首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Cyanex 923 has been proposed as a sensitive analytical reagent for the direct extractive spectrophotometric determination of cobalt(II). Cobalt(II) forms a blue-colored complex with Cyanex 923 in the organic phase. The maximum absorbance of the complex is measured at 635 nm. Beer's law was obeyed in the range 58.9 - 589.0 microg of cobalt. The molar absorptivitiy and Sandell's sensitivity of the complex was calculated to be 6.79 x 10920 l mol(-1) cm(-1) and 0.088 microg cm(-2), respectively. The nature of the extracted species was found to be Co(SCN)2 x 2S. An excellent linearity with a correlation coefficient value of 0.999 was obtained for the Co(II)-Cyanex 923 complex. Stability and regeneration of the reagent (Cyanex 923) for reuse is the main advantage of the present method. The method was successfully applied to the determination of cobalt in synthetic mixtures and pharmaceutical samples was found to give values close to the actual ones. Standard alloy samples, such as high-speed tool BCS 484 and 485, have been tested for the determination of cobalt for the purpose of validating the present method. The results of the proposed method are comparable with atomic absorption spectrometry and were found to be in good agreement.  相似文献   

2.
A rapid flotation method for separation and enrichment of ultra trace amounts of copper(II), cadmium(II), nickel(II) and cobalt(II) ions from water samples is established. At pH 6.5 and with sodium dodecylsulfate used as a foaming reagent, Cu2+, Cd2+, Ni2+ and Co2+ were separated simultaneously with 2-aminocyclopentene-1-dithiocarboxylic acid (ACDA) added to 1 l of aqueous solution. The proposed procedure of preconcentration is applied prior to the determination of these four analytes using inductivity coupled plasma-atomic emission spectrometry (ICP-AES). The effects of pH, concentration of ACDA, applicability of different surfactants and foreign ions on the separation efficiency were investigated. The preconcentration factor of the method is 1000 and the detection limits of copper(II), cadmium(II), nickel(II) and cobalt(II) ions are 0.078, 0.075, 0.072 and 0.080 ng ml(-1), respectively.  相似文献   

3.
We report on a new method for the dispersive liquid-liquid microextraction of Cd(II), Co(II), Pb(II) and Ni (II) from water samples prior to their simultaneous determination by inductively coupled plasma optical emission spectrometry (ICP-OES). The procedure is based on the injection of a ternary solvent system composed of appropriate quantities of extraction solvent (trichloroethylene), dispersive solvent (ethanol), and the chelating reagent 2-(2′-benzothiazolylazo)-p-cresol into the sample solution. The solution turns turbid immediately after injection, and the analytes are extracted into the droplets of the organic phase which was dried and dissolved in a mixture of Triton X-114, nitric acid, and ethanol. The metal ions in this mixture were quantified by ICP-OES. The detection limits under optimized conditions are 0.2, 0.3, 0.2 and 0.7?μg?L?1 for Cd(II), Co(II), Pb(II) and Ni(II), respectively. The enrichment factors were also calculated for Cd (13), Co (11), Pb (11) and Ni (8). The procedure was applied to the determination of cadmium, cobalt, lead and nickel in certified reference material (waterway sediment) and water samples.
Figure
A new method for the dispersive liquid-liquid microextraction of Cd(II), Co(II), Pb(II) and Ni(II) from water samples prior to their simultaneous determination by inductively coupled plasma optical emission spectrometry (ICP OES) is presented. The procedure was applied to the determination of elements in samples of river and lake water.  相似文献   

4.
《Analytical letters》2012,45(9):2085-2094
Abstract

Principal component‐artificial neural network (PC‐ANN) and principal component‐wavelet neural network (PC‐WNN) are applied for simultaneous determination of iron(II), nickel(II), and cobalt(II). A simple and selective spectrophotometric method for simultaneous determination of iron(II), nickel(II), and cobalt(II) based on formation of their complexes with 1‐(2‐pyridylazo)‐2‐naphtol (PAN) in micellar media is described. Although the complexes of Fe(II), Ni(II), and Co(II) with reagent show a spectral overlap, they have been simultaneously determined by PC‐ANN and PC‐WNN. The results obtained by the two methods were compared and it was shown that in PC‐WNN, the convergence speed was faster and the root mean square error of prediction set was also smaller than PC‐ANN. Interference effects of common anions and cations were studied and the proposed method was also applied satisfactorily to the determination of Fe(II), Ni(II) and Co(II) in synthetic samples.  相似文献   

5.
Carvalho MS  Fraga IC  Neto KC  Silva Filho EQ 《Talanta》1996,43(10):1675-1680
The present work describes a selective, rapid and economical method for the determination of cobalt using the 2-(2-benzothiazolylazo)-p-cresol (BTAC) as a spectrophotometric reagent associated with a solid extraction on polyurethane foam. The BTAC reacts with Co(II) in the presence of Triton-X100 surfactant forming a green complex with maximum absorption at 615 nm. The reaction is used for cobalt determination within a pH range of 6.50-7.50, with an apparent molar absorptivity of 1.62 x 10(4) L mol(-1) cm(-1). Beer's Law is obeyed for a concentration of at least 1.60 microg ml(-1). A selective procedure is proposed for cobalt determination in the presence of Fe(II), Hg(II), Zn(II) and Cu(II) up to milligram levels using masking agents. Polyurethane foam is used for the preconcentration and separation of cobalt from thiocyanate media and this procedure is applied to its determination in nickel salts and steel alloys.  相似文献   

6.
A sensitive solid-phase extraction technique (SPE) for the enrichment of Fe(III), Co(II), Mn(II) and Cr(III) prior to atomic absorption spectrometric analysis is described. Escherichia coli immobilized on Amberlite XAD-4 was used as a solid-phase extractor. The effects of the pH, amount of solid-phase, eluent type and volume of the sample solution on the recovery of the metal ions were investigated. The effect of diverse ions was also investigated. The recoveries of Fe(III), Co(II), Mn(II) and Cr(III) under the optimum conditions were found to be 99 +/- 2, 99 +/- 3, 98 +/- 2, 98 +/- 3%, respectively, at the 95% confidence level. The detection limits of the metal ions were found as to be 2.4, 3.8, 1.3 and 1.7 ng ml(-1) for Fe(II), Co(II), Mn(II) and Cr(III) respectively, by applying a preconcentration factor of 25. The proposed enrichment method was applied to the determination of analytes in Atatürk Dam water samples, and alloy samples (RSD < 5%). The accuracy of the method was verified on certified alloy samples (NBS SRM 85b and NBS SRM 59a). The analytes were determined with a relative error lower than 5% in water and alloy samples.  相似文献   

7.
A very simple and selective spectrophotometric method for simultaneous determination of iron(II), nickel(II) and cobalt(II) based on formation of their complexes with 1-(2-pyridylazo)-2-naphtol (PAN) in micellar media is described. Although the complexes of Fe(II), Ni(II) and Co(II) with reagent show a spectral overlap, they have been simultaneously determined by partial least squares (PLS) with and without preprocessing step using direct orthogonal signal correction (DOSC). The linear range was 0.30-4.50 μg ml−1 for Co(II), 0.20-3.00 μg ml−1 for Ni(II) and 0.30-5.00 μg ml−1 for Fe(II). The results obtained by the PLS and DOSC-PLS were statistically compared. Interference effects of common anions and cations were studied and the proposed method was also applied satisfactorily to the determination of Fe(II), Ni(II) and Co(II) in synthetic samples.  相似文献   

8.
The reagent bis(isovalerylacetone)ethylenediimine(H2IVA2en) has been examined for HPLC separation and UV determination of cobalt, copper, iron and platinum using off-line precolumn derivatization and extraction in chloroform. The complexes of cobalt(II), cobalt(III), iron(II), iron(III) and the reagent have been subsequently separated on a Microsorb C-18 column. The complexes were eluted isocratically using ternary mixtures of methanol/water/acetonitrile. Detection was achieved by UV monitoring. Detection limits for Co(II), Co(III), Fe(II) and Fe(III) were 2.5–5.0 ng/injection, based on 0.5–1.0 g/ml with 5 l/injection. The concentration of cobalt(II) and cobalt(III) in aqueous solution have been determined. The presence of oxovanadium(IV), platinum(II), and nickel(II) did not affect the determinations. The HPLC method developed has been applied to the determination of cobalt, copper, iron and platinum in pharmaceutical preparations at the 30 g/g to 15 mg/g level and the obtained results were compared to those of atomic absorption spectrometry.  相似文献   

9.
Khuhawar MY  Lanjwani SN 《Talanta》1998,46(4):485-490
The complexing reagent 2-thiophenaldehyde-4-phenyl-3-thiosemicarbazone (TAPT) was examined for high performance liquid chromatographic (HPLC) separations of cobalt(II), copper(II) and iron(II) or cobalt(II), nickel(II), iron(II), copper(II) and mercury(II) as metal chelates on a Microsorb C-18, 5-mum column (150x4.6 mm i.d.) (Rainin Instruments Woburn, MA, USA). The complexes were eluted isocratically with methanol:acetonitrile:water containing sodium acetate and tetrabutyl ammonium bromide (TBA). UV detection was at 254 nm. The solvent extraction procedure was developed for simultaneous determination of the metals, with detection limits within 0.5-2.5 mug ml(-1) in the final solution. The method was applied for the determination of copper, cobalt and iron in pharmaceutical preparation.  相似文献   

10.
 A new sensitive method exploiting solid-phase spectrophotometry is proposed for the determination of cobalt in pharmaceutical preparations. The chromogenic reagent 1-(2-thiazolylazo)-2-naphthol (TAN) was immobilized on C18 bonded silica loaded into a home-made cell with 1.5 mm of optical path for cobalt determination. Cobalt(II) reacts with TAN on C18 material, at pH 6.0–7.5, to give a coloured complex which has maximum absorption at 572 nm. In this way, the sample was passed through the cell and Co(II) ions were quantitatively retained on the solid-phase. After the direct measurement of light-absorption in the solid phase, only the cobalt was eluted with 0.1 mol L−1 hydrochloric acid. The cell was washed with water and then another sample solution could be passed through the cell. The procedure allowed the determination of cobalt in the range of 10–160 μg L−1 with coefficient of variation of 4.7% (n=10) and apparent molar absorptivity of 2.62 × 106 L mol−1 cm−1 using sample volume of 3-mL. Received May 15, 2000. Revision August 28, 2000.  相似文献   

11.
Reddy BR  Sarma PV 《Talanta》1994,41(8):1335-1339
Cyanex-272 forms a blue-colored complex with Co(II) in the organic phase. The complex shows three absorption maxima. The peak at 635 nm has been used for developing a spectrophotometric procedure for cobalt determination. Beer's law was found to be obeyed in the range 0.295-2.36 mg of cobalt. The nature of the extracted species was found to be CoR(2).HR. The molar absorptivity was found to be 3.07 x 10(2) l. mol(-1). cm(-1) at 635 nm. The method was applied for cobalt determination in solutions obtained from Beta Cake and a super alloy and was found to give values close to the actual ones. Easy regeneration of the reagent (Cyanex-272) for re-use is the main advantage of the present method.  相似文献   

12.
Ketoconazole, as a ligand, reacts quantitatively with copper(II) and cobalt(II) to form blue-colored, stable complexes in dichloromethane. These complexes can be spectrophotometrically measured at 720 and 612.5 nm in the case of Cu(II) or Co(II), respectively. Different factors affecting the reaction such as pH, reagent concentration, solvent effect, and time were studied. By using Job's method of continuous variation, the stoichiometry of the reaction was found to be in the ratio of 1:2, metal:drug, with Cu(II) and Co(II). The stability of the complexes formed was also studied. The reaction products were isolated for further investigation. The complexes have apparent molar absorptivities of 35.36 +/- 1.95 and 59.62 +/- 1.87 for Cu(II) and Co(II), respectively. Suggested procedures based on the stoichiometric reaction were successfully applied to the analysis of the pure drug and its pharmaceutical formulations. The validity of the procedures was further ascertained by the method of standard additions. The developed method was found to be simple, accurate, and precise when compared with the official method of the British Pharmacopoeia.  相似文献   

13.
In this work, a procedure for preconcentration of cobalt using dispersive liquid–liquid microextraction (DLLME) with the reagent Br-TAO as complexing reagent was developed. The procedure is based on a ternary system of solvents, where appropriate amounts of the extraction solvent, disperser solvent and the chelating agent Br-TAO are directly injected into an aqueous solution containing Co(II). A cloudy mixture is formed and the ions are extracted in the fine droplets of the extraction solvent. After extraction, the phase separation is performed with a rapid centrifugation, and cobalt is determined in the enriched phase by FAAS. Under the optimized conditions, the detection limit obtained was 0.9 µg L− 1. The enrichment factor and the consumptive index were 16 and 0.31 mL, respectively. The accuracy of the method was tested by the determination of cobalt in certified reference material of spinach leaves, NIST 1570a. The proposed procedure was successfully applied to the determination of cobalt in water samples.  相似文献   

14.
Endo M  Abe S  Deguchi Y  Yotsuyanagi T 《Talanta》1998,47(2):349-353
A highly sensitive and simple visual autocatalytic method has been developed for the determination of trace cobalt. The cobalt ion released by the oxidative decomposition of inert bis[2-(5-bromo-2-pyridylazo)-5-(N-propyl-N-sulfopropyl-amino-phenolato] cobaltate (Co(III)-5-Br-PAPS) with peroxomonosulfate acts as a catalyst for the oxidative degradation of the complex. Thus a definite time lapse of degradation is observed by the sudden disappearance of colored Co(III) complexes. The degradation time varies inversely with the logarithm of the initial concentration of cobalt(II). The determination range of cobalt(II) was from 3x10(-9) to 2x10(-7) M in the presence of 5x10(-6) M of 5-Br-PAPS. The relative standard deviation of the spot size method (10 mul) was 3.5% at 1x10(-7) M cobalt(II). This autocatalytic indicator reaction system has been successfully applied for the visual determination of urinary cobalt.  相似文献   

15.
HPLC was coupled with sequential injection (SI) for simultaneous analyses of some heavy metals, including Co(II), Ni(II), Cu(II), and Fe(II). 2-(5-Nitro-2-pyridylazo)-5-[N-propyl-N-(3-sulfopropyl)amino]phenol (nitro-PAPS) was employed as a derivatizing reagent for sensitive spectrophotometric detection by online precolumn derivatization. The SI system offers an automated handling of sample and reagent, online precolumn derivatization, and propulsion of derivatives to the HPLC injection loop. The metal-nitro-PAPS complexes were separated on a C(18)-muBondapak column (3.9x300 mm(2)). Using the proposed SI-HPLC system, determination of four metal ions by means of nitro-PAPS complexes was achieved within 13 min in which the parallel of derivatization and separation were processed at the same time. Linear calibration graphs were obtained in the ranges of 0.005-0.250 mg/L for Cu(II), 0.007-1.000 mg/L for Co(II), 0.005-0.075 mg/L for Ni(II), and 0.005-0.100 mg/L for Fe(II). The system provides means for automation with good precision and minimizing error in solution handling with the RSD of less than 6%. The detection limits obtained were 2 microg/L for Cu(II) and Co(II), and 1 microg/L for Ni(II) and Fe(II). The method was successfully applied for the determination of metal ions in various samples, including milk powder for infant, mineral supplements, local wines, and drinking water.  相似文献   

16.
The synthesis and analytical properties of di-2-pyridyl ketone guanylhydrazone (DPGH) are described. The reagent was tested with 37 cations but only Co(II), Ni(II), Cu(II), Fe(II) and Pd(II) gave colored complexes. The spectral characteristics of the reagent and the above complexes as well as the procedures for a selective determination of total iron, cobalt(II), copper(II), nickel(II) and palladium(II) are reported.  相似文献   

17.
The cycloaddition of the mono- and dichloroglyoximes to the cobalt(II) bis-α-benzyldioximate afforded the cobalt(II) mono- and dichloroclathrochelates in moderate yields (40-60%). These complexes undergo nucleophilic substitution of their reactive chlorine atoms with aliphatic amines, alcohols and thiolate anions. In the case of ethylenediamine and 1,2-ethanedithiol, only the macrobicyclic products with α,α'-N(2)- and α,α'-S(2)-alicyclic six-numbered ribbed fragments were obtained. The cobalt(II) cage complexes with terminal mercapto groups were synthesized using aliphatic dithiols. The crystal and molecular structures of the six cobalt(II) clathrochelates were obtained by X-ray diffraction. Their CoN(6)-coordination polyhedra possess a geometry intermediate between a trigonal prism and a trigonal antiprism, and the encapsulated cobalt(II) ions are shifted from their centres due to the structural Jahn-Teller effect with the Co-N distances varying significantly (by 0.10-0.26 ?). The electrochemistry of the complexes obtained was studied by cyclic voltammetry (CV). The anodic waves correspond to the quasi-reversible Co(2+/3+) oxidations, whereas the cathodic ranges contain the quasi-reversibile waves assigned to the Co(2+/+) reductions; all the cobalt(i)-containing clathrochelate anions formed are stable in the CV time scale. The electrocatalytic properties of the cobalt complexes obtained were studied in the production of hydrogen from H(+) ions: the addition of HClO(4) resulted in the formation of the same catalytic cathodic reduction Co(2+/+) waves. The controlled-potential electrolysis with gas chromatography analysis confirmed the production of H(2) in high Faraday yields. The efficiency of this electrocatalytic process was enhanced by an immobilization of the complexes with terminal mercapto groups on a surface of the working gold electrode.  相似文献   

18.
The electronebulization of a cobalt(II)/cysteine(Cys) mixture in water/methanol (50/50) produced mainly cobalt-cationized species. Three main groups of the Co-cationized species can be distinguished in the ESI-MS spectrum: (1) the cobalt complexes including the cysteine amino acid only (they can be singly charged, for example, [Co(Cys)n- H]+ with n = 1-3 or doubly charged such as [Co + (Cys)2]2+); (2) the cobalt complexes with methanol: [Co(CH3OH)n- H]+ with n = 1-3, [Co(CH3OH)4]2+; and (3) the complexes with the two different types of ligands: [Co(Cys)(CH3OH) - H]+. Only the singly charged complexes were observed. Collision-induced dissociation (CID) products of the [Co(Cys)2]2+, [Co(Cys)2 - H]+ and [Co(Cys) - H]+ complexes were studied as a function of the collision energy, and mechanisms for the dissociation reactions are proposed. These were supported by the results of deuterium labelling experiments and by density functional theory calculations. Since [Co(Cys) - H]+ was one of the main product ions obtained upon the CID of [Co(Cys)2]2+ and of [Co(Cys)2 - H]+ under low-energy conditions, the fragmentation pathways of [Co(Cys) - H]+ and the resulting product ion structures were studied in detail. The resulting product ion structures confirmed the high affinity of cobalt(II) for the sulfur atom of cysteine.  相似文献   

19.
Alpha-benzilmonoxime has been used for the extraction and determination of cobalt at microgram amount. The reagent reacts with cobalt(II) in the pH range of 8.8 - 9.3 to form a yellow-color chelate, which is extracted in chloroform, toluene, and some other non-polar solvents. The chelate is stable in chloroform for about one day. Under the optimum conditions of the a-benzilmonoxime concentration and pH of 9.0, Beer's law was obeyed in the concentration range of 0.08 - 2.2 microg/ml cobalt. The molar absorptivity of the extracted species was 2.55 x 10(4) dm3/mol cm at 380 nm, with a detection limit of 0.01 microg/ml cobalt. Relative standard deviations of 0.4, 0.8 and 2.3% were found for the determination of cobalt concentrations of 2.2, 1.1 and 0.08 microg/ml, respectively. The effect of diverse ions on the determination of 1.00 microg/ml of cobalt has been studied. The method was applied to the determination of cobalt in vitamin B12 and B-complex ampoules, a Co2O3-Co3O4 laboratory chemical mixture and some synthetic alloy samples. The method is sensitive, simple, rapid and accurate.  相似文献   

20.
建立了微晶蒽分离富集环境水样中痕量Co(II)的方法。在pH3.0条件下,1-亚硝基-2-萘酚与Co(II)形成红棕色螯合物被微晶蒽定量吸附,能使Co(II)与Pb(II)、Ni(II)、Mn(II)、Cu(II)、Cd(II)、Zn(II)、Fe(III)、Cr(III)、Al(III)等常见离子分离。本法富集倍数达100倍,检出限为0.14μg/L,回收率97.5%~105%,已应用于不同水样中Co(II)的测定。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号