首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Noninvasive absolute quantification of cerebral blood flow (CBF) with high spatial resolution is still a challenging task. Arterial spin labeling (ASL) is a promising magnetic resonance imaging (MRI) method for accurate perfusion quantification. However, modeling of ASL data is far from being standardized and has not been investigated in great detail. In this study, two-compartment modeling of monkey ASL data in three physiological conditions (baseline, sensory activated and globally elevated CBF) is reported. Absolute perfusion and arterial transit times were derived for gray matter (GM) and white matter (WM) separately. The uncertainties of the model's result were determined by Monte Carlo simulations. The fitted CBF values for GM were 133 ml/min/100 ml at baseline condition, 165 ml/min/100 ml during visual stimulation and 234 ml/min/100 ml for globally elevated CBF after intravenous injection of acetazolamide. The ratio of GM to WM CBF was 2.5 at baseline and was found to decrease to 1.6 after application of acetazolamide. The corresponding arterial transit times decreased from 742 to 607 ms in GM and from 985 to 875 ms in WM. Monte Carlo simulations showed that absolute CBF values can be determined with an error of 11-15%, while the arterial transit time values have a coefficient of variation of 25-31%. With an alternative acquisition scheme, the precision of the arterial transit times can be improved significantly. The CBF values in the occipital lobe of the monkey brain quantified with ASL are higher than previously reported in positron emission tomography studies.  相似文献   

2.

Purpose

To compare absolute cerebral blood flow (CBF) estimates obtained by model-free arterial spin labeling (ASL) and dynamic susceptibility contrast MRI (DSC-MRI), corrected for partial volume effects (PVEs).

Methods

CBF was measured using DSC-MRI and model-free ASL (quantitative signal targeting with alternating radiofrequency labeling of arterial regions) at 3 T in 15 subjects with brain tumor, and the two modalities were compared with regard to CBF estimates in normal gray matter (GM) and DSC-to-ASL CBF ratios in selected tumor regions. The DSC-MRI CBF maps were calculated using a global arterial input function (AIF) from the sylvian-fissure region, but, in order to minimize PVEs, the AIF time integral was rescaled by a venous output function time integral obtained from the sagittal sinus.

Results

In GM, the average DSC-MRI CBF estimate was 150±45 ml/(min 100 g) (mean±SD) while the corresponding ASL CBF was 44±10 ml/(min 100 g). The linear correlation between GM CBF estimates obtained by DSC-MRI and ASL was r=.89, and observed DSC-to-ASL CBF ratios differed by less than 3% between GM and tumor regions.

Conclusions

A satisfactory positive linear correlation between the CBF estimates obtained by model-free ASL and DSC-MRI was observed, and DSC-to-ASL CBF ratios showed no obvious tissue dependence.  相似文献   

3.
Arterial spin labeling (ASL) magnetic resonance imaging (MRI) is becoming a popular method for measuring perfusion due to its ability of generating perfusion maps noninvasively. This allows for frequent repeat scanning, which is especially useful for follow-up studies. However, limited information is available regarding the reliability and reproducibility of ASL perfusion measurements. Here, the reliability and reproducibility of pulsed ASL was investigated in an elderly population to determine the variation in perfusion among cognitively normal individuals in different brain structures. Intraclass correlation coefficients (ICC) and within-subject variation coefficients (wsCV) were used to estimate reliability and reproducibility over a period of 1 year. Twelve cognitively normal subjects (75.5±5.3 years old, six male and six female) were scanned four times (at 0, 3, 6 and 12 months). No significant difference in cerebral blood flow (CBF) was found over this period. CBF values ranged from 46 to 53 ml/100 g per minute in the medial frontal gyrus (MFG) and from 40 to 44 ml/100 g per minute over all gray matter regions in the superior part of the brain. Data obtained from the first two scans were processed by two readers and showed high reliability (ICC >0.97) and reproducibility (wsCV <6%). However, over the total period of 1 year, reliability reduced to a moderate level (ICC=0.63–0.74) with wsCVs of gray matter, left MFG, right MFG of 13.5%, 12.3%, and 15.4%, respectively. In conclusion, measurement of CBF with pulsed ASL provided good agreement between inter-raters. A moderate level of reliability was obtained over a 1-year period, which was attributed to variance in slice positioning and coregistration. As such pulsed ASL has the potential to be used for CBF comparison in longitudinal studies.  相似文献   

4.
Measurement of perfusion in longitudinal studies allows for the assessment of tissue integrity and the detection of subtle pathologies. In this work, the feasibility of measuring brain perfusion in rats with high spatial resolution using arterial spin labeling is reported. A flow-sensitive alternating recovery sequence, coupled with a balanced gradient fast imaging with steady-state precession readout section was used to minimize ghosting and geometric distortions, while achieving high signal-to-noise ratio. The quantitative imaging of perfusion using a single subtraction method was implemented to address the effects of variable transit delays between the labeling of spins and their arrival at the imaging slice. Studies in six rats at 7 T showed good perfusion contrast with minimal geometric distortion. The measured blood flow values of 152.5±6.3 ml/100 g per minute in gray matter and 72.3±14.0 ml/100 g per minute in white matter are in good agreement with previously reported values based on autoradiography, considered to be the gold standard.  相似文献   

5.
Arterial spin labeling (ASL) using magnetic resonance imaging (MRI) is a powerful noninvasive technique to investigate the physiological status of brain tissue by measuring cerebral blood flow (CBF). ASL assesses the inflow of magnetically labeled arterial blood into an imaging voxel. In the last 2 decades, various ASL sequences have been proposed which differ in their ease of implementation and their sensitivity to artifacts. In addition, several quantification methods have been developed to determine the absolute value of CBF from ASL magnetization difference images. In this study, we evaluated three pulsed ASL sequences and three absolute quantification schemes. It was found that FAIR-QUIPSSII implementation of ASL yields 10–20% higher signal-to-noise ratio (SNR) and 18% higher CBF as compared with PICORE-Q2TIPS (with FOCI pulses) and PICORE-QUIPSSII (with BASSI pulses). In addition, quantification schemes employed can give rise to up to a 35% difference in CBF values. We conclude that, although all quantitative ASL sequences and CBF calibration methods should in principle result in the similar CBF values and image quality, substantial differences in CBF values and SNR were found. Thus, comparing studies using different ASL sequences and analysis algorithms is likely to result in erroneous intra- and intergroup differences. Therefore, (i) the same quantification schemes should consistently be used, and (ii) quantification using local tissue proton density should yield the most accurate CBF values because, although still requiring definitive demonstration in future studies, the proton density of blood is assumed to be very similar to the value of gray matter.  相似文献   

6.
Multislice Q2TIPS is a widely used pulsed arterial spin labeling (PASL) technique for efficient and accurate quantification of cerebral blood flow (CBF). Slices are typically acquired inferior to superior from a tagging plane. Superior slices show signal loss greater than the loss expected from blood T1 decay. In order to assess the reasons for this additional signal loss, three single-slice acquisition studies were compared to multislice acquisition (six slices) in healthy volunteers. In Study 1 (n=8), the tagging plane was fixed in location, and the inversion time (TI2) was 1500 ms for each slice. For Study 2 (n=12), the tagging plane was fixed as in Study 1; however, TI2 increased as slices were acquired further from the tagging plane. In Study 3 (n=9), the tagging plane was kept adjacent to the imaging slice, and TI2 was 1500 ms for every slice. Gray matter (GM) and white matter (WM) signal-to-noise ratio (SNR) and CBF were measured per slice. GM SNR from single-slice acquisitions was significantly higher at slices 4-6 in Study 2 and at slices 2-6 in Study 3 compared to multislice acquisitions. Signal loss in distal slices of multislice acquisitions can be attributed to the destruction of tagged bolus in addition to blood T1 decay. If limited brain coverage is acceptable, perfusion images with greater SNR are achievable with limited slices and placement of the tagging region immediately adjacent to the site of interest.  相似文献   

7.
PURPOSE: To identify regional arterial input functions (AIFs) using factor analysis of dynamic studies (FADS) when quantification of perfusion is performed using model-free arterial spin labelling. MATERIAL AND METHODS: Five healthy volunteers and one patient were examined on a 3-T Philips unit using quantitative STAR labelling of arterial regions (QUASAR). Two sets of images were retrieved, one where the arterial signal had been crushed and another where it was retained. FADS was applied to the arterial signal curves to acquire the AIFs. Perfusion maps were obtained using block-circulant SVD deconvolution and regional AIFs obtained by FADS. In the volunteers, the ASL experiment was repeated within 24 h. The patient was also examined using dynamic susceptibility contrast MRI. RESULTS: In the healthy volunteers, CBF was 64+/-10 ml/[min 100 g] (mean+/-S.D.) in GM and 24+/-4 ml/[min 100 g] in WM, while the mean aBV was 0.94% in GM and 0.25% in WM. DISCUSSION: Good CBF image quality and reasonable quantitative CBF values were obtained using the combined QUASAR/FADS technique. We conclude that FADS may be a useful supplement in the evaluation of ASL data using QUASAR.  相似文献   

8.
The development of phase-contrast magnetic resonance imaging (P-C MRI) provides a noninvasive method for measurement of volumetric blood flow (VFR). We performed P-C MRI to study the effects of physical characteristics on cerebral blood flow. VFR of the left and right internal carotid arteries and basilar artery were measured using P-C MRI and total cerebral blood flow (tCBF) was calculated by summing up the VFR values in the three vessels. Moreover, we investigated the changes in these blood flows as influenced by age, head size, height, weight, body surface area, and handedness. The blood flows were 142 ± 58 ml/min (mean ± standard deviation) in the basilar artery; and 229 ± 86 ml/min in the left, and 223 ± 58 ml/min in the right internal carotid artery; and tCBF was 617 ± 128 ml/min. Significant increases were observed in head size-related change of VFR in the basilar artery (p = .028) and height-related change of tCBF (p = .045). The other characteristics did not significantly influence any VFR. The results suggest that head size and height may reflect CBF, and that these effects should be considered when changes of CBF are diagnosed. Phase-contrast MRI is useful for a noninvasive and rapid analysis of cerebral VFR and has potential for clinical use.  相似文献   

9.
Functional magnetic resonance imaging (MRI) in the nonhuman primate promises to provide a much desired link between brain research in humans and the large body of systems neuroscience work in animals. We present here a novel high field, large-bore, vertical MR system (7 T/60 cm, 300 MHz), which was optimized for neuroscientific research in macaque monkeys. A strong magnetic field was applied to increase sensitivity and spatial resolution for both MRI and spectroscopy. Anatomical imaging with voxel sizes as small as 75×150×300 μm3 and with high contrast-to-noise ratios permitted the visualization of the characteristic lamination of some neocortical areas, e.g., Baillarger lines. Relaxation times were determined for different structures: at 7 T, T1 was 2.01/1.84/1.54 s in GM/GM-V1/WM, T2 was 59.1/54.4 ms in GM/WM and T2* was 29 ms. At 4.7 T, T1 was 25% shorter, T2 and T2* 18% longer compared to 7T. Spatiotemporally resolved blood-oxygen-level-dependent (BOLD) signal changes yielded robust activations and deactivations (negative BOLD), with average amplitudes of 4.1% and −2.4%, respectively. Finally, the first high-resolution (500 μm in-plane) images of cerebral blood flow in the anesthetized monkey are presented. On functional activation we observed flow increases of up to 38% (59 to 81 ml/100 g/min) in the primary visual cortex, V1. Compared to BOLD maps, functional CBF maps were found to be localized entirely within the gray matter, providing unequivocal evidence for high spatial specificity. The exquisite sensitivity of the system and the increased specificity of the hemodynamic signals promise further insights into the relationship of the latter to the underlying physiological activity.  相似文献   

10.
ObjectiveAlfaxalone has been used increasingly in biomedical research and veterinary medicine of large animals in recent years. However, its effects on the cerebral blood flow (CBF) physiology and intrinsic neuronal activity of anesthetized brains remain poorly understood.MethodsFour healthy adult rhesus monkeys were anesthetized initially with alfaxalone (0.125 mg/kg/min) or ketamine (1.6 mg/kg/min) for 50 min, then administrated with 0.8% isoflurane for 60 min. Heart rates, breathing beats, and blood pressures were continuously monitored. CBF data were collected using pseudo-continuous arterial spin-labeling (pCASL) MRI technique and rsfMRI data were collected using single-shot EPI sequence for each anesthetic.ResultsBoth the heart rates and mean arterial pressure (MAP) remained more stable during alfaxalone infusion than those during ketamine administration. Alfaxalone reduced CBF substantially compared to ketamine anesthesia (grey matter, 65 ± 22 vs. 179 ± 38 ml/100g/min, p<0.001; white matter, 14 ± 7 vs. 26 ± 6 ml/100g/min, p < 0.05); In addition, CBF increase was seen in all selected cortical and subcortical regions of alfaxalone-pretreated monkey brains during isoflurane exposure, very different from the findings in isoflurane-exposed monkeys pretreated with ketamine. Also, alfaxalone showed suppression effects on functional connectivity of the monkey brain similar to ketamine.ConclusionAlfaxalone showed strong suppression effects on CBF of the monkey brain.The residual effect of alfaxalone on CBF of isoflurane-exposed brains was evident and monotonous in all the examined brain regions when used as induction agent for inhalational anesthesia. In particular, alfaxalone showed similar suppression effect on intrinsic neuronal activity of the brain in comparison with ketamine. These findings suggest alfaxalone can be a good alternative to veterinary anesthesia in neuroimaging examination of large animal models. However, its effects on CBF and functional connectivity should be considered.  相似文献   

11.
The changes of the regional cerebral blood volume (rCBV) with age were studied using dynamic susceptibility contrast MRI (DSC). We examined an unselected, random sample of 71 consecutive patients referred for work-up of suspected intracranial tumors (35 normal examinations, 36 tumors) with a standard 1.5 T clinical MR system. Determination of the rCBV was performed with a T21-weighted simultaneous dual (SD) FLASH sequence (TR/TE1/TE2/α = 32/25/16/10°, 55 images) after bolus injection of Gd-DTPA. Absolute quantification of the rCBV was achieved by normalizing the measured tissue concentration-time curves with the integrated arterial input function (AIF), which was simultaneously measured in the brain feeding arteries. The rCBV (mean ± SD) was 8.4 ± 2.9 ml/100 g and 4.2 ± 1.7 ml/100 g in gray and white matter, respectively, with a decline of about 3% and 6% per decade for white and gray matter, respectively. We conclude that DSC using a SD FLASH sequence allows the simultaneous measurement of the AIF and the tissue concentration-time curve and thus an absolute quantification of the rCBV, which is the basis for interperson comparisons and follow-up studies.  相似文献   

12.
The implications of changing the echo time of a gradient-echo echo planar imaging sequence applied to dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) for perfusion imaging at 3T were investigated. Four echo times in the range of 21 to 45 ms were examined in a total of 17 patients who received a dose of 0.1 mmol/kg bodyweight Gadobutrol (Gadovist, 1.0 mmol/ml). As the primary optimization parameter, the concentration-to-noise ratio (SNRc) was selected as it takes effects of variations in baseline as well as in signal drop into account. In an analysis of gray matter, white matter and arterial regions of interest, SNRc showed the highest values for the shortest applied echo time in all cases. Maps of regional cerebral blood volume (rCBV) and blood flow (rCBF) were calculated using deconvolution based on singular value decomposition. The quality of rCBF and rCBV images was judged to be good or excellent in all cases, independent of the echo time. Calculated gray matter/white matter ratios of rCBF and rCBV displayed no significant dependence on the applied echo time. Considering the better SNRc and arterial signal saturation aspects, we found that the shortest investigated echo time was the superior one. We thus suggest that short echo times should be applied, taking technical limitations and clinical demands into consideration.  相似文献   

13.
Accurate and noninvasive quantification of regional cerebral blood perfusion (CBF) of the human brain tissue would advance the study of the complex interplay between human brain structure and function, in both health and disease. Despite the plethora of works on CBF in gray matter, a detailed quantitative white matter perfusion atlas has not been presented on healthy adults using the International Consortium for Brain Mapping atlases. In this study, we present a host of assurance measures such as temporal stability, spatial heterogeneity and age effects of regional and global CBF in selected deep, cortical gray matter and white matter tracts identified and quantified using diffusion tensor imaging (DTI). We utilized whole brain high-resolution DTI combined with arterial spin labeling to quantify regional CBF on 15 healthy adults aged 23.2–57.1 years. We present total brain and regional CBF, corresponding volume, mean diffusivity and fractional anisotropy spatial heterogeneity, and dependence on age as additional quality assurance measures to compare with published trends using both MRI and nuclear medicine methods. Total CBF showed a steady decrease with age in gray matter (r=?0.58; P= .03), whereas total CBF of white matter did not significantly change with age (r= 0.11; P= .7). This quantitative report offers a preliminary baseline of CBF, volume and DTI measurements for the design of future multicenter and clinical studies utilizing noninvasive perfusion and DT-MRI.  相似文献   

14.
The aim of the present investigation was to determine spin lock (SL) relaxation parameters for the normal brain tissues and thus, to provide basis for optimizing the imaging contrast at 0.1 T. 68 healthy volunteers were included. On-resonance spin lock relaxation time (T) and off-resonance spin lock relaxation parameters (Toff, Me/Mo), MT parameters (T1sat, Ms/Mo), and T1, T2 were determined for the cortical gray matter, and for the frontal and parietal white matters. The T for the frontal and parietal white matters ranged from 110 to 133 ms and from 122 to 155 ms with locking field strengths from 50 μT to 250 μT, respectively. Accordingly, the values for the gray matter ranged from 127 to 155 ms. With a locking field strength of 50 μT, Toff for the frontal and parietal white matters were from 114 to 217 ms and from 126 to 219 ms, and for the gray matter from 136 to 267 ms with the angle between the effective magnetic field (Beff) and the z-axis (θ) ranging from 60° to 15°, respectively. The T of the white and gray matters increased significantly with increasing locking field amplitude (p < 0.001). The Toff decreased significantly with increasing θ (p < 0.001). T and Toff with θ ≥ 30° were statistically significantly shorter in the frontal than in the parietal white matters (p < 0.05). The duration, amplitude and θ of the locking pulse provide additional parameters to optimize contrast in brain SL imaging.  相似文献   

15.
Relative cerebral blood volume (CBV) was estimated using a mild hypoxic challenge in humans, combined with BOLD contrast gradient-echo imaging at 3 T. Subjects breathed 16% inspired oxygen, eliciting mild arterial desaturation. The fractional BOLD signal change induced by mild hypoxia is expected to be proportional to CBV under conditions in which there are negligible changes in cerebral perfusion. By comparing the regional BOLD signal changes arising with the transition between normoxia and mild hypoxia, we calculated CBV ratios of 1.5±0.2 (mean±S.D.) for cortical gray matter to white matter and 1.0±0.3 for cortical gray matter to deep gray matter.  相似文献   

16.
Arterial spin labeling (ASL) is a noninvasive technique that can measure cerebral blood flow (CBF). To our knowledge, there is no study that examined regional CBF of multiple sclerosis (MS) patients by using this technique. The present study assessed the relationship between clinical presentations and functional imaging data in MS using pseudocontinuous arterial spin labeling (pCASL). Twenty-seven patients with MS and 24 healthy volunteers underwent magnetic resonance imaging and pCASL to assess CBF. Differences in CBF between the two groups and the relationships of CBF values with the T2-hyperintense volume were evaluated. Compared to the healthy volunteers, reduced CBF was found in the bilateral thalami and right frontal region of the MS patients. The volume of the T2-hyperintense lesion was negatively correlated with regional CBF in some areas, such as both thalami. Our results suggest that demyelinated lesions in MS mainly have a remote effect on the thalamus and that the measurement of CBF using ASL could be an objective marker for monitoring disease activity in MS.  相似文献   

17.
Denoising is critical to improving the quality and stability of cerebral blood flow (CBF) quantification in arterial spin labeled (ASL) perfusion magnetic resonance imaging (MRI) due to the intrinsic low signal-to-noise-ratio (SNR) of ASL data. Previous studies have been focused on reducing the spatial or temporal noise using standard filtering techniques, and less attention has been paid to two global nuisance effects, the residual motion artifacts and the global signal fluctuations. Since both nuisances affect the whole brain, removing them in advance should enhance the CBF quantification quality for ASL MRI. The purpose of this paper was to assess this potential benefit. Three methods were proposed to suppress each or both of the two global nuisances. Their performances for CBF quantification were validated using ASL data acquired from 13 subjects. Evaluation results showed that covarying out both global nuisances significantly improved temporal SNR and test-retest stability of CBF measurement. Although the concept of removing both nuisances is not technically novel per se, this paper clearly showed the benefits for ASL CBF quantification. Dissemination of the proposed methods in a free ASL data processing toolbox should be of interest to a broad range of ASL users.  相似文献   

18.
PurposeTo investigate the utility of diffusion-weighted arterial spin labeling (DW-ASL) for detecting the progression of brain white matter lesions.Materials and methodsA total of 492 regions of interest (ROIs) in 41 patients were prospectively analyzed. DW-ASL was performed using the diffusion gradient prepulse of five b-values (0, 25, 60, 102, and 189) before the ASL readout. We calculated the water exchange rate (Kw) with post-processing using the ASL signal information for each b-value. The cerebral blood flow (CBF) was also calculated using b0 images. Using the signal information in FLAIR (fluid-attenuated inversion recovery) images, we classified the severity of white matter lesions into three grades: non-lesion, moderate, and severe. In addition, the normal Kw level was measured from DW-ASL data of 60 ROIs in five control subjects. The degree of variance of the Kw values (Kw-var) was calculated by squaring the value of the difference between each Kw value and the normal Kw level. All patient's ROIs were divided into non-progressive and progressive white matter lesions by comparing the present FLAIR images with those obtained 2 years before this acquisition.ResultsCompared to the non-progressive group, the progressive group had significantly lower CBF, significantly higher severity grades in FLAIR, and significantly greater Kw-var values. In a receiver operator characteristic curve analysis, a high area under the curve (AUC) of 0.89 was obtained with the use of Kw-var. In contrast, the AUCs of 0.59 for CBF and 0.72 for severity grades in FLAIR were obtained.ConclusionsThe DW-ASL technique can be useful to detect the progression of brain white matter lesions. This technique will become a clinical tool for patients with various degrees of white matter lesions.  相似文献   

19.
Because mouse may relatively easily be genetically tailored to develop equivalent of human muscular diseases or to present controlled alterations of mechanisms involved in vasoregulation, it has become the prevalent species to explore such questions. However, the very small size of the animals represents a serious limitation when evaluating the functional consequences of these genetic manipulations. In this context, the recourse to arterial spin labeling (ASL) nuclear magnetic resonance (NMR) methods in which arterial water spins act as an endogenous and freely diffusible tracer of perfusion is tempting but challenging. This article shows that despite the small size of the animal, mouse muscle perfusion may be measured, at rest and in conditions of reactive hyperemia, using saturation inversion recovery sequence, a pulsed ASL variant, combined with NMR imaging. Baseline perfusion values in the mouse leg were 17+/-11 ml.min(-1).100 g(-1) (n=11) and were comparable to microsphere data from the literature. Under ischemia, leg perfusion was 1.2+/-9.3 ml.min(-1).100 g(-1) (n=11). The difference observed between basal and ischemic measurements was statistically different (P=.0001). The temporal pattern of hyperemia in mouse muscle was coherent with previously published measurements in humans and in rats. The mean peak perfusion was 62+/-24 ml.min(-1).100 g(-1) (n=6) occurring 48+/-27 s after the end of occlusion. In conclusion, this study demonstrated the ability of ASL combined to NMR imaging to quantify skeletal muscle perfusion in mice legs, both at rest and dynamically.  相似文献   

20.
Three-dimensional (3D) magnetic resonance imaging (MRI) has shown great potential for studying the impact of prematurity and pathology on brain development. We have investigated the potential of optimized T1-weighted 3D magnetization-prepared rapid gradient-echo imaging (MP-RAGE) for obtaining contrast between white matter (WM) and gray matter (GM) in neonates at 3 T. Using numerical simulations, we predicted that the inversion time (TI) for obtaining strongest contrast at 3 T is approximately 2 s for neonates, whereas for adults, this value is approximately 1.3 s. The optimal neonatal TI value was found to be insensitive to reasonable variations of the assumed T1 relaxation times. The maximum theoretical contrast for neonates was found to be approximately one third of that for adults. Using the optimized TI values, MP-RAGE images were obtained from seven neonates and seven adults at 3 T, and the contrast-to-noise ratio (CNR) was measured for WM versus five GM regions. Compared to adults, neonates exhibited lower CNR between cortical GM and WM and showed a different pattern of regional variation in CNR. These results emphasize the importance of sequence optimization specifically for neonates and demonstrate the challenge in obtaining strong contrast in neonatal brain with T1-weighted 3D imaging.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号