 共查询到20条相似文献,搜索用时 718 毫秒
1.
Cao X  Pei H  Huo L  Hu G  Ito Y 《Journal of separation science》2011,34(19):2611-2617
An improved type-J counter-current chromatography (CCC) planet centrifuge with two spiral tube columns (volume 2×15 mL, β value 0.3-0.7, tubing 0.8 mm id) was developed and evaluated for its retention ability of four typical different solvent systems including heptane-methanol (1:1, v/v) (A), hexane-ethyl acetate-methanol-water (1:1:1:1, v/v) (B), n-butanol-acetic acid-water (4:1:5, v/v) (C), PEG1000-K(2)HPO(4)-water (12.5:12.5:75, w/w) (D) under eight different operation modes. The results indicated that the spiral tube column could significantly increase the retention of four typical solvent systems compared with a traditional multilayer coil column with similar parameters (volume 35 mL, β value 0.3-0.7, tubing 0.8 mm id). The retention of stationary phase (S(f)) for the less polar system (A) and moderately polar solvent system (B) can be increased by about 10%, and for the polar system (C) and aqueous two-phase system (ATPS) (D) by 30-40%. The preliminary applications of this spiral tube column to the separation of small molecular compounds such as moderately polar theaflavins, polar anthocyanins and dipeptides were successful. Acceptable resolution can be obtained between cytochrome c and myoglobin, lysozyme and myoglobin when it was applied on protein separation; however, it still needs to be improved with regard to its column efficiency.  相似文献   

2.
An important advance in countercurrent chromatography (CCC) carried out in open flow-tubing coils, rotated in planetary centrifuges, is the new design to spread out the tubing in spirals. More spacing between the tubing was found to significantly increase the stationary phase retention, such that now all types of two-phase solvent systems can be used for liquid-liquid partition chromatography in the J-type planetary centrifuges. A spiral tubing support (STS) frame with circular channels was constructed by laser sintering technology into which FEP tubing was placed in 4 spiral loops per layer from the bottom to the top and a cover affixed allowing the tubing to connect to flow-tubing of the planetary centrifuge. The rotor was mounted and run in a P.C. Inc. type instrument. Examples of compounds of molecular weights ranging from <300 to approximately 15,000 were chromatographed in appropriate two-phase solvent systems to assess the capability for separation and purification. A mixture of small molecules including aspirin was completely separated in hexane-ethyl acetate-methanol-water. Synthetic peptides including a very hydrophobic peptide were each purified to a very high purity level in a sec-butanol solvent system. In the STS rotor high stationary phase retention was possible with the aqueous sec-butanol solvent system at a normal flow rate. Finally, the two-phase aqueous polyethylene glycol-potassium phosphate solvent system was applied to separate a protein from a lysate of an Escherichia coli expression system. These experiments demonstrate the versatility of spiral CCC using the STS rotor.  相似文献   

3.
The original spiral tube assembly for high-speed counter-current chromatography (HSCCC) is further improved by a new tube configuration called “flat-twisted tubing” which was made by extruding the tube (1.6 mm I.D.) through a narrow slot followed by twisting along its axis forming about 1 cm twisted screw pitch. This modification interrupts the laminar flow of the mobile phase through the tube and continuously mixes the two phases through the column. The performance of this spiral tube assembly was tested by three types of two-phase solvent systems with different polarities each with a set of suitable test samples such as DNP-amino acids, dipeptides and proteins at the optimal elution modes. In general all these test samples yielded higher resolution with the lower mobile phase than the upper mobile phase. In the most hydrophobic two-phase solvent system composed of hexane–ethyl acetate–methanol–0.1 M hydrochloric acid (1:1:1:1, v/v/v/v), DNP–amino acids were separated with Rs-a (peak resolution based on the same column capacity adjusted for comparison) at 4.40 and 73% of stationary phase retention at a flow rate of 0.5 ml/min with the lower mobile phase. In the polar solvent system composed of 1-butanol–acetic acid–water (4:1:5, v/v/v), dipeptide samples were resolved with Rs-a at 4.06, compared to 2.79 with the cross-pressed tube assembly at 45% stationary phase retention, each at a flow rate of 1 ml/min. Finally in the aqueous–aqueous polymer phase systems composed of polyethylene glycol 1000 – dibasic potassium phosphate each 12.5% (w/w) in water, protein samples were resolved with Rs-a at 2.53 compared to 1.10 with the cross-pressed tube assembly at 52% of stationary phase retention, each at a flow rate of 1 ml/min. These results indicate that the present system substantially improves the partition efficiency with a satisfactory level of stationary phase retention by the lower mobile phase.  相似文献   

4.
Zeng Y  Liu G  Ma Y  Chen X  Ito Y 《Journal of chromatography. A》2011,1218(48):8715-8717
Existing two-phase solvent systems for high-speed countercurrent chromatography cover the separation of hydrophobic to moderately polar compounds, but often fail to provide suitable partition coefficient values for highly polar compounds, such as sulfonic acids, catecholamines and zwitter ions. The present paper introduces a new solvent series which can be applied for the separation of these polar compounds. It is composed of 1-butanol, ethanol, saturated ammonium sulfate and water at various volume ratios and consists of a series of 10 steps which are arranged according to the polarity of the solvent system so that the two-phase solvent system with suitable K values for the target compound(s) can be found in a few steps. Each solvent system gives proper volume ratio and high density difference between the two phases to provide a satisfactory level of retention of the stationary phase in the spiral column assembly. The method is validated by partition coefficient measurement of four typical polar compounds including methyl green (basic dye), tartrazine (sulfonic acid), tyrosine (zwitter ion) and epinephrine (a catecholamine), all of which show low partition coefficient values in the polar 1-butanol-water system. The capability of the method is demonstrated by separation of three catecholamines.  相似文献   

5.
Dual high-speed countercurrent chromatography (dual CCC) literally permits countercurrent flow of two immiscible solvent phases continuously through the coiled column for separation of solutes according to their partition coefficients. Application of this technique has been successfully demonstrated by separation of analytes by gas–liquid and liquid–liquid two-phase systems. However, the method cannot be directly applied to the system with a set of coiled columns connected in series, since the countercurrent process is interrupted at the junction between the columns. However, this problem can be solved by intermittent dual CCC by eluting each phase alternately through the opposite ends of the separation column. This mode of application has an advantage over the conventional dual CCC in that the method can be applied to all types of CCC systems including hydrostatic equilibrium systems such as toroidal coil CCC and centrifugal partition chromatography. Recently, the application of this method to high-speed CCC (hydrodynamic system) has been demonstrated for separation of natural products by Hewitson et al. using a set of conventional multilayer coil separation columns connected in series. Here, we have developed a mathematical model for this intermittent dual CCC system to predict retention time of the analytes, and using a simplified model system the validity of the model is justified by a series of basic studies on both hydrodynamic and hydrostatic CCC systems with a computer-programmed single sliding valve. The present method has been successfully applied to spiral tube assembly high-speed CCC (hydrodynamic system) and toroidal coil CCC (hydrostatic system) for separation of DNP-amino acid samples with two biphasic solvent systems composed of hexane–ethyl acetate–methanol–0.1 M hydrochloric acid (1:1:1:1 and 4:5:4:5, v/v).  相似文献   

6.
Cao X  Hu G  Huo L  Zhu X  Li T  Powell J  Ito Y 《Journal of chromatography. A》2008,1188(2):164-170
A spiral disk assembly composed of five single-channel units was designed for high-speed counter-current chromatography (HSCCC). The retention of different solvent systems ranging from moderately polar to polar organic-aqueous systems to aqueous two-phase systems (ATPs) was investigated under different elution modes. The results indicated that the spiral disk assembly can produce excellent retention of stationary phase for moderately polar organic-aqueous solvent systems, such as chloroform-methanol-water (4:3:2) and hexane-ethyl acetate-methanol-water (1:1:1:1) by pumping lower mobile phase from head (H) to tail (T), and upper mobile phase from tail (T) to head (H) even at a high flow-rate (8 mL/min, Sf>70%), regardless of whether the inlet is at the inner or outer terminal of the channel. This makes it possible for fast analysis of some small molecular compounds. This has been proved in the separation of mixtures of three flavones, including isorhamnetin, kaempferol, and quercetin. The spiral disk assembly can also provide satisfactory retention for polar to ATPS such as 1-butanol-acetic acid-water (4:1:5) (<3 mL/min, Sf>70%), 12.5% poly(ethylene glycol) (PEG) 1000-12.5% K2HPO4-75% water (< or =1 mL/min, Sf>70%) and 4% PEG 8000-5% Dextran T500-91% water (< or =0.5 mL/min, Sf>50%) by pumping lower mobile phase from inner terminal (I) to outer terminal (O), and upper mobile phase from outer terminal (O) to inner terminal (I) at a low flow-rate, while this is not possible with the multilayer coil column. Acceptable resolutions were achieved when it was used for the separation of peptides such as Leu-Tyr and Val-Tyr, and proteins including cytochrome c and myoglobin, lysozyme and myoglobin, and fresh chicken egg-white proteins.  相似文献   

7.
Countercurrent chromatography (CCC) is a separation technique which may be described as a combination of a great number of liquid–liquid distributions of analytes in a two-phase solvent system with liquid chromatography (LC) features. Even optimized CCC separations currently provide a lower number of theoretical plates when compared to LC. For this reason, instrumental advancements are indispensable to, at least partly, overcome this drawback. Recently, we found that improvement of the classic CCC coil, that is using a long hollow tubing, may be achieved by the introduction of tubing crimpings which increase the stationary phase retention. In this study, we systematically investigated the effects of three geometrical parameters (crimping depth, distance between two crimpings as well as partial or complete crimping of the tubing) on the stationary phase retention by a factorial design of experiments approach. Separation efficiency tests were performed with two groups of analytes: fatty acid methyl esters (FAME) in the n-hexane/acetonitrile (HAcn) and alkyl p-hydroxybenzoates in the n-hexane/tert-butylmethylether/methanol/water solvent system. The most narrow crimping distance and the deepest crimping of the tubing were the best configurations in the examined flow rate range.  相似文献   

8.
Partition efficiency of the high-pitch locular multilayer coil was evaluated in countercurrent chromatographic (CCC) separation of proteins with an aqueous-aqueous polymer phase system using the small-scale cross-axis coil planet centrifuge (X-axis CPC) fabricated in our laboratory. The separation column was specially made by high-pitch (ca 5 cm) winding of 1.0 mm I.D., 2.0 mm O.D. locular tubing compressed at 2 cm intervals with a total capacity of 29.5 mL. The protein separation was performed using a set of stable proteins including cytochrome C, myoglobin, and lysozyme with the 12.5% (w/w) polyethylene glycol (PEG) 1000 and 12.5% (w/w) dibasic potassium phosphate system (pH 9.2) under 1000 rpm of column revolution. This high-pitch locular tubing yielded substantially increased stationary phase retention than the normal locular tubing for both lower and upper mobile phases. In order to demonstrate the capability of the high-pitch locular tubing, the purification of collagenase from the crude commercial sample was carried out using an aqueous-aqueous polymer phase system. Using the 16.0% (w/w) PEG 1000 - 6.3% (w/w) dibasic potassium phosphate - 6.3% (w/w) monobasic potassium phosphate system (pH 6.6), collagenase I, II, V and X derived from Clostridium hystolyticum were separated from other proteins and colored small molecular weight compounds present in the crude commercial sample, while collagenase N-2 and S-1 from Streptomyces parvulus subsp. citrinus were eluted with impurities at the solvent front with the upper phase. The collagenase from C. hystolyticum retained its enzymatic activity in the purified fractions. The overall results demonstrated that the high-pitch locular multilayer coil is effectively used for the CCC purification of bioactive compounds without loss of their enzymatic activities.  相似文献   

9.
Abstract

Performance of two countercurrent chromatographic models, high speed countercurrent chromatograph (HSCCC-4000) and analytical toroidal coil centrifuge (TCC), is evaluated in terms of theoretical plate number, resolution factor and separation time to assess their analytical capability. A series of experiments was conducted to investigate the effects of internal diameter and length of the coiled column, and flow rate of the mobile phase on the separation of indole auxins in two-phase solvent systems composed of n-hexane-ethyl acetate-methanol-water at different volume ratios. The three components of indole auxins were completely resolved in 16 min with a HSCCC system equipped with a multilayer coil of a 0.55 mm I.D. PTFE tube with theoretical plates ranging from 1290 to 829. Similar separation was achieved in 24 min with a TCC systems equipped with a 0.3 mm I.D. PTFE tube with theoretical plates ranging from 1811 to 969. It is concluded that both systems have comparable analytical capability at the present stage of development.  相似文献   

10.
Type-I coil planet centrifuge produces a uniformly circulating centrifugal force field to produce vortex motion of two immiscible solvent phases in a cylindrical cavity of the separation column to perform efficient countercurrent chromatography. The partition efficiency obtained from the original vortex column was substantially improved by threading the cylindrical cavity to increase the area of mass transfer between the two phases. Partition efficiency of the threaded column was evaluated by three different two-phase solvent systems with a broad range of hydrophobicity each with a set of suitable test samples. Overall results of the present studies indicated that the threaded cylindrical column substantially improves the partition efficiency in terms of theoretical plate number, peak resolution, and height equivalent of one theoretical plate. The results also indicated that higher peak resolution is produced by eluting either the upper phase in the head to tail direction or the lower phase in the reversed direction. When there is a choice in the mobile phase, a better separation is achieved by using the less viscous phase as the mobile phase. Since the present system gives extremely low column pressure, it may be a potential alternative to the conventional type-J HSCCC system for a large-scale preparative separation.  相似文献   

11.
Centrifugal precipitation chromatography and a high-speed counter-current chromatography system equipped with a spiral tubing support rotor (spHSCCC) were successfully applied for the identification and isolation of carotenoid cleavage-like enzymes from Enteromorpha compressa (L.) Nees. This is the first study separating active enzymes from a complex natural matrix by spHSCCC. The target enzymes were identified after fractionation of the proteins in an acetone Tris-buffer gradient by centrifugal precipitation chromatography. Also, an aqueous two-phase solvent system consisting of PEG 1000 and mono- and dibasic potassium phosphate was used for the isolation of the enzymes by spHSCCC. The purified fractions contained two proteins of 65 and 72 kDa, respectively. The enzymes could cleave β-carotene and β-apo-8'-carotenal to produce β-ionone.  相似文献   

12.
A rotary-seal-free planetary centrifuge holds a separation column which consists of multiple partition units (ca. 200) connected in series with transfer tubes. In the cavity of each partition unit the transfer tube extends to form a mixer which vibrates to stir the contents under an oscillating force field generated by the planetary motion of the centrifuge. Consequently, solutes locally introduced at the inlet of the column are subjected to an efficient partition process in each partition unit and separated according to their partition coefficients. The mixer tube equipped with a flexible silicone rubber joint was found to produce excellent results for partition with viscous polymer phase systems. The capability of the method was demonstrated on separation of cytochrome c and lysozyme using a PEG-aqueous dibasic potassium phosphate-aqueous two-phase solvent system.  相似文献   

13.
Apple procyanidins were separated by high-speed counter-current chromatography using a type-J multilayer coil planet centrifuge. Several two-phase solvent systems with a wide range of hydrophobicities from a non-polar hexane system to polar n-butanol systems were evaluated their performance in terms of the partition coefficient and the retention of the phase. The best separation of procyanidins B and C was achieved with a two-phase solvent system composed of n-butanol-methyl tert.-butyl ether-acetonitrile-0.1% trifluoroacetic acid (2:4:3:8) using the lower phase as a mobile at a flow-rate of 1.0 ml/min.  相似文献   

14.
An ionic liquid/aqueous two-phase system based on the hydrophilic ionic liquid 1-butyl-3-methylimidazolium chloride (BmimCl) and K(2)HPO(4) has been employed for direct extraction of proteins from human body fluids for the first time. Proteins present at low levels were quantitatively extracted into the BmimCl-rich upper phase with a distribution ratio of about 10 between the upper and lower phase and an enrichment factor of 5. Addition of an appropriate amount of K(2)HPO(4) to the separated upper phase results in a further phase separation, giving rise to an improved enrichment factor of 20. FTIR and UV spectroscopy demonstrated that no chemical (bonding) interactions between the ionic liquid and the protein functional groups were identifiable, while no alterations of the natural properties of the proteins were observed. The partitioning of proteins in the two-phase system was assumed to have been facilitated by the electrostatic potential difference between the coexisting phases, as well as by salting out effects. The system could be applied successfully for the quantification of proteins in human urine after on-line phase separation in a flow system. The use of an ionic liquid, as a green solvent, offers clear advantages over traditional liquid-liquid extractions, in which the use of toxic organic solvents is unavoidable.  相似文献   

15.
A novel system for performing high-speed counter-current chromatography has been developed for separation of biopolymers using polymer phase systems. The spiral disk assembly consisting of eight units, each equipped with over 300 mixer-settler sets, was constructed and performance evaluated in terms of retention of the stationary phase and separation efficiency. A series of experiments was performed with a polymer phase system composed of polyethylene glycol 1000 (12.5%, w/w) and dibasic potassium phosphate (12.5%, w/w) using two stable protein samples of myoglobin and lysozyme at various experimental conditions of flow rates and revolution speeds. The best results were obtained with revolution speeds of 800-1000rpm at flow rates of 0.25-0.5ml/min where the partition efficiency of several 100 theoretical plates was achieved with over 50% stationary phase retention.  相似文献   

16.
Abstract

Salt in polyethylene glycol (PEG)/salt aqueous two-phase systems was excluded by PEG and concentrated in the solvent volume available for dissolution of salt (PEG-free solvent). The concentration of salt in the PEG-free solvent of the PEG-rich phase was the same as that at the critical point regardless of the compositions of the PEG/salt two-phase systems. This explained that the phase separation of PEG/salt two-phase systems occurs when the concentration of salt in the PEG-free solvent reaches its solubility limit. The concentration of salt required in the PEG-free solvent for the phase separation was lower with higher molecular weight of PEG. The solubility of salt in the PEG-free solvent decreased with increases in the molal surface tension increment of salt. The solubility limit of salt in the PEG-free solvent was 0.93 M for ammonium sulfate, 0.77 M for potassium phosphate, 0.75 M for sodium tartrate, 0.67 M for sodium phosphate, and 0.53 M for potassium citrate.  相似文献   

17.
Counter-current chromatographic separation of proteins was performed using a rotary-seal-free nonsynchronous coil planet centrifuge (CPC) fabricated in our laboratory. This apparatus has a unique feature that allows a freely adjustable rotational rate of the coiled separation column at a given revolution speed. The separation was performed using a set of stable proteins including cytochrome c, myoglobin and lysozyme with two different types of aqueous-aqueous polymer phase systems, i.e., PEG (polyethylene glycol) 1000-dibasic potassium phosphate, and PEG 8000-dextran T500 in 5 mM potassium phosphate buffer. Using a set of multilayer coiled columns prepared from 0.8 mm I.D. PTFE tubing with different volumes (11, 24, 39 ml), the effect of the column capacity on the partition efficiency was investigated under a given set of experimental conditions. Among these experiments, the best separation of proteins was attained using the 39 ml capacity column with a 12.5% (w/w) PEG 1000-12.5% (w/w) dibasic potassium phosphate system at 10 rpm of coil rotation under 800 rpm. With lower phase mobile at 0.2 ml/min in the head-to-tail elution, the resolution between cytochrome c and myoglobin was 1.6 and that between myoglobin and lysozyme, 1.9. With upper phase mobile in the head-to-tail elution, the resolution between lysozyme and myoglobin peaks was 1.5. In these two separations, the stationary phase retention was 35.0 and 33.3%, respectively. Further studies were carried out using a pair of eccentric coil assemblies with 0.8 mm I.D. PTFE tubing at a total capacity of 20 ml. A comparable resolution was obtained using both lower and upper phases as a mobile phase in a head-to-tail elution. The results of our studies demonstrate that the nonsynchronous CPC is useful for protein separation with aqueous-aqueous polymer phase systems.  相似文献   

18.
油酸/三乙醇胺/液体石蜡水体系层状润滑性能   总被引:32,自引:0,他引:32  
层状液晶;油酸/三乙醇胺/液体石蜡水体系层状润滑性能  相似文献   

19.
The effect of Coriolis force on the counter-current chromatographic separation was studied using centrifugal partition chromatography (CPC) with four different two-phase solvent systems including n-hexane-acetonitrile (ACN); tert-butyl methyl ether (MtBE)-aqueous 0.1% trifluoroacetic acid (TFA) (1:1); MtBE-ACN-aqueous 0.1% TFA (2:2:3); and 12.5% (w/w) polyethylene glycol (PEG) 1000-12.5% (w/w) dibasic potassium phosphate. Each separation was performed by eluting either the upper phase in the ascending mode or the lower phase in the descending mode, each in clockwise (CW) and counterclockwise column rotation. Better partition efficiencies were attained by the CW rotation in both mobile phases in all the two-phase solvent systems examined. The mathematical analysis also revealed the Coriolis force works favorably under the CW column rotation for both mobile phases. The overall results demonstrated that the Coriolis force produces substantial effects on CPC separation in both organic-aqueous and aqueous-aqueous two-phase systems.  相似文献   

20.
A simple and rapid dispersive liquid-liquid microextraction (DLLME) technique coupled with gas chromatography-flame ionization detection (GC-FID) and gas chromatography-mass spectrometry (GC-MS) was developed for the extraction, preconcentration, and analysis of triazole pesticides (penconazole, hexaconazole, tebuconazole, triticonazole, and difenoconazole) in cow milk samples. Initially to 5 mL milk sample, NaCl and acetonitrile were added as salting-out agent and extraction solvent, respectively. After manual shaking, the mixture was centrifuged. In the presence of sodium chloride, a two-phase system was formed: upper phase, acetonitrile containing triazole pesticides and lower phase, aqueous phase containing soluble compounds and the precipitated proteins. After the extraction of pesticides from milk, a portion of supernatant phase (acetonitrile) was removed, mixed with chloroform at microliter level and rapidly injected by syringe into 5 mL distilled water. In this process, triazole pesticides were extracted into fine droplets of chloroform (as extraction solvent). After centrifugation, the fine droplets of chloroform were sedimented in bottom of the conical test tube. Finally, GC-FID and GC-MS were used for the separation and determination of analytes in the sedimented phase. Some important parameters like type of solvent for extraction of pesticides from milk, salt amount, the volume of extraction solvent, etc., which affect the extraction efficiency, were completely studied. Under the optimum conditions, enrichment factors were in the range of 156-380. The linear ranges of calibration curves were wide and limits of detection (LODs) and limits of quantification (LOQs) were between 4-58 and 13-180 μg/L, respectively. This method is very simple and rapid, requiring <15 min for sample preparation.  相似文献   