 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive, selective, specific and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric assay method was developed and validated for the simultaneous quantitation of alpha-,beta-arteether (alpha-,beta-AE) and its metabolite alpha-dihydroartemisinin (DHA) in monkey plasma using the propyl ether analogue of beta-arteether (PE) as an internal standard. The method involves a simple two-step liquid-liquid extraction with hexane. The analytes were chromatographed on a C(18) reversed-phase chromatographic column by isocratic elution with methanol-ammonium acetate buffer (pH 4) (92 : 8, v/v) and analysed by mass spectrometry in the multiple reaction monitoring mode. The chromatographic run time was 7 min and the weighted (1/x(2)) calibration curves were linear over the range 0.78-200 ng ml(-1). The method was validated in terms of accuracy, precision, absolute recovery, freeze-thaw stability, bench-top stability and re-injection reproducibility. The limit of detection and lower limit of quantification in monkey plasma were 0.39 and 0.78 ng ml(-1) respectively for all the analytes. The intra- and inter-batch precision and accuracy were found to be well within acceptable limits (<15%). All three analytes were stable even after three freeze-thaw cycles (deviation < 15%). The average absolute recoveries of alpha-,beta-AE, DHA and PE, used as an internal standard, from spiked plasma samples were 85.85 +/- 6.56, 70.10 +/- 7.06, 54.37 +/- 3.39 and 93.90 +/- 6.9%, respectively. The assay method described here could be applied to study the pharmacokinetics of alpha-,beta-AE and DHA in rhesus monkeys.  相似文献   

2.
A highly sensitive liquid chromatographic-tandem mass spectrometric method (LC-MS-MS) is developed to quantitate ranolazine in human plasma. The analyte and internal standard tramadol are extracted from plasma by liquid-liquid extraction using diethyl ether-dichloromethane (60:40 v/v), and separated on a Zorbax extend C(18) column using methanol-10mM ammonium acetate (60:40 v/v, pH 4.0) at a flow of 1.0 mL/min. Detection is carried out by multiple reaction monitoring on a QtrapTM LC-MS-MS system with an electrospray ionization interface. The assay is linear over the range 10-5000 ng/mL with a limit of quantitation of 10 ng/mL and a lower limit of detection (S/N > 3) of 1 ng/mL. Intra- and inter-day precision are < 3.1% and < 2.8%, respectively, and the accuracy is in the range 96.7-101.6%. The validated method is successfully used to analyze the drug in samples of human plasma for pharmacokinetic studies.  相似文献   

3.
A simple, sensitive and rapid ultra-performance liquid chromatography/positive electrospray ionization tandem mass spectrometry (UPLC/ESI-MS/MS) method has been developed and validated for the determination of lercanidipine in human plasma. Lercanidipine and the internal standard, nicardipine, were extracted from plasma by liquid-liquid extraction using tert-butyl methyl ether as the extraction solvent. UPLC analysis was performed isocratically on an AcQuity UPLC BEH C18 analytical column (2.1 x 50.0 mm i.d., particle size 1.7 microm). The mobile phase consisted of 70% acetonitrile in water containing 0.2% v/v formic acid and pumped at a flow rate of 0.30 mL/min. ESI in positive ion mode, with multiple reaction monitoring (MRM), was chosen for the detection of the analytes. The assay was linear over a concentration range of 0.05-30 ng/mL for lercanidipine with a limit of quantitation of 0.05 ng/mL. Quality control samples (0.05, 0.15, 15 and 25 ng/mL) in five replicates from five of analytical runs demonstrated intra-assay precision (% CV < or =7.3%), inter-assay precision (% CV < or =6.1%) and an overall accuracy (% relative error) of less than 6.2%. A run time of less than 1.0 min for each sample made it possible to analyze a large number of human plasma samples per day. The method can be used to quantify lercanidipine in human plasma covering a variety of pharmacokinetic or bioequivalence studies.  相似文献   

4.
A method for the determination of artemether (ART) and its main metabolite dihydroartemisinin (DHA) in plasma employing liquid-phase microextraction (LPME) for sample preparation prior to liquid chromatography-tandem mass spectrometry (LC-MS-MS) was developed. The analytes were extracted from 1 mL of plasma utilizing a two-phase LPME procedure with artemisinin as internal standard. Using the optimized LPME conditions, mean absolute recovery rates of 25 and 32% for DHA and ART, respectively, were achieved using toluene-n-octanol (1:1, v/v) as organic phase with an extraction time of 30 min. After extraction, the analytes were resolved within 5 min using a mobile phase consisting of methanol-ammonium acetate (10 mmol L−1, pH 5.0, 80:20, v/v) on a laboratory-made column based on poly(methyltetradecylsiloxane) attached to a zirconized-silica support. MS-MS detection was employed using an electrospray interface in the positive ion mode. The method developed was linear over the range of 5-1000 ng mL−1 for both analytes. Precision and accuracy were within acceptable levels of confidence (<15%). The assay was applied to the determination of these analytes in plasma from rats treated with ART. The two-phase LPME procedure is affordable and the solvent consumption was very low compared to the traditional methods of sample preparation.  相似文献   

5.
A simple, specific and sensitive LC-MS/MS assay for simultaneous determination of simvastatin (SV) and its active beta-hydroxy acid metabolite, simvastatin acid (SVA) in human plasma was developed using a statin analog as internal standard (IS). The method was validated over a dynamic linear range of 0.20-100.00 ng/mL for SV and 0.10-50.00 ng/mL for SVA with correlation coefficient r > or = 0.9987 and 0.9989, respectively. The analytes and IS were extracted from 500 microL aliquots of human plasma via liquid-liquid extraction using methyl tert-butyl ether and separated through an Aquasil C18 column (100 mm x 2.1 mm, 5 microm). Detection of analytes and IS was done by MS/MS with a turbo ion spray interface operating in positive ion and selective reaction monitoring acquisition mode. The total chromatographic run time was 3.0 min. Flash freezing of the aqueous phase was an added advantage during liquid-liquid extraction, which considerably reduced time and labour. The method was extensively validated for its accuracy, precision, recovery, stability studies and matrix effect. The method was successfully used for bioequivalence study of 40 mg SV tablet formulation in 12 human subjects under fasting condition.  相似文献   

6.
A liquid chromatography-tandem mass spectrometric (LC/MS/MS) method for the determination of a new ox-azolidinone antibiotic DA-7867, (S)-[N-3-(4-(2-(1-methyl-5-tetrazolyl)-pyridine-5-yl)-3- fl uorophenyl)-2-oxo-5-oxazolidinyl]methyl acetamide, in human plasma was developed. DA-7867 and internal standard, linezolid, were extracted from human plasma with ethyl acetate at acidic pH. A reverse-phase LC separation was performed on Luna C(8) column with the mixture of acetonitrile-ammonium formate (10 mm, pH 4.5; 35:65, v/v) as mobile phase. The analytes were determined using an electrospray ionization tandem mass spectrometry in the multiple-reaction-monitoring mode. The lower limits of quanti fi cation for DA-7867 was 2.5 ng/mL. The single liquid-liquid extraction quantitatively recovered DA-7867 and internal standard from plasma samples at the ranges of 82.2-86.7%. DA-7867 was stable in blank human plasma at room temperature for 24 h and following three freeze-thaw cycles.  相似文献   

7.
A high‐performance liquid chromatographic assay with tandem mass spectrometric detection was developed to simultaneously quantify fluoxetine and olanzapine in human plasma. The analytes and the internal standard (IS) duloxetine were extracted from 500 μL aliquots of human plasma through solid‐phase extraction. Chromatographic separation was achieved in a run time of 4.0 min on a Hypersil Gold C18 column (50 × 4.6 mm, 5 µm) using isocratic mobile phase consisting of acetonitrile–water containing 2% formic acid (70:30, v/v), at a flow‐rate of 0.5 mL/min. Detection of analytes and internal standard was performed by electrospray ionization tandem mass spectrometry, operating in positive‐ion and multiple reaction monitoring acquisition mode. The protonated precursor to product ion transitions monitored for fluoxetine, olanzapine and IS were m/z 310.01 → 147.69, 313.15 → 256.14 and 298.1 → 153.97, respectively. The method was validated over the concentration range of 1.00–150.20 ng/mL for fluoxetine and 0.12–25.03 ng/mL for olanzapine in human plasma. The intra‐batch and inter‐batch precision (%CV) across four quality control levels was ≤6.28% for both the analytes. In conclusion, a simple and sensitive analytical method was developed and validated in human plasma. This method is suitable for measuring accurate plasma concentration in bioequivalence study and therapeutic drug monitoring as well, following combined administration. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

8.
A highly sensitive and selective LC-ESI-MS was developed, validated for the simultaneous determination of 18alpha-glycyrrhetic acid (alpha-GA) and 18beta-glycyrrhetic acid (beta-GA) for pharmacokinetic studies in healthy subjects. Sample preparation was performed by liquid-liquid extraction with ethyl acetate and the separations were achieved using a C(18) column with the mobile phase composed of 10 mmol/L ammonium acetate solution-methanol-acetonitrile (40:36:24, v/v/v) at a flow rate of 1 mL/min. The internal standard was honokiol and the epimers were quantified using a single quadrupole mass spectrometer employing ESI in the negative ion mode. The separation factor, alpha, was 1.512 for alpha- and beta-GA. The standard curves were linear for both epimers with coefficients of determination (r >or= 0.9998) over the concentration range of 1-150 ng/mL. The precision and accuracy were 相似文献   

9.
A selective, rapid and simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) method is described for assay of donepezil in human plasma using escitalopram as an internal standard. Chromatographic separation was achieved on a Betabasic-C(8), 5 microm, 100 x 4.6 mm column using methanol:water:formic acid (90:9.97:0.03, v/v/v) as mobile phase. Detection of donepezil and internal standard was achieved by ESI MS/MS in positive ion mode using 380.20/91.10 and 325.13/262.00 transitions, respectively. The linearity over the concentration range of 0.15-50 ng/mL for donepezil was obtained and the lower limit of quantification was 0.15 ng/mL. For each level of quality control samples, inter-day and intra-day precisions (RSD) were < or =8.92 and 10.35% and accuracy (%RE) were < or =7.33% and 9.33%, respectively. The recovery was more than 88.50% for both donepezil and internal standard by solid-phase extraction, eliminating evaporation and reconstitution steps.  相似文献   

10.
Diosmetin, 3',5,7-trihydroxy-4'-methoxy flavone, is the aglycone of the flavonoid glycoside diosmin that occurs naturally in foods of plant origin. Diosmin exhibits antioxidant and anti-inflammatory activities, improves venous tone and it is used for the treatment of chronic venous insufficiency. Diosmin is hydrolyzed by enzymes of intestinal micro flora before absorption of its aglycone diosmetin. A specific, sensitive, precise, accurate and robust HPLC assay for the determination of diosmetin in human plasma was developed and validated. Diosmetin and the internal standard 7-ethoxycoumarin were isolated from plasma by liquid-liquid extraction and separated on a C8 reversed-phase column with methanol-water-acetic acid (55:43:2, v/v/v) as the mobile phase at 43 degrees C. Peaks were monitored at 344 nm. The method was linear in the 10-300 ng/mL concentration range (r > 0.999). Recovery for diosmetin and internal standard was greater than 89.7 and 86.8%, respectively. Intra-day and inter-day precision for diosmetin ranged from 1.6 to 4.6 and from 2.2 to 5.3%, respectively, and accuracy was better than 97.9%.  相似文献   

11.
A rapid and sensitive LC-MS assay was developed and validated for the simultaneous determination of d7-nefazodone (d7-NEF), nefazodone (NEF), d7-hydroxynefazodone (d7-OH-NEF), hydroxynefazodone (OH-NEF), m-chlorophenylpiperazine (mCPP), and triazole-dione (Dione) in human plasma using trazodone (TRZ) as the internal standard (IS). A 0.1 mL aliquot of the plasma sample was precipitated with 0.1 mL of acetonitrile and vortexed for 2 min. After centrifugation, 50 microL of supernatant was mixed with 100 microL of 10 mM ammonium formate (pH = 4.0), and a 50 microL aliquot was injected onto a BDS Hypersil C18 column at a flow rate of 0.3 mL/min. The mobile phase consisting of 10 mM ammonium formate (pH = 4) and acetonitrile, 55:45 v/v, was used in an isocratic system. The mass spectrometer was programmed to admit the protonated molecules at m/z 477.2 (d7-NEF), 493.3 (d7-OH-NEF), 197.0 (mCPP), 372.0 (IS), 470.4 (NEF), 458.0 (Dione) and 486.2 (OH-NEF). Standard curves were linear (r(2) >/= 0.994) over the concentration range of 4-1000 ng/mL for Dione and 2-500 ng/mL for all other analytes. The lowest standard concentrations were the lower limits of quantitation for each analyte. The mean predicted quality control concentrations for all analytes deviated by less than 14.3% from the corresponding nominal values; the intra-assay and inter-assay precisions of the assay for all analytes were within 10.5% relative standard deviation. All analytes including the internal standard were stable in the injection solvent at room temperature for at least 24 h. The extraction recovery of the various analytes ranged from 79.2 to 109.1%. The validated assay was applied to the analysis of clinical samples obtained from a human subject who simultaneously received d7-NEF and NEF orally.  相似文献   

12.
An improved assay for the determination of rofecoxib in human plasma samples is described. The analyte and an internal standard were extracted from the plasma matrix using solid-phase extraction in the 96-well format with an Empore C8-SD extraction plate. The analytes are chromatographed on a Waters Symmetry C18 analytical column (3.5 microm, 50x4.6 mm) with a mobile phase consisting of acetonitrile-water (35:65, v/v). Analyte detection was via fluorescence following post-column photochemical derivatization. Eight point calibration curves over the concentration range of 0.5-80 ng/ml yielded a linear response when a 1/y weighted linear regression model was employed. Based on the replicate analyses (n=5) of spiked standards, the within-day assay precision was better than 8% RSD at all points on the calibration curve, within-day accuracy was within 6% of nominal at all standard concentrations. The between-run precision and accuracy of the assay, as calculated from the results of the analysis of quality control samples, was better than 7% RSD and within 5% of nominal. Assay throughput was improved by a factor of three as compared to previously described methods. The method was partially automated using a combination of a Packard Multi-Probe liquid handling system and a TomTec Quadra 96 workstation.  相似文献   

13.
A simple, sensitive and rapid liquid-liquid extraction method for the analysis of nicotinic acid (niacin) and its labeled internal standard nicotinic acid-d4 (niacin-d4) in human plasma was developed and validated. The analyte and its internal standard were isolated from acidified plasma using a single liquid-liquid extraction procedure with methyl-t-butyl ether. The extracted samples were analyzed by liquid chromatography-tandem mass spectrometry in positive electrospray ionization mode with multiple reaction monitoring. The calibration curves were linear in the measured range between 5 and 1000 ng/mL and the limit of detection was calculated as 122 pg/mL. The method required 250 microL of human plasma and the total run time between injections was 3.5 min. Matrix effects were assessed by post-column infusion experiments, phospholipids monitoring and post-extraction addition experiments. The extraction of phospholipids and niacin from plasma was studied under acidic, neutral and basic conditions. Acidic conditions were optimal for both the recovery of niacin and the removal of phospholipids; the degree of matrix effects for niacin was determined to be 2.5%. It was concluded that effective removal of matrix components can overcome low recovery issues associated with liquid-liquid extractions of polar analytes.  相似文献   

14.
High-performance liquid chromatographic assay procedures have been developed for naproxen, ibuprofen and diclofenac in human plasma and synovial fluid samples. A single liquid-liquid extraction procedure was used to isolate each compound from acidified biological matrix prior to the quantitative analysis. A Spherisorb ODS column (12.5 cm x 4.6 mm I.D.) was used for all the chromatography. Naproxen was eluted with a mobile phase of methanol-S?rensen's buffer at pH 7 (37:63, v/v). Ibuprofen and diclofenac were eluted using mobile phases of methanol-water at pH 3.3 (65:35, v/v and 63:37, v/v, respectively). Diphenylacetic acid was used as the internal standard for the assay of naproxen and flurbiprofen was used in the analysis of ibuprofen and diclofenac. Inter- and intra-day coefficients of variation were less than 7%. The assays were used in clinical studies of the three drugs in osteo- and rheumatoid arthritis patients.  相似文献   

15.
A simple, sensitive and rapid high-performance liquid chromatography/positive electrospray ionization tandem mass spectrometry method was developed and validated for the assay of clopidogrel in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by mass spectrometry in the multiple reaction monitoring mode using the respective [M+H](+) ions, m/z 322/212 for clopidogrel and m/z 264/154 for the internal standard. The assay exhibited a linear dynamic range of 5-6000 pg/mL for clopidogrel in human plasma. The lower limit of quantification was 5 pg/mL with a relative standard deviation of less than 8%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.5 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

16.
A simple, rapid, sensitive, and selective liquid chromatography-tandem mass spectrometry method is developed and validated for the quantitation of galantamine, an acetylcholinesterase inhibitor in human plasma, using a commercially available compound, loratadine, as the internal standard. Following liquid-liquid extraction, the analytes are separated using an isocratic mobile phase on a reverse-phase C18 column and analyzed by mass spectrometry in the multiple reaction monitoring mode using the respective (M+H)+ ions, m/z 288 to 213 for galantamine and m/z 383 and 337 for the internal standard. The assay exhibit a linear dynamic range of 0.5-100 ng/mL for galantamine in human plasma. The lower limit of quantitation is 0.5 ng/mL, with a relative standard deviation of less than 8%. Acceptable precision and accuracy are obtained for concentrations over the standard curve range. A run time of 2.5 min for each sample makes it possible to analyze more than 400 human plasma samples per day. The validated method is successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability, or bioequivalence studies.  相似文献   

17.
张晓艺  张秀尧  蔡欣欣  李瑞芬 《色谱》2020,38(5):564-571
建立了超高效液相色谱-三重四极杆质谱测定血浆、尿液和瓜果类蔬菜中葫芦素B、E和I的检测方法。血浆和尿液样品经固相支持液液萃取法(SLE)提取净化,瓜果类蔬菜样品经乙腈提取后用水稀释。以XBridge BEH C18色谱柱(100 mm×3.0 mm,2.5 μm)为分析柱进行分离,以甲醇-0.025%(v/v)氨水溶液为流动相进行梯度洗脱。采用大气压化学电离源,在负离子、多反应监测(MRM)模式下检测,以夹竹桃甙作为内标物,基质工作曲线内标法定量血浆和尿液中3种葫芦素;以溶剂标准曲线外标法定量瓜果类蔬菜中的待测物。血浆和尿液中3种葫芦素的检出限均为0.03 μg/L,平均加标回收率为89.0%~113%,相对标准偏差为1.7%~12.2%(n=6);瓜果类蔬菜中3种葫芦素的检出限为5~10 μg/kg,平均加标回收率为87.6%~114%,相对标准偏差为4.1%~11.1%(n=6)。该法简单、灵敏、准确,已应用于食用苦葫芦瓜引起中毒的病人血浆和尿液,以及葫芦瓜的检测,并检出了葫芦素B。  相似文献   

18.
A high-performance liquid chromatographic method for the determination of picotamide in human plasma and urine is described. After addition of an internal standard (bamifylline), the plasma and urine samples were subjected to liquid-liquid extraction and clean-up procedures. The final extracts were evaporated to dryness and the resulting residues were reconstituted in 100 microliters of methanol-water (50:50, v/v) and chromatographed on a LiChrosorb RP-SELECT B reversed-phase column coupled to an ultraviolet detector monitored at 230 nm. Chromatographic analysis takes about 10 min per sample. The assay was linear over a wide range and has a limit of detection of 0.005 and 0.1 micrograms/ml in plasma and urine, respectively. It was selective for picotamide, accurate and robust and thus suitable for routine assays after therapeutic doses of picotamide.  相似文献   

19.
A sensitive gas chromatographic-mass spectrometric (GC-MS) procedure is described for the selective determination of gacyclidine (a non-competitive N-methyl-D-aspartate antagonist) in rat plasma and spinal cord dialyzates. It involves a single-step liquid-liquid extraction of plasma samples and dialyzates with hexane (pH 8.0) and the use of phencyclidine as an internal standard. The compounds were separated on a GC capillary column and specifically detected by MS in the selected-ion monitoring mode. Gacyclidine and its internal standard were monitored by using the fragment ions at m/z 206 and 200, respectively. The method was accurate and reproducible (intra- and inter-day reproducibility < 12%) with a limit of quantification of 1.6 ng ml-1 using 100 microliters plasma of dialyzate samples. The calibration curves for rat plasma and Ringer's solution were linear (r2 > 0.996) over a range from 1.6 to 200 ng ml-1. The extraction efficiency was close to 100%. This simple and rapid assay (total run time < 10 min) was validated for a pilot pharmacokinetic study in healthy rats after intravenous injection of a bolus dose of gacyclidine (2.5 mg kg-1).  相似文献   

20.
A sensitive, rapid and specific quantitative liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated for the determination of apomorphine (APO) in canine plasma. The analytes were prepared using one-step liquid-liquid extraction, and analyzed on a Waters Symmetry C(18) column interfaced with triple quadrupole tandem mass spectrometer. A mixture of methanol/0.1% formic acid in water (70: 30, v/v) was employed as the isocratic mobile phase. Positive electrospray ionization was utilized as the ionization source. The analyte and clenbuterol (internal standard) were both detected using multiple reaction monitoring (MRM) mode. The limit of detection (LOD) obtained was 0.03 ng/mL. The assay was linear over the concentration range of 0.1-100 ng/mL, and provided good precision (RSD) and good accuracy (RE). The analyte was stable by using antioxidants throughout the whole study. The experimental results show that LC/MS/MS is a rapid and sensitive method to analyze APO in plasma. Finally, the proposed method was successfully applied to a pharmacokinetic study of APO after intranasal administration of 0.5 mg apomorphine to 10 healthy beagle dogs.  相似文献   