首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A fondamental difficulty in the experimental study of gravity-driven flows using particle image velocimetry (PIV) and other optical diagnostic techniques is the problem associated with variations in thé refractive index within the fluid. This paper discusses a method by which the refractive indices of two fluids are matched while maintaining density differences of up to 4%. Aqueous solutions of glycerol and potassium phosphate are used to achieve precise index matching in the presence of mixed and unmixed constituents. The effectiveness of the method is verified in a PIV study of a laboratory-scale model of an atmospheric microburst where planes of two-dimensional velocity vectors are obtained in thé evolving flow field.This work was sponsored by the National Science Foundation under grant CTS-9209948. We also thank TSI, Inc. for the use of its facility  相似文献   

2.
The measurement of dilution in jets and plumes by planar laser-induced fluorescence in large-scale stratified environments with refractive index matching is discussed. The density and refractive index of various salt (NaCl) and ethanol solutions were measured to high precision, and it is shown that linear stratifications with density differences at least up to 20 σ t with acceptably small refractive index variations can be achieved at reasonable cost. Equations are presented to facilitate the design of experiments with arbitrary density differences. The presence of ethanol significantly increases the laser attenuation, however. The rate of attenuation was measured for various solute concentrations and equations presented to predict the attenuation for arbitrary salt and ethanol concentrations. The rapid attenuation due to ethanol may limit the maximum density differences attainable with long laser traverse distances. Examples are given of discharges into linearly stratified fluids including a jet in a stationary environment, and a buoyant jet in a cross flow. Received: 9 April 1999/Accepted: 8 November 2000  相似文献   

3.
It is shown that an equation can be used to determine the exact quantities of components to yield a specified refractive index for an immersion fluid. The results obtained from this equation are compared with values obtained experimentally for two different immersion fluids, IMF 163 and Hallowax. The paper also discusses the kinds of errors that are introduced when a mismatch in refractive index occurs between model material and immersion fluid. Graphs are presented which show the effect of temperature on the refractive index, the degree of refraction of the light beam when the refractive indices are different between immersion fluid and birefringent model, and effect of the angle of incidence.  相似文献   

4.
Application of optical techniques such as PIV, PTV, and LDA for velocity field estimation in porous media requires matching of refractive indices of the liquid phase to that of the solid matrix, including the channel walls. The methods most commonly employed to match the refractive indices have been to maximize the transmitted intensity through the bed or to rely on direct refractometer measurements of the indices of the two phases. Mismatch of refractive indices leads to error in estimation of particle position, ε PD, due to refraction at solid–liquid interfaces. Analytical ray tracing applied to a model of solid beads placed randomly along the optical path is used to estimate ε PD. The model, after validating against experimental results, is used to generate expression for ε PD as a function of refractive index mismatch for a range of bead diameters, bed widths, bed porosity, and optical magnification. The estimate of ε PD, which is found to be unbiased, is connected to errors in PIV measurement using the central limit theorem. Mismatch in refractive indices can also lead to reduction in particle density, N s, detected light flux, J, and degrade the particle image. The model, verified through experiments, is used to predict the reduction in N s and J, where it is found that particle defocusing caused by spherical beads in refractive index mismatched porous bed is the primary contributor to reductions of N s and J. In addition, the magnitude of ε PD is determined for the use of fluorescent dye emission for particle detection due to wavelength-dependent index of refraction.  相似文献   

5.
Detailed measurements of the coolant flow field have been made in the water passages of the cylinder head of an internal combustion engine. They were obtained by casting a transparent acrylic model of the cylinder head and using a mixture of hydrocarbon fluids at a predetermined temperature and concentration which ensured that the refractive index of the fluid was identical to that of the acrylic. This arrangement allowed the use of laser Doppler velocimetry to measure local velocities throughout the cooling passages. The results show that the flow was unevenly distributed with around three quarters of the total passing through the exhaust-portside passages and larger coolant velocities close to the top of the head than close to the gas face. The results of this study aimed to assist the improvement of the specific cylinder head design.  相似文献   

6.
Conventional methods for determining the refractive index demand specimens of optical quality, the preparation of which is often very difficult. An indirect determination by matching the refractive indices of specimen and immersion liquid is a practical alternative for photoelastic specimen of nonoptical quality. An experimental arrangement used for this technique and observations made while matching the refractive indices of three different specimens are presented.  相似文献   

7.
We report a combined experimental and theoretical investigation of the influence of spatial non-uniformities of the refractive index on the accuracy of laser Doppler anemometry (LDA) measurements in transparent fluids. One LDA beam is guided through heated air of a thermal boundary layer near a heated vertical flat plate. It is found that the hot air is deflecting the beam because of a modification of the refractive index n in the fluid. This deflection causes three effects: (1) spatial displacement of beam intersection, (2) waist mismatch in the measurement volume and (3) variation in interference fringe distance. With the help of a rotating disk calibration system the resulting displacement of the LDA measurement volume and the Doppler frequency variation is systematically studied at different temperatures. Using a simple model of beam propagation under the influence of well-defined temperature inhomogeneities, the displacement of measurement volume and change in Doppler frequency are calculated and are found to be in agreement with the experimental observations. The results provide a rational framework for an assessment of the accuracy of LDA data in arbitrary transparent fluids with non-uniform refractive index.  相似文献   

8.
Refractive index matching methods for liquid flow investigations   总被引:2,自引:0,他引:2  
A difficulty common to most optical diagnostic techniques that are applied to fluid dynamics studies is the refraction of light passing through model and/or test section walls. The method of choice to eliminate refraction problems in liquid flows is to match refractive index. This paper presents techniques for refractive index matching including, (i) arrangement of test section and model, (ii) choice of solid and liquid materials, and (iii) methods for tuning the match. In addition, a new application of refractive index matching to liquid-liquid droplet studies is presented.The author would like to thank Rick James and Jon Martinez for their assistance in conducting the matching experiments and Professor Mickey Gunter for his comments on refractometry. We are grateful to the United States Department of Energy for financial support of the droplet work under Grant DE-FG07-86ER13572  相似文献   

9.
We present the experimental analysis of fluid flow at the pore-scale of a transparent porous medium with matched refractive indices of the solid and liquid phases. The planar laser-induced fluorescence (PLIF) technique described is the first to simultaneously visualize the 3D pore-scale flow of two immiscible liquid phases in porous media. Through the application of a highly precise index matching method and the employment of up-to-date CCD imaging hardware, the system features a high spatial resolution and sampling rate. The method was used to study the dispersion of a tracer dye in single-phase flow and the displacement of oil by water in an imbibition process.  相似文献   

10.
For accurate particle image velocimetry measurements in hemodynamics studies, it is important to use a fluid with a refractive index (n) matching that of the vascular models (phantoms) and ideally a dynamic viscosity matching human blood. In this work, a blood-mimicking fluid (BMF) composed of water, glycerol, and sodium iodide was formulated for a range of refractive indices to match most common silicone elastomers (n = 1.40–1.43) and with corresponding dynamic viscosity within the average cited range of healthy human blood (4.4 ± 0.5 cP). Both refractive index and viscosity were attained at room temperature (22.2 ± 0.2°C), which eliminates the need for a temperature-control system. An optimally matched BMF, suitable for use in a vascular phantom (n = 1.4140 ± 0.0008, Sylgard 184), was demonstrated with composition (by weight) of 47.38% water, 36.94% glycerol (44:56 glycerol–water ratio), and 15.68% sodium iodide salt, resulting in a dynamic viscosity of 4.31 ± 0.03 cP.  相似文献   

11.
An X-ray particle tracking velocimetry (PTV) technique was developed to simultaneously measure the sizes and velocities of microbubbles in a fluid without optical aberration. This technique is based on a combination of in-line X-ray holography and PTV. The X-ray PTV technique uses a configuration similar to that of conventional optical imaging techniques, and is easy to implement. In the present work, microbubbles generated from a fine wire by electrical heating were used as tracer particles. The X-ray PTV technique simultaneously recorded size and velocity data for microbubbles (b=10–60 m) moving upward in an opaque tube (inner diameter =2.7 mm). Due to the different refractive indices of water and air, phase contrast X-ray images clearly show the exact size and shape of overlapped microbubbles. In all of the working fluids tested (deionised water and 0.01 M and 0.10 M NaCl solutions), the measured terminal velocity of the microbubbles rising through the solution was proportional to the square of the bubble diameter. The proposed technique can be used to extract useful information on the behaviour of various bio/microscale fluid flows that are not amenable to analysis using conventional methods.  相似文献   

12.
Performing PIV measurements within complex turbomachinery with multiple blade rows is difficult due to the optical obstruction to the illuminating sheet and to the camera caused by the blades. This paper introduces a refractive index matched facility that overcomes this problem. The rotor and stator blades are made of transparent acrylic, and the working fluid has the same optical refractive index as the blades. A 64% by weight solution of sodium iodide in water is used for this purpose. This liquid has a kinematic viscosity of about 1.1᎒-6 m2/s, which is almost the same as that of water enabling operation at high Reynolds numbers. Issues related to operating with this fluid such as chemical stability, variations in transmittance and solutions to these problems are discussed. This setup allows full optical access to the entire rotor and stator passages both to the laser sheet and the camera. The experiments are conducted at different streamwise locations covering the entire flow fields around the rotor, the stator, the gap between them, and the wakes behind. Vector maps of the instantaneous and phase-averaged flow fields as well as the distribution of turbulent kinetic energy are obtained. Measurements at different magnifications enable us to obtain an overview of the flow structure, as well as detailed velocity distributions in the boundary layers and in the wakes.  相似文献   

13.
Cavitation structures in a large-scale (D = 8.25 mm), plain orifice style nozzle within a unique experimental rig are investigated using high-speed visualisation and digital image processing techniques. Refractive index matching with an acrylic nozzle is achieved using aqueous sodium iodide for the test fluid. Cavitation collapse length, unsteady shedding frequency and spray angles are measured for cavitation conditions from incipient to supercavitation for a range of Reynolds numbers, for a fixed L/D ratio of 4.85. Periodic cavitation shedding was shown to occur with frequencies between 500 and 2,000 Hz for conditions in which cavitation occupied less than 30% of the nozzle length. A discontinuity in collapse length was shown to occur once the cavitation exceeded this length, coinciding with a loss of periodic shedding. A mechanism for this behaviour is discussed. Peak spray angles of approximately θ ≈ 14° were recorded for supercavitation conditions indicating the positive influence of cavitation bubble collapse on the jet atomisation process.  相似文献   

14.
Optical measurement techniques such as particle image velocimetry (PIV) and laser Doppler velocimetry (LDV) are now routinely used in experimental fluid mechanics to investigate pure fluids or dilute suspensions. For highly concentrated particle suspensions, material turbidity has long been a substantial impediment to these techniques, which explains why they have been scarcely used so far. A renewed interest has emerged with the development of specific methods combining the use of iso-index suspensions and imaging techniques. This review paper gives a broad overview of recent advances in visualization techniques suited to concentrated particle suspensions. In particular, we show how classic methods such as PIV, LDV, particle tracking velocimetry, and laser induced fluorescence can be adapted to deal with concentrated particle suspensions.  相似文献   

15.
Particle image velocimetry (PIV) with refractive index matching was developed to map pore-scale fluid flow through a clear, acrylic two-dimensional network flow cell. A microscope objective lens was incorporated in the PIV set up so that flow in micro-scale throats could be measured. The flow cell consists of 20 × 20, equal-size cylindrical pore bodies, 2.5mm in diameter and 1.0mm in height, connected on a diamond lattice by 2.5 mm long, square cross-section throats of widths that varied randomly among 0.2, 0.6, and 1.0 mm. Micro-PIV data was used to obtain the two-dimensional streamline pattern of fluid flow and the velocity field over the field of view (FOV) by periodically illuminating seed particles following the flow and cross correlating particle positions to determine displacements over time. Refractive index matching of the flow cell and test fluid minimizes extraneous scattering of light at solid--liquid interfaces improving image resolution. Experimentally determined velocity vectors for single-phase flow through three pore bodies and their adjoining throats as well as for the outlet of the flow cell were compared with numerical simulations of flow through the cell.  相似文献   

16.
A simple model for the refractive index of sodium iodide aqueous solutions   总被引:3,自引:0,他引:3  
A model for predicting the refractive index of sodium iodide (NaI) aqueous solution n NaI as a function of temperature T, NaI concentration c and wavelength λ was determined for moderate parameter variations. The equation accurately predicted the salt concentration required to match n NaI to the refractive index of Pyrex n P. Received: 30 July 1998/Accepted: 14 December 1998  相似文献   

17.
In this work, an acrylic surface was optically contoured to correct for the optical distortion caused by a transparent pipe wall. This method can be applied to non-invasive viewing/imaging techniques for fluid flow experiments. Software tools were developed to aid in the design of an optically contoured acrylic test section for pipe-flow experiments. Numerical models were computed for a standard acrylic pipe, inner diameter 57.15 mm, with water enclosed. An optical contour prototype was machined on a 5-axis CNC machine, and polished with 1–15 μm diamond paste, alleviating any surface imperfections without significantly altering the contoured surface. Experiments were then performed to measure the emerging optical wavefront and was found to emerge planar when utilizing the optical contour. It was determined that the wavefront was corrected to within ten wavelengths of a Helium–Neon (He–Ne) laser beam.  相似文献   

18.
An extension of earlier work is made in the present paper to determine both theoretically and experimentally the coefficient of discharge and spray cone angle of a swirl nozzle using a time-independent purely viscous power-law non-Newtonian fluid. The theoretical predictions are made through an approximate analytical solution of the hydrodynamics of flow inside the nozzle. Experiments are carried out with aqueous solutions of CMC (carboxymethyl cellulose sodium salt) powder of various concentrations as the working fluids. The rheological properties of the working fluids are established by a capillary tube viscometer. From both the theoretical and experimental analyses, the pertinent independent input parameters are recognised as the generalised Reynolds number at inlet to the nozzle ReGi, the flow behaviour index of the fluid n, length-to-diameter ratio of the swirl chamber L1/D1, spin chamber angle 2α and the orifice-to-swirl-chamber-diameter ratio D1/D1. Although the theory predicts the correct qualitative trend in all cases, it does not agree well with the experimental results. Therefore, on the basis of the theoretical results, emperical relationships between nozzle characteristics and input parameters heve been established. Finally it is recognised that, regarding the injection conditions and fluid properties, the generalised Reynolds number at nozzle inlet ReGi and the flow behaviour index n have inverse and direct effects, respectively, on the coefficient of discharge, but have a negligible influence on the spray cone angle. Amongst the nozzle geometries, an increase in the values of D2/D1 and 2α or a decrease in the value of L1/D1 decrease the coefficient of discharge and increase the spray cone angle.  相似文献   

19.
Imaging methods are proposed for the characterisation of liquid flows through transparent porous media of matched refractive index. The methods are based on the analysis of laser-illuminated slices, and specialized for the case in which the porous medium is composed of irregularly packed spheres. They include algorithms for the reconstruction of the three-dimensional (3D) sphere arrangement based on a laser scan of the packed bed, particle tracking velocimetry applied to the motions of micro-tracers in a laser-illuminated plane, and techniques for the co-registration of geometry and velocity measurements acquired from different slices. The methods are applied to a cylindrical flow cell filled with mono-sized spheres and operated at Reynolds number Re = 28. The data produced include the full 3D geometry of the packed spheres assembly, the 2D fluid velocity field in the axial centre-plane of the flow cell, and the corresponding porosity and velocity distributions.  相似文献   

20.
In recent years, new laser and camera technology have enabled the development of high-speed imaging diagnostics for measurements at frame rates commensurate with the time scales of turbulent mixing, combustion, and emission formation in internal combustion engines. The ability to study the evolution of in-cylinder flow, fuel/air mixing, ignition, and combustion within individual cycles and for many consecutive cycles provides new insights into the physics and chemistry of internal combustion engine performance. Data for model development and device development are obtained with unprecedented access to the identification of random events such as cycle to cycle variation and ignition instabilities. This paper summarizes high-speed diagnostics developments with a focus on application to spark-ignition direct-injection gasoline engines. A range of optical techniques is described along with examples of applications in research and near-production engines. Measurements of in-cylinder velocities were conducted with particle image velocimetry. The spray evolution was followed with Mie scattering. Quantitative fuel distributions were recorded with laser-induced fluorescence. Fuel impingement on surfaces was quantified with refractive index matching. Combined velocity and fuel measurements were used to study ignition reliability. Chemiluminescence techniques provided insights into the evolution of the spark plasma as well as the growing flame kernel. Chemiluminescence and black body radiation imaging yielded insights into the formation and oxidation of soot.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏