首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
《Electroanalysis》2003,15(10):898-902
A method based on capillary electrophoresis (CE) with electrochemical detection (ED) was developed for the determination of taurine in Lycium Barbarum L., LIPOVIYAN beverage and milk powder. The effects of some important factors such as the acidity of the running buffer, separation voltage, injection time, and applied potential to working electrode were investigated. Operated in a wall‐jet configuration, a 300 μm diameter carbon‐disk electrode was used as the working electrode, which exhibits good responses at +1.05 V (vs. SCE) for taurine. Excellent linearity was obtained in the concentration range from 5.0×10?4 mol/L to 5.0×10?6 mol/L. The detection limit (S/N=3) was 1.0×10?7 mol/L. This proposed method has been successfully applied to analyze the actual samples with satisfactory assay results.  相似文献   

2.
The method of capillary zone electrophoresis (CZE) with direct UV detection was developed for the determination of oleanolic acid, ursolic acid, quercetin and apigenin. and then for the first time successfully applied to the analysis of four analytes in Swertia mussotii Franch and its preparations. Various factors affecting the CZE procedure were investigated and optimized, and the optimal conditions were: 50 × 10?3 mol/L borate‐phosphate buffer (pH 9.5) with 5.0 × 10?3 mol/L β‐cyclodextrin, 15 kV separation voltage, 20 °C column temperature, 250 nm detection wavelength and 5 s electrokinetic injection time (voltage 20 psi). Under the conditions, oleanolic acid, ursolic acid, quercetin and apigenin could be determined within the test ranges with a good correlation coefficient (r2 > 0.9991). The limits of detection for conditions, oleanolic acid, ursolic acid, quercetin and apigenin were 0.3415, 0.2003, 0.0062 and 0.2538 µg/mL, respectively, and the intra‐ and inter‐day relative standard deviations were no more than 4.72%. This procedure provided a convenient, sensitive and accurate method for simultaneous determination of oleanolic acid, ursolic acid, quercetin and apigenin in S. mussotii Franch. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

3.
《Electroanalysis》2002,14(23):1674-1678
Capillary zone electrophoresis with catalysis‐electrochemical detection has been developed and applied to determining horseradish peroxidase (HRP) at zeptomole levels. In this method, an on‐line enzyme catalysis reactor with a reaction capillary was designed. Isoenzymes of HRP were separated by capillary zone electrophoresis, and then they catalyzed the enzyme substrate 3,3′,5,5′‐tetramethylbenzide (TMB(Red)) and H2O2 in the reaction capillary. The reaction product, TMB(Ox), could be determined using amperometric detection on a carbon fiber microdisk bundle electrode at the outlet of the reaction capillary. Because of enzyme amplification, a significant amount of TMB(Ox) could be produced for detection. Therefore, the limit of detection (LOD) of HRP is very low. The optimum conditions of the method are 1.5×10?2 mol/L borate (pH 7.4) for the run buffer, 2×10?3 mol/L for the concentration of H2O2, 2×10?4 mol/L TMB(Red)+2.0×10?2 mol/L citrate‐phosphate (pH 5.0) for the substrate solution, 40 cm for the liquid pressure height, 20 kV for the separation voltage, 100 mV for the detection potential. HRP could be measured with a detection limit of 4.8×10?12 mol/L or 47.5 zmol (S/N=3). The linear range is from 2.40×10?11 to 2.40×10?8 mol/L. Using this method, commercial HRP was measured at zeptomole within ten minutes.  相似文献   

4.
A simple, reliable and reproducible method, based on capillary zone electrophoresis with amperometric detection, has been developed for the determination of idarubicin in human urine. A carbon disk electrode was used as working electrode. The optimal conditions of separation and detection were pH 5.6 phosphate buffer ¶(0.20 mol/L), 22 kV for the separation voltage and 1.00 V (vs. Ag/AgCl, 3 mol/L KCl) for the detection potential. The linear range was from 4.0 × 10–7 to 2.0 × 10–5 mol/L with a regression coefficient of 0.9986, and the detection limit was 8.0 × 10–8 mol/L. The method was directly applied to the determination of idarubicin in spiked human urine without any other sample pretreatment except filtration, and the assay results were satisfactory.  相似文献   

5.
A new analytical methodology for the electrochemical detection of the herbicide maleic hydrazide (3,6‐dihydroxypyridazine) by flow injection analysis is presented. This method is supported by the novel application of a palladium‐dispersed carbon paste electrode as an amperometric sensor for this herbicide. Maleic hydrazide shows anodic electrochemical activity on carbon‐based electrodes (glassy carbon or carbon paste electrodes) in all the pH range. This electrochemical activity is enhanced using metal‐dispersed carbon paste electrodes, especially at Pd‐dispersed CPE which displays good oxidation signals at 690 mV (0.050 M phosphate buffer pH 7.0), 140 mV lower than at unmodified electrodes. Under the optimized conditions, the electroanalytical performance of Pd‐dispersed CPE in flow injection analysis was excellent, with good reproducibility (RSD 3.3%) and a wide linear range (1.9×10?7 to 1.0×10?4 mol L?1). A detection limit of 1.4×10?8 mol L?1 (0.14 ng maleic hydrazide) was obtained for a sample loop of 100 μL at a fixed potential of 700 mV in 0.050 M phosphate buffer solution at pH 7.0 and a flow rate of 2.0 mL min?1. The proposed method was applied for the maleic hydrazide detection in natural drinking water samples.  相似文献   

6.
采用毛细管电泳-电化学检测法(CE-ED)同时分离测定了中药杠板归中的阿魏酸、香草酸、槲皮素、咖啡酸、原儿茶酸等主要生物活性成分的含量。考察了工作电极电位、运行缓冲液的pH值和浓度、分离电压和进样时间等实验参数对实验结果的影响。在优化的实验条件下,以直径300 μm的碳圆盘电极为工作电极,检测电位为+0.95V(vs. SCE),在10mmol/L磷酸盐(pH 9.2)的运行缓冲溶液中,五个分析物能够在17min内实现很好的基线分离,被测物浓度与峰电流在3个数量级呈良好的线性,检测限(S/N=3)范围从7.1×10-8 到 9.3×10-8g mL-1。该方法已应用于实际样品的分析,样品处理简单,获得了令人满意的结果。  相似文献   

7.
《Analytical letters》2012,45(6):1165-1173
Abstract

The polarographic behavior of the complex of iron–4– (2–pyridylazo) resorcin(PAR) was studied. In HAc– NaAc– EDTA buffer solution, the complex can be adsorped on a hanging mercury drop electrode giving a sensitive adsorptive complex reduction peak with a peak potential at -0.36V(vs. SCE). Optimum experimental conditions were found by the use of 0.08mol/L HAc, 0.06mol/L NaAc, 5.0 × 10?3mol/L EDTA and 1.0 × 10?5mol/L PAR. With preconcentration for 60s, the derivative peak height of the complex compound is linearly proportional to the concentration for Fe in the range from 1.0 × 10?9mol/L to 1.0 × 10?7mol/L. For a 2–min pre–concentration time, the detection limit found was 2.0 × 10?10mol/L. This method has high sensitivity and selectivity. It has been applied to the determination of trace iron in food and water samples without any pre–separation step.  相似文献   

8.
《Electroanalysis》2004,16(9):774-778
A method for indirectly detecting yoctomole (ymol) alkaline phosphatase was developed by capillary electrophoresis with electrochemical detection. In this method, disodium phenyl phosphate was used as the enzyme substrate and the product (phenol) of its hydrolysis reaction catalyzed by alkaline phosphatase was detected at the carbon fiber electrode. The optimum conditions of detection are 1.0×10?2 mol/L Na2B4O7 (pH 9.8) for the running buffer; 1.00×10?3 mol/L disodium phenyl phosphate for the enzyme substrate; 20.0 kV for the separation voltage; 5 kV and 10 s for the injection voltage and injection time; 1.05 V (vs. saturated calomel electrode) for the detection potential and 10 min for the incubation time, respectively. In order to enhance the ratio of signal to noise, the shape and size of the working electrode, the shape of detection end of the capillary, and the capillary/electrode alignment method were studied in detail. When a single carbon fiber microcylinder electrode of 6 μm, a capillary of 10 μm ID with the etched detection end and the in‐capillary alignment were used, a ymol mass limit of detection for alkaline phosphatase was achieved.  相似文献   

9.
The fast separation capability of a novel miniaturized capillary electrophoresis with an amperometric detection (μCE‐AD) system was demonstrated by determining clenbuterol and salbutamol in real samples. The effects of several factors such as the acidity and concentration of the running buffer, the separation voltage, the applied potential and the injection time on CE‐AD were examined and optimized. Under the optimum conditions, the two β‐agonists could be baseline separated within 60 s at a separation voltage of 2 kV in a 90 mmol/L H3BO3‐Na2B4O7 running buffer (pH 7.4), which was not interfered by ascorbic acid and uric acid. Highly linear response was obtained for above compounds over three orders of magnitude with detection limits ranging from 1.20×10?7 to 6.50×10?8 mol/L (S/N=3). This method was successfully used in the analysis of feed and meat products with relatively simple extraction procedures.  相似文献   

10.
A capillary electrophoresis coupled with tris(2,2′‐bipyridyl) ruthenium(II) (Ru(bpy)32+) electrochemiluminescence detection system was developed to determine salbutamol and clenbuterol in urine. Some factors that affected the performances of separation and detection were investigated. Under the optimized conditions, one single quantitative analysis of salbutamol and clenbuterol was achieved at a separation voltage of 15 kV within 9 min, and the LODs (S/N=3) and LOQs (S/N=10) of salbutamol and clenbuterol were 8.43×10?8 mol/L, 2.61×10?7 mol/L and 2.73×10?7 mol/L, 8.21×10?7 mol/L, respectively. The recovery obtained from the analysis of spiked urine samples was between 88.6 % and 104.7 % with RSDs lower than 6.70 %. The method was successfully applied to determine salbutamol and clenbuterol in urine samples.  相似文献   

11.
Based on single‐walled carbon nanotubes (SWCNTs) modified glassy carbon electrode (GCE/SWCNTs), a novel method was presented for the determination of L ‐tyrosine. The GCE/SWCNTs exhibited remarkable catalytic and enhanced effects on the oxidation of L ‐tyrosine. In 0.10 mol/L citric acid‐sodium citrate buffer solution, the oxidation potential of L ‐tyrosine shifted negatively from +1.23 V at bare GCE to +0.76 V at GCE/SWCNTs. Under the optimized experimental conditions, the linear range of the modified electrode to the concentration of L ‐tyrosine was 5.0×10?6–2.0×10?5 mol/L (R1=0.9952) and 2.7×10?5–2.6×10?4 mol/L (R2=0.9998) with a detection limit of 9.3×10?8 mol/L. The kinetic parameters such as α (charge transfer coefficient) and D (diffusion coefficient) were evaluated to be 0.66, 9.82×10?5 cm2 s?1, respectively. And the electrochemical mechanism of L ‐tyrosine was also discussed.  相似文献   

12.
A new method for the determination of trace copper was described. A multiwalled carbon nanotube modified carbon paste electrode was prepared and the adsorptive voltammetric behavior of copper‐alizarin red S (ARS) complex at the modified electrode was investigated. By use of the second‐order derivative linear sweep voltammetry, it was found that in 0.04 mol/L acetate buffer solution (pH 4.2) containing 4×10?6 mol/L ARS, when accumulation potential is 0 mV, accumulation time is 60 s and scan rate is 100 mV/s, the complex can be adsorbed on the surface of the electrode, yielding one sensitive reduction peak at ?172 mV (vs. SCE). The peak current of the complex is proportional to the concentration of Cu(II) in the range of 2.0×10?11–4.0×10?7 mol L?1 with a detection limit (S/N=3) of 8.0×10?12 mol/L (4 min accumulation). The proposed method was successfully applied to the determination of copper in biological samples with satisfactory results, the recoveries were found to be 96%–102%.  相似文献   

13.
Abstract

A simple and sensitive capillary elecrophoretic method has been developed for the separation and determination of Nabam and NaDDC in boric acid buffer by direct UV absorbance detection at 254 nm. The separation is dependent on pH and nature of the buffer. In this method the detection limits (S/N = 3) are 1.56 × 10?6 mol/L and 2.48 × 10?6 mol/L and the linear calibration range is three orders of magnitude for Nabam and NaDDC, respectively. The method has been successfully applied for the analysis of wheat samples spiked with Nabam.  相似文献   

14.
Chuanyin Liu  Jiming Hu 《Electroanalysis》2008,20(10):1067-1072
Hemoglobin was entrapped in composite electrodeposited chitosan‐multiwall carbon nanotubes (MCNTs) film by assembling gold nanoparticles and hemoglobin step by step. In phosphate buffer solution (pH 7), a pair of well‐defined and quasireversible redox peaks appeared with formal potential at ?0.289 V and peak separation of 100 mV. The redox peaks respected for the direct electrochemistry of hemoglobin at the surface of chitosan‐MCNTs‐gold nanoparticles modified electrode. The parameters of experiments have also been optimized. The composite electrode showed excellent electrocatalysis to peroxide hydrogen and oxygen, the peak current was linearly proportional to H2O2 concentration in the range from 1×10?6 mol/L to 4.7×10?4 mol/L with a detection limit of 5.0×10?7 mol/L, and this biosensor exhibited high stability, good reproducibility and better selectivity. The biosensor showed a Michaelis–Menten kinetic response as H2O2 concentration is larger than 5.0×10?4 mol/L, the apparent Michaelis–Menten constant for hydrogen peroxide was calculated to be 1.61 μmol/L.  相似文献   

15.
采用毛细管电泳/安培检测法(CE/AD)同时分离测定了绿茶中的芦丁、没食子酸、槲皮素、绿原酸等生物活性成分的含量, 考察了运行缓冲液酸度、浓度、分离电压、氧化电位和进样时间等实验参数对分离、检测的影响。在最优化条件下, 以300 μm碳圆盘电极为检测电极, 检测电位为+ 950 mV (vs. SCE) , 60 mmol/L硼酸盐运行缓冲液(pH 8.7)中, 上述各组分在20 min内可实现基线分离。各组分浓度与峰电流在3个数量级范围内呈良好线性, 检出限(S/N=3)在1.0×10-7到1.0×10-4g.mL-1范围,四种标样7次平行进样的相对标准偏差(RSD)小于3.0 %。该方法已成功地应用于绿茶中生物活性成分的测定, 结果令人满意。  相似文献   

16.
Simultaneous determination of dihydroxybenzene isomers was investigated at a multi‐wall carbon nanotubes (MWCNTs)/β‐cyclodextrin composite modified carbon ionic liquid electrode in phosphate buffer solution (pH 7.0, 1/15 mol/L) in the presence of cationic surfactant cetylpyridinium bromide (CPB). With the great enhancement of surfactant CPB, the voltammetric responses of dihydroxybenzene isomers were more sensitive and selective. The oxidation peak potential of hydroquinone was about 0.024 V, catechol was about 0.140 V and resorcinol 0.520 V in differential pulse voltammetric (DPV) measurements, which indicated that the dihydroxybenzene isomers could be separated entirely. The electrode showed wide linear behaviors in the range of 1.2×10?7–2.2×10?3, 7.0×10?7–1.0×10?3, 2.6×10?6–9.0×10?4 mol/L for hydroquinone, catechol and resorcinol, respectively. And the detection limits of the three dihydroxybenzene isomers were 4.0×10?8, 8.0×10?8, 9.0×10?7 mol/L, respectively. The proposed method could be applied to the determination of dihydroxybenzene isomers in artificial wastewater, and the recovery was from 97.4% to 104.2%.  相似文献   

17.
A rapid, simple, and practical method for the determination of four of the most used thyreostatic drugs (methimazole, 2‐thiouracil, 6‐methyl‐2‐thiouracil, and 6‐propyl‐2‐thiouracil) using CE coupled to electrochemiluminescence detection has been established, based on the electrochemiluminescence enhancement of tris(2,2‐bipyridyl)ruthenium(II) with these analytes. Parameters that affect separation and detection were optimized. Under the optimum experimental conditions, the four analytes could be well separated within 11 min at the separation voltage of 16 kV in a running solution containing 20 mM phosphate buffer (pH 9.0) and 1.0 × 10?4 M Ru(bpy)32+, with a solution of 20 mM phosphate buffer (pH 12.0) containing 1.0 × 10?4 M Ru(bpy)32+ in the electrochemiluminescence detection cell. The detection limits for methimazole, 6‐methyl‐2‐thiouracil, 6‐propyl‐2‐thiouracil, and 2‐thiouracil were 0.1, 0.05, 0.05, and 0.01 μM, respectively. The proposed method was applied to analyze these drugs in spiked animal feed samples. The recoveries were 88.2~99.0 and 86.4~98.7% for the intraday and interday analyses, respectively. The RSDs were 2.7~4.8 and 1.8~5.0% for the intraday and interday analyses, respectively. The results demonstrate that the proposed method has promising applications in the detection of thyreostatic drugs in animal feeds.  相似文献   

18.
A continuous cyclic voltammetric study of letrozole at gold microelectrode was carried out. The drug in phosphate buffer (pH 2.0) is adsorbed at ?200 mV, giving rise to change in the current of well‐defined oxidation peak of gold in the flow injection system. The proposed detection method has some of advantages, the greatest of which are as follows: first, it is no more necessary to remove oxygen from the analyte solution and second, this is a very fast and appropriate technique for determination of the drug compound in a wide variety of chromatographic analysis methods. Signal‐to‐noise ratio has significantly increased by application of discrete Fast Fourier Transform (FFT) method, background subtraction and two‐dimensional integration of the electrode response over a selected potential range and time window. Also in this work some parameters such as sweep rate, eluent pH, and accumulation time and potential were optimized. The linear concentration range was of 1.0×10?7?1.0×10?10 mol/L (r=0.9975) with a limit of detection and quantitation 0.08 nmol/L and 0.15 nmol/L, respectively. The method has the requisite accuracy, sensitivity, precision and selectivity to assay letrozol in tablets. The influences of pH of eluent, accumulation potential, sweep rate, and accumulation time on the determination of the letrozol were considered.  相似文献   

19.
A method based on capillary electrophoresis with electrochemical detection has been developed for the separation and determination of epicatechin, isovanillic acid, vanillic acid and myricetin in Dioscorea bulbifera L. and its medicinal preparations. The effects of working electrode potential, pH and concentration of running buffer, separation voltage and injection time were investigated. Under optimum conditions, the analytes could be separated in a 40 mmol L?1 borate buffer (pH 8.7) within 15 min. A 300 μm diameter carbon disk electrode has a good response at + 0.95 V (vs. SCE) for all analytes. The response was linear over three orders of magnitude with detection limits (S/N = 3) ranging from 3.0 × 10?8 g mL?1 to 1.0 × 10?7 g mL?1. The method has been successfully applied to the analysis of real samples.  相似文献   

20.
A carbon fiber paste electrode using ionic liquid as the binder (CFILE) was fabricated. The electrochemical characteristics of the electrode was examined in ferro‐/ferricyanide solution and showed better conductivity and reversibility when compared with graphite paste‐ionic liquid electrode (GPILE) and a little better than that on the carbon nanotube paste‐ionic liquid electrode (CNTILE). Glyphosate (GLY), a pesticide, exhibited excellent catalysis to the oxidation of Ru(bpy)2+3 on CFILE and brought an obvious enhancement to the electrochemiluminescence (ECL) intensity of Ru(bpy)2+3. Based on the catalytic ability of GLY, a simple ECL method for GLY detection had been established. Under optimum conditions, the enhanced ECL intensities were found to had linearly respond to the GLY concentration between 3.0×10?7 and 3.0×10?5 mol/L, and the detection limit (S/N=3) was 2.0×10?7 mol/L. The electrode also showed excellent sensitivity in detecting GLY‐spiked soybean samples. The linear range for GLY in soybean samples was 1.0×10?6–4.0×10?5 mol/L and the detection limit was 5.0×10?7 mol/L, equal to 8.45 µg GLY in per gram of soybean. The detection limit in soybean sample was lower than the USA, EU regulation and so on. If the method is coupled with the separation technology, it can be applied to detect the GLY in the contaminated samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号