首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Electroanalysis》2003,15(4):263-269
Bilayers composed of polypyrrole: doped by perchlorate ions (PPy(ClO4) – anion exchanging inner layer) and by dodecyl sulfate ions (PPy(DS) – cation exchanging outer layer) are very effective charge trapping systems that are usually not observed for other bilayers comprised of polypyrrole. Chronopotentiometric experiments carried out for oxidation and reduction showed that the trapping effect in the inner layer resulted from different ion exchange properties of the component polymers, leading to a low permeability of the reduced outer layer towards anions. Estimated diffusion coefficients of Cl? anions in the oxidized and reduced PPy(DS) are in the range of 10?9 and lower than 10?10 cm2 s?1, respectively. The presence of the outer layer limiting the ion transfer was found to be beneficial to improve the signal resolution in amperometric mode of ion sensing within wide KCl concentration range, from 10?5 M up to 3 M. The influence of experimental conditions (film thickness, response time) on optimization of this novel kind of polymeric bilayer ion sensors was studied.  相似文献   

2.
A ditopic ion‐pair receptor ( 1 ), which has tunable cation‐ and anion‐binding sites, has been synthesized and characterized. Spectroscopic analyses provide support for the conclusion that receptor 1 binds fluoride and chloride anions strongly and forms stable 1:1 complexes ([ 1? F]? and [ 1? Cl]?) with appropriately chosen salts of these anions in acetonitrile. When the anion complexes of 1 were treated with alkali metal ions (Li+, Na+, K+, Cs+, as their perchlorate salts), ion‐dependent interactions were observed that were found to depend on both the choice of added cation and the initially complexed anion. In the case of [ 1? F]?, no appreciable interaction with the K+ ion was seen. On the other hand, when this complex was treated with Li+ or Na+ ions, decomplexation of the bound fluoride anion was observed. In contrast to what was seen with Li+, Na+, K+, treating [ 1?F ]? with Cs+ ions gave rise to a stable, host‐separated ion‐pair complex, [F ?1? Cs], which contains the Cs+ ion bound in the cup‐like portion of the calix[4]pyrrole. Different complexation behavior was seen in the case of the chloride complex, [ 1? Cl]?. Here, no appreciable interaction was observed with Na+ or K+. In contrast, treating with Li+ produces a tight ion‐pair complex, [ 1? Li ? Cl], in which the cation is bound to the crown moiety. In analogy to what was seen for [ 1? F]?, treatment of [ 1? Cl]? with Cs+ ions gives rise to a host‐separated ion‐pair complex, [Cl ?1? Cs], in which the cation is bound to the cup of the calix[4]pyrrole. As inferred from liposomal model membrane transport studies, system 1 can act as an effective carrier for several chloride anion salts of Group 1 cations, operating through both symport (chloride+cation co‐transport) and antiport (nitrate‐for‐chloride exchange) mechanisms. This transport behavior stands in contrast to what is seen for simple octamethylcalix[4]pyrrole, which acts as an effective carrier for cesium chloride but does not operates through a nitrate‐for‐chloride anion exchange mechanism.  相似文献   

3.
Fullerence C60‐cryptand 22 was prepared and successfully applied as the electric carrier in the PVC electrode membrane of a bifunctional ion‐selective electrode for cations, e.g., Ag+ ions as well as anions, e.g., I? ions. The bifunctional ion‐selective electrode based on C60‐cryptand 22 can be applied as a Silver (Ag+) ion selective electrode with an internal electrode solution of 10?3 M AgNO3 in water (pH = 6.3), or as an Iodide (I?) ion selective electrode with an acidic internal electrode solution of 10?4 M KI(aq) (pH = 2) in which the cryptand 22 is protonated, and the C60‐cryptand 22 is changed to C60‐Cryptand22–H+ and becomes an anionic electro‐carrier to absorb the I? ion. The Ag+ ion selective electrode based on C60‐cryptand 22 gave a linear response with a near‐Nernstian slope (59.5 mV decade?1) within the concentration range 10?1‐10?3 M Ag+(aq). The Ag+ ion electrode exhibited comparatively good selectivity for silver ions, over other transition‐metal ions, alkali and alkaline earth metal ions. The Ag+ ion selective electrode with good stability and reproducibility was successfully used for the titration of Ag+(aq) with Cl? ions. The Iodide (I?) Ion selective electrode based on protonated C60–cryptand22‐H+ also showed a linear response with a nearly Nernstian slope (58.5 mV decade?1) within 10?1 ‐ 10?3 M I? (aq) and exhibited good selectivity for I? ions and had small selectivity coefficients (10?2–10?3) for most of other anions, e.g., F? , OH?, CH3COO?, SO42?, CO32?, CrO42?, Cr2O72? and PO43? ions.  相似文献   

4.
A new ditopic ion‐pair receptor 1 was designed, synthesized, and characterized. Detailed binding studies served to confirm that this receptor binds fluoride and chloride ions (studied as their tetraalkylammonium salts) and forms stable 1:1 complexes in CDCl3. Treatment of the halide‐ion complexes of 1 with Group I and II metal ions (Li+, Na+, K+, Cs+, Mg2+, and Ca2+; studied as their perchlorate salts in CD3CN) revealed unique interactions that were found to depend on both the choice of the added cation and the precomplexed anion. In the case of the fluoride complex [ 1? F]? (preformed as the tetrabutylammonium (TBA+) complex), little evidence of interaction with the K+ ion was seen. In contrast, when this same complex (i.e., [ 1? F]? as the TBA+ salt) was treated with the Li+ or Na+ ions, complete decomplexation of the receptor‐bound fluoride ion was observed. In sharp contrast to what was seen with Li+, Na+, and K+, treating complex [ 1? F]? with the Cs+ ion gave rise to a stable, receptor‐bound ion‐pair complex [Cs ?1? F] that contains the Cs+ ion complexed within the cup‐like cavity of the calix[4]pyrrole, which in turn was stabilized in its cone conformation. Different complexation behavior was observed in the case of the chloride complex [ 1? Cl]?. In this case, no appreciable interaction was observed with Na+ or K+. In addition, treating [ 1? Cl]? with Li+ produces a tightly hydrated dimeric ion‐pair complex [ 1? LiCl(H2O)]2 in which two Li+ ions are bound to the crown moiety of the two receptors. In analogy to what was seen in the case of [ 1? F]?, exposure of [ 1? Cl]? to the Cs+ ion gives rise to an ion‐pair complex [Cs ?1? Cl] in which the cation is bound within the cup of the calix[4]pyrrole. Different complexation modes were also observed when the binding of the fluoride ion was studied by using the tetramethylammonium and tetraethylammonium salts.  相似文献   

5.
Desorption/ionization on silicon (DIOS) mass spectra of model ionic dyes methylene blue (MB+Cl?) and methyl orange (Na+MO?) were studied using p+ type‐derived porous silicon (PS) free layers. As‐prepared PS (PS‐H), the PS thermally oxidized at 300 °C (PS‐OX), PS with chemically grafted cation‐exchanging alkylsulfonic acid (PS‐SO3H) and anion‐exchanging propyl‐octadecyldimethylammonium chloride (PS‐ODMA+Cl?) groups was tested as ionization platforms. Two mechanisms of the methylene blue desorption/ionization were found: (1) the formation of [MB + H]+? ion due to the reduction/protonation of MB+, which is predominant for PS‐H and PS‐OX platforms and (2) direct thermal desorption of the MB+ cation, prevailing for PS‐SO3H. The fragmentation of the cation is significantly suppressed in the latter case. The samples of PS‐SO3H and PS‐ODMA+ Cl? efficiently adsorb the dyes of the opposite charge from their solutions via the ion‐exchange. Consequent DIOS MS studies allow to detect only low fragmented ions (MB+ and MO?, respectively), demonstrating the potential of the ion‐exchange adsorption combined with DIOS MS for the analysis of ionic organic compounds in solutions. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
This research concerns the analysis of the metal ion binding of benzo‐ and pyridine‐azacrown ether compounds of different structures and sizes by potentiometric method. The ligands are able to form 1 : 1 complexes with heavy metal ions (Cu+2, Pb+2, Cd+2, Ag+, Ni+2, Zn+2) in water of middle or high stability. To understand the selectivity in cation binding, different factors were considered.  相似文献   

7.
《Electroanalysis》2006,18(24):2441-2450
The polymerization of pyrrole in β‐naphthalene sulfonic acid (NSA) gave nanotubules, nanomicelles or nanosheets of polypyrrole (PPy) depending on the amount of NSA in the polymer and the temperature of the reaction. Scanning electron microscopy (SEM) measurements showed that the diameters of the nanostructured polypyrrole‐β‐naphthalene sulfonic acid (PPyNSA) composites were 150–3000 nm for the tubules, 100–150 nm for the micelles and 20 nm for the sheets. A red shift in the UV‐vis absorption spectra of PPy was observed for PPyNSA which indicates the involvement of bulky β‐naphthalene sulfonate ion in the polymerization process. The UV‐vis also showed the existence of polaron and bi‐polaron in the polymer which may be responsible for the improved solubility of PPyNSA compared to PPy. All the characteristic IR bands of polypyrrole were observed in the FTIR spectra of PPyNSA, with slight variation in the absolute values. However, the absence of N? H stretching at 3400 cm?1 and 1450 cm?1 usually associated with neutral polypyrrole confirms that the polymer is not in the aromatic state but in the excited polaron and bipolaron defect state. Electrochemical analysis of PPyNSA reveals two redox couples: a/a′ – partly oxidized polypyrrole‐naphthalene sulfonate radical cation/neutral polypyrrole naphthalene sulfonate; b/b′ – fully oxidized naphthalene sulfonate radical cation/partly reduced polypyrrole‐naphthalene sulfonate radical anion. The corresponding formal potentials measured at 5 mV/s, E°′(5 mV/s), are 181 mV and 291 mV, respectively. Amperometric phenol sensor constructed with PPyNSA on a glassy carbon electrode (GCE) gave a sensitivity of 3.1 mA M?1 and a dynamic linear range of 0.65–139.5 μM. The data for the determination of phenol on the GCE/PPyNSA electrode was consistent with the electrocatalytic Michaelis‐Menten model, giving an apparent Michaelis‐Menten constant (KM′) value of 160 μM.  相似文献   

8.
The redox mediator Meldola blue (MB) was entrapped into two polymers, poly‐1,2‐diaminobenzene (p‐DAB) and poly‐3,4‐ethylenedioxythiophene (p‐EDOT) by potential cycling and films were applied to NADH oxidation with subsequent glutamate detection using immobilized glutamate dehydrogenase. Both polymer films were tested for electrocatalysis of NADH using amperometry at Eapp=0.1 V vs. Ag/AgCl and similar response characteristics were obtained with sensitivity values of 6.1 nA μM?1, linear range up to 0.5 mM (R2=0.9972) and LOD of 50 μM. Subsequent amperometric determination of glutamate resulted in sensitivity 0.7 nA μM?1, linearity 0–100 μM and detection limit of 2 μM glutamate.  相似文献   

9.
《Electroanalysis》2005,17(18):1609-1615
Potentiometric Ag+ sensors were prepared by galvanostatic electropolymerization of 3,4‐ethylenedioxythiophene (EDOT) and pyrrole (Py) on glassy carbon electrodes by using sulfonated calixarenes as doping ions. Poly(3,4‐ethylenedioxythiophene) (PEDOT) and polypyrrole (PPy) doped with p‐sulfonic calix[4]arene (C4S), p‐sulfonic calix[6]arene (C6S) and p‐sulfonic calix[8]arene (C8S) were compared. PEDOT and PPy doped with poly(styrene sulfonate) (PSS) were also included for comparison. The analytical performance of the conducting polymer‐based Ag+ sensors was studied by potentiometric measurements. All conducting polymer and dopant combinations showed sensitivity and selectivity to Ag+ compared to several alkali, alkaline‐earth, and transition‐metal cations. The type of the conducting polymer used for the fabrication of the electrodes was found to have a more significant effect on the selectivity of the electrodes to Ag+ than the ring size of the sulfonated calixarenes used as dopants. Selected conducting polymer‐based sensors were studied by cyclic voltammetry (CV) and energy dispersive analysis of X‐rays (EDAX) measurements. Results from the EDAX measurements show that both PEDOT‐ and PPy‐based membranes accumulate silver.  相似文献   

10.
The synthesis of a series of m‐terphenyl‐substituted tetrafluorosilicates with different cations (Na+, K+, Rb+, Cs+, Ag+, Tl+) is described and the interactions between the anion and cation are investigated in the solid, solution, and gas states by using multinuclear NMR spectroscopy, X‐ray diffraction, and ion cyclotron resonance Fourier‐transform mass spectrometry (ICR‐FT‐MS). In solution, heteronuclear NMR spectroscopy parameters show only limited sensitivity to the nature of the cation, which furthermore can be affected by solvent effects. More pronounced effects are observed in the structural data obtained from X‐ray diffraction studies, which are in good agreement with experimental gas‐phase data from ESIMS. ESIMS also reveals the existence of dimeric species of the type [M(DmpSiF4)2]? (Dmp=2,6‐dimesitylphenyl), the stability of which was determined by normalized collision energy experiments.  相似文献   

11.
The electrochemical polymerization technique has been successfully applied to produce conducting polymer film of controlled ion exchange properties. Polypyrrole films were prepared by electro-oxidative polymerization with doping some alkylsulfonates or Nafion. The ion exchange characteristics across polypyrrole films were examined by means of a novel electrochemical technique, namely, the in situ electrochemical quartz crystal microbalance (EQCM) method. According to EQCM measurements, exchanging ion species was found to be successfully controlled by changing the hydrophilic–hydrophobic balance of the incorporated sulfonated-based dopants. The film's characteristics became anion- to cation-exchanging as the dopants became more hydrophobic in nature. The polypyrrole–Nafion(poly(perfluoroethylene sulfonate)) composite film became to be a complete cation exchanger.  相似文献   

12.
A series of novel, fluorene‐based conjugated copolymers, poly[(9,9‐bis{propenyl}‐9H‐fluorene)‐co‐(9,9‐dihexyl‐9H‐fluorene)] ( P1 ), poly[(9,9‐bis{carboxymethylsulfonyl‐propyl}fluorenyl‐2,7‐diyl)‐co‐(9,9‐dihexyl‐9H‐fluorene)] ( P2 ) and poly[(9,9‐dihexylfluorene)‐co‐alt‐(9,9‐bis‐(6‐azidohexyl)fluorene)] ( P3 ), are synthesized by Suzuki coupling reactions and their electrochemical properties, in the form of films, are investigated using cyclic voltammetry. The results reveal that the polymer films exhibit electrochromic properties with a pseudo‐reversible redox behavior; transparent in the neutral state and dark violet in the oxidized state. Among the three polymers, P2 possesses the shortest response time and the highest coloration efficiency value. These polymers emit blue light with a band gap value of around 2.9 eV and have high fluorescent quantum yields. Their metal ion sensory abilities are also investigated by titrating them with a number of different transition metal ions; all of these polymers exhibit a higher selectivity toward Fe3+ ions than the other ions tested with Stern–Volmer constants of 4.41 × 106M?1, 3.28 × 107M?1, 1.25 × 106M?1, and 6.56 × 106M?1 for P1 , P2 , water soluble version of P2 ( P2S ) and P3 , respectively. © 2012 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem, 2013  相似文献   

13.
A novel capillary with high sensitivity and selectivity for mercury ion detection based on modified nanosize silica has been designed and synthesized. The obtained modified capillary was applied to separate and determine mercury ion by capillary electrophoresis with a laser‐induced fluorescence detector. The optimal experimental conditions were determined by evaluating various controlling factors: running buffer hexamine‐HCl 15 mmol L?1, pH=5.2, separation voltage 30 kV and temperature 25 °C. The modified capillary exhibited excellent sensitivity and selectivity for Hg2+ over other coexisting metal ions (K+, Ag+, Ca2+, Mg2+, Ba2+, Ni2+, Cd2+, Pb2+ and Zn2+ increased to 10000 times of Hg2+, Cu2+ increased to 5000 times) in aqueous solution, and was successfully applied to the determination of Hg2+ in natural water samples and displayed satisfactory results.  相似文献   

14.
Two sets of indium oxide thin films (~150 nm) grown on quartz substrates using thermal evaporation technique were processed separately with 25‐keV Co? and N+ ions with several fluences ranging from 1.0 × 1015 to 1.0 × 1016 ions/cm2. The pristine and the ion implanted films were characterized by Rutherford backscattering spectroscopy (RBS), X‐ray diffraction (XRD), scanning electron microscopy (SEM), atomic force microscopy (AFM) and UV–Vis spectrometry. The RBS spectra reveal signature of only cobalt and nitrogen in accordance to their fluences confirming absence of any contamination arising due to ion implantation. An increase in the average crystallite size (from 13.7 to 15.3 nm) of Co? ions implanted films was confirmed by XRD. On the other hand, the films implanted with N+ ions showed a decrease in the average crystallite size from 20.1 to 13.7 nm. The XRD results were further verified by SEM micrographs. As seen in AFM images, the RMS surface roughness of the samples processed by both ion beams was found to decrease a bit (29.4 to 22.2 nm in Co? implanted samples and 24.2 to 23.3 nm in N+ implanted samples) with increasing fluence. The Tauc's plot deduced from UV–visible spectroscopy showed that the band gap decreases from 3.54 to 3.27 eV in Co? implanted films and increases from 3.38 to 3.58 eV for films implanted with N+ ions. The experimental results suggest that the modifications in structural and optical properties of indium oxide films can be controlled by optimizing the implantation conditions. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

15.
Monomers derived from 3,4‐ethylenedioxythiophene and phenylenes with branched or oligomeric ether dialkoxy substituents were prepared with the Negishi coupling technique. Electrooxidative polymerization led to the corresponding dialkoxy‐substituted 3,4‐ethylenedioxythiophene–phenylene polymers, with extremely low oxidation potentials (E1/2,p = ?0.16 to ?0.50 V vs Ag/Ag+) due to the highly electron‐rich nature of these materials. The polymers were electrochromic, reversibly switching from red to blue upon oxidation, with bandgaps at about 2 eV. The electrochemical behavior of the oligomeric ether‐substituted polymer was investigated in the presence of different metal ions. Films of the polymer exhibited electrochemical recognition for several alkali and alkaline‐earth cations with selectivity in the order Li+ > Ba2+ > Na+ > Mg2+. Cyclic voltammetry showed a decrease in the oxidation potential and an improvement in the definition of the voltammetric response, as well as an increase in the overall electroactivity of the polymer films when the concentration of the cations in the medium was increased. These results are discussed in terms of the electrostatic interactions between the complexed cation and the redox center, as well as the diffusion of the ionic species into the polymer matrix. © 2001 John Wiley & Sons, Inc. J Polym Sci Part A: Polym Chem 39: 2164–2178, 2001  相似文献   

16.
《Electroanalysis》2006,18(10):1019-1027
A new PVC membrane potentiometric sensor for Ag(I) ion based on a recently synthesized calix[4]arene compound of 5,11,17,23‐tetra‐tert‐butyl‐25,27‐dihydroxy‐calix[4]arene‐thiacrown‐4 is developed. The electrode exhibits a Nernstian response for Ag(I) ions over a wide concentration range (1.0×10?2?1.0×10?6 M) with a slope of 53.8±1.6 mV per decade. It has a relatively fast response time (5–10 s) and can be used for at least 2 months without any considerable divergence in potentials. The proposed electrode shows high selectivity towards Ag+ ions over Pb2+, Cd2+, Co2+, Zn2+, Cu2+, Ni2+, Sr2+, Mg2+, Ca2+, Li+, K+, Na+, NH4+ ions and can be used in a pH range of 2–6. Only interference of Hg2+ is found. It is successfully used as an indicator electrode in potentiometric titration of a mixture of chloride, bromide and iodide ions.  相似文献   

17.
An amperometric cholesterol biosensor based on immobilization of cholesterol oxidase in a Prussian blue (PB)/polypyrrole (PPy) composite film on the surface of a glassy carbon electrode was fabricated. Hydrogen peroxide produced by the enzymatic reaction was catalytically reduced on the PB film electrode at 0 V with a sensitivity of 39 μA (mol/L)?1. Cholesterol in the concentration range of 10?5 ? 10?4 mol/L was determined with a detection limit of 6 × 10?7 mol/L by amperometric method. Normal coexisting compounds in the bio‐samples such as ascorbic acid and uric acid do not interfere with the determination. The excellent properties of the sensor in sensitivity and selectivity are attributed to the PB/PPy layer modified on the sensor.  相似文献   

18.
This paper reports the development and characterization of a solid state potentiometric sensor for chloride ions, based on doped polypyrrole‐graphite‐epoxy composite. The optimum mixture proportion found for polypyrrole:graphite was 60 : 40 meanwhile a 50 : 50 proportion was used for the polypyrrol+graphite:epoxy mixture. The stabilization time was approximately 16 min, while the response times varied within 2 and 23 s. The sensor displayed a sensitivity of 58 mV/decade [Cl?], and 3×10?6 M detection limit. The selectivity coefficients showed a greater selectivity to that reported for commercial‐type sensors. The statistical analysis for chlorides' determination in commercial saline serums did not show significant differences respect to data reported by the manufacturers.  相似文献   

19.
Helical structures are interesting due to their inherent chirality. Helicenium ions are triarylmethylium structures twisted into configurationally stable helicenes through the introduction of two heteroatom bridges between the three aryl substituents. Of the configurationally stable [4]helicenium ions, derivatives with sulfur, oxygen and nitrogen bridges have already been synthesised. However, one [4]helicenium ion has proven elusive, until now. We present herein the first synthesis of the 1,13‐dimethoxychromeno[2,3,4‐kl]acridinium (DMCA+) [4]helicenium ion. A series of six differently N‐substituted DMCA+ ions as their hexafluorophosphate salts are reported. Their cation stability was evaluated and it was found that DMCA+ is ideally suited as a phase‐transfer catalyst with a pKR+ of 13.0. The selectivity of nucleophilic addition to the central carbon atom of DMCA+ has been demonstrated with diastereotopic ratios of up to 1:10. The single‐crystal structures of several of the DMCA+ salts were determined, and structural differences between N‐aryl‐ and N‐alkyl‐substituted cations were observed. The results of a comparative study of the photophysics of the [4]helicenium ions are presented. DMCA+ is found to be a potent red‐emitting dye with a fluorescence quantum yield of 20 % in apolar solvents and a fluorescence lifetime of 12 ns. [4]Helicenium ions, including DMCA+, all suffer from solvent‐induced quenching, which reduces the fluorescence quantum yields significantly (?fl<5 %) in polar solvents. A difference in photophysical properties is observed between N‐aryl‐ and N‐alkyl‐substituted DMCA+, which has tentatively been attributed to a difference in molecular conformation.  相似文献   

20.
Aromatic ketones are enantioseletively hydrogenated in alcohols containing [RuX{(S,S)‐Tsdpen}(η6p‐cymene)] (Tsdpen=TsNCH(C6H5)CH(C6H5)NH2; X=TfO, Cl) as precatalysts. The corresponding Ru hydride (X=H) acts as a reducing species. The solution structures and complete spectral assignment of these complexes have been determined using 2D NMR (1H‐1H DQF‐COSY, 1H‐13C HMQC, 1H‐15N HSQC, and 1H‐19F HOESY). Depending on the nature of the solvents and conditions, the precatalysts exist as a covalently bound complex, tight ion pair of [Ru+(Tsdpen)(cymene)] and X?, solvent‐separated ion pair, or discrete free ions. Solvent effects on the NH2 chemical shifts of the Ru complexes and the hydrodynamic radius and volume of the Ru+ and TfO? ions elucidate the process of precatalyst activation for hydrogenation. Most notably, the Ru triflate possessing a high ionizability, substantiated by cyclic voltammetry, exists in alcoholic solvents largely as a solvent‐separated ion pair and/or free ions. Accordingly, its diffusion‐derived data in CD3OD reflect the independent motion of [Ru+(Tsdpen)(cymene)] and TfO?. In CDCl3, the complex largely retains the covalent structure showing similar diffusion data for the cation and anion. The Ru triflate and chloride show similar but distinct solution behavior in various solvents. Conductivity measurements and catalytic behavior demonstrate that both complexes ionize in CH3OH to generate a common [Ru+(Tsdpen)(cymene)] and X?, although the extent is significantly greater for X=TfO?. The activation of [RuX(Tsdpen)(cymene)] during catalytic hydrogenation in alcoholic solvent occurs by simple ionization to generate [Ru+(Tsdpen)(cymene)]. The catalytic activity is thus significantly influenced by the reaction conditions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号