首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 640 毫秒
1.
The application of TLC with a diode array detector (TLC-DAD) and HPLC-DAD after SPE for identification and quantitative analysis of pesticides in water samples is demonstrated. The procedures described for the determination of compounds are inexpensive and can be applied to routine analysis of analytes in water samples after preliminary cleanup and concentration by SPE. Average recoveries for four different cartridges and three solvents by the proposed HPLC-DAD method after SPE also are presented. The efficiency of the SPE procedure was evaluated using real water samples from the Zemborzycki Reservoir, near Lublin, southeastern Poland. The method was validated for precision, repeatability, and accuracy.  相似文献   

2.
This article described a new method for the sensitive determination of organophosphorus pesticides in water samples using SPE in combination with GC‐flame photometric detection. In the procedure of method development, TiO2 nanotubes were used as SPE adsorbents for the enrichment of organophosphorus pesticides from water samples. Several factors, such as eluent and its volume, sample pH, sample volume, sample flow rate, and concentration of humic acid, were optimized. Under the optimal conditions, the proposed method had good linear ranges as 0.1–40 μg/L for each of them, LOD of 0.11, 0.014, and 0.0025 μg/L, and LOQs of 0.37, 0.047, and 0.0083 μg/L for chlorpyrifos, phorate, and methyl parathion, respectively. The proposed method was validated with real environmental water samples and the spiked recoveries were over the range of 86.5–115.1%. All these results indicated that TiO2 nanotubes, as a new SPE adsorbent, would be used widespread for the preconcentraiton and determination of environmental pollutants in the future.  相似文献   

3.
Planar chromatography with diode array scanning (TLC-DAD) and high-performance chromatography with diode array detection (HPLC-DAD) were used to screen water samples for pesticides. Pesticides were enriched from lake water samples by SPE on C18/SDB-1, C18, C18 Polar Plus and cyanopropyl (CN) cartridges. The recovery rates were high for all extraction materials except for all pesticides on CN cartridges, for which the values were lower. SPE was used not only for preconcentration of analytes but also for their fractionation. The analytes were eluted first with methanol and then with dichloromethane. Methanol eluates were analysed by HPLC-DAD, the dichloromethane eluates with TLC-DAD. The method was validated for precision, repeatability and accuracy. The calibration plots were linear between 0.1 and 50.0 microg/mL for all pesticides, the correlation coefficients, r, were between 0.9992 and 1.000 as determined by HPLC-DAD. In the TLC experiments, the best fit for the calibration lines was found when the calibration data were analysed using a second-degree polynomial regression. Calibration plots lay between 0.1 and 17 microg/spot for all pesticides, the correlation coefficients, r, were between 0.9974 and 0.9997 determined by TLC-DAD. The LOD was between 0.04 and 0.65 microg/spot (TLC-DAD) and between 0.02 and 3.68 microg/mL (HPLC-DAD).  相似文献   

4.
A quantitative, selective and sensitive HPLC method for the analysis of 14 fungicides in white grapes for vinification is described. The proposed method is based on liquid-liquid extraction (LLE) and solid-phase extraction (SPE) followed by liquid chromatography and diode array detection (HPLC-DAD). Dichloromethane-acetone (75:25, v/v) was the most appropriate solvent mix for extracting fungicides in white grapes. Silica cartridges resulted the most appropriate for extract purification purposes. Quality parameters of the proposed multiresidue method presented good recovery (ca. 85% for almost all target compounds) and precision (between 1.5 and 16%), and detection limits lower than maxima residual limits set by the 76/895/ECC and 90/642/ECC Directive. Five different white grapes for vinification produced in Rias Baixas area in Galicia (NW Spain) were analyzed in order to assess the performance of the method with real samples and to determine whether the concentration of the pesticides used exceed their maxima residue levels (MRLs). Results showed that grape concentrations for those identified fungicides were lower than those established by European legislation.  相似文献   

5.
建立了一种固相萃取/高效液相色谱-串联质谱(SPE/HPLC-MS/MS)同时检测水体中24种农药的分析方法。样品用乙腈提取后,经固相萃取小柱富集净化。以乙腈-0.1%(体积分数)甲酸水溶液为流动相梯度洗脱,在电喷雾离子源正离子模式下(ESI+)采用多反应监测(MRM)模式检测。结果显示,24种农药在1~200μg/L范围内具有良好的线性关系,相关系数(r2)均不小于0.998,水样中3个添加水平(5、20、100μg/L)下的回收率为65.9%~127.8%,相对标准偏差(RSD)为0.7%~14.2%;方法检出限为0.05~0.71 ng/L。采用该方法对大连地区10个河流入海口及2个水库的水样进行了检测,12个站位的样品中共检出10种农药,质量浓度为0.2~558.3 ng/L。结果表明,所建立的SPE/HPLC-MS/MS方法高效、灵敏、可靠,可用于实际水体中多种农药的同时检测。  相似文献   

6.
A solid‐phase extraction (SPE) method was developed to extract 14 pesticides simultaneously from environment samples using cigarette filter as the sorbent before gas chromatography‐mass spectrometry (GC‐MS) analysis. Parameters influencing the extraction efficiency, such as the sample loading flow rate, eluent and elution volume, were optimized. The optimum sample loading rate was 3 mL/min, and the retained compounds were eluted with 6 mL of eluent at 1 mL/min under vacuum. Good linearity was obtained for all the 14 pesticides (r2>0.99) from 0.1 to 20 μg/L for water and from 2 to 400 μg/kg for soil samples. The detection limits (signal‐to‐noise=3) of the proposed method ranged from 0.01 to 0.20 μg/L for water samples and from 0.42 to 6.95 μg/kg for soil samples. The developed method was successfully applied for determination of the analytes in real environmental samples, and the mean recoveries ranged from 76.4 to 103.7% for water samples and from 79.9 to 105.3% for soil samples with the precisions (relative standard deviation) between 2.0 and 13.6%.  相似文献   

7.
The aim of this study is to report a new procedure for extraction, cleanup and determination of clofentezine in herb extracts by ultrasound‐assisted solvent extraction, SPE and multidimensional planar chromatography with diode array detector (MDPC‐DAD) and/or HPLC‐DAD. The application of various extraction solvents in SPE experiments conducted on octadecyl silane coupled with styrene‐divinylbenzene cartridges for fractionation and purification samples has been described. Normal‐phase systems were used in MDPC experiments on silica layer. The procedure described for the determination of compounds is inexpensive and can be applied to the routine analysis of analytes in plant extracts, after preliminary cleanup and concentration, e.g. by SPE. Application of MDPC‐DAD and HPLC‐DAD is especially useful for correct identification of components of difficult, complicated mixtures, e.g. analytes in medical herbs.  相似文献   

8.
Huang Y  Zhou Q  Xiao J 《The Analyst》2011,136(13):2741-2746
This paper described a new method for the enrichment and determination of pyrethroid pesticides from environmental water samples with ordered TiO(2) nanotube array micro-solid phase equilibrium extraction (μ-SPEE) prior to gas chromatography (GC) with electron capture detection (ECD). Several factors such as the anodization voltage, the kind of organic solvents, sample pH, equilibrium extraction time, desorption time and salting-out effect were optimized. Under the optimal conditions, ordered TiO(2) nanotube arrays demonstrated excellent merits on the preconcentration of pyrethroid pesticides and good detection limits were achieved as 0.018, 0.020, 0.031, 0.041, and 0.070 μg L(-1) for bifenthrin, fenpropathrin, cyhalothrin, fenvalerate, and deltamethrin, respectively. Four real water samples were used to validate the proposed method and the spiked recoveries were over the range of 81.9-110.6%. Compared to conventional solid phase extraction (SPE), the present method showed better recoveries and good reproducibility. These results showed that this μ-SPEE technique could be an important alternative to multistep SPE for the extraction and determination of such analytes in complex samples and become a useful tool in monitoring such analytes in the environment.  相似文献   

9.
High-performance thin-layer chromatography with diode array scanning (TLC-DAD) and high-performance column liquid chromatography with a diode array detector (HPLC-DAD) were used to screen water samples for pesticides. Atrazine, clofentezine, chlorfenvinphos, hexaflumuron, terbuthylazine, lenacyl, neburon, bitertanol, and metamitron were enriched from canal water samples by solid-phase extraction (SPE) on octadecyl silane (C18)/styrene-divinylbenzene-1, C18, C18 Polar Plus, and cyanopropyl (CN) cartridges. Recovery rates were high for all extraction materials except CN, for which values for all pesticides were lower. SPE was used for both preconcentration and fractionation of the analytes. Analytes were eluted by means of methanol and dichloromethane. Methanol eluates were analyzed by HPLC-DAD and dichloromethane eluates by TLC-DAD. The method was validated for precision, repeatability, and accuracy. Calibration graphs were linear between 0.1 and 50.0 microg/mL for all pesticides, and correlation coefficient (r) values were between 0.9994 and 1.000 as determined by HPLC-DAD. Calibration graphs were linear between 0.1 and 1.5 microg/spot for all pesticides, and r values were between 0.9899 and 0.9987 as determined by TLC-DAD. The limit of detection was between 0.04 and 0.23 microg/spot for TLC-DAD and 0.02 and 0.45 microg/mL for HPLC-DAD.  相似文献   

10.
Song W  Lin S  Sun G  Chen M  Yuan D 《色谱》2012,30(3):318-326
采用固相萃取-气相色谱-质谱联用技术,建立了河水和海水中87种农药(24种有机磷、15种有机氯、12种唑类、9种拟除虫菊酯类、5种氨基甲酸酯类、7种酰胺类及15种其他新型农药)的多残留同时分析方法。优化了影响分离效果和灵敏度的仪器参数,考察了固相萃取柱柱型及水样体积、pH、盐度的影响,采用NH2柱优化了净化效果,内标法和替代物法用于数据的质量控制。结果表明: 在最佳条件下,各目标农药的方法检出限为0.1~6.6 ng/L;以实际河水和海水为基底,在5 ng/L和20 ng/L的加标水平下,绝大多数目标农药的回收率为60%~120%,相对标准偏差(n=4)为0.01%~9.7%。该法灵敏、准确,已成功地应用于福建九龙江河口区表层水样中多种类农药的复合污染监测,检出包括5种有机磷类、3种酰胺类、4种唑类、3种氨基甲酸酯类、2种拟除虫菊酯类等农药20种。  相似文献   

11.
A new analytical method for the determination of organophosphorus pesticides in cereal samples was developed by combining dispersive SPE (d‐SPE) and salting‐out homogeneous liquid–liquid extraction (SHLLE). The pesticides were first extracted from cereal grains with acetonitrile, followed by d‐SPE cleanup. A 2 mL aliquot of the extract was then added to a centrifuge tube containing 9.2 mL water and 3.3 g NaCl for SHLLE. Analysis of the extract was carried out by gas chromatography coupled with flame photometric detection. The d‐SPE procedure effectively provides the necessary cleanup of the extract while SHLLE is used as an efficient concentration technique. Experimental parameters influencing the extraction efficiency including amounts of added water and salt were investigated. Recovery studies were carried out at three fortification levels, yielding recoveries in the range of 57.7–98.1% with the RSD from 3.7 to 10.9%. The reported limits of determination obtained from this study were 1 μg/kg, which is better than the conventional methods. In the analysis of 40 wheat and corn samples taken from Beijing suburbs, only two wheat samples have chlorpyrifos residue over the limits of determination.  相似文献   

12.
In this work, the simultaneous analysis of five triazolopyrimidine sulfoanilide herbicides (flumetsulam, florasulam, metosulam, cloransulam-methyl, and diclosulam) by HPLC using UV detection and a C18 monolithic column is proposed. The mobile phase which was composed of ACN, water, and formic acid was pumped at a high flow rate (5 mmL/min) providing an analysis time of all the compounds in less than 2.3 min. The LODs were in the low microg/L range (i.e. between 60 microg/L for flumetsulam and 90 microg/L for florasulam) and the calibration curves showed good linearity (R2 > 0.9949). The method was applied to the analysis of these compounds in spiked mineral and tap waters and soils after an SPE preconcentration procedure using C18 cartridges. Mean recovery values ranged between 35 and 110% for water samples providing LODs of the whole procedure in the low ng/L level, down to 280 ng/L, and between 77 and 92% for soil samples with LODs down to 9.38 microg/kg. This is the first time that this family of pesticides is simultaneously analyzed in both types of samples by HPLC and also using a monolithic column.  相似文献   

13.
A highly selective sample cleanup procedure combined with molecularly imprinted SPE was developed for the isolation of crystal violet from seawater and seafood samples. The molecularly imprinted polymer was prepared using crystal violet as the template molecule, methacrylic acid as the functional monomer, and ethylene glycol dimethacrylate as the cross‐linker. The crystal violet‐imprinted polymer was used as the selective sorbent for the SPE of crystal violet. An off‐line molecularly imprinted SPE method followed by HPLC with diode‐array detection for the analysis of crystal violet was also established. Good linearity on the molecularly imprinted SPE columns was obtained from 0 to 200 μg/L (R2 > 0.99). The result demonstrated that the proposed method can be used for the direct determination of crystal violet in seawater and seafood samples. Finally, five samples were analyzed and the following crystal violet concentrations were obtained: 0.92 and 0.52 μg/L in two seawater samples, as well as 0.36 and 0.27 μg/kg in two seafood samples. There is no crystal violet detected in the third seawater sample.  相似文献   

14.
In this work, the analysis of a group of four fungicides (pyrimethanil, nuarimol, procymidone and cyprodinil) and one insecticide (pirimicarb) by micellar electrokinetic chromatography (MEKC) with UV detection using the on-line preconcentration strategy called reversed electrode polarity stacking mode (REPSM) is proposed. After optimisation, an adequate separation electrolyte for the separation and stacking of these pesticides was obtained which consisted of 100 mM borate, 60 mM sodium dodecyl sulphate (SDS), at pH 9.0 and 2% 2-propanol. The use of this running buffer together with the REPSM preconcentration method provided limits of detection (LODs) between 38.3 and 241 microg/L. In order to apply the developed methodology for the analysis of these pesticides in wine samples, several off-line preconcentration strategies (mainly, solid-phase extraction, SPE, and solid-phase microextraction, SPME) were tested. Although the use of a SPE procedure, optimized in this work for water samples, using Oasis HLB cartridges, provided mean recovery values between 79 and 100% for spiked water samples, it could not be applied to the extraction of these pesticides from wine samples due to high interference from the sample matrix. However, the use of a SPME procedure using polydimethylsiloxane/divynilbenzene (PDMS/DVB) fibers allowed the selective extraction of four of the five pesticides which could be perfectly determined. The final combination of the off-line SPME and on-line REPSM preconcentration strategies allowed obtaining LODs between 17.6 and 32.3 microg/L.  相似文献   

15.
Shi XZ  Song SQ  Sun AL  Liu JH  Li DX  Chen J 《The Analyst》2012,137(2):437-443
A simple, efficient, and environmentally friendly membrane-assisted solvent extraction (MASE) method for the extraction and preconcentration of six pyrethroid insecticides from aquaculture seawater samples followed by gas chromatography-electron capture detection (GC-ECD) was successfully proposed. The operating conditions for MASE, such as the extraction solvent, solvent volume, NaCl concentration, stirring rate, extraction time, and temperature, were optimized. Compared to conventional Florisil-solid phase extraction (SPE), higher extraction recoveries (85.9% to 105.9%) of three spiked levels of the six pyrethroid pesticides in aquaculture seawater were obtained using MASE, and the RSD values were lower than 7.9%. The limits of detection (LOD, signal-to-noise ratio (S/N)=3) and quantification (LOQ, S/N = 10) were in the range of 0.037-0.166 and 0.12-0.55 μg L(-1), respectively. The results demonstrate the excellent applicability of the MASE method in analyzing the six pyrethroid pesticides in aqueous samples. The proposed method exhibited a high potential for routine monitoring analysis of pyrethroid insecticides in seawater samples.  相似文献   

16.
A new mesoporous silica based on the sol–gel material cyanopropyltriethoxysilane (CNPrTEOS) was successfully synthesized by the hydrolysis and condensation of CNPrTEOS in the presence of ammonium solution as catalyst and methanol as solvent. It was used as a solid‐phase extraction sorbent for the simultaneous extraction of three organophosphorus pesticides, namely, polar dicrotophos and non‐polar diazinon and chlorpyrifos. Analysis was performed using high‐performance liquid chromatography with UV detection. CNPrTEOS was characterized by FTIR spectroscopy, field‐emission scanning electron microscopy and nitrogen gas adsorption. The surface area and average pore diameter of the optimum sol–gel CNPrTEOS are 379 m2/g and 4.7 nm (mesoporous), respectively. The proposed solid‐phase extraction based on CNPrTEOS exhibited good linearity in the range of 0.8–100 μg/L, satisfactory precision (1.15–3.82%), high enrichment factor (800) and low limit of detection (0.072–0.091 μg/L). The limits of detection obtained using the proposed solid‐phase extraction method are well below the maximum residue limit set by European Union and are also lower (13.6–48.5×) than that obtained by using a commercial CN‐SPE cartridge (0.98–4.41 μg/L). The new mesoporous sol–gel CNPrTEOS showed promising alternative as SPE sorbent material for the simultaneous extraction of polar and non‐polar organophosphorus pesticides.  相似文献   

17.
固相萃取-GC/MS法测定水样中20种有机氯农药   总被引:2,自引:0,他引:2  
建立了用固相萃取小柱提取和净化、GC/MS定性定量同时测定水样中20种有机氯农药的方法。方法采用OasisHLB固相萃取小柱萃取富集水样,二氯甲烷洗脱,加入菲-d10作为内标,利用GC/MS进行定性定量,步骤简便,线性响应良好,干扰小,方法检出限为0.21~0.72 ng/L(按水样1L计),加标回收率为64.8%~122%,RSD为1.2%~11.0 %。成功利用该方法对广西实际河水样品进行了检测。结果表明方法可以同时满足环境水样中20种痕量有机氯农药的测定。  相似文献   

18.
In this study, a new procedure, based on on-line solid-phase extraction (SPE) and analysis by liquid-chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS), has been developed for the simultaneous, multianalyte determination of 21 selected pesticides, phenols and phthalates in water. SPE was carried out on polymeric PLRP-s cartridges by percolating 20 mL-samples. For sample preconcentration, the performance of a prototype programmable field extraction system (PROFEXS) was evaluated against the commercial laboratory bench Prospekt system used for method development. The Profexs is designed for the automated on-site sampling, SPE preconcentration, and storage of up to 16 samples in SPE cartridges. These cartridges are further eluted and on-line analyzed with the Prospekt coupled to the chromatographic system. In the optimized method, where completely on-line SPE-LC-MS analysis of the samples is carried out with the Prospekt in the laboratory, detection limits lower than 100 ng/L, and satisfactory precision (relative standard deviations <25%) and accuracies (recovery percentages >75%) were obtained for most investigated compounds from the analysis of spiked Milli-Q water. The extraction efficiency achieved with the Profexs was comparable to that of the Prospekt for most compounds and somewhat lower for the most apolar analytes, probably due to adsorption on the pump filters. The completely on-line optimized method was applied to the analysis of surface water, ground water and drinking water from a waterworks in Barcelona. Some pesticides and phenols were found in both surface water and groundwater at ng/L or µg/L levels, but not in the final drinking water. Di(2-ethylhexyl)phthalate (DEHP) was present in all samples investigated, including blanks. To the author's knowledge, this is the first work describing the application of a fully automated on-line SPE-LC-MS method for the simultaneous analysis of pesticides, phenols, and phthalates in water, and the second one that examines the possibilities of the prototype Profexs for automated on-site SPE preconcentration of organic pollutants from water samples.  相似文献   

19.
A method for analysis of 20 commonly used pesticides in surface water based on solid-phase extraction and gas chromatography-mass spectrometry was proposed. During method development the key parameters that can affect SPE extraction and determination such as selection of efficient SPE sorbent, pH of water sample, type and volume of elution solvent, breakthrough volume and matrix effects were investigated. The method was validated using spring water spiked with appropriate concentration of pesticides. The obtained correlation coefficients were in range 0.9972–1.000, limits of detection (LOD) were 0.001–0.5?µg?L?1 and the limits of quantification (LOQ) were 0.005–1?µg?L?1 depending on a pesticide. Much higher LOD (20?µg?L?1) and LOQ (50?µg?L?1) values were obtained for bentazone. The influence of matrix was assessed using real water samples spiked with appropriate concentration of pesticide standards solution. Both signal enhancement and suppression were observed, depending on a pesticide, therefore standard addition method was used for pesticides determination. The developed method was applied on real water samples taken in close vicinity of agricultural fields. Many of the targeted pesticides were found in the samples and the results are presented in this article.  相似文献   

20.
对多壁碳纳米管(MWNTs)的表面进行酸氧化处理制备了改性的MWNTs,并建立了以改性MWNTs作为固相萃取(SPE)吸附剂测定农产品中痕量残留的4种有机氯农药(p,p′-DDD、p,p′-DDT、o,p′-DDT、p,p′-DDE)的SPE-高效液相色谱(HPLC)分析方法。考察了氧化处理条件、SPE操作条件和色谱条件等对有机氯农药残留测定的影响,优化了实验条件。在优化实验条件下,4种农药在较宽线性范围内线性良好,相关系数为0.9978~0.9995,检出限为0.050 mg/L;在样品中分别添加0.10、2.0、50 mg/L的4种农药,其加标回收率为78%~104%,相对标准偏差(RSD)为2.7%~7.6%。MWNTs作为SPE填料用于陈皮、西洋参、卷心菜和茶叶等样品的净化效果良好,测定结果准确,灵敏度高,符合农产品中痕量农药残留的分析方法要求,为农产品中此类农药的痕量残留分析提供了有益的参考。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号