首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 546 毫秒
1.
同位素质谱和无机质谱   总被引:2,自引:0,他引:2  
赵墨田 《分析试验室》1997,16(1):92-100
本文是《分析试验室》定期评述中“同位素质谱和无机质谱”的第四篇评述,评述的范围是1994年11月至1996年10月我国气体同位素质谱,热电离同位素质谱,加速器质谱,火花源质谱,电感耦合等离子体质谱,辉光放电质谱,同位素稀释质谱,二次离子质谱,激光共振电离子飞行时间质谱,电子探针,质子探针,激光探针和它们在地学,核科学,环境科学,材料学,计理学,医学和生命科学中的应用,引用文献149篇。  相似文献   

2.
The design of functional interfaces is central to both fundamental and applied research in materials science and energy technology. We introduce a new, broadly applicable technique for the precisely controlled high-throughput preparation of well-defined interfaces containing polyatomic species ranging from small ions to nanocrystals and large protein complexes. The mass-dispersive deposition of ions onto surfaces is achieved using a rotating-wall mass analyzer, a compact device which enables the separation of ions using low voltages and has a theoretically unlimited mass range. We demonstrate an efficient deposition of singly charged Au144(SC4H9)60 ions (33.7 kDa), which opens up exciting opportunities for the structural characterization of nanocrystals and their assemblies using transmission electron microscopy. Our approach also enables the high-throughput deposition of mass-selected ions from multicomponent mixtures, which is of interest to the controlled preparation of surface gradients and rapid screening of molecules in mixtures for a specific property.  相似文献   

3.
Over the last two decades, native mass spectrometry (MS) has emerged as a valuable tool to study intact proteins and noncovalent protein complexes. Studied experimental systems range from small-molecule (drug)–protein interactions, to nanomachineries such as the proteasome and ribosome, to even virus assembly. In native MS, ions attain high m/z values, requiring special mass analyzers for their detection. Depending on the particular mass analyzer used, instrumental mass resolution does often decrease at higher m/z but can still be above a couple of thousand at m/z 5000. However, the mass resolving power obtained on charge states of protein complexes in this m/z region is experimentally found to remain well below the inherent instrument resolution of the mass analyzers employed. Here, we inquire into reasons for this discrepancy and ask how native MS would benefit from higher instrumental mass resolution. To answer this question, we discuss advantages and shortcomings of mass analyzers used to study intact biomolecules and biomolecular complexes in their native state, and we review which other factors determine mass resolving power in native MS analyses. Recent examples from the literature are given to illustrate the current status and limitations.
Figure
?  相似文献   

4.
5.
6.
7.
8.
9.
Mass defect is associated with the binding energy of the nucleus. It is a fundamental property of the nucleus and the principle behind nuclear energy. Mass defect has also entered into the mass spectrometry terminology with the availability of high resolution mass spectrometry and has found application in mass spectral analysis. In this application, isobaric masses are differentiated and identified by their mass defect. What is the relationship between nuclear mass defect and mass defect used in mass spectral analysis, and are they the same?
Graphical Abstract ?
  相似文献   

10.
Amyloid fibrils are self‐assembled protein structures with important roles in biology (either pathogenic or physiological), and are attracting increasing interest in nanotechnology. However, because of their high aspect ratio and the presence of some polymorphism, that is, the possibility to adopt various structures, their characterization is challenging and basic information such as their mass is unknown. Here we show that charge‐detection mass spectrometry, recently developed for large self‐assembled systems such as viruses, provides such information in a straightforward manner.  相似文献   

11.
Fourier transform ion cyclotron resonance (FTICR) mass spectrometry provides unparalleled mass measurement accuracy and resolving power. However, propagation of the technique into new analytical fields requires continued advances in instrument speed and sensitivity. Here, we describe a substantial redesign of our custom-built 9.4 tesla FTICR mass spectrometer that improves sensitivity, acquisition speed, and provides an optimized platform for future instrumentation development. The instrument was designed around custom vacuum chambers for improved ion optical alignment, minimized distance from the external ion trap to magnetic field center, and high conductance for effective differential pumping. The length of the transfer optics is 30% shorter than the prior system, for reduced time-of-flight mass discrimination and increased ion transmission and trapping efficiency at the ICR cell. The ICR cell, electrical vacuum feedthroughs, and cabling have been improved to reduce the detection circuit capacitance (and improve detection sensitivity) 2-fold. The design simplifies access to the ICR cell, and the modular vacuum flange accommodates new ICR cell technology, including linearized excitation, high surface area detection, and tunable electrostatic trapping potential.  相似文献   

12.
Mass accuracy is a key parameter in proteomic experiments, improving specificity, and success rates of peptide identification. Advances in instrumentation now make it possible to routinely obtain high resolution data in proteomic experiments. To compensate for drifts in instrument calibration, a compound of known mass is often employed. This ‘lock mass’ provides an internal mass standard in every spectrum. Here we take advantage of the complexity of typical peptide mixtures in proteomics to eliminate the requirement for a physical lock mass. We find that mass scale drift is primarily a function of the m/z and the elution time dimensions. Using a subset of high confidence peptide identifications from a first pass database search, which effectively substitute for the lock mass, we set up a global mathematical minimization problem. We perform a simultaneous fit in two dimensions using a function whose parameterization is automatically adjusted to the complexity of the analyzed peptide mixture. Mass deviation of the high confidence peptides from their calculated values is then minimized globally as a function of both m/z value and elution time. The resulting recalibration function performs equal or better than adding a lock mass from laboratory air to LTQ-Orbitrap spectra. This ‘software lock mass’ drastically improves mass accuracy compared with mass measurement without lock mass (up to 10-fold), with none of the experimental cost of a physical lock mass, and it integrated into the freely available MaxQuant analysis pipeline ().  相似文献   

13.
Mass spectrometry imaging by Fourier transform ion cyclotron resonance (FT-ICR) yields hundreds of unique peaks, many of which cannot be resolved by lower performance mass spectrometers. The high mass accuracy and high mass resolving power allow confident identification of small molecules and lipids directly from biological tissue sections. Here, calibration strategies for FT-ICR MS imaging were investigated. Sub-parts-per-million mass accuracy is demonstrated over an entire tissue section. Ion abundance fluctuations are corrected by addition of total and relative ion abundances for a root-mean-square error of 0.158?ppm on 16,764 peaks. A new approach for visualization of FT-ICR MS imaging data at high resolution is presented. The ??Mosaic Datacube?? provides a flexible means to visualize the entire mass range at a mass spectral bin width of 0.001?Da. The high resolution Mosaic Datacube resolves spectral features not visible at lower bin widths, while retaining the high mass accuracy from the calibration methods discussed.  相似文献   

14.
15.
16.
17.
本文与本刊1991年专栏评述衔接,评述了1991~1992年10月间我国同位素质谱和无机质谱分析的情况。包括同位素分析、同位素示踪、同位位素稀释、同位素质谱计研制、火花质谱、二次离子质谱、离子探针、等离子体质谱等。资料来源以国内为主,也收集了少量代表学科先进水平的外国文献。参考文献252篇。  相似文献   

18.
Profiling and imaging biological specimens using MALDI mass spectrometry has significant potential to contribute to our understanding and diagnosis of disease. The technique is efficient and high-throughput providing a wealth of data about the biological state of the sample from a very simple and direct experiment. However, in order for these techniques to be put to use for clinical purposes, the approaches used to process and analyze the data must improve. This study examines some of the existing tools to baseline subtract, normalize, align, and remove spectral noise for MALDI data, comparing the advantages of each. A preferred workflow is presented that can be easily implemented for data in ASCII format. The advantages of using such an approach are discussed for both molecular profiling and imaging mass spectrometry.  相似文献   

19.
The design of functional interfaces is central to both fundamental and applied research in materials science and energy technology. We introduce a new, broadly applicable technique for the precisely controlled high‐throughput preparation of well‐defined interfaces containing polyatomic species ranging from small ions to nanocrystals and large protein complexes. The mass‐dispersive deposition of ions onto surfaces is achieved using a rotating‐wall mass analyzer, a compact device which enables the separation of ions using low voltages and has a theoretically unlimited mass range. We demonstrate an efficient deposition of singly charged Au144(SC4H9)60 ions (33.7 kDa), which opens up exciting opportunities for the structural characterization of nanocrystals and their assemblies using transmission electron microscopy. Our approach also enables the high‐throughput deposition of mass‐selected ions from multicomponent mixtures, which is of interest to the controlled preparation of surface gradients and rapid screening of molecules in mixtures for a specific property.  相似文献   

20.
本文应用聚乙二醇400(PEG400)作内标,通过电喷雾-飞行时间质谱测定5个氨基醇类化合物及衍生物的准确质量,并考察了锥孔电压、锥孔温度等因素对准确质量测定的影响.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号