首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《Electroanalysis》2004,16(9):741-747
This work reports a technique for the rapid electrochemical detection of propranolol and metoprolol in pharmaceutical preparations using stabilized lipid films. Microporous filters composed of glass fibers (nominal pore sizes 0.7 and 1.0 μm) were used as supports for the formation and stabilization of these devices. The lipid film is formed on the filter by polymerization prior to its use. This stabilized after storage in air. Lipid films composed of phosphatidylcholine were used for the detection of propranolol and metoprolol in pharmaceutical preparations. The stabilized lipid membranes provided artificial ion gating events in the form of transient signals within about 60 and 34 s after exposure of the membranes to propranolol and metoprolol, respectively. The magnitude of the transient current signal was related to the concentration of propranolol and metoprolol in bulk solution in the micromolar range. The mechanism of signal generation was investigated by differential scanning calorimetric studies. These studies revealed that the adsorption of the drug is through the hydrophobic aryl terminal of the compound, whereas the hydrophilic groups were directed towards the electrolyte solution. This adsorption caused a rapid alteration of the electrochemical double layer of the lipid film (i.e., capacitance changes) that resulted in the transient ion current signal. The present technique was used for the rapid detection of propranolol and metoprolol in pharmaceutical preparations and can function for repetitive uses after storage in air. Future research is targeted to the determination of these chemicals in human biofluids such as urine of athletes.  相似文献   

2.
This work describes the preparation of a selective receptor for the rapid, selective and sensitive electrochemical flow injection analysis of carbofuran in foods using air stable lipid films supported on a methacrylate polymer on a glass fiber filter with incorporated artificial receptor. The selective receptor was synthesized by transformation of the ? OH groups of resorcin[4]arene receptor into phosphoryl groups. These lipid films were supported on a methylacrylate polymer (i.e., methacrylic acid was the functional monomer for the polymerization, ethylene glycol dimethacrylate was used as the crosslinker and 2,2′‐azobis‐2‐methylpropionitrile as an initiator). A minisensor device was constructed for the electrochemical flow injection analysis of toxicants based on air stabilized lipid films supported on a polymer. The device can sense the analyte in a drop (50 μL) of sample. Carbofuran was injected into flowing streams of a carrier electrolyte solution. A host‐guest complex formation between the calix[4]arene phosphoryl receptor and carbofuran takes place through hydrogen bonding. This enhances the preconcentration of carbofuran at the lipid membrane surface which in turn causes dynamic alterations of the electrostatic fields and phase structure of membranes; as a result ion current transients were obtained and the magnitude of these signals was correlated to the substrate concentration. The response times were ca. 80 s and carbofuran was determined at concentration levels of nM. The effect of potent interferences included a wide range of compounds and other insecticides. The effect of interference of proteins and lipids was also examined. The reproducibility of the method was checked by recovery experiments in fruit and vegetable samples with satisfactory results.  相似文献   

3.
The present work describes a miniaturized potentiometric cholera toxin sensor on graphene nanosheets with incorporated lipid films. Ganglioside GM1, the natural cholera toxin receptor, immobilized on the stabilized lipid films, provided adequate selectivity for detection over a wide range of toxin concentrations, fast response time of ca. 5 min, and detection limit of 1 nM. The proposed sensor is easy to construct and exhibits good reproducibility, reusability, selectivity, long shelf life and high sensitivity of ca. 60 mV/decade of toxin concentration. The method was implemented and validated in lake water samples. This novel ultrathin film technology is currently adapted to the rapid detection of other toxins that could be used in bioterrorism.  相似文献   

4.
《Electroanalysis》2017,29(4):990-997
A miniaturized potentiometric saxitoxin sensor on graphene nanosheets with incorporated lipid films and Anti‐STX, the natural saxitoxin receptor, immobilized on the stabilized lipid films is described in the present paper. An adequate selectivity for detection over a wide range of toxin concentrations, fast response time of ca. 5–20 min, and detection limit of 1 nM have been achieved. The proposed sensor is easy to construct and exhibits good reproducibility, reusability, selectivity, long shelf life and high sensitivity of ca. 60 mV/decade of toxin concentration. The method was implemented and evaluated in lake water and shellfish samples. This novel ultrathin film technology is currently adapted to the rapid detection of other toxins that could be used in bioterrorism.  相似文献   

5.
《Electroanalysis》2005,17(10):887-894
This work describes a technique for the rapid, selective and sensitive electrochemical flow injection analysis of mixtures of the stimulating compounds adrenaline, dopamine, and ephedrine using stabilized after storage in air bilayer lipid membranes (BLMs) with incorporated resorcin[4]arene receptor. Injections of the stimulating compounds were made into flowing streams of a carrier electrolyte solution and a transient current signal, with duration of seconds, reproducibly appeared in less than two min after exposure of the lipid membranes to the compounds. The magnitude of this signal was linearly related to the concentration of the compound, which could be determined at micromolar levels. Repetitive cycles of injection of stimulating compounds have shown no signal degradation during each cycle (30 sequential injections). The time of appearance of the transient response was different for each stimulating compound and increased in the order of adrenaline, dopamine and ephedrine. The difference in time of response has allowed selective detection and analysis of these compounds in mixtures. The investigation of the effect of potent interferences included a wide range of compounds usually found in human biofluids, as well as proteins and lipids. The results showed that only proteins (most common in lipid film based biosensors) pose a problem that can be eliminated by modulation of the carrier solution to flow rates that do not allow adsorption of these compounds in the lipid films. The technique was applied in human urine samples.  相似文献   

6.
《Electroanalysis》2003,15(20):1616-1624
This work uses lipid film based biosensors with incorporated calix[4]resorcinarene receptor (lipophilic macrocyclic host molecule) for the rapid electrochemical detection of adrenaline. Freely‐suspended and metal supported BLMs (composed of egg phosphatidylcholine (PC) and 35% (w/w) dipalmitoyl phosphatidic acid) modified with the resorcin[4]arene receptor were used as one shot sensors to rapidly detect this catecholamine. The interactions of this compound with freely‐suspended BLMs were found to be electrochemically transduced in the form of a transient current signal with duration of seconds, which reproducibly appeared about 14 s after exposure of the membranes to adrenaline. The response time for these BLMs without incorporated receptor for adrenaline was about 1.5 min. The magnitude of the transient current signal was related to the concentration of adrenaline in bulk solution in the micromolar range. Differential scanning calorimetric (DSC) experiments were performed to explore the mechanism of interactions of BLMs with incorporated receptor with adrenaline. The interactions of adrenaline with surface‐stabilized bilayer lipid membranes (sBLMs) with incorporated receptor produced electrochemical ion current increases, which reproducibly appeared within a few seconds after exposure of the membranes to the stimulant. The use of the receptor in sBLMs increased the sensitivity of the method 6‐fold. The current signal increases were related to the concentration of adrenaline in bulk solution in the micromolar range. Stabilized lipid membranes formed by polymerization on glass fiber microfilters were used as practical chemical biosensors for the rapid detection of adrenaline. The interactions of polymerized lipid films with adrenaline were also found to provide transient current signals similar to those of freely‐suspended BLMs. The magnitude of the transient current signal was also related to the concentration of the stimulating agent in bulk solution in the micromolar range and these stabilized lipid films can be used again after storage in air. No interferences from ascorbic acid were noticed because of the negatively charged lipids in membranes. The effect of other compounds such as proteins and other compounds closely related to adrenaline was also investigated. Results of recovery experiments using human urine have shown recoveries ranged between 94 to 105%, which shows no interferences from matrix effects due to the presence of urine constituents. The present sensor based on stabilized lipid films can be used for the rapid repetitive detection of this pharmaceutical substance and keep prospects for the selective determination of catecholamines in biofluids.  相似文献   

7.
The present article describes a miniaturized potentiometric carbofuran chemical sensor on graphene nanosheets with incorporated lipid films. The graphene electrode was used for the development of a very selective and sensitive chemical sensor for the detection of carbofuran by immobilizing an artificial selective receptor on stabilized lipid films. The artificial receptor was synthesized by transformation of the hydroxyl groups of resorcin[4]arene receptor into phosphoryl groups. This chemical sensor responded for the wide range of carbofuran concentrations with fast response time of ca. 20 s. The presented potentiometric carbofuran chemical sensor is easy to construct and exhibits good reproducibility, reusability, selectivity, rapid response times, long shelf life and high sensitivity of ca. 59 mV/decade over the carbofuran logarithmic concentration range from 10?6 to 10?3 M.  相似文献   

8.
A novel potentiometric uric acid biosensor was fabricated by immobilization of uricase into stabilized lipid films using zinc oxide (ZnO) nanowires as measuring electrode. Uricase was incorporated into the lipid film prior polymerization on the surface of well aligned ZnO nanowires resulting in a sensitive, selective, stable and reproducible uric acid biosensor. The potentiometric response was twice as large from previously reported values due to the presence of a cationic lipid in the lipid film. The sensor response had no interferences by normal concentrations of ascorbic acid, glucose, urea, proteins and lipids.  相似文献   

9.
The present work describes a miniaturized potentiometric naphthalene acetic acid (NAA) sensor on graphene nanosheets with incorporated lipid films. Auxin‐binding protein 1 receptor immobilized on the stabilized lipid films provided adequate selectivity for detection over a wide range of hormone concentrations, fast response time of ca. 5 min, and detection limit of 10 nM. The proposed sensor is easy to construct and exhibits good reproducibility, reusability, selectivity, long shelf life and high sensitivity of ca. 56 mV/decade of hormone concentration. The reliability of the biosensor was successfully evaluated using a wide range of NAA‐spiked fruits and vegetables.  相似文献   

10.
《Electroanalysis》2002,14(23):1661-1667
This work reports a technique for the rapid detection of vanillin in alcoholic beverages using stabilized lipid membrane based biosensors. Microporous filters composed of glass fibers (nominal pore sizes 0.7 and 1.0 μm) were used as supports for the polymerization of the lipid film and stabilization of these devices. The lipid film is formed on the filter by polymerization prior its use. Methacrylic acid was the functional monomer, ethylene glycol dimethacrylate was the crosslinker and 2,2′‐azobis‐(2‐methylpropionitrile) was the initiator. The response towards vanillin of the present stabilized lipid membrane biosensors composed of phosphatidylcholine was investigated. The stabilized lipid membranes provided artificial ion gating events in the form of transient signals and can be used again after storage in air. This has allowed the practical use of the technique for chemical sensing based on lipid film for the rapid detection of vanillin in wines and alcoholic beverages.  相似文献   

11.
A highly sensitive electrochemical sensor based on arenediazonium tosylates was designed to detect meldonium in urine. The effect of the concentration of ArN2+OTs arenediazonium tosylate modifier and various substituents was studied. Basic operating parameters for voltammetric meldonium detection were established and the procedure for urine sample preparation was developed. The following values were obtained: limit of detection (LOD) 0.005 mg ⋅ L−1 (P=0.95) and limit of quantification (LOQ) 0.01 mg ⋅ L−1. The relationship between the analytical signal and meldonium concentration in the solution ranging from 0.01 to 400 mg ⋅ L−1 was described by a linear function. The meldonium concentration error did not exceed 18 %. The analysis time for a single urine sample was reduced to 15 minutes.  相似文献   

12.
13.
采用扫集胶束毛细管电泳,建立了快速测定尿液中麻黄碱和可待因含量的方法,并通过日内、日间实验对方法的稳定性进行考察。讨论了pH值、十二烷基硫酸钠(SDS)浓度、分离电压、进样时间等因素的影响。建立了扫集胶束电动色谱的最佳实验条件,其中pH 2.2缓冲体系含80 mmol/L SDS,20 mmol/LNaH2PO4,18%(体积分数)乙腈,分离电压-20 kV,测量波长200 nm。在优化条件下,麻黄碱和可待因均在7 min内出峰,方法检出限(mg/L)、线性范围(mg/L)、相关系数分别为麻黄碱0.173、0.693-11.1、0.9993,可待因0.333、1.33-16.0、0.9993,应用于实际样品测定,回收率为94%-108%,RSD不大于3.5%。峰面积日内RSD不大于6.3%(n=5),日间RSD不大于9.3%(n=5)。  相似文献   

14.
The present article describes a miniaturized potentiometric D‐dimer biosensor on graphene nanosheets with incorporated lipid films. The graphene electrode was used for the development of a very selective and sensitive immunosensor for the detection of D‐dimer by immobilizing the mouse anti human D‐dimer antibody on stabilized lipid films. The immunosensor responded for the wide range of D‐dimer concentrations with fast response time of ca. 15 s. The presented potentiometric D‐dimer biosensor is easy to construct and exhibits good reproducibility, reusability, selectivity, rapid response times, long shelf life and high sensitivity of ca. 59 mV/decade over the D‐dimer logarithmic concentration range from 10?6 μg/L to 10?3 μg/L.  相似文献   

15.
建立了新型聚偏氟乙烯微孔滤膜-聚多巴胺-氧化石墨烯固相萃取结合便携式高分辨离子迁移谱对尿液中的麻黄碱进行快速检测的方法。通过对新型固相萃取膜的制备过程、吸附、洗脱过程进行优化,可对尿液中麻黄碱实现5 min吸附、10 min洗脱、30 ms进样的快速检测。结果显示,麻黄碱在0.124~6.129μg/mL质量浓度范围内的线性良好,检出限为9.60 ng/mL,方法的回收率为91.0%~113%。该方法能够快速地完成对尿液中麻黄碱的检测,为药驾在线检测和现场监察提供了有效手段。  相似文献   

16.
A simple,rapid and low-cost method of separation and determination of homovanillic acid and vanillylmandelic acid in human urine was developed based on capillary zone electrophoresis/amperometric detection with high sensitivity and good resolution.  相似文献   

17.
Wang  Shuping  Li  Xinchun  Yang  Jianping  Yang  Xiujuan  Hou  Fenghua  Chen  Zuanguang 《Chromatographia》2012,75(21):1287-1293

In clinical medicine, urine creatinine concentration is an important marker in the evaluation of renal function and muscular dysfunctions. Herein, we reported a novel method for rapid determination of creatinine in urine by microchip electrophoresis with light-emitting diode induced fluorescence detection. Creatinine was derivatized by fluorescein isothiocyanate, and then quantitatively detected by the developed microchip LED induced fluorescence detection system. The excitation and emission wavelengths were 490 and 523 nm, respectively. The urine samples were analyzed after centrifuge and filtration. A baseline separation was obtained in <30 s using 10 mM borate buffer (pH 9.0, containing 45 mM sodium dodecylsulfate), with separation voltage of 1.5 kV. Good linearity was obtained (r 2 = 0.9978) in the concentration range of 10.0–2.00 × 10μM, and the limit of detection was 2.87 μM (S/N = 3). The recovery was 96.0–107 %, and the interday precision was <4.5 % (n = 6). To validate assay results, we compared the present method with the Jaffe’s colorimetric assay by measuring real urine samples. The method was reliable, sensitive, high-speed, low-cost and suitable for the routine analysis of creatinine in biofluids.

  相似文献   

18.
Non-muscle Invasive Bladder Cancer (NMIBC) accounts for 80% of all bladder cancers. Although it is mostly low-grade tumors, its high recurrence rate necessitates three-times-monthly follow-ups and cystoscopy examinations to detect and prevent its progression. A rapid liquid biopsy-based assay is needed to improve detection and reduce complications from invasive cystoscopy. Here, we present a rapid spectroscopic method to detect the recurrence of NMIBC in urine. Urine samples from previously-diagnosed NMIBC patients (n = 62) were collected during their follow-up visits before cystoscopy examination. Cystoscopy results were recorded (41 cancer-free and 21 recurrence) and attenuated total refraction Fourier transform infrared (ATR-FTIR) spectra were acquired from urine samples using direct application. Spectral processing and normalization were optimized using parameter grid searching. We assessed their technical variability through multivariate analysis and principal component analysis (PCA). We assessed 35 machine learning models on a training set (70%), and the performance was evaluated on a held-out test set (30%). A Regularized Random Forests (RRF) model achieved a 0.92 area under the receiver operating characteristic (AUROC) with 86% sensitivity and 77% specificity. In conclusion, our spectroscopic liquid biopsy approach provides a promising technique for the early identification of NMIBC with a less invasive examination.  相似文献   

19.
王文雷  金文睿 《色谱》2007,25(6):799-803
采用微流控装置结合电化学检测研究了测定人单个血红细胞中谷胱甘肽(GSH)的方法。在该方法中,细胞的进样、定位、溶膜以及细胞中谷胱甘肽的转移和检测都在配有通道端安培检测器的双T形芯片中完成。单个细胞用液压导入到双T的交界面,在电泳缓冲液中毛地黄皂苷的作用下,细胞膜被穿孔。再施加直流电压,细胞被溶膜。释放出来的GSH被此直流电压电迁移至通道端并在Au/Hg电极上被检测。用校正曲线法可以定量测定单个细胞中的GSH。  相似文献   

20.
Chiral cholesteric molecular tweezer 7a was synthesized, and its recognition properties for Ag+, Al3+, Ca2+ etc., were investigated by UV and fluorescence spectra. The results showed that in ethanol/Tris (1/1, v/v, pH 7.0) buffer solution, the host molecular tweezer 7a had a specific recognition ability for Ag+, the detection limit was up to 1 × 10−6 mol/L, and other metal ions had little effect on Ag+ recognition. At the same time, the naked-eye detection of Ag+ was realized by the light red color of the complex solution. Furthermore, the mechanism of recognition of Ag+ by molecular tweezer 7a was studied by a nuclear magnetic titration test and computer molecular simulation, and a rapid detection method of Ag+ using host molecular tweezer 7a was established. Through the determination of Ag+ in milk powder, quinoa and other food samples, it was proved that this novel method had a good application prospect for the detection of Ag+ in food.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号