首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The development of novel and reliable technologies for the analysis of proteins and their post-translational modifications, in particular, has recently received much attention and interest. The implementation of a fully integrated microfluidic device interfaced with MS detection for the analysis of phosphoproteins is presented in this paper. The microfluidic platform (3'x1.5') comprises two individual sample processing systems: one for performing direct sample infusion and one for performing microfluidic LC separations. Various MS detection strategies, specific for the study of post-translational modifications, were conducted using alpha-casein as a model protein. Neutral loss ion mapping, data-dependent triple-play and neutral loss analysis, and in situ dephosphorylation followed by LC separation and MS detection were performed. Consistent results in identifying phosphopeptides with conventional and microfluidic instrumentation have been obtained. Unlike with conventional instrumentation, however, the microfluidic device enabled the completion of each analysis from only a few microliters of sample, in approximately 10-15 min, and on a bioanalytical platform that facilitates multiplexing and disposability, and thus high-throughput, contamination-free analysis.  相似文献   

2.
Mass spectrometric imaging allows the investigation of the spatial distribution of molecules at complex surfaces. The combination of molecular speciation with local analysis renders a chemical microscope that can be used for the direct biomolecular characterization of histological tissue surfaces. MS based imaging advantageously allows label-free detection and mapping of a wide-range of biological compounds whose presence or absence can be the direct result of disease pathology. Successful detection of the analytes of interest at the desired spatial resolution requires careful attention to several steps in the mass spectrometry imaging protocol. This review will describe and discuss a selected number of crucial developments in ionization, instrumentation, and application of this innovative technology. The focus of this review is on the latest developments in imaging MS. Selected biological applications are employed to illustrate some of the novel features discussed. Two commonly used MS imaging techniques, secondary ion mass spectrometric (SIMS) imaging and matrix-assisted laser desorption ionization (MALDI) mass spectrometric imaging, center this review. New instrumental developments are discussed that extend spatial resolution, mass resolving power, mass accuracy, tandem-MS capabilities, and offer new gas-phase separation capabilities for both imaging techniques. It will be shown how the success of MS imaging is crucially dependent on sample preparation protocols as they dictate the nature and mass range of detected biomolecules that can be imaged. Finally, developments in data analysis strategies for large imaging datasets will be briefly discussed.  相似文献   

3.
刘璐瑶  秦洪强  叶明亮 《色谱》2021,39(10):1045-1054
蛋白质糖基化是生物体内最重要的翻译后修饰之一,在蛋白质稳定性、细胞内和细胞间信号转导、激素活化或失活和免疫调节等生理过程和病理进程中发挥重要作用.而异常的蛋白质糖基化往往和多种疾病的发生发展密切相关,目前应用于临床检测的多种肿瘤生物标志物大多属于糖蛋白或者糖抗原.因此在组学层次系统分析蛋白质糖基化的变化对阐明生物体内糖...  相似文献   

4.
Protein glycosylation is involved in a broad range of biological processes that regulate protein function and control cell fate. As aberrant glycosylation has been found to be implicated in numerous diseases, the study and large-scale characterization of protein glycosylation is of great interest not only to the biological and biomedical research community, but also to the pharmaceutical and biotechnology industry. Due to the complex chemical structure and differing chemical properties of the protein/peptide and glycan moieties, the analysis and structural characterization of glycoproteins has been proven to be a difficult task. Large-scale endeavors have been further limited by the dynamic outcome of the glycosylation process itself, and, occasionally, by the low abundance of glycoproteins in biological samples. Recent advances in MS instrumentation and progress in miniaturized technologies for sample handling, enrichment and separation, have resulted in robust and compelling analysis strategies that effectively address the challenges of the glycoproteome. This review summarizes the key steps that are involved in the development of efficient glycoproteomic analysis methods, and the latest innovations that led to successful strategies for the characterization of glycoproteins and their corresponding glycans. As a follow-up to this work, we review innovative capillary and microfluidic-MS workflows for the identification, sequencing and characterization of glycoconjugates.  相似文献   

5.
The ability to fabricate microfluidic systems with complex structures and with compatible dimensions between the microfluidics and biological cells have attracted significant attention in the development of microchips for analyzing the biophysical and biochemical functions of cells. Just as cell-based microfluidics have become a versatile tool for biosensing, diagnostics, drug screening and biological research, detector modules for cell-based microfluidics have also undergone major development over the past decade. This review focuses on detection methods commonly used in cell-based microfluidic systems, and provides a general survey and an in-depth look at recent developments in optical and electrochemical detection methods for microfluidic applications for biological systems, particularly cell analysis. Selected examples are used to illustrate applications of these detection systems and their advantages and weaknesses.  相似文献   

6.
As the title implies, the author undertakes a personal retrospective on the developments that since 1965 have shaped MS and taken it from a position of simply playing a role in protein chemistry to becoming an indispensable tool in proteomics, all in the past 40-year span. The article reviews the MS timeline of events, stopping at various time points where MS made significant contributions to protein chemistry or where the development of new instrumentation for MS represented a major advance for peptide and protein work. Major highlights in the field and their significance for peptide and protein characterization are covered, starting from the pioneering work carried out in the 1960s on peptide derivative formation and sequencing with instrumentation proper of that time, to later work done with triple, quad, and four-sector instruments, and on to the more recent work on the characterization of the proteome with ion traps, time-of-flight (TOF) instruments, and new ionization and tagging techniques.  相似文献   

7.
Glycosylation is one of the most common posttranslational modifications (PTMs) of proteins, the characterization of which is commonly achieved through proteomic protocol, involving trypsin digestion followed by liquid chromatography/tandem mass spectrometry (LC/MS/MS). However, it is often not possible to characterize all glycopeptides in a complex sample because of the high complexity of glycoproteomic samples, and the relative lower abundances of glycopeptides in comparison to the unmodified peptides. We present here a targeted MS/MS analysis approach, which utilizes a previously developed computational tool, GlyPID, to guide multiple experiments, thus permitting a complete characterization of all N‐glycosylation sites of glycoproteins present in a complex sample. We have tested our approach using model glycoproteins analyzed by high‐resolution LTQ‐FT MS. The results demonstrate a potential use of our method for a high‐throughput characterization of complex mixtures of glycosylated proteins. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

8.
Chen J  Li J  Sun Y 《Lab on a chip》2012,12(10):1753-1767
This article reviews the recent developments in microfluidic technologies for in vitro cancer diagnosis. We summarize the working principles and experimental results of key microfluidic platforms for cancer cell detection, characterization, and separation based on cell-affinity micro-chromatography, magnetic activated micro-sorting, and cellular biophysics (e.g., cell size and mechanical and electrical properties). We examine the advantages and limitations of each technique and discuss future research opportunities for improving device throughput and purity, and for enabling on-chip analysis of captured cancer cells.  相似文献   

9.
A microfluidic system has been designed that integrates both imaged capillary isoelectric focusing (iCIEF) separations and downstream MS detection into a single assay. Along with the construction of novel instrumentation and an innovative microfluidic chip, conversion to MS‐compatible separation reagents has also been established. Incorporation of 280 nm absorbance iCIEF‐MS analysis not only permits photometric quantitation of separated charge isoforms but also facilitates the direct monitoring of analyte focusing and mobilization in real‐time. The outcome of this effort is a device with the unique ability to allow for both the characterization and identification of protein charge and mass isoforms in under 15 min. Acquisition, quantitation, and identification of highly resolved intact mAb charge isoforms along with their critical N‐linked glycan pairs clearly demonstrate analytical utility of our innovative system. In total, 33 separate molecular features were characterized by the iCIEF‐MS system representing a dramatic increase in the ability to monitor multiple intact mAb critical quality attributes in a single comprehensive assay. Unlike previously reported CIEF‐MS results, relatively high ampholyte concentrations, of up to 4% v/v, were employed without impacting MS sensitivity, observed to be on the order of 1% composition.  相似文献   

10.
Pioch M  Bunz SC  Neusüss C 《Electrophoresis》2012,33(11):1517-1530
Advanced analytical techniques play a crucial role in the pharmaceutical and biotechnological field. In this context, capillary electrophoresis/mass spectrometry (CE/MS) has attracted attention due to efficient and selective separation in combination with powerful detection allowing identification and detailed characterization. Method developments and applications of CE/MS have been focused on questions not easily accessible by liquid chromatography/mass spectrometry (LC/MS) as the analysis of intact proteins, carbohydrates, and various small molecules, including peptides. Here, recent approaches and applications of CE/MS relevant to (bio)pharmaceuticals are reviewed and discussed to show actual developments and future prospects. Based on other reviews on related subjects covering large parts of previous works, the paper is focused on general ideas and contributions of the last 2 years; for the analysis of glycans, the period is extended back to 2006.  相似文献   

11.
Wang J  Zhou S  Huang W  Liu Y  Cheng C  Lu X  Cheng J 《Electrophoresis》2006,27(15):3108-3124
This review focuses on the developments and trends in CE including CIEF, CZE, MEKC, two-dimensional conjunction of CIEF-capillary gel electrophoresis, and MEKC-CZE on microfluidic devices coupled to different detection approaches, such as UV absorbance, LIF, MS, and chemiluminescence etc. for performing analysis of hemoglobin (Hb), also with an emphasis on its applications in clinical analysis. Analysis of human Hb is of important clinical sense for numerous hemoglobinopathies associated with the congenital defects and abnormal contents of Hb. The diversiform modes render CE a comprehensive primary clinical tool for Hb analysis, which is rapid, sensitive, high-resolution, and not labor-intensive.  相似文献   

12.
Amon S  Zamfir AD  Rizzi A 《Electrophoresis》2008,29(12):2485-2507
This review highlights recent developments in glycosylation analysis by modern MS in combination with CE based preseparation. Focused on CE-MS strategies aimed for glycotyping, the review addresses the detailed glycoform analysis of glycoproteins, glycopeptides, and proteoglycans. Glycoform analysis in the context of modern glycoproteomics is briefly addressed, as well. CZE, CIEF, and frontal analysis CE approaches hyphenated to high-resolution multistage MS for the detailed analysis of protein-linked glycan structures are overviewed in a comprehensive way. Advantages and limitations of various methodological approaches and techniques as well as mass spectrometric instrumentation are discussed in the particular context of glycoanalysis.  相似文献   

13.
Ghanim MH  Abdullah MZ 《Talanta》2011,85(1):28-34
Recent advances in microfluidic systems, particularly in the Micro Total Analysis System (μTAS) or Lab On a Chip (LOC), drive the current analysis tools and equipment towards miniaturization, rapid at-line testing and mobility. The state-of-the-art microfluidic technology targets a wider range but smaller volumes of analytes, making the analytical procedure relatively easier and faster. This trend together with faster electronics and modern instrumentation systems will make real-time and in situ analysis a definite possibility. This review focuses on microchip capillary electrophoresis with amperometric detection (MCE-AD) for the detection of DNA and other electroactive analytes. The problems associated with the microchip design, in particular the choice of materials and the configuration of electrodes are discussed thoroughly and solutions are proposed. Significant developments in the related areas are also covered and reviewed critically.  相似文献   

14.
Biomarkers are relevant indicators of the physiological state of an individual. Although biomarkers can be found in diseased tissue and different biofluids, sampling from blood plasma is relatively easy and less invasive. Among the molecular biomarkers that can be found circulating in plasma are proteins, metabolites, nucleic acids, and exosomes. Some of these plasma-circulating biomarkers are now employed for patient stratification in a broad range of diseases with high sensitivity and specificity and are useful in early diagnosis, initial risk assessment, and therapy selection. However, there is a pressing need to develop novel approaches for biomarker analysis that can be translated into clinical or other settings without complex methodologies or instrumentation. Microfluidics has been touted as a promising technology to carry out this task because it offers high-throughput, automation, multiplexed detection, and portability, possibly overcoming the bottleneck that prevent the translation of novel biomarkers to the point-of-care (POC). Here, we provide a review of the microfluidic systems that have been engineered to detect circulating molecular biomarkers in blood plasma. We also review the different microfluidic approaches for plasma enrichment, which are now being integrated with microfluidic-based biomarker analyzers. Such integration should lead to cost-effective solutions in in vitro diagnostics, with special relevance to POC platforms.  相似文献   

15.
Chien RL 《Electrophoresis》2003,24(3):486-497
One of the major challenges in capillary electrophoresis and other miniaturization separation techniques is to maintain high detection sensitivity in the increasingly smaller dimension. Numerous on-column sample preconcentrating procedures, based either on electrokinetic focusing or chromatographic effects, have been developed. This review will discuss some practical approaches to sample stacking from a personal perspective. Several recent developments in sample stacking on microfluidic devices are reviewed.  相似文献   

16.
Compound annotation using MS/MS data is the major bottleneck in interpretation of mass spectrometry data during non-targeted screening and suspect screening exposomics studies. Apart from compound identification using available databases or mass spectral libraries, the true challenge comes when completely new compounds have to be identified. Along with recent advances in MS instrumentation that set grounds to a new revolutionary age in environmental exposomics, a multitude of cheminformatics annotation approaches has been developed. Herein, we review the basic principles of the cutting-edge cheminformatics MS-based approaches employed in eco-exposome annotation.We give a solid background discussing the eco-exposome concept in relation to the advances in MS instrumentation, and define the three crucial cheminformatics tasks used in the eco-exposome annotation: molecular formula assignment, compound prioritization and compound annotation. The basic principles of compound annotation are discussed, which are based on three approaches of utilizing structural information inherent to MS data. These involve direct, indirect and joint annotation approaches. We assess their performance through the ability to annotate eco-exposome constituents. We discuss future perspectives and give directions to new annotation strategies and performance evaluation protocols aiming to solve current issues hampering the incorporation of cheminformatics annotation approaches in regular eco-exposome annotation workflows.  相似文献   

17.
Zauner G  Deelder AM  Wuhrer M 《Electrophoresis》2011,32(24):3456-3466
This review presents recent progress in employing hydrophilic interaction liquid chromatography (HILIC) for glycan and glycopeptides analysis. After an introduction of this technique, the following themes are addressed: (i) implementation of HILIC in large-scale studies for analyzing the human plasma N-glycome; (ii) the use of HILIC UPLC (ultrahigh pressure liquid chromatography) for fast high-resolution runs and its successful application with online MS for glycan and glycopeptide analysis; (iii) high-throughput profiling using HILIC solid-phase extraction in combination with MS detection; (iv) HILIC sample preparation for CE and CGE; (v) the latest glycoproteomic approaches implementing HILIC separation; (vi) future perspectives of HILIC including its use in large-scale glycoproteomics studies such as the analysis of entire glycoproteomes at the glycopeptide level.  相似文献   

18.
Recent mass spectrometry instrumentation developments include the appearance of novel hybrid tandem instrumentation, Q-TOF, consisting of a quadrupole mass analyzer (MS1) and a time-of-flight (TOF) analyzer. The TOF analyzer is not scanned, but collects all fragment ions entering the analyzer at a given time. Thus, the typical precursor scan experiment cannot be performed. Instead, a full MS-MS spectrum can be acquired for each mass passed by MS1. Appropriate data manipulation, i.e. extracted ion current chromatograms, can correlate specific fragment ion formation to the parent ion. Precursor scanning and LC-MS-MS are compared on a Q-TOF instrument for the determination of protein modifications, including acetylation and phosphorylation. Model peptides used for phosphopeptide detection were generated from a mixture of beta-casein. Model acetylated peptides were generated from a mixture of acetylated substance P1-9 and substance P1-11. The results were then applied to a more complex mixture, a digest of HIV-p24. Results indicate that precursor scanning is useful for screening, but that LC-MS-MS has a sensitivity advantage and is less susceptible to suppression effects. LC-MS-MS, therefore, appears to be better for the detection of trace components in complex mixtures.  相似文献   

19.
The hyphenation of capillary electrophoresis and mass spectrometry (CE/MS) remains a minor technique compared with liquid chromatography/mass spectrometry (LC/MS), which represents nowadays the standard instrumentation, regardless of its introduction thirty years ago. However, from a theoretical point of view, CE coupling should be quite favorable especially with electrospray ionization mass spectrometry (ESI‐MS). At the time, the sensitivity provided by CE/MS was often limited, due to hyphenation requirements, which at some point appeared to disqualify CE/MS from benefiting from the performance gain driving the evolution of MS instruments. However, this context has been significantly modified in a matter of a few years. The development of innovative CE/MS interfacing systems has enabled an important improvement regarding sensitivity and reinforced robustness in order to provide an instrumentation accessible to the largest scientific community. Because of the unique selectivity delivered by the electrophoretic separation, CE/MS has proved to be particularly relevant for the analysis of biological molecules. The conjunction of these aspects is motivating the interest in CE/MS analysis and shows that CE/MS is mature enough to enrich the toolbox of analytical techniques for the analysis of complex biological samples. Here we discuss the characteristics of the major types of high‐sensitivity CE/ESI‐MS instrumentation and emphasize the late evolution and future positioning of CE/MS analysis for the characterization of biological molecules like peptides and proteins, through some pertinent applications.  相似文献   

20.
In the screening of complex mixtures, for example combinatorial libraries, natural extracts, and metabolic incubations, different approaches are used for integrated bioaffinity screening. Four major strategies can be used for screening of bioactive mixtures for protein targets—pre-column and post-column off-line, at-line, and on-line strategies. The focus of this review is on recent developments in post-column on-line screening, and the role of mass spectrometry (MS) in these systems. On-line screening systems integrate separation sciences, mass spectrometry, and biochemical methodology, enabling screening for active compounds in complex mixtures. There are three main variants of on-line MS based bioassays: the mass spectrometer is used for ligand identification only; the mass spectrometer is used for both ligand identification and bioassay readout; or MS detection is conducted in parallel with at-line microfractionation with off-line bioaffinity analysis. On the basis of the different fields of application of on-line screening, the principles are explained and their usefulness in the different fields of drug research is critically evaluated. Furthermore, off-line screening is discussed briefly with the on-line and at-line approaches.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号