首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Groundwater samples collected from a tannery contaminated area were analyzed for chromium species with the objective of investigating the interference of Cr(III)-organic complexes in the determination of Cr(VI) using APDC–MIBK extraction procedure. The contribution of Cr(III), Cr(VI) and Cr(III)-organic complexes towards total chromium ranged between 2 and 61%, 27 and 86%, and, 6 and 23%, respectively. The Cr(III)-organic complexes were not extractable by APDC–MIBK, however, HNO3 digestion released the organic bound Cr(III). Interference of organic bound Cr(III) in Cr(VI) determination due to MIBK soluble Cr(III) was not observed. Significant difference between total dissolved chromium determined after appropriate digestion procedure, and the sum of dissolved Cr(III) and Cr(VI) determined indicates the presence of the Cr(III)-organic complexes. MIBK extraction of samples without APDC is an useful way to check the extractability of organic bound Cr(III). The presence of soluble Cr(III)-organic complexes thus add complexity to chromium speciation analysis by APDC–MIBK procedure.  相似文献   

2.
In this work, different analytical speciation schemes have been used to study the reduction of Cr(VI) by a chromate-resistant strain of filamentous fungi Ed8 (Aspergillus sp), indigenous to contaminated industrial wastes. As demonstrated previously, this strain has the capability to reduce chromate present in the growth medium without its accumulation in the biomass, yet the reduced chromium end-products have not been characterized. Liquid growth medium, initially containing 50 mg L(-1) Cr(VI), was analyzed for Cr(III)/Cr(VI) and for total Cr at different time intervals (0-24 h) after inoculation with fungi. Three hyphenated procedures, based on the Cr(III)-EDTA formation and species separation by anion-exchange or ion-pairing reversed-phase chromatography with ICP-MS or DAD detection were used. The results obtained for Cr(VI) in each case were consistent, demonstrating efficient reduction of chromate during 24 h of Ed8 growth. However, pre-column complexation with EDTA did not ensure complete recovery of the reduced forms of chromium in the above procedures. An alternative speciation scheme, based on extraction of Cr(VI)-benzyltributylammonium bromide (BTAB) ion pairs into chloroform and subsequent determination of residual chromium by ICP-MS has provided evidence on the effective conversion of chromate into reduced chromium species in the growth medium. The results indicate the feasibility of using Ed8 strain for chromate bioremediation purposes. Analytically it can be concluded that speciation of chromium in biological systems should not be limited to its two most common oxidation states, because the actual reduced chromium species are not converted quantitatively to Cr(III)-EDTA.  相似文献   

3.
In this article, the contents and distribution of total chromium, Cr(III) and Cr(VI) in various cigarettes and cigarette ashes were determined by using a cloud point extraction (CPE) separation/preconcentration combined with graphite furnace atomic absorption spectrometric (GFAAS) detection. Different extraction reagents, such as tetramethylammonium hydroxide (TMAH), Na2HPO4, Na2CO3/NaOH, NaOH and H2O, were tested for the extraction of Cr species, and the extraction efficiency was estimated. The experimental results showed that TMAH was the most efficient extraction reagent for the analyte in cigarette samples. By using the established method, the total chromium, Cr(III) and Cr(VI) in various cigarettes and cigarette ashes were determined and their distribution was studied. It was found that Cr(III) is a main species in cigarettes, but that it can be partly oxidized to Cr(VI) during smoking.  相似文献   

4.
A new solid phase extraction (SPE) method has been developed for the speciation of Cr(III) and Cr(VI). This method is based on the adsorption of Cr(VI) on modified alumina‐coated magnetite nanoparticles (ACMNPs). Total chromium in different samples was determined as Cr(VI) after oxidation of Cr(III) to Cr(VI) using H2O2. The chromium concentration has been determined by flame atomic absorption spectrometric (FAAS) technique and amount of Cr(III) was calculated by substracting the concentration of Cr(VI) from total chromium concentration. The effect of parameters such as pH, amount of adsorbent, contact time, sample volume, eluent type, H2O2 concentration and cetyltrimethylammonium bromide (CTAB) concentration as modifier on the quantitative recovery of Cr(VI) were investigated. Under the optimal experimental conditions, the preconcentration factor, detection limit, linear range and relative standard deviation (RSD) of Cr(VI) were 140 (for 350 mL of sample solution), 0.083 ng mL?1, 0.1‐10.0 ng mL?1 and 4.6% (for 5.0 ng mL?1, n = 7), respectively. This method avoided the time‐consuming column‐passing process of loading large volume samples in traditional SPE through the rapid isolation of CTAB@ACMNPs with an adscititious magnet. The proposed method was successfully applied to the determination and speciation of chromium in different water and wastewater samples and suitable recoveries were obtained.  相似文献   

5.
Diperoxo chromium oxide is produced by reaction of hydrogen peroxide on chromium(VI). Diperoxo chromium creates a complex with ethyl acetate, while chromium(III) remains in an unchanged form in the aqueous phase. By this means chromium(VI) can be extracted into ethyl acetate from the aqueous phase. The optimal conditions of Cr(III)-Cr(VI) separation, as well as the chromium content of the ethyl acetate phase were determined with graphite furnace atomic absorption spectrometry. In the second extraction of Cr(VI) from ethyl acetate back into water phase an additional preconcentration of chromium(VI) can be carried out. The detection limit (3σ) of the developed method found to be 200 ng dm− 3 for the first extraction and 50 ng dm− 3 after using the twofold extraction. In consequence of the matrix free ethyl acetate phase after the first extraction, with this separation a really extensive preconcentration of chromium(VI) can be realized.  相似文献   

6.
A European directive was recently adopted limiting the use of hazardous substances such as Pb, Hg, Cd, and Cr(VI) in vehicle manufacturing. From July 2003 a maximum of 2 g Cr(VI) will be authorised per vehicle in corrosion-preventing coatings of key components. As no standardised procedures are available to check if produced vehicles are in agreement with this directive, the objective of this work was to develop analytical procedures for total chromium and Cr(VI) determination in these materials. The first step of this study was to optimise digestion procedures for total chromium determination in plastic and metallic materials by inductively coupled plasma mass spectrometry (ICP–MS). High resolution (HR) ICP–MS was used to examine the influence of polyatomic interferences on the detection of the 52Cr+ and 53Cr+ isotopes. If there was strong interference with m/z 52 for plastic materials, it was possible to use quadrupole ICP–MS for m/z 53 if digestions were performed with HNO3+H2O2. This mixture was also necessary for digestion of chromium from metallic materials. Extraction procedures in alkaline medium (NH4+/NH3 buffer solution at pH 8.9) assisted by sonication were developed for determining Cr(VI) in four different corrosion-preventing coatings by HPLC–ICP–MS. After optimisation and validation with the only solid reference material certified for its Cr(VI) content (BCR 545; welding dusts), the efficiency of this extraction procedure for screw coatings was compared with that described in the EN ISO 3613 standard generally used in routine laboratories. For coatings comprising zinc and aluminium passivated in depth with chromium oxides the extraction procedure developed herein enabled determination of higher Cr(VI) concentrations. This was also observed for the screw covered with a chromium passivant layer on zinc–nickel. For coating comprising a chromium passivant layer on alkaline zinc the standardized extraction procedure was more efficient. In the case of painted metallic plate, because of a reactive matrix towards Cr(VI), its extraction without degradation was difficult to perform.  相似文献   

7.
A simple speciation, separation and enrichment method has been developed for the determination of Cr(III) and Cr(VI) ions in different samples by ion-pair solvent extraction with a β-diketone ligand, 2-(4-methoxybenzoyl)-N′-benzylidene-3-(4-methoxyphenyl)-3-oxo-N-phenyl-propono hydrazide (MBMP). Cr(III) was separated from Cr(VI) as Cr(III)-(MBMP)-perchlorate ternary ion-pair complex. The influences of various analytical parameters including pH, amount of reagent, shaking time, sample volume and ionic strength on the recovery of Cr(III) and/or Cr(VI) were investigated. Total chromium was obtained after reducing Cr(VI) to Cr(III) with NH2OH?·?HCl. Recoveries were found to be higher than 95% and the relative standard deviation (RSD) was less than 2%. The method detection limit based on 3σ criterion for Cr(III) was found to be 0.32?µg?L?1. The formed ternary ion-pair complex, Cr(III)?:?MBMP?:?2ClO4, has a molar ratio of 1?:?1?:?2. The developed method has been applied successfully to the speciation of chromium in various natural water, soil, sediment and hair samples with satisfactory results.  相似文献   

8.
《Analytical letters》2012,45(4):809-822
Abstract

A new method based on cloud point extraction (CPE) separation and electrothermal vaporization inductively coupled plasma optical emission spectrometry (ETV‐ICP‐OES) detection was proposed for the determination of chromium species. Thenoyltrifluoracetone (TTA) was used as both an extractant for CPE of Cr(III) and a chemical modifier for ETV‐ICP‐OES determination. When the system temperature is higher than the cloud point temperature (CPT) of the selected surfactant, Triton X‐114, the complex of Cr(III) with TTA could enter the surfactant‐rich phase, whereas the Cr(VI) remained in aqueous solutions. Thus, an in situ separation of Cr(III) and Cr(VI) could be realized. The concentrated analyte was introduced into ETV‐ICP‐OES for determination of Cr(III) after proper disposal. Cr(VI) is reduced to Cr(III) prior to determining total Cr, and its assay is based on substracting of Cr(III) from total chromium. The main factors affecting cloud point extraction and the vaporization behavior of the analyte were investigated in detail. Under the optimized conditions, the limit of detection (LOD) for Cr(III) was 0.22 µg/L by preconcentration of a 10 mL sample solution, and the relative standard deviation (RSD) was 3.8% (CCr(III)=0.5 µg/mL, n=5). The proposed method was applied to the speciation of chromium in different water samples. In order to verify the accuracy of the method, a certified reference water sample was analyzed, and the results obtained were in good agreement with certified values.  相似文献   

9.
Hagendorfer H  Goessler W 《Talanta》2008,76(3):656-661
Due to its extensive use in industrial processes, large quantities of chromium compounds are discharged into the environment. Common approaches for the speciation of Cr employ the determination of Cr(VI) and total Cr. The focus of the present work was a separation of Cr(III) and Cr(VI) species, with a minimum of sample preparation, by keeping an eye on the more relevant and toxic Cr(VI). For the successful simultaneous separation of both chromium species we implemented a RSpak NN-814 4DP (PEEK, 4 mm x 150 mm) multi-mode column using an eluent containing 90 mM ammonium sulfate and 10 mM ammonium nitrate, adjusted to pH 3.5. At a flow of 0.3 mL min(-1) the separation of both Cr species was possible within 8 min. Further the octopole reaction system of the inductively coupled plasma mass spectrometer was systematically studied and optimised to reduce the influence of polyatomic interferences. The major advantage of the developed method compared to published methods is that a derivatisation of the Cr(III) species--an invasion in the speciation--is not required. With the used multi-mode column both chromium species are retained. Furthermore the pH of the mobile phase (pH 3.5) prevents reduction of Cr(VI) as well as precipitation of Cr(III) during the analysis. A limit of determination of approximately 0.5 microg L(-1) for both chromium species with an injection volume of 25 microL was obtained. The optimised method was successfully applied to the determination of Cr(VI) in cement samples as well as chromium speciation analysis in homeopathic drugs.  相似文献   

10.
Chromium has been determined by isotope dilution in artificial standards and in standard alloys using the substoichiometric principle. As a substoichiometric reaction the reduction of Cr(VI) to Cr(III) was used, followed by separation of these species by coprecipitation of the trivalent chromium on a Ti(OH)4 precipitate. For amounts smaller than 1 μg the standard method had to be modified owing to spontaneous reduction of hexavalent chromium in the solution. Interferences from other metals, if they occur, can be easily overcome. The method is simple and inexpensive.  相似文献   

11.
A simple, inexpensive method based on solid-phase extraction (SPE) on sawdust from Cedrus deodera has been developed for speciation of Cr(III) and Cr(VI) in environmental water samples. Because different exchange capacities were observed for the two forms of chromium at different pH—Cr(III) was selectively retained at pH 3 to 4 whereas Cr(VI) was retained at pH 1—complete separation of the two forms of chromium is possible. Retained species were eluted with 2.5 mL 0.1 mol L−1 HCl and 0.1 mol L−1 NaOH. Detection limits of 0.05 and 0.04 μg mL−1 were achieved for Cr(III) and Cr(VI), respectively, with enrichment factors of 100 and 80. Recovery was quantitative using 250 mL sample volume for Cr(III) and 200 mL for Cr(VI). Different kinetic and thermodynamic properties that affect sorption of the chromium species on the sawdust were also determined. Metal ion concentration was measured as the Cr(VI)–diphenylcarbazide complex by UV–visible spectroscopy. The method was successfully applied for speciation of chromium in environmental and industrial water samples.  相似文献   

12.
Yu R  Hu Z  Ye M  Che J 《色谱》2012,30(4):409-413
建立了采用快速溶剂萃取-离子色谱同时测定塑料中三价铬和六价铬的方法。三价铬和六价铬分别以吡啶-2,6-二羧酸(PDCA)和1,5-二苯卡巴肼(DPC)作为络合剂在柱前和柱后进行衍生化,分别在紫外和可见波长下采用紫外检测器进行检测,灵敏度高,基体干扰小。本方法对三价铬和六价铬的检出限分别为5.0 μg/L和0.5 μg/L;分别在50~1000 μg/L和5.0~100 μg/L范围内呈现良好的线性关系,线性相关系数分别为0.9994和0.9998;三价铬和六价铬的回收率范围为90.7%~101.1%,相对标准偏差(RSD)为1.7%~4.4%。该方法分析速度快、灵敏度高、重现性好,可用于塑料中三价铬和六价铬的同时测定。  相似文献   

13.
Hexavalent chromium, a major contaminant in most wastewater sites, is a potential health threat inducing cancer to humans while trivalent chromium is an essential element for the metabolism of sugar. The radiation-induced reduction of Cr(VI) metal ion to Cr(III) by the perhydroxyl radical (HO2 ?) and carboxyl radical anion (CO2 ??) produced by continuous radiolysis of water was investigated by steady state radiolysis of O2, Ar and N2O-saturated pH 3 solutions in the presence of formate. In all cases the removed Cr(VI) was a linear function of the absorbed dose. The added formate was favorable for removing Cr(VI). Its presence protects the solution from reverse radiolytic oxidation of Cr(III) to Cr(VI). The measured and calculated yield of removal of Cr(VI) do agree quite well at low formate concentration but at high formate concentration the measured yield was higher than the expected. When all formate is exhausted no recovery of Cr(VI) from Cr(III) was observed in case of O2- and Ar-saturated solutions whilst in the case of N2O-saturated solutions Cr(VI) recovers. The results obtained in this study highlight the potential of this technology for industrial wastewater treatment.  相似文献   

14.
 An isotope dilution mass spectrometric (IDMS) method, using the formation of positive thermal ions, was developed for Cr(III) and Cr(VI) speciation in aerosol particles. Cr(III) and Cr(VI) spike species, enriched in 53Cr, were applied for the isotope dilution step. After leaching of filter collected aerosol samples by an alkaline solution at pH 13, species separation was carried out by extraction with a liquid anion exchanger in methyl isobutyl ketone. Cr(VI) in the organic phase was re-extracted into an ammoniacal solution and chromium was then isolated from both fractions of species by electrodeposition. Detection limits of 30 pg/m3 for Cr(III) and of 8 pg/m3 for Cr(VI) were achieved in atmospheric aerosols for volumes of air samples of about 120 m3. These low detection limits allowed the determination of chromium species in continental aerosol particles in dependence on different seasons. The Cr(III) /Cr(VI) ratio was always found to be about 0.3 whereas dust from soil erosion, which is probably the primary source of chromium in the atmosphere, showed higher ratios. This indicates that chromium is oxidized in the atmosphere. The accuracy of the method was demonstrated in two interlaboratory comparisons of Cr(VI) determinations in welding dust samples. The IDMS method also contributed to the certification of a corresponding standard reference material organized by the Standard Reference Bureau of the European Union. Chromium speciation, including the determination of elemental chromium Cr(0), was carried out in aerosols of different welding processes for stainless steel. These analyses showed distinct differences in the distribution of chromium species in the welding process and can be used as an exact calibration method for routine methods in this important field of monitoring corresponding working places. Received: 19 August 1996/Revised: 24 September 1996/Accepted: 28 September 1996  相似文献   

15.
In this approach a fluorometric technique has been developed to study chromium speciation, based on optimised conditions using chemometric methods of experimental design and central composite design. Full and fractional factorial design was used for evaluation of the effective factors in determination of Cr(VI) by fluorometric using Rhodamine-6G in the presence of H2SO4. Theory and methodology of a central composite design as a chemometric method for the optimisation of analytical procedures were developed in this approach. It was found that the analytical performance for measurement at the point of optimum in this technique is superior and more accurate than that of one variable at a time. Cr(VI) and Cr(III) were measured in a wastewater sample using the proposed technique. The results confirm the selective determination and speciation of Cr(VI)/Cr(III).  相似文献   

16.
A novel type of solvent named deep eutectic solvent (DES) has been considered as a green ionic liquid analogue. A novel method was developed for enrichment and speciation of chromium ion from water and food samples based on deep eutectic solvent and ultrasonic extraction. The procedure for this method was comprised of Cr(III) complex formation with a hydrophobic complexing agent (Z)‐N‐(3,5‐diphenyl‐1H‐pyrrol‐2‐yl)‐3,5‐diphenyl‐2H‐pyrrol‐2‐imine (azadipyrromethene dye). Metal complex was entrapped in a deep eutectic solvent as an extracting solvent. While Cr(III) recovery was quantitative, the recovery of Cr(VI) was found 5%. After reduction of Cr(VI) to Cr(III), the method was applied for determination of total chromium(III) ion. The amount of Cr(VI) was calculated as subtracting of Cr(III) from total chromium ion. Various analytical parameters were optimized. The certified reference materials were analyzed and standard addition method also carried out to real samples to check the accuracy of the developed method. Preconcentration factor was found to be 50. The limit of detection of chromium(III) was found to be 4.3 ng l‐1. The precision of developed method as the relative standard deviation (RSD) was found as 3.5 %. The developed method was applied successfully for the speciation of chromium ions in water and food samples.  相似文献   

17.
A highly sensitive, selective and simple kinetic method was developed for the determination of dissolved chromium species based on the catalytic effect of Cr(III) and/or Cr(VI) on the oxidation of 2-amino-5-methylphenol (AMP) with H2O2. The fixed time and initial rate variants were used for kinetic spectrophotometric measurements by tracing the oxidized product at 400 nm for 10 min after starting the reaction. Boric acid and Tween-40 exerted pronounced activating and micellar sensitizing effects on the studied redox reaction, respectively. The optimum reaction conditions were: 3.0 mmol l−1 AMP, 0.45 mol l−1 H2O2, 0.50 mol l−1 boric acid, 4 v/v% Tween-40, 10 mmol l−1 phosphate buffer and pH 6.45 ± 0.02 at 35 °C. Both Cr(III) and Cr(VI) ions exerted the same catalytic effect on the studied reaction. Linear calibration graphs were obtained for the determination of up to 6.0 ng ml−1 Cr with detection limits of 0.054 and 0.10 ng ml−1 Cr; following the fixed time and initial rate methods, respectively. The proposed method was successfully applied to the speciation and determination of trace levels of dissolved Cr(III) and Cr(VI) in natural and effluents of industrial waste water. The total dissolved Cr(III) and Cr(VI) species was determined first. In a second run, Cr(VI) was determined alone after precipitation of Cr(III) ions in presence of Al(OH)3 collector, where Cr(III) is then determined by difference. Moreover, published catalytic-spectrophotometric methods for chromium determination were reviewed.  相似文献   

18.
Conversion of hexavalent chromium (Cr(Ⅵ)) to trivalent chromium (Cr(Ⅲ)) is an effective way to reduce its environmental risk,especially via photoreduction process.However,over a wide range of p H values,it is still a great challenge to achieve a high removal rate,and the disposal of produced Cr(Ⅲ) should be concerned.In this work,we implemented a high removal rate at 98%for Cr(Ⅵ) and total chromium(Cr(T)) over a wide p H range (4–10) through the synergistic effect of adsorption,photoreduction an...  相似文献   

19.
A method for speciation of Cr(III) and Cr(VI) in real samples has been developed. Cr(VI) has been separated from Cr(III) and preconcentrated as its pyrrolidinedithiocarbamate (APDC) complex by using a column containing Amberlite XAD–2000 resin and determined by FAAS. Total chromium has also been determined by FAAS after conversion of Cr(III) to Cr(VI) by oxidation with KMnO4. Cr(III) has been calculated by subtracting Cr(VI) from the total. The effect of pH, flow‐rate, adsorption and batch capacity and effect of various metal cations and salt anions on the sorption onto the resin were investigated. The adsorption is quantitative in the pH range of 1.5–2.5, and Cr(VI) ion was desorbed by using H2SO4 in acetone. The recovery of Cr(VI) was 97 ± 4 at a 95% confidence level. The highest preconcentration factor was 80 for a 200 mL sample volume. The adsorption and batch capacity of sorbent were 7.4 and 8.0 mg g?1 Cr(VI), respectively, and loading half time was 5.0 min. The detection limit of Cr(VI) is 0.6 μg/L. The procedure has been applied to the determination and speciation of chromium in stream water, tap water, mineral spring water and spring water. Also, the proposed method was applied to total chromium preconcentration in microwave digested moss and rock samples with satisfactory results. The developed method was validated with CRM‐TMDW‐500 (Certified Reference Material Trace Metals in Drinking Water) and BCR‐CRM 144R s (Certified Reference Material Sewage Sludge, Domestic Origin) and the results obtained were in good agreement with the certified values. The relative standard deviations were below 6%.  相似文献   

20.
A sensitive and simple method for determination of chromium species after separation and preconcentration by solid phase extraction (SPE) has been developed. For the determination of the total concentration of chromium in solution, Cr(VI) was efficiently reduced to Cr(III) by addition of hydroxylamine and Cr(III) was preconcentrated on a column of immobilised ferron on alumina. The adsorbed analyte was then eluted with 5?mL of hydrochloric acid and was determined by flame atomic absorption spectrometery. The speciation of chromium was affected by first passing the solution through an acidic alumina column which retained Cr(VI) and then Cr(III) was preconcentrated by immobilised ferron column and determined by FAAS. The concentration of Cr(VI) was determined from the difference of concentration of total chromium and Cr(III). The effect of pH, concentration of eluent, flow rate of sample and eluent solution, and foreign ions on the sorption of chromium (III) by immobilised ferron column was investigated. Under the optimised conditions the calibration curve was linear over the range of 2–400?µg?L?1 for 1000?mL preconcentration volume. The detection limit was 0.32?µg?L?1, the preconcentration factor was 400, and the relative standard deviation (%RSD) was 1.9% (at 10?µg?L?1; n?=?7). The method was successfully applied to the determination of chromium species in water samples and total chromium in standard alloys.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号