首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Specific allergen immunotherapy is frequently associated with adverse reactions. Several strategies are being developed to reduce the allergenicity while maintaining the therapeutic benefits. Peptide immunotherapy is one such approach. Methods for the simple and rapid identification of immunogenic epitopes of allergens (i.e. allergenic epitopes) are ongoing and could potentially lead to peptide-based vaccines. An epitope extraction technique, based on biofunctionalized magnetic microspheres self-organized under a magnetic field in a channel of a simple microfluidic device fabricated from polydimethylsiloxane, was applied in the isolation and identification of prospective allergenic epitopes. Similarly to chromatographic column separations, the easily replaceable plug of self-organized beads in the channel benefits especially from an even larger surface-to-volume ratio and an enhanced interaction of the surfaces with passing samples. Ovalbumin, the major protein of egg white and a typical representative of food allergens, was selected as the model molecule. Highly resistant ovalbumin was at first efficiently digested by a magnetic proteolytic reactor with trypsin treated with l-1-tosylamido-2-phenylethyl chloromethyl ketone and the second step, i.e. capture of allergenic epitopes from the mixture of peptides, was performed by a magnetic immunoaffinity carrier with orientedly immobilized rabbit anti-ovalbumin IgG molecules. Captured peptides were released with 0.05% trifluoroacetic acid. The elution fractions were analyzed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. The peptide fragment of ovalbumin HIATNAVLFFGR (m/z: 1345.75, position: 371-382) was identified as a relevant allergenic epitope in this way. Such a microfluidic magnetic force-based epitope extraction technique applied in the epitope mapping of ovalbumin has the potential to be a significant step towards developing safe and cost-effective epitope-based vaccines.  相似文献   

2.
An immunoaffinity chromatography extraction capillary liquid chromatography separation has been coupled to electrospray ionization mass spectrometry for on-line characterization of drug metabolites of a therapeutic peptide in plasma. It is demonstrated that the selectivity, sensitivity and molecular weight data provided by immunoaffinity chromatography coupled to liquid chromatography/mass spectrometry provides a means of rapidly achieving qualitative determinations of small amounts of material in complicated biological matrices such as plasma. The ability to detect the peptide in rat plasma at a level of 10 ng/mL is demonstrated using this method. In addition, experiments to study the epitope of the peptide by enzymatic digestion and mass spectrometry are also discussed. The method is proposed as an alternative approach to studying the metabolism of therapeutic peptides.  相似文献   

3.
To address immunocapture of proteins in large cohorts of clinical samples high throughput sample processing is required. Here a method using the proteomic sample platform, ISET (integrated selective enrichment target) that integrates highly specific immunoaffinity capture of protein biomarker, digestion and sample cleanup with a direct interface to mass spectrometry is presented. The robustness of the on-ISET protein digestion protocol was validated by MALDI MS analysis of model proteins, ranging from 40 fmol to 1 pmol per nanovial. On-ISET digestion and MALDI MS/MS analysis of immunoaffinity captured disease-associated biomarker PSA (prostate specific antigen) from human seminal plasma are presented.  相似文献   

4.
An overview on the utilization of monoliths in proteomics technology will be given. Both silica- and polymer-based monoliths have broad use for microseparation of tryptic peptides in reversed-phase (RP) mode before identification by mass spectrometry (MS) or by MS/MS. For two-dimensional (2D) LC separation of peptides before MS or MS/MS analysis, a combination of ion-exchange, usually cation-exchange (CEX) chromatography with RP chromatography on monolithic supports can be employed. Immobilized metal ion affinity chromatography monoliths with immobilized Fe3+-ions are used for the isolation of phosphopeptides. Monoliths with immobilized affinity ligands are usually applied to the rapid separation of proteins and peptides. Miniaturized reactors with immobilized proteolytic enzymes are utilized for rapid on- or offline digestion of isolated proteins or protein mixtures prior to identification by LC-MS/MS. Monoliths also have broad potential for application in sample preparation, prior to further proteomic analyses. Monolithic supports with large pore sizes can be exploited for the isolation of nanoparticles, such as cells, organelles, viruses and protein aggregates. The potential for further adoption of monolithic supports in protein separation and enrichment of low abundance proteins prior to proteolytic digestion and final LC-MS/MS protein identification will be discussed.  相似文献   

5.
Multi-analyte binding assays for rapid screening of food contaminants require mass spectrometric identification of compound(s) in suspect samples. An optimal combination is obtained when the same bioreagents are used in both methods; moreover, miniaturisation is important because of the high costs of bioreagents. A concept is demonstrated using superparamagnetic microbeads coated with monoclonal antibodies (Mabs) in a novel direct inhibition flow cytometric immunoassay (FCIA) plus immunoaffinity isolation prior to identification by nano-liquid chromatography–quadrupole time-of-flight-mass spectrometry (nano-LC-Q-ToF-MS). As a model system, the mycotoxin ochratoxin A (OTA) and cross-reacting mycotoxin analogues were analysed in wheat and cereal samples, after a simple extraction, using the FCIA with anti-OTA Mabs. The limit of detection for OTA was 0.15 ng/g, which is far below the lowest maximum level of 3 ng/g established by the European Union. In the immunomagnetic isolation method, a 350-times-higher amount of beads was used to trap ochratoxins from sample extracts. Following a wash step, bound ochratoxins were dissociated from the Mabs using a small volume of acidified acetonitrile/water (2/8 v/v) prior to separation plus identification with nano-LC-Q-ToF-MS. In screened suspect naturally contaminated samples, OTA and its non-chlorinated analogue ochratoxin B were successfully identified by full scan accurate mass spectrometry as a proof of concept for identification of unknown but cross-reacting emerging mycotoxins. Due to the miniaturisation and bioaffinity isolation, this concept might be applicable for the use of other and more expensive bioreagents such as transport proteins and receptors for screening and identification of known and unknown (or masked) emerging food contaminants.  相似文献   

6.
In this study, we developed a novel microwave-assisted protein preparation and digestion method for matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry analysis and identification of proteins that involves using conductive carbon tape as a sample platform for sample preparation (reduction and alkylation) and digestion under microwave heating and as a plate for MALDI analysis. This method allows for the enzymatic digestion products of proteins to be directly analyzed by MALDI mass spectrometry and results in a marked reduction in sample loss. Our protocol requires only a small volume (1 μL) of reaction solvent, which increases the frequency of enzyme-to-protein contact, thereby resulting in more efficient digestion of sample than conventional in-solution digestion methods. To test this protocol, we used magnetic iron (II, III) oxide nanoparticles as concentrating probes to enrich phosphopeptides from a mixture of peptides in enzymatically digested protein samples. We found that the one-pot on-tape-based protein preparation and digestion under microwave heating combined with the on-tape-based enrichment method not only dramatically reduced the time required for phosphopeptides analysis but also allowed for the simultaneous identification of phosphoproteins. The advantages of our protocol include ease of use, high digestion efficiency, high specificity, and rapid (15 min) identification of proteins and enrichment of phosphopeptides in a mixture of enzymatically digested protein samples.  相似文献   

7.
For many years, EC regulations have prohibited the use of anabolic agents in food-producing animals. Multiple screening methods have been published, but some lack specificity and some are difficult to apply when screening for unknowns in surveillance programmes. This paper presents a new and powerful technique, combining multiresidue immunoaffinity chromatography and GC-MS, for the simultaneous identification and semi-quantification of various anabolic steroids in urine and faeces samples of bovine origin. It should reduce the cost, time and effort of screening by limiting the number of tedious clean-up steps and analyses required. A preliminary extraction step is applied to the individual biological specimens: solid-phase extraction followed by enzymatic digestion in the case of urine samples and a single liquid extraction step for faeces. This step is followed by a first clean-up step involving both a solid-phase column and a rapid RP-HPLC separation. The individual biological fractions (urine or faeces) are further purified on a multiresidue immunoaffinity chromatographic gel (MIAC-steroids-CER) so as to decrease interferences due mainly to background signals. A final trimethylsilyl derivatization is followed by the analysis of the biological samples by a sensitive and specific GC-MS procedure.  相似文献   

8.
We describe here a new approach for the identification of affinity-bound proteins by proteolytic generation and mass spectrometric analysis of their antibody bound epitope peptides (epitope excision). The cardiac muscle protein troponin T was chosen as a protein antigen because of its diagnostic importance in myocardial infarct, and its previously characterised epitope structure. Two monoclonal antibodies (IgG1-1B10 and IgG1-11.7) raised against intact human troponin T were found to be completely cross reactive with bovine heart troponin T. A combination of immuno-affinity isolation, partial proteolytic degradation (epitope excision), mass spectrometric peptide mapping, and database analysis was used for the direct identification of Tn T from bovine heart cell lysate. Selective binding of the protein was achieved by addition of bovine heart cell lysate to the Sepharose-immobilised monoclonal antibodies, followed by removal of supernatant material containing unbound protein. While still bound to the affinity matrix the protein was partially degraded thereby generating a set of affinity-bound, overlapping peptide fragments comprising the epitope. Following dissociation from the antibody the epitope peptides were analysed by matrix assisted laser desorption-ionisation (MALDI) and electrospray-ionisation (ESI) mass spectrometry. The peptide masses identified by mass spectrometry were used to perform an automated database search, combined with a search for a common "epitope motif". This procedure resulted in the unequivocal identification of the protein from biological material with only a minimum number of peptide masses, and requiring only limited mass-determination accuracy. The dramatic increase of selectivity for identification of the protein by combining the antigen-antibody specificity with the redundancy of peptide sequences renders this "affinity-proteomics" approach a powerful tool for mass spectrometric identification of proteins from biological material.  相似文献   

9.
A bottom-up proteomic approach, based on capillary electrophoresis (CE) in combination with matrix- assisted laser desorption/ionization tandem time-of-flight mass spectrometry (MALDI-ToF/ToF MS), was used to analyze immunoaffinity depleted human cerebrospinal fluid (CSF) and compare it with a non-depleted sample. After enzymatic digestion and desalting, the tryptic peptides were separated by CE using PolyE-323 modified capillaries and fractionated off-line onto MALDI target plates for further analysis by MALDI-MS and MS/MS. The protein profile of the depleted sample was compared with non depleted CSF. Overall, 85 proteins were identified with 95% significance in both samples. The significance scores for proposed biomarkers, such as amyloid-like protein 1 precursor, could be increased up to 12 times after the depletion. Other proteins, often suggested to be related to neurodegenerative diseases, like amyloid beta A4 protein precursor, superoxide dismutase and apolipoprotein E precursor could only be found in the depleted CSF samples. The effect of a derivatization of tryptic peptides with 2- methoxy-4,5-dihydro-1H-imidazole reagent for protein identification with MS was also employed to increase the number of identified proteins and the sequence coverages. The results presented in this study illustrate the benefit of combining a sample pre-fractionation step and a label's ability to enhance the ionization efficiency with the potential of CE using PolyE-323 modified capillaries in the analysis of complex samples. The straight-forward approach that provides speed and simplicity resulting in high-resolution separations and low sample consumption represents an easily applicable separation technique that can serve as a complement to other currently existing analytical approaches needed in modern proteomic analysis of clinically relevant samples.  相似文献   

10.
采用免疫亲和分离与质谱分析相结合的方法, 对β2-微球蛋白抗原表位进行了系统研究. 完整的抗原分子和已固定在载体(CNBr-activated Sepharose beads)上的单克隆抗体发生免疫亲和反应后, 用Endoproteinase Glu-C, Trypsin, Aminopeptidase M和carboxypeptidase Y四种不同的蛋白酶依次酶解抗原分子, 并采用基质辅助激光解析电离飞行时间质谱(MALDI-TOF-MS)技术对与抗体连接受保护而未发生水解的肽段进行了研究. 结果表明: β2-微球蛋白抗原表位位于整个蛋白分子氨基酸序列的61~67位, 即为SFYLLYY. 通过合成肽段的分析, 证明了SFYLLYY即为抗原表位, 与亲和质谱方法分析结果一致.  相似文献   

11.
本文通过戊二醛法合成免疫磁球(IMMs),采用荧光电镜、透射电镜和振动样品磁强计对其进行表征。合成的IMMs为单分散的球形结构,粒径约为510 nm,具有超顺磁性(饱和磁化强度为40.44 emu/g)。基于此,以牛血清白蛋白(BSA)作为蛋白质模型,建立了免疫亲和富集-荧光光谱法用于目标蛋白质的分离与检测。考察并优化了影响免疫亲和富集的因素。在最佳实验条件下,IMMs对目标蛋白质的最大吸附容量为107.7μg/g,可重复使用10次以上。将该方法应用于人血清基质中BSA的测定,加标回收率不低于89.3%,由基质辅助激光解吸电离飞行时间质谱仪测得分离后的BSA纯度较高。结果表明,该方法适用于人血清样品中蛋白质的选择性分离与检测。  相似文献   

12.
Peptide analysis in doping controls by means of nano-UPLC coupled high resolution/high mass accuracy mass spectrometry provides the state-of-the-art technique in modern sports drug testing. The present study describes a recent application of this technique for the qualitative determination of different urinary insulin-like growth factor (IGF) related peptides. After simultaneous isolation by solid phase extraction and magnetic particle-based immunoaffinity purification, target analytes (IGF-1, IGF-2, Des1-3-IGF-1, R(3)-IGF-1 and longR(3)-IGF-1) were separated by nano-liquid chromatography prior to mass spectrometric detection. Endogenously produced IGF-1 and IGF-2, as well as the degradation product Des1-3-IGF-1, were frequently detected in urine samples from healthy volunteers in a concentration range of 20-400 pg mL(-1). The impact of IGF binding proteins (IGFBPs), being also present in urine, was potentially estimated by an additional ultrafiltration step in the sample preparation procedure. The synthetic analogue longR(3)-IGF-1, which is assumed to be subject to misuse by cheating athletes, was also analysed and detected in fortified urine samples. Besides the intact molecule, an N-terminally truncated degradation product Des1-10-longR(3)-IGF-1 was identified as the more stable target for doping controls using urine samples. The method was validated for qualitative purposes considering the parameters specificity, limit of detection (20-50 pg mL(-1)), recovery (10-35%), precision (<20%), linearity, robustness and stability.  相似文献   

13.
Complex matrices commonly affect the sensitivity and selectivity of liquid chromatography-mass spectrometry (LC-MS) analysis. Thus, selective sample enrichment strategies are useful particularly to analyze organic biomarkers present in low abundance in samples. A selective immunomagnetic extraction procedure to isolate trace peanut allergen protein Ara h3/4 from breakfast cereals combined with microwave-assisted tryptic digestion and liquid chromatography-electrospray ion-trap tandem mass spectrometry (LC-ESI-IT-MS/MS) measurement was developed. Using protein A-coated magnetic bead (MB) support, anti-Ara h3/4 monoclonal antibodies (Abs) were used as selective capture molecules. The results obtained by LC-ESI-IT-MS/MS in terms of limit of detection (3mg peanuts/kg matrix) and a significantly reduced matrix effect demonstrated that the Ab-coated magnetic bead was very effective to selectively trap Ara h3/4 protein in breakfast cereals. The magnetic bead-based sample treatment followed by LC-IT-MS/MS method here developed can be proposed as very rapid and powerful confirmatory analytical method to verify the reliability of enzyme-linked immunosorbent assay (ELISA) screening methods, since the magnetic bead-LC-IT-MS/MS method combines good sensitivity to the identification capabilities of mass spectrometry.  相似文献   

14.
Mass spectrometric approaches have recently gained increasing access to molecular immunology and several methods have been developed that enable detailed chemical structure identification of antigen-antibody interactions. Selective proteolytic digestion and MS-peptide mapping (epitope excision) has been successfully employed for epitope identification of protein antigens. In addition, "affinity proteomics" using partial epitope excision has been developed as an approach with unprecedented selectivity for direct protein identification from biological material. The potential of these methods is illustrated by the elucidation of a beta-amyloid plaque-specific epitope recognized by therapeutic antibodies from transgenic mouse models of Alzheimer's disease. Using an immobilized antigen and antibody-proteolytic digestion and analysis by high resolution Fourier transform ion cyclotron resonance mass spectrometry has lead to a new approach for the identification of antibody paratope structures (paratope-excision; "parex-prot"). In this method, high resolution MS-peptide data at the low ppm level are required for direct identification of paratopes using protein databases. Mass spectrometric epitope mapping and determination of "molecular antibody-recognition signatures" offer high potential, especially for the development of new molecular diagnostics and the evaluation of new vaccine lead structures.  相似文献   

15.
Direct extraction of bacterial vegetative cells or spores followed by matrix-assisted laser desorption ionization/time of flight mass spectrometry (MALDI TOF MS) has become popular for bacterial identification, since it is simple to perform and mass spectra are readily interpreted. However, only high-abundance proteins that are of low mass and ionize readily are observed. In the case of B. anthracis spores, small acid-soluble spore proteins (SASPs) have been the most widely studied. Additional information can be obtained using tandem mass spectrometry (MS-MS) to confirm the identity of proteins by sequencing. This is most readily accomplished using ion trap (IT) MS-MS. However, enzymatic digestion of these proteins is needed to generate peptides that are within the mass range of the ion trap. The use of sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE), or other forms of electrophoresis, allows one to focus on specific proteins of interest (e.g. the high mass exosporium glycoproteins BcIA and BcIB) that provide additional species- and strain-specific discrimination.  相似文献   

16.
We paper describe a mass spectrometric approach generally applicable for the rapid identification and characterization of proteins isolated by two-dimensional gel electrophoresis (2-DE). The highly sensitive nanoflow-electrospray mass spectrometry employing a quadrupole-time of flight mass spectrometer was used for the direct identification of proteins from the peptide mixture generated from only one high resolution 2-DE gel without high performance liquid chromatography (HPLC) separation or Edman sequencing. Due to the high sensitivity and high mass accuracy of the instrument employed, this technique proved to be a powerful tool for the identification of proteins from femtomole amounts of materials. We applied the technique for the investigation of Burkitt lymphoma BL60 cell proteins. This cell line has been used as a model to assign apoptosis-associated proteins by subtractive analysis of normal and apoptotic cells. From the nuclear fraction of these cells, 36 protein spots were examined, from only one micropreparative Coomassie Brilliant Blue R-250 stained gel, after proteolytic digestion by matrix assisted laser desorption ionization (MALDI) and nanospray mass spectrometry (MS). In combination with database searches, of 33 proteins were successfully identified by nanospray-MS/MS-sequencing of up to eight peptides per protein. Three proteins were new proteins not listed in any of the available databases. Some of the identified proteins are known to be involved in apoptosis processes, the others were common proteins in the eukaryotic cell. The given technique and the protein data are the basis for construction of a database to compare normal and apoptosis-induced cells and, further, to enable fast screening of drug impact in apoptosis-associated processes.  相似文献   

17.
MALDI imaging mass spectrometry (MALDI-IMS) has become a powerful tool for the detection and localization of drugs, proteins, and lipids on-tissue. Nevertheless, this approach can only perform identification of low mass molecules as lipids, pharmaceuticals, and peptides. In this article, a combination of approaches for the detection and imaging of proteins and their identification directly on-tissue is described after tryptic digestion. Enzymatic digestion protocols for different kinds of tissues—formalin fixed paraffin embedded (FFPE) and frozen tissues—are combined with MALDI-ion mobility mass spectrometry (IM-MS). This combination enables localization and identification of proteins via their related digested peptides. In a number of cases, ion mobility separates isobaric ions that cannot be identified by conventional MALDI time-of-flight (TOF) mass spectrometry. The amount of detected peaks per measurement increases (versus conventional MALDI-TOF), which enables mass and time selected ion images and the identification of separated ions. These experiments demonstrate the feasibility of direct proteins identification by ion-mobility-TOF IMS from tissue. The tissue digestion combined with MALDI-IM-TOF-IMS approach allows a proteomics “bottom-up” strategy with different kinds of tissue samples, especially FFPE tissues conserved for a long time in hospital sample banks. The combination of IM with IMS marks the development of IMS approaches as real proteomic tools, which brings new perspectives to biological studies.  相似文献   

18.
Sim TS  Kim EM  Joo HS  Kim BG  Kim YK 《Lab on a chip》2006,6(8):1056-1061
We have carried out a simultaneous thermal denaturation and trypsin digestion of proteins using a temperature-controllable microreactor. This is a simple and rapid sample preparation technique for use before matrix-assisted laser desorption ionization time-of-flight mass spectrometry. In contrast to a conventional sample preparation method, which involves several chemical treatments, our sample preparation was performed using only trypsin digestion with the thermal denaturation of the target protein. Optimization of the reactor operational parameters for trypsin digestion using a temperature-controllable microreactor was carried out. The entire trypsin digestion procedure took about 11 min, and consisted of 1 min for the thermal denaturation of the sample protein (3 microl, 0.2 microM) at 85 degrees C, and 10 min for digestion of the protein at 37 degrees C. The resulting sequence coverage ranged from 24% to 57%, which was sufficient for practical protein identification.  相似文献   

19.
Recent studies have demonstrated the need for complementing cellular genomic information with specific information on expressed proteins, or proteomics, since the correlation between the two is poor. Typically, proteomic information is gathered by analyzing samples on two-dimensional gels with the subsequent identification of specific proteins of interest by using trypsin digestion and mass spectrometry in a process termed peptide mass fingerprinting. These procedures have, as a rule, been labor-intensive and manual, and therefore of low throughput. The development of automated proteomic technology for processing large numbers of samples simultaneously has made the concept of profiling entire proteomes feasible at last. In this study, we report the initiation of the (eventual) complete profile of the rat mitochondrial proteome by using high-throughput automated equipment in combination with a novel fractionation technique using minispin affinity columns. Using these technologies, approximately one hundred proteins could be identified in several days. In addition, separate profiles of calcium binding proteins, glycoproteins, and hydrophobic or membrane proteins could be generated. Because mitochondrial dysfunction has been implicated in numerous diseases, such as cancer, Alzheimer's disease and diabetes, it is probable that the identification of the majority of mitochondrial proteins will be a beneficial tool for developing drug and diagnostic targets for associated diseases.  相似文献   

20.
Specific capture of phosphopeptides from protein digests is a critical step for identification of phosphoproteins by mass spectrometry. In this study, we report a novel phosphopeptide-capture approach based on the specific interaction of phosphopeptides with a stainless steel target modified with magnetic affinity nanoparticles. The modification which was carried out by loading the suspension of nanoparticles into sample wells of the target did not require any pretreatment procedure to the target and did not involve chemical binding reactions. To isolate phosphopeptides, digests were loaded into the wells of the modified target for 10 min incubation, followed by rinsing with washing buffer to remove unbound species; matrix was then added to the captured phosphopeptides prior to analysis by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). Capturing the phosphopeptides on the modified target simplified significantly analytical operations and reduced sample loss. This approach has been applied to solution digests of alpha-casein, beta-casein, and a mixture of five proteins; a number of phosphopeptides were confidently detected. Phosphopeptides from digests of 10 fmol beta-casein could be isolated and detected by MALDI-TOFMS with this method. In addition, this approach has been applied successfully to the isolation of phosphopeptides from in-gel digestive products of sub-pmol phosphoproteins after separation by sodium dodecyl sulfate/polyacrylamide gel electrophoresis (SDS-PAGE).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号