首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
T Takeuchi  M Shinogi 《Radioisotopes》1979,28(12):729-733
Instrumental neutron activation analysis by the monostandard method has been applied to the analyses of biological NBS standard reference materials; 1571 Orchard Leaves and 1577 Bovine Liver. Aluminum foils containing 0.100% gold or 2.00% cobalt were used as the monostandards. The gamma-ray spectral data were recorded on punched paper tape and were analyzed by a computer assisted data processing. The following 25 elements were determined: Al, Ca, Cl Cu, Mg, Mn, V (by short period irradiation), As, Ba, Br, Co, Cr, Cs, Eu, Fe, Hg, K, La, Na, Rb, Sb, Sc, Se, Sm and Zn (by long period irradiation). The results were compared with the certified values by NBS and the reported values in literatures to prove the reliability and accuracy of the monostandard method.  相似文献   

2.
A comparative study is presented on neutron activation analysis of rock and soil samples using whole reactor neutron spectrum and epithermal neutrons with both relative and monostandard procedures. The latter procedure used with epithermal neutron activation analysis of soil samples necessitated the use of the “effective resonance integrals” which were determined experimentally. The incorporation of the β factor, representing deviation of reactor epithermal neutron flux from 1/E law, is developed in the present work. The main criteria for the choice of one or more of the procedures studied for a given purpose are also indicated. Analysis of 15 trace elements, Ca and Fe in the standard Japanese granite JC-1 using monostandard epithermal neutron activation gave results in good agreement with the average literature values. This paper is dedicated to the 80th birthday of Professor Dr. Robert Klement, University of Munich.  相似文献   

3.
A method is described for epithermal neutron activation analysis of 17 elements in granite rock samples using a single standard. Gold has been used as a single comparator due to its relatively high resonance integral value (I0=400 barn). In addition, it is preferable to Co in order to obtain a large epithermal activation in a short irradiation. The method of calculation is simple and rapid and can be done using a small calculator. Epithermal activation is able to overcome the difficulty arising from changing irradiation position as well as increasing the number of determinable elements by eliminating the interference from undesired isotopes which have relatively high thermal cross section values (0), when reactor neutron flux is used. The coupling of epithermal activation with the monostandard method has the advantage of using a small Cd-cover which overcomes most of the difficulties arising in the relative method with large volume cadmium filters.  相似文献   

4.
The reproducibility, the small scale as well as the large scale variability of137Cs extracted sequentially from the soil by using a modified Tessier procedure was investigated at several grassland sites in Bavaria/Germany and in the Chemobyl area. Because undisturbed grassland soils are never homogeneous with respect to their soil properties, all sequential extractions at the German sites were carried out at each plot separately for different soil layers (e.g., 0–2, 2–5, 5–10, 10–15, 15–20 and 20–30 cm). The results show that the coefficients of variation (CV) for the reproducibility of the extraction procedure for137Cs was (with some exceptions) around 10–20% for all fractions. For the small scale variability of137Cs (samples within an area of 10×10m2) the values for theCV were (again with a few exceptions) in the same range. Compared to that, the large scale variability of extractable137Cs (random soil samples within an area of 100×200 km2) was higher for all fractions, even though only moderately. The implications of these results with respect to a sampling design are discussed.  相似文献   

5.
A new approach is presented for neutron activation analysis using the monostandard (single comparator) method. Elements to be determined are classified into two groups; those with σo>Io are activated with whole neutron spectrum (without Cd-cover), using a standard of the same group (e.g. Sc), while elements with Ioo are activated with epithermal neutrons (under Cd-cover) using a standard of the same group (e.g. Au or Co). Epithermal activation increases the number of determinable elements and its coupling with the monostandard method has the advantage of using a small Cd-cover. The σo and I0 values of some elements were determined to test this approach.  相似文献   

6.
A scheme for instrumental neutron activation analysis of biological materials is proposed. The scheme is based on a combination of thermal and epithermal activation. The accuracy is evaluated by analyzing 4 standard reference materials. Results from the analysis of human blood serum and plasma are given.  相似文献   

7.
8.
The aim of the present work was to deal primarily with a few essential trace elements and to obtain reliable results of adequate accuracy and precision for the analysis of biological samples. A few other than trace elements were determined by the nondestructive technique as they can be well evaluated from the gamma-spectra. In the development of the method BOWEN's kale was chosen as model material. To confirm the reliability of the method two samples were analysed proposed by the IAEA in the frame of an international comparative analysis series. The comparative analysis shows the present method to be reliable, the precision and accuracy are good.  相似文献   

9.
Epithermal neutron activation analysis (ENAA) was applied to the determination of the contents of bromine and iodine in 40 biological and environmental standard reference materials and Chinese diets. Boron nitride (BN) for solid samples and BN+Cd for liquid samples were adopted as shield material. Irradiation was carried out in inner and outer irradiation sites in a Miniature Source Reactor (MNSR) for solid and liquid samples, respectively. The 443 keV photopeak of 128I and the 616 keV photopeak of 80Br were used. The precision of measurement (relative standard deviation) is 2∼6% for contents of iodine of more than 100 ng/g and 8∼12% in the 20∼100 ng/g range in solid samples, and 12∼18% at less than 100 ng/ml in liquid samples. For bromine, the precision of measurement is 2–8% for solid samples and lower than 13% for liquid samples. The detection limits under experimental conditions varied between 10∼30 ng/g, 55∼95 ng/g and 25∼68 ng/g for iodine and 50∼150 ng/g, 200∼450 ng/g and 100∼300 ng/g for bromine in ENAA with BN shield in inner irradiation sites, with Cd shield and BN+Cd shield in outer irradiation sites, respectively. Received: 13 June 1996 / Revised: 2 September 1996 / Accepted: 19 September 1996  相似文献   

10.
The potential of photon activation analysis (PAA) for multielement trace analysis can hardly compare with that of neutron activation analysis (NAA). However, PAA appears superior over NAA for the determination of a number of elements, namely C, N, O, F, Mg, Si, Ca, Ti, Ni, Sr, Y, Zr, Nb, Sn, Tl and Pb in geological, environmental and biological materials. Most of these and other elements can be determined using nondestructive, instrumental PAA (IPAA), especially in geological materials. The possibilities of IPAA for multielement analysis using photoexitation and other photonuclear reactions are reviewed and compared with those of instrumental NAA (INAA), namely for geological materials. The need for and usefulness of radiochemical PAA (RPAA) procedures are also discussed.  相似文献   

11.
Sodium contents in seven mixtures of biological materials from varying aliquants of wheat flour and oyster tissue were analyzed using the INAA (instrumental neutron activation analysis) method. The samples were activated in the thermal column (TC) of the 1 MW TRIGA reactor at our laboratory. To analyze and compare the measured results, the ratioa of the epithermal neutron flux to the thermal neutron flux was determined in the TC, the rotating rack (RR) and the pneumatic terminal (PT). Due to the negligible interferences of24Mg(n, p)24Na and27Al(n, )24Na to23Na(n, )24Na, the Na results were obtained with 97% accuracy and 99% precision. It is shown that the method is suited for accurately determining Na contents in 12 various biological materials, especially for the samples that are low in Na content. From the cadmium ratio measurements of Au (4.9 eV resonance of198Au) and Sm (8 eV resonance of153Sm), ratios ofae/0 were determined at 0.0011, 0.052 and 0.053 in the TC, RR and PT activation positions, respectively.  相似文献   

12.
Sources of error in the fast neutron activation analysis determination of oxygen have been investigated and minimised. The oxygen contents of eighteen international rock standards and a sulphide ore standard have been determined, and compared with the values calculated by difference using the reported full analyses. Accuracies of 0.3% average deviation and reproducibilities of ±0.2% standard deviation have been obtained, where oxygen contents exceeded 1.0 g.  相似文献   

13.
Summary The great usefulness of reference materials, especially ones of certified elemental composition, is discussed with particular attention devoted to their use in instrumental neutron activation analysis (INAA) work. Their use, including both certified and uncertified values, in calculations made by the INAA Advance Prediction Computer Program (APCP) is discussed. The main features of the APCP are described, and mention is made of the large number of reference materials run on the APCP (including the new personal computer version of the program), with NBS Oyster Tissue SRM-1566 used as the principal example.  相似文献   

14.
15.
The “absolute” quantitative processing of complex gamma-ray spectra has been made possible by the use of high resolution detectors and by irradiation with a well thermalized neutron flux. So, the simultaneous determination of many stable elements, either major or trace components is possible without destruction of the sample. The results of measurements on the irradiated samples show a threefold recurrence: (1) each element appears as often as it possesses activable isotopes, under the form of ray emitting nuclides, (2) each nuclide is determined as often as it presents ditinct emission lines, (3) all measurements are repeated in time. So under these conditions and with an original computer data processing, neutron activation analysis is a powerful analytical tool. The recurrence of the results gives access to the interpretation of the origin of various errors which consequently are better estimated. If applied to the study of ancients ceramics, this method should perhaps allow to evaluate the relationship between the geochemical imprint characteristic of the artifact and the original location, or even workshop.  相似文献   

16.
In this work, neutron activation analysis was applied to analyze the geological standard materials: GSP-1 and W-1 from USGS, GB-1 and BB-1 from the University of Bahia, Brazil and a sample of uraniferous rock. Hf was determined by instrumental method and the obtained results was shown with relative standard deviations varying from 1.1 to 14%. In the case of Zr analyses, both instrumental and radiochemical neutron activation analyses were used. The interference of154Eu radioisotope that emits -rays too close to those emitted by95Zr was eliminated by retention of Zr in an anionic exchange resin column. The contribution of uranium fission product was considered in the Zr determination by using an interference factor. Results of Zr were presented with relative standard deviations varying from 2.0 to 25.7%. More precise results were obtained by using radiochemical separation. The concentration obtained for Hf and Zr in reference materials agreed well with respective certified values or information values.  相似文献   

17.
The determination of bromine in biological material by thermal neutron activation analysis using instrumental [Ge(Li)] and radiochemical separation techniques is described. The radiochemical method is ten times more sensitive (0.4 ng) than the instrumental technique but both may be used for analysis of the majority of human tissue samples. Both techniques are rapid, simple, accurate and may be used for batch analysis.  相似文献   

18.
Fourteen trace elements (short-lived nuclides: Al, Br, Cu, Mn and V; long-lived nuclides: Ag, Au, Cd, Co, Cr, Fe, Sc, Se and Zn) in human eye tissues are determined simultaneously by non-destructive neutron activation analysis. The quantity of Al, Br, Fe, Se and Zn in the eye tissues (about 1 to more than 10 μg/g dry weight tissue) seems to be higher than that of other trace elements, although content of each trace element in individual tissue are scattered in a wide range. Conjunctiva, iris (+ciliary body) and choroid (+pigment epithelium) seem to contain larger amount of various trace elements than other eye tissues. From correlation studies it is evident that the relative distribution of 14 trace elements in various eye tissues are similar, and furthermore the content of trace elements in the eye tissues may be correlated in each of the three groups (group A: Cd, Fe, Se and Zn; group B: Al, Cr, Fe, Se and V; group C: Al, Au, Fe and Se).  相似文献   

19.
Contents of 13 trace elements in human hair were determined by neutron activation analysis. The distribution patterns of mean values of elements were extremely similar in all groups, though the contents of elements were individually different in each group. Numerous elements in new-born infants of both sexes correlated with each other, especially with V at a 95% confidence level. Special characteristics of diseased infants were the high contents of Cl and the low contents of Cr. It is presumed that these facts are due to the imbalanced acid-base equilibrium and some abnormal metabolic systems in diseased bodies.  相似文献   

20.
A method, based on the measurement of the -photopeak at 332 keV arising from a124Sn(n, )125mSn reaction, has been developed for the rapid measurement of Sn at concentrations of 20 g g–1, present as the cross-linking agent, in explosive charges. The method is comparative, and has a limit of detection of 0.6 g g–1 and a precision of 5% RSD. The method requires no sample preparation and is economical in effort.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号