 ml monolithic columns were used for purification of tumor necrosis factor-alpha (TNF-alpha) analog LK-801 and green fluorescence protein with 6 histidine tag (GFP-6His). In both cases, purity over 90% was achieved. Dynamic binding capacity at 10% of breakthrough was around 17-18 mg/ml for LK-801 and around 30 mg/ml for GFP-6His. Adsorption isotherm revealed that the maximal capacity is achieved at protein concentration above 60 microg/ml. Dynamic binding capacity and resolution were found to be flow unaffected.  相似文献   

14.
A poly(glycidyl methacrylate-co-acrylamide-co-ethylene dimethacrylate) monolith and a poly(glycidyl methacrylate-co-ethylene dimethacrylate) monolith were prepared in fused silica capillaries (100 μm ID) and modified with monomeric avidin using the glutaraldehyde technique. The biotin binding capacity of monolithic affinity columns with immobilized monomeric avidin (MACMAs) was determined by fluorescence spectroscopy using biotin (5-fluorescein) conjugate, as well as biotin- and fluorescein-labeled bovine serum albumin (BSA). The affinity columns were able to bind 16.4 and 3.7 μmol biotin/mL, respectively. Columns prepared using the poly(glycidyl methacrylate-co-ethylene dimethacrylate) monolith retained 7.1 mg BSA/mL, almost six times more than commercially available monomeric avidin beads. Protocols based on MALDI-TOF mass spectrometry monitoring were optimized for the enrichment of biotinylated proteins and peptides. A comparison of enrichment efficiencies between MACMAs and commercially available monomeric avidin beads yielded superior results for our novel monolithic affinity columns. However, the affinity medium presented in this work suffers from a significant degree of nonspecific binding, which might hamper the analysis of more complex mixtures. Further modifications of the monolith’s surface are envisaged for the future development of monoliths with improved enrichment characteristics.  相似文献   

15.
Pressure drop analysis in commercial CIM disk monolithic columns is presented. Experimental measurements of pressure drop are compared to hydrodynamic models usually employed for prediction of pressure drop in packed beds, e.g. free surface model and capillary model applying hydraulic radius concept. However, the comparison between pressure drop in monolith and adequate packed bed give unexpected results. Pressure drop in a CIM disk monolithic column is approximately 50% lower than in an adequate packed bed of spheres having the same hydraulic radius as CIM disk monolith; meaning they both have the same porosity and the same specific surface area. This phenomenon seems to be a consequence of the monolithic porous structure which is quite different in terms of the pore size distribution and parallel pore nonuniformity compared to the one in conventional packed beds. The number of self-similar levels for the CIM monoliths was estimated to be between 1.03 and 2.75.  相似文献   

16.
Histidine-tagged lentiviral vectors were separated from crude cell culture supernatant using labscale monolithic adsorbents by immobilized metal affinity chromatography. The capture capacity, concentration factor, purification factor, and elution efficiency of a supermacroporous cryogel monolith were evaluated against the BIA Separations convective interaction media (CIM) disc, which is a commercial macroporous monolith. The morphology of the polymeric cryogel material was characterised by scanning electron microscopy. Iminodiacetic acid was used as the metal chelating ligand in both monoliths and the chelating capacity for metal ions was found to be comparable. The CIM-IDA-Ni(2+) adsorbent had the greatest capture capacity (6.7 x 10(8) IU/ml of adsorbent), concentration factor (1.3-fold), and elution efficiency (69%). Advantages of the cryogel monoliths included rapid, low pressure processing as well low levels of protein and DNA in the final purified vector preparations.  相似文献   

17.
The demand of high-purity plasmid DNA (pDNA) for gene-therapy and genetic vaccination is still increasing. For the large scale production of pharmaceutical grade plasmids generic and economic purification processes are needed. Most of the current processes for pDNA production use at least one chromatography step, which always constitutes as the key-step in the purification sequence. Monolithic chromatographic supports are an alternative to conventional supports due to their excellent mass transfer properties and their high binding capacity for pDNA. Anion-exchange chromatography is the most popular chromatography method for plasmid separation, since polynucleotides are negatively charged independent of the buffer conditions. For the implementation of a monolith-based anion exchange step into a pDNA purification process detailed screening experiments were performed. These studies included supports, ligand-types and ligand-densities and optimization of resolution and productivity. For this purpose model plasmids with a size of 4.3 and 6.9 kilo base pairs (kbp) were used. It could be shown, that up-scaling to the production scale using 800 ml CIM Convective Interaction Media radial flow monoliths is possible under low pressure conditions. CIM DEAE was successfully implemented as intermediate step of the cGMP pDNA manufacturing process. Starting from 2001 fermentation aliquots pilot scale purification runs were performed in order to prove scale-up and to predict further up-scaling to 8 1 tube monolithic columns. The analytical results obtained from these runs confirmed suitability for pharmaceutical applications.  相似文献   

18.
蛋白质糖基化是最常见、最重要的蛋白质翻译后修饰之一,由糖链和多肽链以多种形式共价修饰而成.糖蛋白在生物体内种类繁多,分布广泛,具有重要的生理功能.复杂生物体系中糖蛋白的绝对丰度低,高丰度非糖蛋白质的存在对低丰度糖蛋白质产生夹带、包覆以至掩盖的作用,以现有的技术难以发现并分离鉴定大多数低丰度糖蛋白,已成为当前糖蛋白质组学...  相似文献   

19.
An affinity monolith based on silica and containing immobilized alpha(1)-acid glycoprotein (AGP) was developed and evaluated in terms of its binding, efficiency and selectivity in chiral separations. The results were compared with data obtained for the same protein when used as a chiral stationary phase with HPLC-grade silica particles or monoliths based on a copolymer of glycidyl methacrylate (GMA) and ethylene dimethacrylate (EDMA). The surface coverage of AGP in the silica monolith was 18% higher than that obtained with silica particles and 61% higher than that measured for a GMA/EDMA monolith. The higher surface area of the silica monolith gave materials that contained 1.5- to 3.6-times more immobilized protein per unit volume when compared to silica particles or a GMA/EDMA monolith. The retention, efficiency and resolving power of the AGP silica monolith were evaluated by injecting two chiral analytes onto this column (i.e., R/S-warfarin and R/S-propranolol). In each case, the AGP silica monolith gave higher retention plus better resolution and efficiency than AGP columns containing silica particles or a GMA/EDMA monolith. The AGP silica monolith also gave lower back pressures and separation impedances than these other materials. It was concluded that silica monoliths can be valuable alternatives to silica particles or GMA/EDMA monoliths when used with AGP as a chiral stationary phase.  相似文献   

20.
A convection interaction media (trade name CIM, BIA Separation, Ljubljana, Slovenia) isobutyl monolithic disc was prepared by incubating a CIM epoxy monolithic disc with isobutylamine, and it was then applied to the purification of secondary alcohol dehydrogenase (S-ADH) and primary alcohol oxidase (P-AOD). Both enzymes were adsorbed on this column and eluted with high purity. Thus, S-ADH was purified to an electrophoretically homogeneous state by four column chromatographies using CIM DEAE-8 and CIM C4-8 tube monolithic columns, blue-Sepharose column and CIM isobutyl disc monolithic column. P-AOD was also purified to an electrophoretically homogeneous state by three column chromatographies of CIM DEAE-8 tube, CIM C4-8 tube and CIM isobutyl disc columns.  相似文献   