首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Pulsed Q collision induced dissociation (PQD) was developed to facilitate detection of low-mass reporter ions from labeling reagents (e.g., iTRΑQ) in peptide quantification using an LTQ mass spectrometer (MS). Despite the large number of linear ion traps worldwide, the use and optimization of PQD for protein identification have been limited, in part due to less effective ion fragmentation relative to the collision induced dissociation (CID). PQD expands the m/z coverage of fragment ions to the lower m/z range by circumventing the typical low mass cut-off of an ion trap MS. Since database searching relies on the matching between theoretical and observed spectra, it is not clear how ion intensity and peak number might affect the outcomes of a database search. In this report, we systematically evaluated the attributes of PQD mass spectra, performed intensity optimization, and assessed the benefits of using PQD on the identification of peptides and phosphopeptides from an LTQ. Based on head-to-head comparisons between CID (higher intensity) and PQD (better m/z coverage), peptides identified using PQD generally have Xcorr scores lower than those using CID. Such score differences were considerably diminished by the use of 0.1% m-nitrobenzyl alcohol (m-NBA) in mobile phases. The ion intensities of both CID and PQD were adversely affected by increasing m/z of the precursor, with PQD more sensitive than CID. In addition to negating the 1/3 rule, PQD enhances direct bond cleavage and generates patterns of fragment ions different from those of CID, particularly for peptides with a labile functional group (e.g., phosphopeptides). The higher energy fragmentation pathway of PQD on peptide fragmentation was further compared to those of CID and the quadrupole-type activation in parallel experiments.  相似文献   

2.
Quantitative mass spectrometry-based proteomic assays often suffer from a lack of robustness and reproducibility. We here describe a targeted mass spectrometric data acquisition strategy for affinity enriched subproteomes—in our case the kinome—that enables a substantially improved reproducibility of detection, and improved quantification via isobaric tags. Inclusion mass lists containing m/z, charge state, and retention time were created based on a set of 80 shotgun-type experiments performed under identical experimental conditions. For each target protein, peptides were selected according to their frequency of observation and isobaric tag for relative and absolute quantitation (iTRAQ) reporter ion quality. Retention times of selected peptides were aligned using similarity driven pairwise alignment strategy yielding <1 min standard deviation for 4 h gradients. Multiple fragmentation of the same peptides resulted in better statistics and more precise reporter ion based quantification without any loss in coverage. Overall, 24% more target proteins were quantified using the targeted data acquisition approach, and precision of quantification improved by >1.5-fold. We also show that a combination of higher energy collisional dissociation (HCD) with collisional induced dissociation (CID) outperformed pulsed-Q-dissociation (PQD) on the OrbitrapXL. With the CID/ HCD based targeted data acquisition approach 10% more quantifiable target proteins were identified and a 2-fold increase in quantification precision was achieved. We have observed excellent reproducibility between different instruments, underlining the robustness of the approach.  相似文献   

3.
Reproducibility among different types of excitation modes is a major bottleneck in the field of tandem mass spectrometry library development in metabolomics. In this study, we specifically evaluated the influence of collision voltage and activation time parameters on tandem mass spectrometry spectra for various excitation modes [collision‐induced dissociation (CID), pulsed Q dissociation (PQD) and higher‐energy collision dissociation (HCD)] of Orbitrap‐based instruments. For this purpose, internal energy deposition was probed using an approach based on Rice–Rampserger–Kassel–Marcus modeling with three thermometer compounds of different degree of freedom (69, 228 and 420) and a thermal model. This model treats consecutively the activation and decomposition steps, and the survival precursor ion populations are characterized by truncated Maxwell–Boltzmann internal energy distributions. This study demonstrates that the activation time has a significant impact on MS/MS spectra using the CID and PQD modes. The proposed model seems suitable to describe the multiple collision regime in the PQD and HCD modes. Linear relationships between mean internal energy and collision voltage are shown for the latter modes and the three thermometer molecules. These results suggest that a calibration based on the collision voltage should provide reproducible for PQD, HCD to be compared with CID in tandem in space instruments. However, an important signal loss is observed in PQD excitation mode whatever the mass of the studied compounds, which may affect not only parent ions but also fragment ions depending on the fragmentation parameters. A calibration approach for the CID mode based on the variation of activation time parameter is more appropriate than one based on collision voltage. In fact, the activation time parameter in CID induces a modification of the collisional regime and thus helps control the orientation of the fragmentation pathways (competitive or consecutive dissociations). Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

4.
Electron transfer dissociation (ETD) has become increasingly used in proteomic analyses due to its complementarity to collision-activated dissociation (CAD) and its ability to sequence peptides with post-translation modifications (PTMs). It was previously unknown, however, whether ETD would be compatible with a commonly employed quantification technique, isobaric tags for relative and absolute quantification (iTRAQ), since the fragmentation mechanisms and pathways of ETD differ significantly from CAD. We demonstrate here that ETD of iTRAQ labeled peptides produces c- and z -type fragment ions as well as reporter ions that are unique from those produced by CAD. Exact molecular formulas of product ions were determined by ETD fragmentation of iTRAQ-labeled synthetic peptides followed by high mass accuracy orbitrap mass analysis. These experiments revealed that ETD cleavage of the N-C(alpha) bond of the iTRAQ tag results in fragment ions that could be used for quantification. Synthetic peptide work demonstrates that these fragment ions provide up to three channels of quantification and that the quality is similar to that provided by beam-type CAD. Protein standards were used to evaluate peptide and protein quantification of iTRAQ labeling in conjunction with ETD, beam-type CAD, and pulsed Q dissociation (PQD) on a hybrid ion trap-orbitrap mass spectrometer. For reporter ion intensities above a certain threshold all three strategies provided reliable peptide quantification (average error < 10%). Approximately 36%, 8%, and 16% of scans identified fall below this threshold for ETD, HCD, and PQD, respectively. At the protein level, average errors were 2.3%, 1.7%, and 3.6% for ETD, HCD, and PQD, respectively.  相似文献   

5.
Isobaric peptide termini labeling (IPTL) is a quantification method which permits relative quantification using quantification points distributed throughout the whole tandem mass spectrometry (MS/MS) spectrum. It is based on the complementary derivatization of peptide termini with different isotopes resulting in isobaric peptides. Here, we use our recently developed software package IsobariQ to investigate how processing and data analysis parameters can improve IPTL data. Deisotoping provided cleaner MS/MS spectra and improved protein identification and quantification. Denoising should be used with caution because it may remove highly regulated ion pairs. An outlier detection algorithm on the ratios within every individual MS/MS spectrum was beneficial in removing false-positive quantification points. MS/MS spectra using IPTL typically contain two peptide series with complementary labels resulting in lower Mascot ion scores than non-labeled equivalent peptides. To avoid this penalty, the two chemical modifications for IPTL were specified as variables including satellite neutral losses of tetradeuterium with positive loss for the heavy isotopes and negative loss for the light isotopes. Thus, the less dominant complementary ion series were not considered for the scoring, which improved the ion scores significantly. In addition, we showed that IPTL was suitable for fragmentation by electron transfer dissociation (ETD) and higher energy collisionally activated dissociation (HCD) besides the already reported collision-induced dissociation (CID). Notably, ETD and HCD data can be identified and quantified using IsobariQ. ETD outperformed CID and HCD only for charge states ≥4+ but yielded in total fewer protein identifications and quantifications. In contrast, the high-resolution information of HCD fragmented peptides provided most identification and quantification results using the same scan speed.  相似文献   

6.
Quantitative proteomics has become an important method in modern life sciences. Besides protein identification, the aspect of quantification is of rapidly increasing relevance. MeCAT (metal‐coded affinity tagging) is able to provide a tool that enables relative as well as absolute quantification. For structural elucidation, knowledge on the fragmentation behavior of MeCAT‐modified peptides is highly beneficial. Therefore, the fragmentation behavior of MeCAT‐labeled peptides under collision induced dissociation (CID), electron capture dissociation (ECD) and infrared multiphoton dissociation (IRMPD) conditions was studied. Application of CID and ECD allowed a straight‐forward sequence elucidation of MeCAT‐labeled peptides. During IRMPD all MeCAT‐labeled peptides form characteristic fragments resulting from the fragmentational cleavage of the tagging group, thus, providing a screening method for the identification of labeled compounds. Furthermore, occurring side reactions during the labeling process were investigated. By‐products were structurally characterized and reaction conditions were optimized in order to prevent the formation of these. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
Benzylisoquinoline alkaloids (BIAs) have profound implications on human health owing to their potent pharmacological properties. Notable naturally occurring BIAs are the narcotic analgesics morphine, the cough suppressant codeine, the potential anticancer drug noscapine, the muscle relaxant papaverine, and the antimicrobial sanguinarine, all of which are produced in opium poppy (Papaver somniferum). Thebaine, an intermediate in the biosynthesis of codeine and morphine, is used in the manufacture of semisynthetic opiates, including oxycodone and naloxone. As the only commercial source of pharmaceutical opiates, opium poppy has been the focus of considerable research to understand BIA metabolism in the plant. The elucidation of several BIA biosynthetic pathways has enabled the development of synthetic biology platforms aimed at the alternative commercial production of valuable phytochemicals in microorganisms. The detection and identification of BIA pathway products and intermediates in complex extracts is essential for the continuing advancement of research in plant specialized metabolism and microbial synthetic biology. Herein, we report the use of liquid chromatography coupled with linear trap quadrupole and high‐resolution Orbitrap multistage mass spectrometry to characterize 44 authentic BIAs using collision‐induced dissociation (CID), higher‐energy collisional dissociation (HCD), and pulsed Q collision‐induced dissociation (PQD) MS2 fragmentation, with MS2 CID followed by MS3 and MS4 fragmentation. Our deep library of diagnostic spectral data constitutes a valuable resource for BIAs identification. In addition, we identified 22 BIAs in opium poppy latex and roots extracts.  相似文献   

8.
Our previous study showed that selenamide reagents such as ebselen and N-(phenylseleno)phthalimide (NPSP) can be used for selective and rapid derivatization of protein/peptide thiols in high conversion yield. This paper reports the systematic investigation of MS/MS dissociation behaviors of selenamide-derivatized peptide ions upon collision induced dissociation (CID) and electron transfer dissociation (ETD). In the positive ion mode, derivatized peptide ions exhibit tag-dependent CID dissociation pathways. For instance, ebselen-derivatized peptide ions preferentially undergo Se–S bond cleavage upon CID to produce a characteristic fragment ion, the protonated ebselen (m/z 276), which allows selective identification of thiol peptides from protein digest as well as selective detection of thiol proteins from protein mixture using precursor ion scan (PIS). In contrast, NPSP-derivatized peptide ions retain their phenylselenenyl tags during CID, which is useful in sequencing peptides and locating cysteine residues. In the negative ion CID mode, both types of tags are preferentially lost via the Se–S cleavage, analogous to the S–S bond cleavage during CID of disulfide-containing peptide anions. In consideration of the convenience in preparing selenamide-derivatized peptides and the similarity of Se–S of the tag to the S–S bond, we also examined ETD of the derivatized peptide ions to probe the mechanism for electron-based ion dissociation. Interestingly, facile cleavage of Se–S bond occurs to the peptide ions carrying either protons or alkali metal ions, while backbone cleavage to form c/z ions is severely inhibited. These results are in agreement with the Utah-Washington mechanism proposed for depicting electron-based ion dissociation processes.  相似文献   

9.
Deuterium isobaric Amine Reactive Tag (DiART) reagents facilitate relative quantification during proteomic analysis in a functionally similar manner to commercially available isobaric tag for relative and absolute quantitation (iTRAQ) and tandem mass tag (TMT) reagents. In contrast to iTRAQ and TMT, DiART reagents incorporate deuterium isotopes which significantly reduce the number of required synthesis steps and hence have potential to significantly reduce reagent production cost. We examined the capability of DiART for performing quantitative proteomic experiments using a linear ion‐trap mass spectrometer with Pulsed Q Dissociation (PQD) fragmentation. Using a synthetic peptide tagged with DiART reagent, we observed a precise mass shift of 144.79 Da on the triply charged precursor ion, which shows complete derivatization of the N‐terminus and ε‐amino group of lysine. A DiART tagged tryptic digest of bovine serum albumin showed a sequence coverage of 57.99% which was very comparable to that showed by iTRAQ, 54.77%. Furthermore, a ten protein mixture tagged with DiART reagents and mixed in 1:1:1:1:1:1 exhibited < 15% error, whereas a linear trend (slope of 1.085) was observed when tagged proteins were mixed in the ratio 2:1:2:4:10:14 and plotted against theoretical ratios. Finally, when complex cell‐wall protein mixtures from the model fungus A. nidulans were tagged with DiART reagents and mixed in different ratios, they exhibited similar trends. We conclude that DiART reagents are capable of performing quantitative proteomic experiments using PQD on a linear ion trap mass spectrometer. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
Recently, it has been shown that energy‐resolved mass spectrometry (MS) can provide quantitative information from two isomeric or isobaric compounds in mixtures by using the survival yield (SY) technique together with “gas‐phase collisional purification” (GPCP) strategy (Anal. Chem., 2016, 88, p.10821). Herein, we present an improvement and an extension of this concept to the structural analysis of a model mixture of three isobaric compounds (two peptides and a polyether). By using default collision‐induced dissociation (CID) tandem MS parameters on an ion trap instrument, the previous approach did not show any signs of isobaric contamination. However, by modifying CID conditions and using a threefold increase of the He trapping gas pressure (to reach 3.00·10?5 mbar), the SY curve was unexpectedly and strongly shifted to higher excitation voltages with two plateaus appearing. Those plateaus, indicating clearly the presence of three isobaric compounds, were taken as reliable indicators to perform GPCP at carefully selected excitation voltages in order to selectively fragment one compound after the other. In this way, CID mass spectra of each compound were correctly recovered, both in terms of fragment ion peaks and in terms of relative intensities, from energy‐resolved MSn spectra of the three compounds mixture. This feature enables their unequivocal structural analysis as if samples were free from isobaric interferences. In this paper, we also discuss the possibility for recovering SY curves for pure compounds directly from the mixture. Clearly, in this case, the higher He trapping gas pressure made it possible to use the SY technique, for the first time, for the structural analysis in the case of mixtures of three isobaric compounds. This observation, quite unexpected, demonstrates that the trapping gas pressure is of paramount importance although it is usually not considered in energy‐resolved MS for structural and/or quantitative analysis.  相似文献   

11.
Infrared multiphoton dissociation (IRMPD) on a linear ion trap mass spectrometer is applied for the sequencing of small interfering RNA (siRNA). Both single-strand siRNAs and duplex siRNA were characterized by IRMPD, and the results were compared with that obtained by traditional ion trap-based collision induced dissociation (CID). The single-strand siRNA anions were observed to dissociate via cleavage of the 5′ P—O bonds yielding c- and y-type product ions as well as undergo neutral base loss. Full sequence coverage of the siRNA anions was obtained by both IRMPD and CID. While the CID mass spectra were dominated by base loss ions, accounting for ∼25% to 40% of the product ion current, these ions were eliminated through secondary dissociation by increasing the irradiation time in the IRMPD mass spectra to produce higher abundances of informative sequence ions. With longer irradiation times, however, internal ions corresponding to cleavage of two 5′ P—O bonds began to populate the product ion mass spectra as well as higher abundances of [a − Base] and w-type ions. IRMPD of siRNA cations predominantly produced c- and y-type ions with minimal contributions of [a − Base] and w-type ions to the product ion current; the presence of only two complementary series of product ions in the IRMPD mass spectra simplified spectral interpretation. In addition, IRMPD produced high abundances of protonated nucleobases, [G + H]+, [A + H]+, and [C + H]+, which were not detected in the CID mass spectra due to the low-mass cut-off associated with conventional CID in ion traps. CID and IRMPD using short irradiation times of duplex siRNA resulted in strand separation, similar to the dissociation trends observed for duplex DNA. With longer irradiation times, however, the individual single-strands underwent secondary dissociation to yield informative sequence ions not obtained by CID.  相似文献   

12.
Recent advancements in mass spectrometry including data-dependent scanning and high-resolution mass spectrometry have aided metabolite profiling for non-radiolabeled xenobiotics. However, narrowing down a site of metabolism is often limited by the quality of the collision-induced dissociation (CID)-based precursor ion fragmentation. An alternative dissociation technique, higher energy collisional dissociation (HCD), enriches compound fragmentation and yields 'triple-quadrupole-like fragmentation'. Applying HCD along with CID and data-dependent scanning could enhance structural elucidation for small molecules. Liquid chromatography/multi-stage mass spectrometry (LC/MS(n) ) experiments with CID and HCD fragmentation were carried out for commercially available compounds on a hybrid linear ion trap orbital trap mass spectrometer equipped with accurate mass measurement capability. The developed method included stepped normalized collision energy (SNCE) parameters to enhance MS fragmentation without tuning for individual compounds. All the evaluated compounds demonstrated improved fragmentation under HCD as compared with CID. The results suggest that an LC/MS(n) method that incorporated both SNCE HCD- and CID-enabled precursor ion fragmentation afforded comprehensive structural information for the compounds under investigation. A dual collision cell approach was remarkably better than one with only CID MS(n) in an orbital trap. It is evident that such an acquisition method can augment the identification of unknown metabolites in drug discovery by improving fragmentation efficiency of both the parent compound and its putative metabolite(s).  相似文献   

13.
Means for effecting dipolar direct current collision-induced dissociation (DDC CID) on a quadrupole/time-of-flight in a mass spectrometer have been implemented for the broadband dissociation of a wide range of analyte ions. The DDC fragmentation method in electrodynamic storage and transmission devices provides a means for inducing fragmentation of ions over a large mass-to-charge range simultaneously. It can be effected within an ion storage step in a quadrupole collision cell that is operated as a linear ion trap or as ions are continuously transmitted through the collision cell. A DDC potential is applied across one pair of rods in the quadrupole collision cell of a QqTOF hybrid mass spectrometer to effect fragmentation. In this study, ions derived from a small drug molecule, a model peptide, a small protein, and an oligonucleotide were subjected to the DDC CID method in either an ion trapping or an ion transmission mode (or both). Several key experimental parameters that affect DDC CID results, such as time, voltage, low mass cutoff, and bath gas pressure, are illustrated with protonated leucine enkephalin. The DDC CID dissociation method gives a readily tunable, broadband tool for probing the primary structures of a wide range of analyte ions. The method provides an alternative to the narrow resonance conditions of conventional ion trap CID and it can access more extensive sequential fragmentation, depending upon conditions. The DDC CID approach constitutes a collision analog to infrared multiphoton dissociation (IRMPD).  相似文献   

14.
Unambiguous differentiation between isobaric sulfated and phosphorylated tyrosine residues (sTyr and pTyr) of proteins by mass spectrometry is challenging, even using high resolution mass spectrometers. Here we show that upon negative ion mode collision-induced dissociation (CID), pTyr- and sTyr-containing peptides exhibit entirely different modification-specific fragmentation patterns leading to a rapid discrimination between the isobaric covalent modifications using the tandem mass spectral data. This study reveals that the ratio between the relative abundances of [M-H-80](-) and [M-H-98](-) fragment ions in ion-trap CID and higher energy collision dissociation (HCD) spectra of singly deprotonated +80 Da Tyr-peptides can be used as a reliable indication of the Tyr modification group nature. For multiply deprotonated +80 Da Tyr-peptides, CID spectra of sTyr- and pTyr-containing sequences can be readily distinguished based on the presence/absence of the [M-nH-79]((n-1)-) and [M-nH-79-NL]((n-1)-) (n=2, 3) fragment ions (NL=neutral loss).  相似文献   

15.
For structural identification of glycans, the classic collision-induced dissociation (CID) spectra are dominated by product ions that derived from glycosidic cleavages, which provide only sequence information. The peaks from cross-ring fragmentation are often absent or have very low abundances in such spectra. Electron transfer dissociation (ETD) is being applied to structural identification of carbohydrates for the first time, and results in some new and detailed information for glycan structural studies. A series of linear milk sugars was analyzed by a variety of fragmentation techniques such as MS/MS by CID and ETD, and MS(3) by sequential CID/CID, CID/ETD, and ETD/CID. In CID spectra, the detected peaks were mainly generated via glycosidic cleavages. By comparison, ETD generated various types of abundant cross-ring cleavage ions. These complementary cross-ring cleavages clarified the different linkage types and branching patterns of the representative milk sugar samples. The utilization of different MS(3) techniques made it possible to verify initial assignments and to detect the presence of multiple components in isobaric peaks. Fragment ion structures and pathways could be proposed to facilitate the interpretation of carbohydrate ETD spectra, and the main mechanisms were investigated. ETD should contribute substantially to confident structural analysis of a wide variety of oligosaccharides.  相似文献   

16.
用质量分析离子动能谱(MIKES)研究了C~6F~6^+→C~6F~5^++F的气相单分子分解及其与Ar和He的碰撞诱导分解(CID)反应。实验结果表明,C~6F~6^+在电离室中获得足够能量而被激发到某一长效激发态,而CID是诱导其分解的必要步骤,且该分解过程有两条能量不同的反应途径。当碰撞气体为Ar时,两条途径所对应的能量变化分别为0eV和+9.8eV(将多余能量转化为动能),而当碰撞气体为He时,则分别为0eV和-17eV(将多余能量转化为内能)。CID/Ar诱导该长效激发态在C-F键断裂之前将多余能量转化为动能,而在CID/He中则将多余能量转化为内能。  相似文献   

17.
Ion activation methods for tandem mass spectrometry   总被引:7,自引:0,他引:7  
This tutorial presents the most common ion activation techniques employed in tandem mass spectrometry. In-source fragmentation and metastable ion decompositions, as well as the general theory of unimolecular dissociations of ions, are initially discussed. This is followed by tandem mass spectrometry, which implies that the activation of ions is distinct from the ionization step, and that the precursor and product ions are both characterized independently by their mass/charge ratios. In collision-induced dissociation (CID), activation of the selected ions occurs by collision(s) with neutral gas molecules in a collision cell. This experiment can be done at high (keV) collision energies, using tandem sector and time-of-flight instruments, or at low (eV range) energies, in tandem quadrupole and ion trapping instruments. It can be performed using either single or multiple collisions with a selected gas and each of these factors influences the distribution of internal energy that the activated ion will possess. While CID remains the most common ion activation technique employed in analytical laboratories today, several new methods have become increasingly useful for specific applications. More recent techniques are examined and their differences, advantages and disadvantages are described in comparison with CID. Collisional activation upon impact of precursor ions on solid surfaces, surface-induced dissociation (SID), is gaining importance as an alternative to gas targets and has been implemented in several different types of mass spectrometers. Furthermore, unique fragmentation mechanisms of multiply-charged species can be studied by electron-capture dissociation (ECD). The ECD technique has been recognized as an efficient means to study non-covalent interactions and to gain sequence information in proteomics applications. Trapping instruments, such as quadrupole ion traps and Fourier transform ion cyclotron resonance instruments, are particularly useful for the photoactivation of ions, specifically for fragmentation of precursor ions by infrared multiphoton dissociation (IRMPD). IRMPD is a non-selective activation method and usually yields rich fragmentation spectra. Lastly, blackbody infrared radiative dissociation is presented with a focus on determining activation energies and other important parameters for the characterization of fragmentation pathways. The individual methods are presented so as to facilitate the understanding of each mechanism of activation and their particular advantages and representative applications.  相似文献   

18.
A powerful and rapid method has been developed for the identification and quantitative determination of alkyl methylphosphonic acids, which are the degradation products of nerve agents, using liquid chromatography-time-of-flight mass spectrometry with electrospray ionization. Six alkyl methylphosphonic acids were well separated within 16 min. For quantitative analysis, good linearity, sensitivity and reproducibility were obtained by LC-MS in the selected ion monitoring mode. For unambiguous identification of alkyl methylphosphonic acids, fragment ions were produced by in-source collision induced dissociation (CID), and then exact mass measurement of CID fragment ions was performed. The feasibility of applying this technique for detecting these compounds in spiked environmental waters and soils was demonstrated.  相似文献   

19.
Surface-induced dissociation (SID) and collision-induced dissociation (CID) are ion activation techniques based on energetic collisions with a surface or gas molecule, respectively. One noticeable difference between CID and SID is that SID does not require a collision gas for ion activation and is, therefore, directly compatible with the high vacuum requirement of Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometers. Eliminating the introduction of collision gas into the ICR cell for collisional activation dramatically shortens the acquisition time for MS/MS experiments, suggesting that SID could be utilized for high-throughput MS/MS studies in FT-ICR MS. We demonstrate for the first time the utility of SID combined with FT-ICR MS for protein identification. Tryptic digests of standard proteins were analyzed using a hybrid 6-tesla FT-ICR mass spectrometer with SID and CID capabilities. SID spectra of mass-selected singly and doubly charged peptides were obtained using a diamond-coated target mounted at the rear trapping plate of the ICR cell. The broad internal energy distribution deposited into the precursor ion following collision with the diamond surface allowed a variety of fragmentation channels to be accessed by SID. Composition and sequence qualifiers produced by SID of tryptic peptides were used to improve the statistical significance of database searches. Protein identification MASCOT scores obtained using SID were comparable or better than scores obtained using sustained off-resonance irradiation collision-induced dissociation (SORI-CID), the conventional ion activation technique in FT-ICR MS.  相似文献   

20.
The fragmentation behavior of nitrated and S-nitrosylated peptides were studied using collision induced dissociation (CID) and metastable atom-activated dissociation mass spectrometry (MAD-MS). Various charge states, such as 1+, 2+, 3+, 2–, of modified and unmodified peptides were exposed to a beam of high kinetic energy helium (He) metastable atoms resulting in extensive backbone fragmentation with significant retention of the post-translation modifications (PTMs). Whereas the high electron affinity of the nitrotyrosine moiety quenches radical chemistry and fragmentation in electron capture dissociation (ECD) and electron transfer dissociation (ETD), MAD does produce numerous backbone cleavages in the vicinity of the modification. Fragment ions of nitrosylated cysteine modifications typically exhibit more abundant neutral losses than nitrated tyrosine modifications because of the extremely labile nature of the nitrosylated cysteine residues. However, compared with CID, MAD produced between 66% and 86% more fragment ions, which preserved the labile –NO modification. MAD was also able to differentiate I/L residues in the modified peptides. MAD is able to induce radical ion chemistry even in the presence of strong radical traps and therefore offers unique advantages to ECD, ETD, and CID for determination of PTMs such as nitrated and S-nitrosylated peptides.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号