首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A fully disposable microanalytical device based on combination of poly(methylmethacrylate) (PMMA) capillary electrophoresis microchips and thick-film electrochemical detector strips is described. Variables influencing the separation efficiency and amperometric response, including separation voltage or detection potential are assessed and optimized. The versatility, simplicity and low-cost advantages of the new design are coupled to an attractive analytical performance, with good precision (relative standard deviation RSD = 1.68% for n = 10). Applicability for assays of mixtures of hydrazine, phenolic compounds, and catecholamines is demonstrated. Such coupling of low-cost PMMA-based microchips with thick-film electrochemical detectors holds great promise for mass production of single-use micrototal analytical systems.  相似文献   

2.
《Electroanalysis》2005,17(21):1991-1994
The development and performance of an end‐column amperometric detection system integrated with disposable screen‐printed electrodes for capillary electrophoresis is presented. In this system, the electrode and capillary can be easily replaced and the capillary/electrode alignment procedure is straightforward. The use of easily replaceable screen‐printed electrodes offers a tremendous benefit for capillary electrophoresis applications requiring frequent replacement of the working electrode due to fouling. This simple and convenient system is very attractive for routine analyses by capillary electrophoresis with electrochemical detection. The separation and determination of uric acid in human urine is presented.  相似文献   

3.
Natural iron concentrations in real water samples have been determined by thermal lensing as a high performance capillary electrophoresis detector. 1,10-Phenanthroline was used as a chromogenic reagent, which forms a stable complex with Fe(II) but not with Fe (III). The interferences by other cations can be neglected by a combination of this photometric technique with high performance capillary electrophoresis. Laser induced thermal lens spectroscopy is demonstrated as a new technique for the measurement of small absorbances in the picoliter detection volume of a capillary. A limit of detection of 36 nmol/L with a signal to noise ratio of 7?:?1 was achieved using a 75 μm fused silica capillary.  相似文献   

4.
毛细管电泳-荧光/非接触电导组合型检测器的研制   总被引:3,自引:0,他引:3  
杨丙成  谭峰  关亚风 《分析化学》2005,33(5):740-742
报道了一种毛细管电泳-荧光/非接触电导组合型检测器。该检测器共用非接触电导检测池,实现了双检测器响应同步。优化了非接触电导检测系统中激发电压信号及其频率;荧光检测是用发光二极管作为激发光源,用光纤收集并传输荧光信号至光电倍增管。用无机金属离子和异硫氰酸荧光素评价该体系,结果表明,该检测器达到了任一单类型检测器性能指标。  相似文献   

5.
Matysik FM 《Electrophoresis》2002,23(3):400-407
Over the recent years considerable efforts have been directed to the design of powerful detector arrangements for capillary electrophoresis (CE). The analytical characteristics of the detector have a great influence on the overall analytical performance of CE investigations. The major detection methods in CE, such as UV-Vis absorbance, fluorescence, mass spectrometry and electrochemical detection, have successfully been adapted also to nonaqueous capillary electrophoresis (NACE). However, the different properties of organic solvent systems require some modification of detector concepts and design compared to aqueous CE. The advances of detector development and application in NACE are reported and discussed with emphasis on methodical aspects.  相似文献   

6.
Z Zhou  K Wang  X Yang  S Huang  L Zhou  D Qin  L Du 《The Analyst》2001,126(11):1838-1840
A novel method for the synchronization of separation and determination is described, in which a mode-filtered light detector is used as an online detector in capillary electrophoresis. An instrument is described which has been developed for this purpose. The round capillary used in conventional capillary electrophoresis is replaced by an annular column, which is constructed from a naked optical fibre inserted into a fused-silica capillary. In fact, the annular electrophoresis column itself forms part of the mode-filtered light sensor. Along the side of the annular column are several detection channels for gathering and transmitting the mode-filtered light to a charge-coupled device (CCD). Every channel provides information on the sample from the point at which it is located. Using capillary isotachophoresis incorporating the annular column, the analytes in a sample containing alanine (10.0 mM) and glycine (9.7 mM) were simultaneously separated and determined using multichannel mode-filtered light detection with a detection limit of 1.5 mM.  相似文献   

7.
一种共聚焦激光诱导荧光检测器的研制   总被引:6,自引:0,他引:6  
杨丙成  关亚风  黄威东  车迅 《色谱》2002,20(4):332-334
 基于共聚焦检测,研制了一台便携式激光诱导荧光检测器。该系统具有体积小、重量轻、成本低等特点;成像观察校准系统使日常校准非常简单。采用毛细管电泳和流动注射方式对该体系性能进行了评价,以Cy5染料与Cy5标记的色氨酸作为检测物质,其检测下限为3.7 nmol/L。  相似文献   

8.
A new SU-8 based microchip capillary electrophoresis (MCE) device has been developed for the first time with integrated electrochemical detection. Embedded electrophoretic microchannels have been fabricated with a multilayer technology based on bonding and releasing steps of stacked SU-8 films. This technology has allowed the monolithic integration in the device of the electrochemical detection system based on platinum electrodes. The fabrication of the chips presented in this work is totally compatible with reel-to-reel techniques, which guarantee a low cost and high reliability production. The influence of relevant experimental variables, such as the separation voltage and detection potential, has been studied on the SU-8 microchip with an attractive analytical performance. Thus, the effective electrical isolation of the end-channel amperometric detector has been also demonstrated. The good performance of the SU-8 device has been proven for separation and detection of the neurotransmitters, dopamine (DA) and epinephrine (EP). High efficiency (30,000-80,000 N/m), excellent precision, good detection limit (450 nM) and resolution (0.90-1.30) has been achieved on the SU-8 microchip. These SU-8 devices have shown a better performance than commercial Topas (thermoplastic olefin polymer of amorphous structure) microchips. The low cost and versatile SU-8 microchip with integrated platinum film electrochemical detector holds great promise for high-volume production of disposable microfluidic analytical devices.  相似文献   

9.
Wang X  Li J  Qu W  Chen G 《Journal of chromatography. A》2011,1218(32):5542-5548
This report describes the development and application of a novel graphene/poly(methyl methacrylate) composite electrode as a sensitive amperometric detector of capillary electrophoresis. The composite electrode was fabricated on the basis of the in situ polymerization of a mixture of graphene and prepolymerized methyl methacrylate in the microchannel of a piece of fused silica capillary under heat. SEM, XRD and FT-IR offered insights into the nature of the composite. The results indicated that graphenes were well dispersed in the composite to form an interconnected conducting network. The performance of this unique graphene-based detector has been demonstrated by separating and detecting seven naturally occurring phenolic compounds in Herba Geranii in combination with capillary electrophoresis. The graphene-based detector offered significantly lower operating potentials, substantially enhanced signal-to-noise characteristics, and lower expense of operation. The simplicity and significant performance exhibited by the graphene/poly(methyl methacrylate) composite electrode also indicate great promise for microchip CE, flowing injection analysis, and other microfluidic analysis systems.  相似文献   

10.
发光二极管诱导荧光用于毛细管电泳检测   总被引:2,自引:2,他引:2  
杨丙成  谭峰  关亚风 《分析化学》2003,31(9):1066-1068
利用发光二极管作为激发光源,组装了用于毛细管电泳的荧光检测器。光纤用于传输荧光信号;光纤端面修饰成球形使耦合效率比平面端光纤提高了50.8%;光阑、光纤及毛细管检测池之间的光学校准简单、便捷。荧光素染料用于评价该体系性能,得到了fmol的质量检出限。  相似文献   

11.
A contactless conductivity detector integrated into a poly(dimethylsiloxane) microchip for electrophoresis is presented. It adopted the simplest configuration of electrodes commonly used in this detection mode for capillary electrophoresis microchips. Although the chip is based on a simple and effective design, it is able to obtain low detection levels due to the low noise of the detection circuit. A circuit based on a lock-in amplifier was designed on printed circuit boards to read out the signal. The property of the detection cell was studied by applying excitation signals of different frequencies and different amplitudes. It was found that the best detection limit could be achieved with a frequency of 50?kHz and amplitude of 20?V. The performance of the detector was demonstrated by successfully separating and detecting several inorganic ions and also a mixture of heavy metal ions. An average detection limit of 0.4?μM was obtained for inorganic cations. This value is significantly improved compared to similar microchip-based detectors. The presented detector could be promising for mass production due to its properties, such as simple construction, high degree of integration, high performance and low cost.  相似文献   

12.
谭峰  关亚风 《色谱》2005,23(2):152-157
介绍了电容耦合非接触电导检测(C4D)的检测原理及其最新的研究进展,引用文献50篇。C4D是近几年发展起来的一种用于毛细管电泳和微流控芯片电泳的新检测技术。C4D检测器的原理清楚,结构简单,易于微型化、集成化,不污染检测电极,因而很有应用价值。  相似文献   

13.
A new laser-induced fluorescence (LIF) detector for multicapillary electrophoresis is presented. The detection principle is based on waveguiding of the emitted fluorescence from the point of illumination to the capillary ends by total internal reflection (TIR) and imaging of the capillary ends. The capillaries themselves thus act as liquid core waveguides (LCWs). At the illumination point, the capillaries are arranged in a planar array, which allows clean and efficient illumination with a line-focused laser beam. The capillary ends are rearranged into a small, densely packed two-dimensional array, which is imaged end-on with high light collection efficiency and excellent image quality. Wavelength dispersion is obtained with a single prism. Intercapillary optical crosstalk is less than 0.5%, and rejection of stray light is very efficient. The detector is applied to four-color DNA sequencing by gel electrophoresis in a 91-capillary array, with simple fluorescein and rhodamine dyes as fluorophores. Since the imaged two-dimensional array is so compact, the detector has a high potential for very large-scale multiplexing.  相似文献   

14.
A method is described to enhance the resolution and detection sensitivity of proteins, peptides, and amino acids in capillary electrophoretic analysis of solution mixtures. The method consists of derivatizing the analytes with fluorescamine, which is normally used as a fluorogenic reagent for compounds containing a reactive primary amine functional group, and then using the derivative as an ultraviolet chromophore to enhance detection sensitivity (measured at 280 nm) in capillary electrophoresis. The results demonstrated a significant improvement in the separation and detection sensitivity of the derivatized analytes as compared to their underivatized counterparts. The use of chromophores, such as fluorescamine, in capillary electrophoresis facilitates the analysis of components of solution mixtures, such as pharmaceutical formulations, that could not be resolved and/or detected by conventional capillary electrophoresis procedures.  相似文献   

15.
杨冰仪  莫金垣  赖容 《化学学报》2003,61(9):1461-1465
报道了一种双工作电极-双通道毛细管电泳电化学检测系统,实现电导和安培 同时检测或者安培与安培检测联用,使两种方法相互补充,发挥各自的优势。其中 ,工作电极与检测池的制作工艺简单,操作简便,通过不锈钢针管和毛细管作为套 管,无需三维微调装置即可简单实现双工作电极的准确放置及分离毛细管与工作电 极的准确对接,并根据分析体系的需要采用不同类型的工作电极和检测器;同时采 用复式滤波电路解决了不同检测器之间的电场叠加对输出信号的干扰问题。采用该 装置可以同时检测复杂体系中的电活性和惰性物质,或同时测定只能氧化或只能还 原的物质,还可以对具有氧化还原性质的物质进行纯度的确证。将该装置应用于实 际样品的测定,节约了分析时间,提高了分析速度,扩大了检测范围,结果令人满 意。  相似文献   

16.
A new type of dual-electrode and multi-channel electrochemical detection technology for capillary electrophoresis is described in this paper.Two detectors(the amperometric detector and the conductometric detector) or two conductometric detectors are connected to the same capillary electrophoresis system.The whole system possesses the advantages of the two electrochemical detectors including sparing time,improving the analytical speed and expanding the sample range.The working electrode and detector cell are handled easily.The system was applied to sample detection with satisfactory results.  相似文献   

17.
以金微盘电极和离子液体修饰单壁碳纳米管糊微盘电极分别作为毛细管电泳电化学检测器,试验了两种电极对过氧化氢的响应情况,将金微盘电极与毛细管电泳联用,对过氧化氢进行了定性和定量检测.探讨了分离电压、缓冲溶液pH值和工作电位等条件对H2O2检测的影响.实验结果表明,峰电流与H2O2浓度在1.0×10-6~1.0×10-5mo...  相似文献   

18.
We report a feasibility study on using a microwave-induced helium plasma atomic emission detector (MIP-AED) as an on-line detector in capillary zone electrophoresis (CZE). To couple CZE to MIP-AED, we used an ion exchange membrane capillary to connect the separation capillary to the interfacing capillary. The outlet end of the interfacing capillary was placed directly in the discharge tube of the MIP-AED system. The electroosmotic flow generated in the separation capillary carried the analytes and the electrolyte buffer solution through the interfacing capillary into the MIP-AED discharge tube where the analytes were detected. The performance of the CZE/MIP-AED system was evaluated with trimethyltin chloride, dimethyltin dichloride, n-propanol, and 2-butanone. The preliminary results indicate that the MIP-AED can be used in CZE to provide element-specific detection for target analytes.  相似文献   

19.
报道了毛细管电泳多道电化学检测器的研制及其应用,安培检测器和电导检测器并联在同一毛细管电泳检测系统中,在同一缓冲体系,同一工作电极下对同一复杂的分析体系同时进行电导和安培检测;整个装置综合了电导检测和安培检测两种检测器的优点,性能优良,造价低廉,对实际样品的检测取得了令人满意的结果。  相似文献   

20.
A simple analytical system using disposable, open-tubular ion exchange clean-up precolumns coupled in-line to capillary electrophoresis for direct injection of biological samples is presented. The clean-up precolumns were prepared from fused silica capillaries by thermally initiated layer-by-layer polymerization of poly(butadiene-maleic acid) (PBMA) directly on the capillary wall. Typically, 6 cm long precolumns with 4-layers of PBMA were used for sample pretreatment. A robust and reproducible coupling between the precolumn (75 μm ID) and the analytical capillary (50 μm ID) was achieved using an inexpensive, commercially available low dead volume union. No extra dispersion of the analyte zones was observed. Proteins and other high molecular weight compounds from biological sample matrices were retained on the cation-exchanger sites of the precolumn, which eliminated their adsorption on analytical capillary walls and ensured stable electroosmotic flow and migration times of target analytes. Unretained small inorganic cations migrated freely into the analytical capillary for separation and detection. Applicability of the sample clean-up procedure was proved by determination of major inorganic cations in blood serum and plasma samples using capillary electrophoresis with contactless conductivity detection. Separations were performed in background electrolyte solution consisting of 15 mM L-arginine, 12.5 mM maleic acid, 3 mM 18-crown-6 at pH 5.5 and repeatabilities of migration times and peak areas were below 1.5% and 7.3%, respectively. Less than 1 μL of biological sample was required for injection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号