共查询到20条相似文献,搜索用时 15 毫秒
1.
The processing of sexual assault kits (SAKs) relies on the genetic analysis of material extracted from swabs collected from the assault victim. A vital step in producing an identifiable DNA profile of the perpetrator is the effective separation of perpetrator (sperm) and victim (epithelial) DNA that have been isolated from the collected evidence. We report the use of capillary zone electrophoresis for the separation of intact sperm from whole and lysed epithelial cells in SAKs. The separated components are deposited into wells of a microtiter plate using a computer-controlled fraction collector, and quantitative PCR is used to verify the collection of sperm cells by targeted amplification of male DNA. We present results from simulated sexual assault samples that have been aged for up to 18 months, as well as vaginal swabs from authentic forensic kits. Components extracted from the vaginal swabs from the SAK comigrated with an aged semen sample at 6.25 ± 0.25 min. Epithelial cells migrated from 10-12 min, producing baseline resolution of the components. Sperm cells were collected in a microtiter plate for downstream analysis. 相似文献
2.
Summary Capillary zone electrophoresis (CZE) has been coupled with mass spectrometry to enable the identification of mineral and organometallic
compounds of arsenic in speciation studies. The electrophoretic effluent was introduced through a concentric interface into
the mass spectrometer. Make-up liquid was added to enable electric contact at the outlet of the separation capillary and to
assist the electronebulization process. After ionization, the ions were analyzed and quantified with an ion-trap detector.
Optimization of the coupling conditions (geometry of the concentric interface, composition and flow rate of the sheath liquid,
electronebulization and detection conditions) is described. The results show that the geometry of the concentric interface
and the positioning of the outlet of the separation capillary have a critical effect on stability and sensitivity.
Programming the electronebulization and detection conditions throughout the analysis enabled identification and quantification
of the seven arsenic compounds of interest (neutral, and positively or negatively charged species) in less than 20 min at
the ppm level. Limits of detection ranged from 0.5 to 3.3 mg L−1, corresponding to amounts injected ranging from 15 to 60 pg. The linear dependence of mass spectrometric response on arsenic
concentration was verified for concentrations ranging from 5 to 200 mgL−1. For the two positively charged species, arsenobetaine and arsenocholine, an on-line preconcentration technique (field-amplified
sample injection) enabled reduction of the detection limits by approximately one order of magnitude to 110 and 160 μgL−1, respectively. 相似文献
3.
The applicability of CZE with mass spectrometric detection for the determination of four chlorine species, namely chloride and three stable chlorine oxyanions, was studied. The main aspects of the proper selection of BGE and sheath liquid for the CE‐MS determinations of anions with high mobility were demonstrated, pointing out the importance of pH and the mobility of the anion in the BGE. The possibility of using uncoated fused silica capillary and common electrolytes for the separation was shown and the advantage of using extra pressure at the inlet capillary end was also presented. The linear range was found to be 1–100 µg/mL for ClO3? and ClO4?, 5–500 µg/mL for ClO2?, and 25–500 µg/mL for Cl?, but the sensitivity can be greatly improved if larger sample volume is injected and electrostacking effect is utilized. The LOD for ClO3? in drinking water was 6 ng/mL, when very large sample volume was injected (10 000 mbar·s was applied). 相似文献
4.
5.
Double‐layer poly(vinyl alcohol)‐coated capillary for highly sensitive and stable capillary electrophoresis and capillary electrophoresis with mass spectrometry glycan analysis 下载免费PDF全文
Yi‐Wei Zhang Ming‐Zhe Zhao Jing‐Xin Liu Ying‐Lin Zhou Xin‐Xiang Zhang 《Journal of separation science》2015,38(3):475-482
Glycosylation plays an important role in protein conformations and functions as well as many biological activities. Capillary electrophoresis combined with various detection methods provided remarkable developments for high‐sensitivity glycan profiling. The coating of the capillary is needed for highly polar molecules from complex biosamples. A poly(vinyl alcohol)‐coated capillary is commonly utilized in the capillary electrophoresis separation of saccharides sample due to the high‐hydrophilicity properties. A modified facile coating workflow was carried out to acquire a novel multiple‐layer poly(vinyl alcohol)‐coated capillary for highly sensitive and stable analysis of glycans. The migration time fluctuation was used as index in the optimization of layers and a double layer was finally chosen, considering both the effects and simplicity in fabrication. With migration time relative standard deviation less than 1% and theoretical plates kept stable during 100 consecutive separations, the method was presented to be suitable for the analysis of glycosylation with wide linear dynamic range and good reproducibility. The glycan profiling of enzymatically released N‐glycans from human serum was obtained by the presented capillary electrophoresis method combined with mass spectrometry detection with acceptable results. 相似文献
6.
Capillary electrophoresis (CE) was compared with reversed-phase liquid chromatography for its ability to separate native and deamidated peptides. CE is shown to provide superior resolution of these peptides due to its charge-based separation mechanism. Fraction collection performed using a standard CE instrument equipped with a 96-well plate permits subsequent characterization by nanospray mass spectrometric (MS) analysis. Additional in-depth analysis by MS/MS is able to provide the location of the deamidation site based on y-ion mass shifts of 1 Da. 相似文献
7.
In this study, positively charged alkylaminosilyl monomers were used to modify the inner surface of fused silica capillaries, which subsequently were employed in capillary electrophoresis (CE) and capillary electrochromatography (CEC). The obtained surfaces yield a reversed electroosmotic flow (EOF) and have varying carbon chain lengths, that interact with the analytes and give chromatographic retention. The coating procedure is very simple and fast. The performance of the modified capillaries was evaluated regarding pH influence on EOF and chromatographic interactions. The experiments were conducted with UV and mass spectrometry (MS) and applied to the separation of various neuropeptides. The derivatized surfaces showed a linear (R(2) approximately 0.99) pH dependence with isoelectric points (pI) at 8.6-8.8. Rapid separations of peptide standards and a protein digest with efficiencies as high as 5 x 10(5) plates/m were performed. 相似文献
8.
Chuzo Fujimoto Yoshie Muramatsu Misa Suzuki Kiyokatsu Jinno 《Journal of separation science》1991,14(3):178-180
A simple method is described which enables solutes to be collected at an electrically isolated exit after they have been separated by a free solution capillary electrophoretic system. The method is illustrated by the separation of dansyl amino acids using multiple separation capillaries. 相似文献
9.
Desiderio C De Rossi A Inzitari R Mancinelli A Rossetti DV Castagnola M Messana I 《Analytical and bioanalytical chemistry》2008,390(6):1637-1644
A capillary electrophoresis (CE) method coupled to electrospray ionization ion trap tandem mass spectrometry (ESI-IT-MS/MS)
is described for the rapid analysis of carnitine, acetylcarnitine, and propionylcarnitine in human plasma. Optimization of
the procedure was achieved by a reduced sample pretreatment and after examining several physicochemical parameters that influence
both the CE separation and the MS analytes detection. The analysis of total carnitine in human plasma after hydrolysis of
short-chain metabolites is also shown. The analysis of carnitine and metabolites was obtained in less than 10 min using a
200 mM ammonium formate buffer, pH 2.5, with high sensitivity and specificity using the MS detection in product ion scan mode.
The method was tested for quantitative recovery using dialyzed human plasma as matrix and showed linearity in the concentrations
ranges 20–160, 1–32, and 0.25–8 μM for carnitine, acetylcarnitine, and propionylcarnitine with (squared) correlation coefficients
of 0.9984, 0.9995, and 0.9991, respectively. The intraday and intermediate analysis repeatability and accuracy are within
15% of relative standard deviation (RSD) at low, medium, and high concentration and within/or slight exceeding 20% at the
lower limit of quantitation (LLOQ). The method is sensitive for determining carnitine and its metabolites in human plasma
with high specificity. 相似文献
10.
Steven A. Hofstadler Joanne C. Severs Richard D. Smith Frank D. Swanek Andrew G. Ewing 《Journal of separation science》1996,19(11):617-621
We describe the current state of the on-line combination of capillary electrophoresis (CE) electrospray ionization (ESI) Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS), and discuss aspects of the FTICR technique relevant to its use as a detection scheme for on-line separations. Aspects including sensitivity, mass resolution, duty cycle, and tandem mass spectrometric capabilities are discussed in the context of online separations with examples from the authors' laboratory. 相似文献
11.
Summary Aspects of cracking and joining capillaries have been investigated. Capillary coupling was achieved using various methods. The most successful used hydrofluoric acid-etched capillaries to form male and female ends which were then joined together. This type of joint was used to connect sections of capillary of similar and different internal diameters with minimal loss in resolution, peak width and number of theoretical plates. (Uridine and hypoxanthine was used as a test mixture). For hypoxanthine on a 50 m/50 m etched joined capillary 10 cm from the detector window the number of theoretical plates was 96.6% of that for hypoxanthine on an unbroken capillary. Following the relative success of capillary joining, a coupled capillary flowcell (50 m/200 m) was produced and evaluated. 相似文献
12.
Wolfgang W. Buchberger Ingrid HattingerMarkus Himmelsbach 《Journal of chromatography. A》2009,1216(1):113-118
The polycondensation of guanidine hydrochloride and 2,2′-(ethylenedioxy)bis(ethylamine) leads to various types of oligomeric guanidines exhibiting a broad spectrum of biocidal activities. In the present work a reversed-phase high-performance liquid chromatographic method with a gradient consisting of aqueous 0.1% trifluoroacetic acid and acetonitrile as mobile phase has been developed to separate these oligoguanidines according to type and chain length. The combination with electrospray mass spectrometry allowed the identification of the various compounds. By this technique, some structures already suggested in the literature could be confirmed, and several additional oligoguanidines not yet reported could be identified. As a complementary technique, capillary zone electrophoresis was investigated. Best results were obtained with carrier electrolytes consisting of phosphoric acid in water/acetonitrile mixtures. Although the number of peaks that could be separated by the electrophoretic method was considerably lower than in case of the chromatographic method, capillary electrophoresis in combination with UV detection at 195 nm may still be a fast method suitable for quantitation of some of the major compounds and for monitoring the reaction rate during the polycondensation reaction. 相似文献
13.
Alexander Stolz Kevin Jooß Oliver Hcker Jennifer Rmer Johannes Schlecht Christian Neusüß 《Electrophoresis》2019,40(1):79-112
Capillary electrophoresis (CE) offers fast and high‐resolution separation of charged analytes from small injection volumes. Coupled to mass spectrometry (MS), it represents a powerful analytical technique providing (exact) mass information and enables molecular characterization based on fragmentation. Although hyphenation of CE and MS is not straightforward, much emphasis has been placed on enabling efficient ionization and user‐friendly coupling. Though several interfaces are now commercially available, research on more efficient and robust interfacing with nano‐electrospray ionization (ESI), matrix‐assisted laser desorption/ionization (MALDI) and inductively coupled plasma mass spectrometry (ICP) continues with considerable results. At the same time, CE‐MS has been used in many fields, predominantly for the analysis of proteins, peptides and metabolites. This review belongs to a series of regularly published articles, summarizing 248 articles covering the time between June 2016 and May 2018. Latest developments on hyphenation of CE with MS as well as instrumental developments such as two‐dimensional separation systems with MS detection are mentioned. Furthermore, applications of various CE‐modes including capillary zone electrophoresis (CZE), nonaqueous capillary electrophoresis (NACE), capillary gel electrophoresis (CGE) and capillary isoelectric focusing (CIEF) coupled to MS in biological, pharmaceutical and environmental research are summarized. 相似文献
14.
Several semiempirical models for peptide electrophoretic mobility have been tested for capillary electrophoresis (CE) separation with a positively charged capillary using on-line CE combined with electrospray ionization-mass spectrometry (ESI-MS). In the current system with pH 2.7, the expression q/M(0.56) provided the best correlation with the electrophoretic mobility in the analysis of a set of 18 standard samples, where q is the calculated net charge and M is the molecular weight. The peptides resulting from various digests of horse heart myoglobin or bovine hemoglobin were used to demonstrate the validity of this correlation. Post-translationally modified peptides from tryptic digest of human myelin basic protein were also investigated and were found to provide excellent correlation with the linear plot when the total charge of the peptide was correctly calculated. If the total charge was not properly calculated then the post-translationally modified peptides fell off the linear plot. Using this method five arginine residues (residues 5, 49, 54, 97 and 130) were found to be partially citrullinated, four glutamine residues (residues 8, 103, 121 and 147) were found to be partially deamidated and both methionines at residues 21 and 167 were found to be partially oxidized. Three peptides were found with phosphorylation; TPPPSQGK (residue 98 to 105), FSWGAEGQR (residue 114 to 122), and SGSPMAR (residue 163 to 169) and Arginine at 107 was found to be partially monomethylated or dimethylated. The method may provide an excellent means of identifying the presence of peptides with post-translational modifications in conjunction with MS. 相似文献
15.
Summary Intensive work has been invested in recent years to evaluate the performance of capillary electrophoresis (CE) in forensic
analysis. Tremendous progress has also been achieved in interfacing CE to sensitive and specific detection systems such as
the mass spectrometer (MS). We have recently developed an electrospray time-of-flight mass spectrometer (ESI-TOFMS) for use
as a detector for fast and efficient liquid phase separations. In the present paper we investigated ESI-TOFMS for the analysis
of an opium powder. Both continuous infusion and CE were studied for direct sample introduction into the TOFMS and mixture
separation, respectively. CEMS analysis of the opium was performed in a citrate buffer, using aqueous or mixed aqueous/organic
eluents. Low fmol detection was achieved. 相似文献
16.
《Electrophoresis》2018,39(16):2069-2082
High‐resolution capillary zone electrophoresis – mass spectrometry (CZE‐MS) has been of increasing interest for the analysis of biopharmaceuticals. In this work, a combination of middle‐down and intact CZE‐MS analyses has been implemented for the characterization of a biotherapeutic monoclonal antibody (mAb) with a variety of post‐translational modifications (PTMs) and glycosylation structures. Middle‐down and intact CZE separations were performed in an acidified methanol‐water background electrolyte on a capillary with a positively charged coating (M7C4I) coupled to an Orbitrap mass spectrometer using a commercial sheathless interface (CESI). Middle‐down analysis of the IdeS‐digested mAb provided characterization of PTMs of digestion fragments. High resolution CZE enabled separation of charge variants corresponding to 2X‐deamidated, 1X‐deamidated, and non‐deamidated forms at baseline resolution. In the course of the middle‐down CZE‐MS analysis, separation of glycoforms of the FC/2 fragment was accomplished due to hydrodynamic volume differences. Several identified PTMs were confirmed by CZE‐MS2. Incorporation of TCEP‐HCl reducing agent in the sample solvent resulted in successful analysis of reduced forms without the need for alkylation. CZE‐MS studies on the intact mAb under denaturing conditions enabled baseline separation of the 2X‐glycosylated, 1X‐glycosylated, and aglycosylated populations as a result of hydrodynamic volume differences. The presence of a trace quantity of dissociated light chain was also detected in the intact protein analysis. Characterization of the mAb under native conditions verified identifications achieved via intact analysis and allowed for quantitative confirmation of proteoforms. Analysis of mAbs using CZE‐MS represents a complementary approach to the more conventional liquid‐chromatography – mass spectrometry‐based approaches. 相似文献
17.
With benign prostatic hyperplasia (BPH) being a major health problem in ageing men, alternative therapeutic approaches (e.g., with phytopharmaceuticals) are of great interest. Based on pharmacological evidences, one of the most promising options in that respect are the lectins found in Urtica dioica (stinging nettle) roots. In this study the qualitative and quantitative analysis of individual isolectins in U. dioica extracts is described, which is the first report on using capillary electrophoresis (CE) for the analysis of lectins in plant material at all. By utilizing a 200 mM sodium acetate buffer (pH 3.75) a baseline separation and determination of four closely related isolectins was feasible within 20 min in the aqueous plant extracts. The individual compounds were identified based on reference compounds as well as data obtained from CE-mass spectrometry (MS) experiments. After modifying the optimized CE conditions to 100 mM ammonium formate buffer with pH 3.75 and a voltage of 15 kV, the isolectins were clearly assignable in positive electrospray ionization (ESI) mode. The quantitative results obtained by CE (the total lectin content varied from 0 to 0.42% in the samples) were accurate (recovery rates of spiked samples between 92.5 and 96.2%), precise (relative standard deviation < 5%) and in good agreement to those obtained by High-performance liquid chromatography (HPLC). As for peak resolution, assignable compounds and required separation time the newly developed CE method was clearly advantageous over the determination achieved by LC. 相似文献
18.
Three standardised, capillary zone electrophoresis-electrospray ionisation mass spectrometry (CZE-ESI-MS) methods were developed for the analysis of six drug candidates and their respective process-related impurities comprising a total of 22 analytes with a range of functional groups and lipophilicities. The selected background electrolyte conditions were found to be: 60/40 v/v 10 mM ammonium formate pH 3.5/organic, 60/40 v/v 10 mM ammonium acetate pH 7.0/organic and 10 mM piperidine, pH 10.5, where the organic solvent is 50/50 v/v methanol/acetonitrile. The coaxial sheath flow consisted of either 0.1% v/v formic acid in 50/50 v/v methanol/water, or 10 mM ammonium acetate in 50/50 v/v methanol/water, depending on the mixture being analysed. Factor analysis and informational theory were used to quantify the orthogonality of the methods and predict their complementarities. The three selected CZE-ESI-MS methods allowed the identification of 21 out of 22 of all the drug candidates and their process-related impurities and provided orthogonality with four established high-performance liquid chromatography-mass spectrometry (HPLC-MS) methods. These methodologies therefore form the basis of a generic approach to impurity profiling of pharmaceutical drug candidates and can be applied with little or no analytical method development, thereby offering significant resource and time savings. 相似文献
19.
A method using capillary electrophoresis-mass spectrometry (CE-MS) was developed for the structural elucidation of bupivacaine and metabolites in rat urine. Prior to CE-MS analysis, solid-phase extraction (SPE) was used for sample cleanup and preconcentration purposes. Exact mass and tandem mass spectrometric (MS/MS) experiments were performed to obtain structural information about the unknown metabolites. Two instruments with different mass analyzers were used for mass spectrometric detection. A quadrupole time-of-flight (Q-TOF) and a magnetic sector hybrid instrument were coupled to CE and used for the analysis of urine extracts. Hydroxybupivacaine as well as five other isomerically different metabolites were detected including methoxylated bupivacaine. 相似文献
20.
Separation of seven organic and inorganic arsenical species, i.e., inorganic arsenite (As III) and arsenate (As V), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenobetaine (AsBet), arsenocholine (AsCh) and p-arsanilic acid (pAs) was carried out by capillary electrophoresis (CE) equipped with one of two different optical path cells, i.e., either the standard detection interface (SDI) or the high sensitive detection cell (HSDC). Separation, identification and quantification of the As species were performed by means of a capillary silica column with an alkaline borate buffer at pH 9.3 and direct UV detection at 192 nm. This methodological approach was tested with the abovementioned types of cells, and the results of the two modes were compared. In both cases, good separation was obtained, and also, repeatability in terms of migration times and peak areas was rather satisfactory. With regard to sensitivity, the HSDC allowed peak areas to be obtained, which were ca. 50 times greater than those afforded by the former cell. This also led to a substantial improvement in the limits of detection (LoDs); by a factor of 9 in the case of AsCh. 相似文献